C7% is the concentration corrected to 7% oxygen
Cunc is the uncorrected pollutant concentration
O2 is the concentration of oxygen, percent
NR 440.76(15)(b) (b) Percent reduction in potential mercury emissions. You shall calculate the percent reduction in potential mercury emissions (%PHg) using the following equation:
where:
%PHg is the percent reduction of potential mercury emissions
Ei is the mercury emission concentration as measured at the air pollution control device inlet, corrected to 7% oxygen, dry basis
Eo is the mercury emission concentration as measured at the air pollution control device outlet, corrected to 7% oxygen, dry basis
NR 440.76(15)(c) (c) Percent reduction in potential hydrogen chloride emissions. You shall calculate the percent reduction in potential hydrogen chloride emissions (%PHCl) using the following equation:
where:
%PHCl is the percent reduction of the potential hydrogen chloride emissions
Ei is the hydrogen chloride emission concentration as measured at the air pollution control device inlet, corrected to 7% oxygen, dry basis
Eo is the hydrogen chloride emission concentration as measured at the air pollution control device outlet, corrected to 7% oxygen, dry basis
NR 440.76(15)(d) (d) Capacity of a municipal waste combustion unit. For a municipal waste combustion unit that can operate continuously for 24-hour periods, you shall calculate the municipal waste combustion unit capacity based on 24 hours of operation at the maximum charge rate. To determine the maximum charge rate, use one of the following 2 methods:
NR 440.76(15)(d)1. 1. For municipal waste combustion units with a design based on heat input capacity, you shall calculate the maximum charging rate based on the maximum heat input capacity and one of the following 2 heating values:
NR 440.76(15)(d)1.a. a. If your municipal waste combustion unit combusts refuse-derived fuel, use a heating value of 12,800 kilojoules per kilogram (5,500 Btu per pound).
NR 440.76(15)(d)1.b. b. If your municipal waste combustion unit combusts municipal solid waste, use a heating value of 10,500 kilojoules per kilogram (4,500 Btu per pound).
NR 440.76(15)(d)2. 2. For municipal waste combustion units with a design not based on heat input capacity, you shall use the maximum designed charging rate.
NR 440.76(15)(e) (e) Capacity of a batch municipal waste combustion unit. You shall calculate the capacity of a batch municipal waste combustion unit as the maximum design amount of municipal solid waste that can be charged per batch multiplied by the maximum number of batches that can be processed in 24 hours. Calculate the maximum number of batches by dividing 24 by the number of hours needed to process one batch. Retain fractional batches in the calculation. For example, if one batch requires 16 hours, the municipal waste combustion unit can combust 24/16, or 1.5 batches, in 24 hours.
NR 440.76(15)(f) (f) Quarterly carbon usage. If you use activated carbon to comply with the dioxins/furans or mercury limits, you shall calculate the required quarterly usage of carbon using the equation in subd. 1. for plant basis or the equation in subd. 2. for unit basis.
NR 440.76(15)(f)1. 1. `Plant basis.'
where:
C is the required quarterly carbon usage for the plant in kilograms or pounds
fi is the required carbon feed rate for the municipal waste combustion unit in kilograms or pounds per hour. The required carbon feed rate is the average carbon feed rate during the most recent mercury or dioxins/furans stack tests, whichever has a higher feed rate.
hi is the number of hours the municipal waste combustion unit was in operation during the calendar quarter.
n is the number of municipal waste combustion units, i, located at your plant.
NR 440.76(15)(f)2. 2. `Unit basis.'
where:
C is the required quarterly carbon usage for the unit in kilograms or pounds.
f is the required carbon feed rate for the municipal waste combustion unit in kilograms or pounds per hour. The required carbon feed rate is the average carbon feed rate during the most recent mercury or dioxins/furans stack tests, whichever has a higher feed rate.
h = number of hours the municipal waste combustion unit was in operation during the calendar quarter. - See PDF for table PDF
aAll emission limits, except for opacity, are measured at 7% oxygen.
bClass I units mean small municipal waste combustion units subject to this section that are located at municipal waste combustion plants with an aggregate plant combustion capacity of more than 250 tons per day of municipal solid waste. See sub. (2) for definitions.
