Note: Variances from the separating distances may be granted as specified in s. NR 812.43 for earthen storage and manure stacks constructed and maintained to the specifications of Soil Conservation Standards No. 425 or 312, respectively.
3.
Soil absorption unit receiving 8,000 or more gallons per day, existing, abandoned, or alternate.
4.
Sludge landspreading or drying area.
5.
An earthen silage storage trench or pit.
6.
Liquid waste disposal system including, but not limited to a treatment pond or lagoon, ridge and furrow system and spray irrigation system.
Note: Variance from this separating distance may be granted for treatment ponds or lagoons constructed and maintained to an approval granted under ch. NR 213.
7.
Salvage yard.
8.
A salt or deicing material storage area including the building structure and the surrounding area where the material is transferred to vehicles. This subdivision does not include bagged deicing material.
9.
Solid waste processing facility.
10.
Solid waste transfer facility.
11.
The boundaries of a landspreading facility for spreading of petroleum-contaminated soil regulated under ch.
NR 718 while that facility is in operation.
(g) Twelve hundred feet between a well or reservoir and:
1.
The nearest edge of the limits of filling of an existing, proposed or abandoned landfill, measured to the nearest fill area of abandoned landfills, if known. Otherwise measured to the nearest property line where the landfill is located. The department may require, as part of a variance request, a land survey map, a scaled diagram of the landfill and the well location, or another accurate measurement method to determine and demonstrate the distance between the landfill and the well;
2.
The nearest edge of a coal storage area in excess of 500 tons; or
A-382.30 (11) (f) CONNECTION TO PRESSURIZED PUBLIC SEWER.
A-382.31 (4)-1. WHERE A VENT STACK AND STACK VENT ARE REQUIRED.
A-382.31 (4)-2. INSTALLATION OF VENT STACK AND STACK VENT.
A-382.31 (5) (a) VENTING OFFSETS OF 30 TO 45 DEGREES.
A-382.31 (5) (b) VENTS FOR OFFSETS OF MORE THAN 45 DEGREES.
A-382.31 (7) RELIEF VENTS FOR BUILDING DRAINS.
A-382.31 (9) FIXTURE VENTS.
A-382.31 (10)-1. CIRCUIT VENTING.
A-382.31 (10)-2. CIRCUIT VENTING.
A-382.31 (10)-3. CIRCUIT VENTING.
A-382.31 (10)-4. CIRCUIT VENTING.
A-382.31 (11) (a) COMMON VENTS, VERTICAL, SERVING ANY TWO FIXTURES.
A-382.31 (11) (b) COMMON VENTS, HORIZONTAL DRAINS.
A-382.31 (12) RETURN VENTS.
A-382.31 (13) (a) VERTICAL WET VENTS.
A-382.31 (13)-1. HORIZONTAL WET VENTS.
A-382.31 (14) (a) and (b) SIZING VENT STACKS AND STACK VENTS
A-382.31 (14) (c) SIZING BRANCH VENTS SERVING A WET VENT.
A-382.31 (14) (d) SIZING INDIVIDUAL VENTS.
A-382.31 (15) (a) VENT GRADES AND CONNECTIONS.
A-382.31 (15) (b) VENT GRADES AND CONNECTIONS.
A-382.31 (16) VENT TERMINALS.
VENTS TERMINATING THROUGH WALLS
A-382.31 (17) (a) COMBINATION DRAIN AND VENT STACKS.
A-382.31 (17) (c) COMBINATION DRAIN AND VENT LABORATORY SINK VENTING.
A-382.32 (4) (b) INSTALLATION OF TRAPS.
A-382.33 (6)-2. LOCAL WASTE PIPING.
A-382.33 (7) AIR-GAPS AND AIR-BREAKS.