NR 670.017(6)(6)A description of how hazardous waste residues and contaminated materials will be removed from the unit at closure, as required under s. NR 664.0228 (1) (a). For any wastes not to be removed from the unit upon closure, the owner or operator shall submit detailed plans and an engineering report describing how s. NR 664.0228 (1) (b) and (2) will be complied with. This information shall be included in the closure plan and, where applicable, the long-term care plan submitted under s. NR 670.014 (2) (m).
NR 670.017(7)(7)If ignitable or reactive wastes are to be placed in a surface impoundment, an explanation of how s. NR 664.0229 will be complied with.
NR 670.017(8)(8)If incompatible wastes, or incompatible wastes and materials will be placed in a surface impoundment, an explanation of how s. NR 664.0230 will be complied with.
NR 670.017(9)(9)A waste management plan for hazardous waste numbers F020, F021, F022, F023, F026 and F027 describing how the surface impoundment is or will be designed, constructed, operated and maintained to meet s. NR 664.0231. This submission shall address all of the following items specified in s. NR 664.0231:
NR 670.017(9)(a)(a) The volume, physical and chemical characteristics of the wastes, including their potential to migrate through soil or to volatilize or escape into the atmosphere.
NR 670.017(9)(b)(b) The attenuative properties of underlying and surrounding soils or other materials.
NR 670.017(9)(c)(c) The mobilizing properties of other materials co-disposed with these wastes.
NR 670.017(9)(d)(d) The effectiveness of additional treatment, design or monitoring techniques.
NR 670.017(10)(10)Information on air emission control equipment as required in s. NR 670.027.
NR 670.017 HistoryHistory: CR 05-032: cr. Register July 2006 No. 607, eff. 8-1-06.
NR 670.018NR 670.018Specific feasibility and plan of operation report information requirements for waste piles. Except as otherwise provided in s. NR 664.0001, owners and operators of facilities that store or treat hazardous waste in waste piles shall provide all of the following additional information:
NR 670.018(1)(1)A list of hazardous wastes placed or to be placed in each waste pile.
NR 670.018(2)(2)If an exemption is sought to s. NR 664.0251 and subch. F of ch. NR 664 as provided by s. NR 664.0250 (3) or 664.0090, an explanation of how the standards of s. NR 664.0250 (3) will be complied with or detailed plans and an engineering report describing how s. NR 664.0090 (2) (b) will be met.
NR 670.018(3)(3)Detailed plans and an engineering report describing how the waste pile is designed and is or will be constructed, operated and maintained to meet ss. NR 664.0019, 664.0251, 664.0252 and 664.0253, addressing all of the following items:
NR 670.018(3)(a)1.1. The liner system (except for an existing portion of a waste pile), if the waste pile shall meet s. NR 664.0251 (1). If an exemption from the requirement for a liner is sought as provided by s. NR 664.0251 (2), submit detailed plans, and engineering and hydrogeological reports, as appropriate, describing alternate designs and operating practices that will, in conjunction with location aspects, prevent the migration of any hazardous constituents into the groundwater or surface water at any future time.
NR 670.018(3)(a)2.2. The double liner and leak (leachate) detection, collection and removal system, if the waste pile shall meet s. NR 664.0251 (3). If an exemption from the requirements for double liners and a leak detection, collection and removal system or alternative design is sought as provided by s. NR 664.0251 (4), (5) or (6), submit appropriate information.
NR 670.018(3)(a)3.3. If the leak detection system is located in a saturated zone, submit detailed plans and an engineering report explaining the leak detection system design and operation, and the location of the saturated zone in relation to the leak detection system.
NR 670.018(3)(a)4.4. The construction quality assurance (CQA) plan if required under s. NR 664.0019.
NR 670.018(3)(a)5.5. Proposed action leakage rate, with rationale, if required under s. NR 664.0252, and response action plan, if required under s. NR 664.0253.
NR 670.018(3)(b)(b) Control of run-on.
NR 670.018(3)(c)(c) Control of run-off.
NR 670.018(3)(d)(d) Management of collection and holding units associated with run-on and run-off control systems.
NR 670.018(3)(e)(e) Control of wind dispersal of particulate matter, where applicable.
NR 670.018(4)(4)A description of how each waste pile, including the double liner system, leachate collection and removal system, leak detection system, cover system and appurtenances for control of run-on and run-off, will be inspected in order to meet s. NR 664.0254 (1), (2) and (3). This information shall be included in the inspection plan submitted under s. NR 670.014 (2) (e).
NR 670.018(5)(5)If treatment is carried out on or in the pile, details of the process and equipment used, and the nature and quality of the residuals.
NR 670.018(6)(6)If ignitable or reactive wastes are to be placed in a waste pile, an explanation of how s. NR 664.0256 will be complied with.
NR 670.018(7)(7)If incompatible wastes, or incompatible wastes and materials will be place in a waste pile, an explanation of how s. NR 664.0257 will be complied with.
