NR 440.642(6)(a)2.2. If accreditation is denied under this section, the administrator shall give written notice to the laboratory setting forth the basis for the determination. NR 440.642(6)(b)(b) In order for a test laboratory to qualify for accreditation the laboratory shall: NR 440.642(6)(b)1.1. Submit its written application providing the information related to laboratory equipment and management and technical experience of laboratory personnel. Applications from laboratories shall establish that: NR 440.642(6)(b)1.a.a. Laboratory personnel have a total of one year of relevant experience in particulate measurement, including at least 3 months experience in measuring particulate emissions from wood heaters, NR 440.642(6)(b)1.c.c. Laboratory personnel have experience in test management or laboratory management. NR 440.642(6)(b)2.2. Have no conflict of interest and receive no financial benefit from the outcome of certification testing conducted pursuant to sub. (4). NR 440.642(6)(b)3.3. Agree to enter into a contract as described in sub. (4) (g) with each wood heater manufacturer for whom a certification test has been performed. NR 440.642(6)(b)5.5. Demonstrate proficiency to achieve reproducible results with at least one test method and procedure in sub. (5) (b) by: NR 440.642(6)(b)5.a.a. Performing a test consisting of at least 8 test runs (2 in each of the 4 burn rate categories) on a wood heater identified by the administrator, NR 440.642(6)(b)5.b.b. Providing the administrator at least 30 days prior notice of the test to afford the administrator the opportunity to have an observer present, and NR 440.642(6)(b)5.c.c. Submitting to the administrator all documentation pertaining to the test including a complete test report and raw data sheets, laboratory technical notes, and test results for all test runs. NR 440.642(6)(b)7.7. Agree to participate annually in a proficiency testing program conducted by the administrator. NR 440.642(6)(b)8.8. Agree to allow the administrator access to observe certification testing. NR 440.642(6)(b)9.9. Agree to comply with reporting and recordkeeping requirements that affect testing laboratories. NR 440.642(6)(b)10.10. Agree to accept the reasonable cost of a random compliance audit test (as determined by the administrator) if it is selected to conduct the random compliance audit test of a model line originally tested for certification at another laboratory. NR 440.642(6)(e)1.1. The administrator may revoke the U.S. environmental protection agency laboratory accreditation if he or she determines that the laboratory: NR 440.642(6)(e)1.e.e. Failed to participate in a proficiency testing program, in accordance with its commitment under par. (b) 5., or NR 440.642(6)(e)2.2. Revocation of accreditation under this paragraph may not take effect until the laboratory concerned has been given written notice by the administrator setting forth the basis for the proposed determination and an opportunity for a hearing under sub. (10). However, if revocation is ultimately upheld, all tests conducted by the laboratory after written notice was given may, at the discretion of the administrator, be declared invalid. NR 440.642(6)(f)(f) Unless revoked sooner, a certificate of accreditation granted by the administrator shall be valid for 5 years from the date of issuance, for certificates issued under par. (b). NR 440.642(6)(g)(g) A laboratory accredited by the administrator shall seal any wood heater on which it performed certification tests, immediately upon completion or suspension of certification testing, by using a laboratory-specific seal. NR 440.642(7)(7) Permanent label, temporary label and owner’s manual. NR 440.642(7)(a)1.1. Each affected facility manufactured on or after July 1, 1988, or offered for sale at retail on or after July 1, 1990, shall have a permanent label affixed to it that meets the requirements of this subsection. NR 440.642(7)(a)3.d.d. Present required information in a manner so that it is likely to remain legible for the lifetime of the wood heater. NR 440.642(7)(a)3.e.e. Be affixed in such a manner that it cannot be removed from the appliance without damage to the label. NR 440.642(7)(a)4.4. The permanent label may be combined with any other label, as long as the required information is displayed, and the integrity of the permanent label is not compromised. NR 440.642(7)(b)(b) If the wood heater belongs to a model line certified under sub. (4) and has not been found to exceed the applicable emission limits or tolerances through quality assurance testing, one of the following statements, as appropriate, shall appear on the permanent label: State of Wisconsin
DEPARTMENT OF NATURAL RESOURCES
Certified to comply with July, 1988, particulate emission standards
Not approved for sale after June 30, 1992,
or
State of Wisconsin
DEPARTMENT OF NATURAL RESOURCES
Certified to comply with July, 1990, particulate emission standards.
NR 440.642(7)(d)(d) Any label statement under par. (b) constitutes a representation by the manufacturer as to any wood heater that bears it that: NR 440.642(7)(d)1.1. Certification was in effect at the time the wood heater left the possession of the manufacturer, NR 440.642(7)(d)2.2. The manufacturer was, at the time the label was affixed, conducting a quality assurance program in conformity with sub. (4) (o), NR 440.642(7)(d)3.3. As to any wood heater individually tested for emissions by the manufacturer under sub. (4) (o) 3., that it met the applicable emissions limits, and NR 440.642(7)(d)4.4. As to any wood heater individually inspected for tolerances under sub. (4) (o) 2., that the wood heater is within applicable tolerances. NR 440.642(7)(e)(e) If an affected facility is exempt from the emission limits in sub. (3), the following statement shall appear on the permanent label: State of Wisconsin
DEPARTMENT OF NATURAL RESOURCES
Not certified. Approved for sale until June 30, 1991.
NR 440.642(7)(f)1.1. If an affected facility is manufactured in the state of Wisconsin for export, the following statement shall appear on the permanent label: State of Wisconsin
DEPARTMENT OF NATURAL RESOURCES
Export stove. May not be operated within the United States.
NR 440.642(7)(f)2.2. If an affected facility is manufactured for use for research and development purposes as provided in sub. (1) (f), the following statement shall appear on the permanent label: State of Wisconsin
DEPARTMENT OF NATURAL RESOURCES
Not certified. Research Stove.
Not approved for sale.
NR 440.642(7)(f)3.3. If an appliance is a coal-only heater as defined in sub. (1), the following statement shall appear on the permanent label: State of Wisconsin
DEPARTMENT OF NATURAL RESOURCES
This heater is only for burning coal.
Use of any other solid fuel except for coal ignition purposes is a violation of law.
NR 440.642(7)(g)(g) Any affected facility that does not qualify for labeling under any of pars. (b) through (f), shall bear one of the following labels: NR 440.642(7)(g)1.1. If the test conducted under sub. (4) (n) indicates that the facility does not meet applicable emissions limits: State of Wisconsin
DEPARTMENT OF NATURAL RESOURCES.
Not certified. Does not meet DNR particulate emission standards.
IT IS AGAINST THE LAW TO OPERATE THIS WOOD HEATER.
NR 440.642(7)(g)2.2. If the test conducted under sub. (4) (n) indicates that the facility does meet applicable emissions limits: State of Wisconsin
DEPARTMENT OF NATURAL RESOURCES
Not certified. Meets DNR particulate emission standards.
State of Wisconsin
DEPARTMENT OF NATURAL RESOURCES.
Not certified. Not tested. Not approved for sale.
IT IS AGAINST THE LAW TO OPERATE THIS WOOD HEATER.