NR 440.62(7)(d)1.1. Detailed schematics, design specifications and piping and instrumentation diagrams.
NR 440.62(7)(d)2.2. The dates and descriptions of any changes in the design specifications.
NR 440.62(7)(d)3.3. A description of the parameter or parameters monitored as required in sub. (3) (j) 5., to ensure that control devices are operated and maintained in conformance with their design and an explanation of why that parameter (or parameters) was selected for the monitoring.
NR 440.62(7)(d)4.4. Periods when the closed vent systems and control devices required in sub. (3) (b), (c), (d) and (e) are not operated as designed, including periods when a flare pilot light does not have a flame.
NR 440.62(7)(d)5.5. Dates of startups and shutdowns of the closed vent systems and control devices required in sub. (3) (b), (c), (d) and (e).
NR 440.62(7)(e)(e) The following information pertaining to all equipment subject to the requirements in sub. (3) (a) to (j) shall be recorded in a log that is kept in a readily accessible location:
NR 440.62(7)(e)1.1. A list of identification numbers for equipment subject to the requirements of this section.
NR 440.62(7)(e)2.a.a. A list of identification numbers for equipment that are designated for no detectable emissions under the provisions of sub. (3) (b) 5., (c) 9. and (g) 6.
NR 440.62(7)(e)2.b.b. The designation of equipment as subject to the requirements of sub. (3) (b) 5., (c) 9., or (g) 6. shall be signed by the owner or operator.
NR 440.62(7)(e)3.3. A list of equipment identification numbers for pressure relief devices required to comply with sub. (3) (d).
NR 440.62(7)(e)4.a.a. The dates of each compliance test as required in sub. (3) (b) 5., (c) 9., (d) and (g) 6.
NR 440.62(7)(e)4.b.b. The background level measured during each compliance test.
NR 440.62(7)(e)4.c.c. The maximum instrument reading measured at the equipment during each compliance test.
NR 440.62(7)(e)5.5. A list of identification numbers for equipment in vacuum service.
NR 440.62(7)(f)(f) The following information pertaining to all valves subject to the requirements of sub. (3) (g) 7. and 8. and to all pumps subject to requirements of sub. (3) (b) 7. shall be recorded in a log that is kept in a readily accessible location:
NR 440.62(7)(f)1.1. A list of identification numbers for valves and pumps that are designated as unsafe-to-monitor, an explanation for each valve or pump stating why the valve or pump is unsafe-to-monitor and the plan for monitoring each valve or pump.
NR 440.62(7)(f)2.2. A list of identification numbers for valves that are designated as difficult-to-monitor, an explanation for each valve stating why the valve is difficult-to-monitor and the schedule for monitoring each valve.
NR 440.62(7)(g)(g) The following information shall be recorded for valves complying with sub. (4) (b).
NR 440.62(7)(g)1.1. A schedule of monitoring.
NR 440.62(7)(g)2.2. The percent of valves found leaking during each monitoring period.
NR 440.62(7)(h)(h) The following information shall be recorded in a log that is kept in a readily accessible location.
NR 440.62(7)(h)1.1. Design criterion required in sub. (3) (b) 4. e. and (c) 5. b. and explanation of the design criterion; and
NR 440.62(7)(h)2.2. Any changes to this criterion and the reasons for the changes.
NR 440.62(7)(i)(i) The following information shall be recorded in a log that is kept in a readily accessible location for use in determining exemptions as provided in sub. (1) (d):
NR 440.62(7)(i)1.1. An analysis demonstrating the design capacity of the affected facility,
NR 440.62(7)(i)2.2. A statement listing the feed or raw materials and products from the affected facilities and an analysis demonstrating whether these chemicals are heavy liquids or beverage alcohol, and
NR 440.62(7)(i)3.3. An analysis demonstrating that equipment is not VOC service.
NR 440.62(7)(j)(j) Information and data used to demonstrate that a piece of equipment is not in VOC service shall be recorded in a log that is kept in a readily accessible location.
NR 440.62(7)(k)(k) The provisions of s. NR 440.07 (2) and (4) do not apply to affected facilities subject to this section.
NR 440.62(8)(8)Reporting requirements.
NR 440.62(8)(a)(a) Each owner or operator subject to the provisions of this section shall submit semiannual reports to the department beginning 6 months after the initial start up date.
NR 440.62(8)(b)(b) The initial semiannual report to the department shall include the following information:
NR 440.62(8)(b)1.1. Process unit identification.
NR 440.62(8)(b)2.2. Number of valves subject to the requirements of sub. (3) (g), excluding those valves designated for no detectable emissions under the provisions of sub. (3) (g) 6.
NR 440.62(8)(b)3.3. Number of pumps subject to the requirements of sub. (3) (b), excluding those pumps designated for no detectable emissions under the provisions of sub. (3) (b) 5. and those pumps complying with sub. (3) (b) 6.
NR 440.62(8)(b)4.4. Number of compressors subject to the requirements of sub. (3) (c), excluding those compressors designated for no detectable emissions under the provisions of sub. (3) (c) 9. and those compressors complying with sub. (3) (c) 8.