NR 670.018(8)(8)A description of how hazardous waste residues and contaminated materials will be removed from the waste pile at closure, as required under s. NR 664.0258 (1). For any waste not to be removed from the waste pile upon closure, the owner or operator shall submit detailed plans and an engineering report describing how s. NR 664.0310 (1) and (2) will be complied with. This information shall be included in the closure plan and, where applicable, the long-term care plan submitted under s. NR 670.014 (2) (m).
NR 670.018(9)(9)A waste management plan for hazardous waste numbers F020, F021, F022, F023, F026 and F027 describing how a waste pile that is not enclosed (as defined in s. NR 664.0250 (3)) is or will be designed, constructed, operated and maintained to meet s. NR 664.0259. This submission shall address all of the following items specified in s. NR 664.0259:
NR 670.018(9)(a)(a) The volume, physical and chemical characteristics of the wastes to be disposed in the waste pile, including their potential to migrate through soil or to volatilize or escape into the atmosphere.
NR 670.018(9)(b)(b) The attenuative properties of underlying and surrounding soils or other materials.
NR 670.018(9)(c)(c) The mobilizing properties of other materials co-disposed with these wastes.
NR 670.018(9)(d)(d) The effectiveness of additional treatment, design or monitoring techniques.
NR 670.018 HistoryHistory: CR 05-032: cr. Register July 2006 No. 607, eff. 8-1-06.
NR 670.019NR 670.019Specific feasibility and plan of operation report information requirements for incinerators. Except as ss. NR 664.0340 and 670.019 (5) provide otherwise, owners and operators of facilities that incinerate hazardous waste shall fulfill sub. (1), (2) or (3).
NR 670.019(1)(1)When seeking an exemption under s. NR 664.0340 (2) or (3) (ignitable, corrosive or reactive wastes only), one of the following must be provided:
NR 670.019(1)(a)(a) Documentation that the waste is listed as a hazardous waste in subch. D of ch. NR 661, solely because it is ignitable (hazard code I) or corrosive (hazard code C) or both.
NR 670.019(1)(b)(b) Documentation that the waste is listed as a hazardous waste in subch. D of ch. NR 661, solely because it is reactive (hazard code R) for characteristics other than those listed in s. NR 661.0023 (1) (d) and (e), and will not be burned when other hazardous wastes are present in the combustion zone.
NR 670.019(1)(c)(c) Documentation that the waste is a hazardous waste solely because it possesses the characteristic of ignitability, corrosivity or both, as determined by the tests for characteristics of hazardous waste under subch. C of ch. NR 661.
NR 670.019(1)(d)(d) Documentation that the waste is a hazardous waste solely because it possesses the reactivity characteristics listed in s. NR 661.0023 (1) (a), (b), (c), (f), (g) or (h), and that it will not be burned when other hazardous wastes are present in the combustion zone.
NR 670.019(2)(2)Submit a trial burn plan or the results of a trial burn, including all required determinations, according to s. NR 670.062.
NR 670.019(3)(3)In lieu of a trial burn, the applicant may submit all of the following information:
NR 670.019(3)(a)(a) An analysis of each waste or mixture of wastes to be burned including all of the following:
NR 670.019(3)(a)1.1. Heat value of the waste in the form and composition in which it will be burned.
NR 670.019(3)(a)2.2. Viscosity (if applicable), or description of physical form of the waste.
NR 670.019(3)(a)3.3. An identification of any hazardous organic constituents listed in ch. NR 661 Appendix VIII, which are present in the waste to be burned, except that the applicant need not analyze for constituents listed in ch. NR 661 Appendix VIII, which would reasonably not be expected to be found in the waste. Identify the constituents excluded from analysis and state the basis for their exclusion. The waste analysis shall rely on appropriate analytical methods.
NR 670.019(3)(a)4.4. An approximate quantification of the hazardous constituents identified in the waste, within the precision produced by appropriate analytical methods.
NR 670.019(3)(a)5.5. A quantification of those hazardous constituents in the waste which may be designated as POHC’s based on data submitted from other trial or operational burns which demonstrate compliance with the performance standards in s. NR 664.0343.
NR 670.019(3)(b)(b) A detailed engineering description of the incinerator, including all of the following:
NR 670.019(3)(b)1.1. Manufacturer’s name and model number of incinerator.
NR 670.019(3)(b)2.2. Type of incinerator.
NR 670.019(3)(b)3.3. Linear dimension of incinerator unit including cross sectional area of combustion chamber.
NR 670.019(3)(b)4.4. Description of auxiliary fuel system (type/feed).
NR 670.019(3)(b)5.5. Capacity of prime mover.
NR 670.019(3)(b)6.6. Description of automatic waste feed cutoff systems.
NR 670.019(3)(b)7.7. Stack gas monitoring and pollution control monitoring system.
NR 670.019(3)(b)8.8. Nozzle and burner design.
NR 670.019(3)(b)9.9. Construction materials.
NR 670.019(3)(b)10.10. Location and description of temperature, pressure and flow indicating devices and control devices.
NR 670.019(3)(c)(c) A description and analysis of the waste to be burned compared with the waste for which data from operational or trial burns are provided to support the contention that a trial burn is not needed. The data shall include those items listed in par. (a). This analysis shall specify the POHCs which the applicant has identified in the waste for which a license is sought, and any differences from the POHCs in the waste for which burn data are provided.