cClass II units mean small municipal waste combustion units subject to this section that are located at municipal waste combustion plants with an aggregate plant combustion capacity of no more than 250 tons per day of municipal solid waste. See sub. (2) for definitions.
dNo monitoring, testing, recordkeeping or reporting is required to demonstrate compliance with the nitrogen oxides limit for Class II units. - See PDF for table PDF
aAll limits, except for opacity, are measured at 7% oxygen. Compliance is determined by continuous emission monitoring systems
bBlock averages, arithmetic mean. See sub. (2) for definitions.
c24-hour block average, geometric mean. See sub. (2) for definitions. - See PDF for table PDF
aClass I units mean small municipal waste combustion units subject to this section that are located at municipal waste combustion plants with an aggregate plant combustion capacity of more than 250 tons per day of municipal solid waste. See sub. (2) for definitions.
bIncorporated by reference in s. NR 440.17 (1). - See PDF for table PDF
aClass I units mean small municipal waste combustion units subject to this section that are located at municipal waste combustion plants with an aggregate plant combustion capacity of more than 250 tons per day of municipal solid waste. See sub. (2) for definitions.
bIncorporated by reference in s. NR 440.17 (1).
cIncorporated by reference in s. NR 440.17 (1). - See PDF for table PDF
aSimultaneously measure oxygen or carbon dioxide using Method 3A or 3B in Appendix A of 40 CFR part 60, incorporated by reference in s. NR 440.17 (1).
bUse CEMS to test sulfur dioxide, nitrogen oxides and carbon monoxide. Stack tests are not required except for quality assurance requirements in Appendix F of 40 CFR part 60, incorporated by reference in s. NR 440.17 (1).
cIncorporated by reference in s. NR 440.17 (1).
NR 440.76 History History: CR 06-109: cr. Register May 2008 No. 629, eff. 6-1-08.
NR 440.77 NR 440.77Commercial and Industrial Solid Waste Incineration Units for Which Construction is Commenced After November 30, 1999 or for Which Modification or Reconstruction is Commenced on or After June 1, 2001. This section establishes new source performance standards for commercial and industrial solid waste incineration (CISWI) units. Some of the requirements in this section apply to planning the CISWI unit, such as the preconstruction requirements in sub. (3), and shall be completed even before construction is initiated on the CISWI unit. Other requirements, such as the emission limitations and operating limits, apply after the CISWI unit begins operation.
NR 440.77 Note Note: For purposes of this section “I", “my", “you" or “your", refers to the owner or operator of a commercial and industrial solid waste incineration unit or the applicant for a permit to construct a commercial and industrial solid waste incineration unit, unless the context indicates otherwise. (See the definitions in sub. (2) (z) and (zm)).
NR 440.77(1) (1)Applicability.
NR 440.77(1)(a)(a) Does this section apply to my incineration unit? This section applies if your incineration unit meets all of the following requirements:
NR 440.77(1)(a)1. 1. Your incineration unit is a new incineration unit as specified in par. (b).
NR 440.77(1)(a)2. 2. Your incineration unit is a CISWI unit as defined in sub. (2).
NR 440.77(1)(a)3. 3. Your incineration unit is not exempt under par. (c).
NR 440.77(1)(b) (b) What is a new incineration unit?
NR 440.77(1)(b)1.1. A new incineration unit is an incineration unit that meets either of the following 2 criteria:
NR 440.77(1)(b)1.a. a. Construction on the unit commenced after November 30, 1999.
NR 440.77(1)(b)1.b. b. Reconstruction or modification of the unit commenced on or after June 1, 2001.
NR 440.77(1)(b)2. 2. This section does not affect your incineration unit if you make physical or operational changes to your incineration unit primarily to comply with the emission guidelines in subpart DDDD of 40 CFR part 60. Those changes do not qualify as reconstruction or modification under this section.
NR 440.77(1)(c) (c) What combustion units are exempt from this section? The following 15 types of units are exempt from this section:
NR 440.77(1)(c)1. 1. `Pathological waste incineration units.' Incineration units burning 90% or more by weight (on a calendar quarter basis and excluding the weight of auxiliary fuel and combustion air) of pathological waste, low-level radioactive waste or chemotherapeutic waste, as defined in sub. (2), if you meet the following 2 requirements:
NR 440.77(1)(c)1.a. a. Notify the department that the unit meets the criteria of this subdivision.