NR 440.62(8)(c)(c) All semiannual reports to the department shall include the following information summarized from the information in sub. (7):
NR 440.62(8)(c)1.1. Process unit identification.
NR 440.62(8)(c)2.2. For each month during the semiannual reporting period.
NR 440.62(8)(c)2.a.a. Number of valves for which leaks were detected as described in sub. (3) (g) 2. or (4) (b),
NR 440.62(8)(c)2.b.b. Number of valves for which leaks were not repaired as required in sub. (3) (g) 4. a.,
NR 440.62(8)(c)2.c.c. Number of pumps for which leaks were detected as described in sub. (3) (b) 2. and 4. f. 1),
NR 440.62(8)(c)2.d.d. Number of pumps for which leaks were not repaired as required in sub. (3) (b) 3. a. and 4. f. 2),
NR 440.62(8)(c)2.e.e. Number of compressors for which leaks were detected as described in sub. (3) (c) 6.,
NR 440.62(8)(c)2.f.f. Number of compressors for which leaks were not repaired as required in sub. (3) (c) 7. a., and
NR 440.62(8)(c)2.g.g. The facts that explain each delay of repair and, where appropriate, why a process unit shutdown was technically infeasible.
NR 440.62(8)(c)3.3. Dates of process unit shutdowns which occurred within the semiannual reporting period.
NR 440.62(8)(c)4.4. Revisions to items reported according to par. (b) if changes have occurred since the initial report or subsequent revisions to the initial report.
NR 440.62(8)(d)(d) An owner or operator electing to comply with the provisions of sub. (4) (a) or (b) shall notify the department of the alternative standard selected 90 days before implementing either of the provisions.
NR 440.62(8)(e)(e) An owner or operator shall report the results of all performance tests in accordance with s. NR 440.08. The provisions of s. NR 440.08 (4) do not apply to affected facilities subject to the provisions of this section except that an owner or operator must notify the department of the schedule for the initial performance tests at least 30 days before the initial performance tests.
NR 440.62(9)(9)Reconstruction. For the purpose of this section:
NR 440.62(9)(a)(a) The cost of the following frequently replaced components of the facility may not be considered in calculating either the“fixed capital cost of the new components” or the “fixed capital costs that would be required to construct a comparable new facility” under s. NR 440.15: pump seals, nuts and bolts, rupture disks and packings.
NR 440.62(9)(b)(b) Under s. NR 440.15 the “fixed capital cost of new components” includes the fixed capital cost of all depreciable components (except components specified in par. (a) which are or will be replaced pursuant to all continuous programs of component replacement which are commenced within any 2-year period following the applicability date for the appropriate section. (See the “applicability and designation of affected facility” subsection of the appropriate section.) For purposes of this paragraph “commenced” means that an owner or operator has undertaken a continuous program of component replacement or that an owner or operator has entered into a contractual obligation to undertake a continuous program of component replacement or that an owner or operator has entered into a contractual obligation to undertake and complete, within a reasonable time, a continuous program of component replacement.
NR 440.62(10)(10)List of chemicals produced by affected facilities.
NR 440.62(10)(a)(a) The chemicals listed in Table A are produced, as intermediates or final products, by process units covered under this section. The applicability date for process units producing one or more of these chemicals is January 5, 1981.
a CAS numbers refer to the Chemical Abstracts Registry numbers assigned to specific chemicals, isomers, or mixtures of chemicals. Some isomers or mixtures that are covered by the standards do not have CAS numbers assigned to them. The standards apply to all of the chemicals listed, whether CAS numbers have been assigned or not.
b No CAS number(s) have been assigned to this chemical, its isomers, or mixtures containing these chemicals.
c CAS numbers for some of the isomers are listed; the standards apply to all of the isomers and mixtures, even if CAS numbers have not been assigned.
NR 440.62 HistoryHistory: Cr. Register, September, 1986, No. 369, eff. 10-1-86; am. (1) (c), (2) (intro.) and (a) 1. c., (3) (a) 3., (b) 4. a. and (c) 3., (4) (a) 2. intro., a. and 4., (6) (b) (intro.), (d) 1., (e) 1., (g) 5. and (9) (a), renum. (4) (b) 1. b. to g. to be 2.a. to f. and am. e. and f., r. and recr. (3) (j) 4., cr. (4) (b) 1. b., r. (5) and (8) (f), Register, September, 1990, No. 417, eff. 10-1-90; am. (2) (a) 1. c. and (10) (a) Table A, r. and recr. (6), Register, July, 1993, No. 451, eff. 7-1-93; am. (3) (a) 3., (10), Register, December, 1995, No. 480, eff. 1-1-96; 06-109: am. (1) (d) 2., (2) (a) 1. a. and c. and (b), (3) (a) 1. and (b) 4. a. and 6., (c) 2. (intro.), a. and b. and 8, (d) 3., (e) 1. and 2. (intro.), a. and b. and 3. and (f) 3., (g) (title) and (h) (title), (i) 1. and (j) 2. and 3., (6) (d) (intro.) and 1., (e) 1. and 2. and (g) 5. and 6., (7) (a) 1. and (f) (intro.) and 1., (8) (d) and (10) (a), cr. (1) (e), (2) (fm), (he), (hm), (hs) and (tm), (3) (b) 7. and 8., (d) 4. and (e) 2. d., (f) 4. and 5., (j) 7. to 12., renum. (2) (v), (x) and (z) to be (ke), (km) and (ks) and am. (km), r. and recr. (3) (h) 1. and (j) 6., (6) (g) 3. and 4., renum. (3) (j) 7. to be (3) (j) 13., Register May 2008 No. 629, eff. 6-1-08; correction in (1) (e) 2. made under s. 13.92 (4) (b) 7., Stats., Register May 2008 No. 629.