NR 670.019(3)(d)(d) The design and operating conditions of the incinerator unit to be used, compared with that for which comparative burn data are available.
NR 670.019(3)(e)(e) A description of the results submitted from any previously conducted trial burns including all of the following:
NR 670.019(3)(e)1.1. Sampling and analysis techniques used to calculate performance standards in s. NR 664.0343.
NR 670.019(3)(e)2.2. Methods and results of monitoring temperatures, waste feed rates, carbon monoxide and an appropriate indicator of combustion gas velocity (including a statement concerning the precision and accuracy of this measurement).
NR 670.019(3)(f)(f) The expected incinerator operation information to demonstrate compliance with ss. NR 664.0343 and 664.0345 including all of the following:
NR 670.019(3)(f)1.1. Expected carbon monoxide (CO) level in the stack exhaust gas.
NR 670.019(3)(f)2.2. Waste feed rate.
NR 670.019(3)(f)3.3. Combustion zone temperature.
NR 670.019(3)(f)4.4. Indication of combustion gas velocity.
NR 670.019(3)(f)5.5. Expected stack gas volume, flow rate and temperature.
NR 670.019(3)(f)6.6. Computed residence time for waste in the combustion zone.
NR 670.019(3)(f)7.7. Expected hydrochloric acid removal efficiency.
NR 670.019(3)(f)8.8. Expected fugitive emissions and their control procedures.
NR 670.019(3)(f)9.9. Proposed waste feed cut-off limits based on the identified significant operating parameters.
NR 670.019(3)(g)(g) Supplemental information as the department finds necessary to achieve the purposes of this subsection.
NR 670.019(3)(h)(h) Waste analysis data, including that submitted in sub. (3) (a), sufficient to allow the department to specify in the license those principal organic hazardous constituents (license POHCs) for which destruction and removal efficiencies will be required.
NR 670.019(4)(4)The department shall approve a license application without a trial burn if the department finds that all of the following apply:
NR 670.019(4)(a)(a) The wastes are sufficiently similar.
NR 670.019(4)(b)(b) The incinerator units are sufficiently similar, and the data from other trial burns are adequate to specify (under s. NR 664.0345) operating conditions that will ensure that the performance standards in s. NR 664.0343 will be met by the incinerator.
NR 670.019(5)(5)When an owner or operator of a hazardous waste incineration unit becomes subject to hazardous waste licensing requirements after October 12, 2005, or when an owner or operator demonstrates compliance with the air emission standards and limitations in 40 CFR part 63, subpart EEE (for instance, by conducting a comprehensive performance test and submitting a notification of compliance under 40 CFR 63.1207 (j) and 63.1210 (d) documenting compliance with 40 CFR part 63, subpart EEE), the requirements of this section do not apply, except those provisions the department determines are necessary to ensure compliance with s. NR 664.0345 (1) and (3) if the owner or operator elects to comply with s. NR 670.235 (1) (a) 1. to minimize emissions of toxic compounds from startup, shutdown and malfunction events. Nevertheless, the department may apply the rules in this section, on a case-by-case basis, for purposes of information collection according to ss. NR 670.010 (11) and 670.032 (2) (b).
NR 670.019 HistoryHistory: CR 05-032: cr. Register July 2006 No. 607, eff. 8-1-06; CR 16-007: am. (3) (a) 3., 4., (5) Register July 2017 No. 739, eff. 8-1-17; correction in (5) made under s. 35.17, Stats., Register July 2017 No. 739; CR 19-082: am. (1) (b), (d) Register August 2020 No. 776, eff. 9-1-20
NR 670.021NR 670.021Specific feasibility and plan of operation report information requirements for landfills. Except as otherwise provided in s. NR 664.0001, owners and operators of facilities that dispose of hazardous waste in landfills shall provide all of the following additional information:
NR 670.021(1)(1)A list of the hazardous wastes placed or to be placed in each landfill or landfill cell.
NR 670.021(2)(2)Detailed plans and an engineering report describing how the landfill is designed and is or will be constructed, operated and maintained to meet ss. NR 664.0019, 664.0301, 664.0302 and 664.0303, addressing all of the following items:
NR 670.021(2)(a)1.1. The liner system (except for an existing portion of a landfill), if the landfill shall meet s. NR 664.0301 (1). If an exemption from the requirement for a liner is sought as provided by s. NR 664.0301 (2), submit detailed plans, and engineering and hydrogeological reports, as appropriate, describing alternate designs and operating practices that will, in conjunction with location aspects, prevent the migration of any hazardous constituents into the groundwater or surface water at any future time.
NR 670.021(2)(a)2.2. The double liner and leak (leachate) detection, collection and removal system, if the landfill shall meet s. NR 664.0301 (3). If an exemption from the requirements for double liners and a leak detection, collection and removal system or alternative design is sought as provided by s. NR 664.0301 (4), (5) or (6), submit appropriate information.
NR 670.021(2)(a)3.3. If the leak detection system is located in a saturated zone, submit detailed plans and an engineering report explaining the leak detection system design and operation, and the location of the saturated zone in relation to the leak detection system.