NR 440.77(1)(c)1.b. b. Keep records on a calendar quarter basis of the weight of pathological waste, low-level radioactive waste and chemotherapeutic waste burned, and the weight of all other fuels and wastes burned in the unit.
NR 440.77(1)(c)2. 2. `Agricultural waste incineration units.' Incineration units burning 90% or more by weight (on a calendar quarter basis and excluding the weight of auxiliary fuel and combustion air) of agricultural wastes as defined in sub. (2) if you meet the following 2 requirements:
NR 440.77(1)(c)2.a. a. Notify the department that the unit meets the criteria of this subdivision.
NR 440.77(1)(c)2.b. b. Keep records on a calendar quarter basis of the weight of agricultural waste burned, and the weight of all other fuels and wastes burned in the unit.
NR 440.77(1)(c)3. 3. `Municipal waste combustion units.' Incineration units that meet either of the following 2 criteria:
NR 440.77(1)(c)3.a. a. The units are regulated under s. NR 440.215, 440.216, 440.76, 40 CFR part 60 subpart Cb (Emission Guidelines and Compliance Time for Large Municipal Combustors that are Constructed on or Before September 20, 1994) or 40 CFR part 60 subpart BBBB (Emission Guidelines for Existing Stationary Sources: Small Municipal Waste Combustion Units).
NR 440.77(1)(c)3.b. b. The units burn greater than 30% municipal solid waste or refuse-derived fuel, as defined in ss. NR 440.215, 440.216, 440.76 and 40 CFR part 60 subpart BBBB, and the units have the capacity to burn less than 35 tons (32 megagrams) per day of municipal solid waste or refuse-derived fuel, if you meet the following 2 requirements:
1) Notify the department that the unit meets the criteria of this subdivision paragraph.
2) Keep records on a calendar quarter basis of the weight of municipal solid waste burned, and the weight of all other fuels and wastes burned in the unit.
NR 440.77(1)(c)4. 4. `Medical waste incineration units.' Incineration units regulated under s. NR 440.218 or 40 CFR part 60 subpart Ce (Emission Guidelines and Compliance Times for Hospital/Medical/Infectious Waste Incinerators).
NR 440.77(1)(c)5. 5. `Small power production facilities.' Units that meet all of the following 3 requirements:
NR 440.77(1)(c)5.a. a. The unit qualifies as a small power-production facility under section 3 (17) (C) of the Federal Power Act (16 USC 796 (17) (C)).
NR 440.77(1)(c)5.b. b. The unit burns homogeneous waste (not including refuse-derived fuel) to produce electricity.
NR 440.77(1)(c)5.c. c. You notify the department that the unit meets all of the criteria in this subdivision.
NR 440.77(1)(c)6. 6. `Cogeneration facilities.' Units that meet all of the following 3 requirements:
NR 440.77(1)(c)6.a. a. The unit qualifies as a cogeneration facility under section 3 (18) (B) of the Federal Power Act (16 USC 796 (18) (B)).
NR 440.77(1)(c)6.b. b. The unit burns homogeneous waste (not including refuse-derived fuel) to produce electricity and steam or other forms of energy used for industrial, commercial, heating or cooling purposes.
NR 440.77(1)(c)6.c. c. You notify the department that the unit meets all of the criteria in this subdivision.
NR 440.77(1)(c)7. 7. `Hazardous waste combustion units.' Units that meet either of the following 2 criteria:
NR 440.77(1)(c)7.a. a. Units for which you are required to get a permit under section 3005 of the Solid Waste Disposal Act (42 USC 6925) or a license under s. 291.25, Stats.
NR 440.77(1)(c)7.b. b. Units regulated under subpart EEE of 40 CFR part 63 (National Emission Standards for Hazardous Air Pollutants from Hazardous Waste Combustors).
NR 440.77(1)(c)8. 8. `Materials recovery units.' Units that combust waste for the primary purpose of recovering metals, such as primary and secondary smelters.
NR 440.77(1)(c)9. 9. `Air curtain incinerators.' Air curtain incinerators that burn only the following materials are only subject to sub. (13):
Loading...
Loading...
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date the chapter was last published.