NR 440.63NR 440.63Beverage can surface coating industry.
NR 440.63(1)(1)Applicability and designation of affected facility.
NR 440.63(1)(a)(a) The provisions of this section apply to the following affected facilities in beverage can surface coating lines: each exterior base coat operation, each overvarnish coating operation and each inside spray coating operation.
NR 440.63(1)(b)(b) The provisions of this section apply to each affected facility which is identified in par. (a) and commences construction, modification, or reconstruction after November 26, 1980.
NR 440.63(2)(2)Definitions and symbols.
NR 440.63(2)(a)(a) As used in this section, terms not defined in this paragraph have the meanings given in s. NR 440.02.
NR 440.63(2)(a)1.1. “Beverage can” means any two-piece steel or aluminum container in which soft drinks or beer, including malt liquor, are packaged. The definition does not include containers in which fruit or vegetable juices are packaged.
NR 440.63(2)(a)2.2. “Exterior base coating operation” means the system on each beverage can surface coating line used to apply a coating to the exterior of a 2 piece beverage can body. The exterior base coat provides corrosion resistance and a background for lithography or printing operations. The exterior base coat operation consists of the coating application station, flashoff area and curing oven. The exterior base coat may be pigmented or clear (unpigmented).
NR 440.63(2)(a)3.3. “Inside spray coating operation” means the system on each beverage can surface coating line used to apply a coating to the interior of a two-piece beverage can body. This coating provides a protective film between the contents of the beverage can and the metal can body. The inside spray coating operation consists of the coating application station, flashoff area and curing oven. Multiple applications of an inside spray coating are considered to be a single coating operation.
NR 440.63(2)(a)4.4. “Overvarnish coating operation” means the system on each beverage can surface coating line used to apply a coating over ink which reduces friction for automated beverage can filling equipment, provides gloss and protects the finished beverage can body from abrasion and corrosion. The overvarnish coating is applied to two-piece beverage can bodies. The overvarnish coating operation consists of the coating application station, flashoff area and curing oven.
NR 440.63(2)(a)5.5. “Two-piece can” means any beverage can that consists of a body manufactured from a single piece of steel or aluminum and a top. Coatings for a two-piece can are usually applied after fabrication of the can body.
NR 440.63(2)(a)6.6. “VOC content” means all volatile organic compounds (VOCs) that are in a coating. VOC content is expressed in terms of kilograms of VOC per liter of coating solids.
NR 440.63(2)(b)(b) Symbols used in sub. (4) are defined as follows:
NR 440.63(2)(b)1.1. Ca is the VOC concentration in each gas stream leaving the control device and entering the atmosphere (parts per million as carbon).
NR 440.63(2)(b)2.2. Cb is the VOC concentration in each gas stream entering the control device (parts per million as carbon).
NR 440.63(2)(b)3.3. Dc is the density of each coating, as received (kilograms per liter).
NR 440.63(2)(b)4.4. Dd is the density of each VOC-solvent added to coatings (kilograms per liter).
NR 440.63(2)(b)5.5. Dr is the density of VOC-solvent recovered by an emission control device (kilograms per liter).
NR 440.63(2)(b)6.6. E is the VOC destruction efficiency of the control device (fraction).
NR 440.63(2)(b)7.7. F is the proportion of total VOC emitted by an affected facility which enters the control device to total emissions (fraction).
NR 440.63(2)(b)8.8. G is the volume-weighted average of VOC in coatings assumed in a calendar month per volume of coating solids applied (kilograms per liter of coating solids).
NR 440.63(2)(b)9.9. He is the fraction of VOC emitted at the coater and flashoff areas captured by a collection system.
NR 440.63(2)(b)10.10. Hh is the fraction of VOC emitted at the cure oven captured by a collection system.
NR 440.63(2)(b)11.11. Lc is the volume of each coating consumed, as received (liters).
NR 440.63(2)(b)12.12. Ld is the volume of each VOC-solvent added to coatings (liters).
NR 440.63(2)(b)13.13. Lr is the volume of VOC-solvent recovered by an emission control device (liters).
NR 440.63(2)(b)14.14. Ls is the volume of coating solids consumed (liters).