2.   Liquid-tight, fabricated manure or silage storage structure, in ground or at ground surface;
3.   Wastewater treatment plant structure, conveyance or treatment unit; or
4.   Dry fertilizer or pesticide storage building or area when more than 100 pounds of either or both materials are stored;
5.   Well, drillhole or water system used for the underground placement of any waste, surface or subsurface water or any substance as defined in s. 160.01 (8), Stats.;
6.   Stormwater infiltration basin;
7.   Uncovered storage of silage on the ground surface;
8.   Water-tight silage storage trench or pit; or
9.   Lift station.
(e) Two hundred feet between a school well and a soil absorption unit receiving less than 8,000 gallons per day, existing or abandoned.
(ee) One hundred fifty feet between a well or reservoir and a temporary manure stack.
(f) Two hundred fifty feet between a well or reservoir and a:
1.   Manure stack.
2.   Earthen or excavated manure storage structure.
Note: Variances from the separating distances may be granted as specified in s. NR 812.43 for earthen storage and manure stacks constructed and maintained to the specifications of Soil Conservation Standards No. 425 or 312, respectively.
3.   Soil absorption unit receiving 8,000 or more gallons per day, existing, abandoned, or alternate.
4.   Sludge landspreading or drying area.
5.   An earthen silage storage trench or pit.
6.   Liquid waste disposal system including, but not limited to a treatment pond or lagoon, ridge and furrow system and spray irrigation system.
Note: Variance from this separating distance may be granted for treatment ponds or lagoons constructed and maintained to an approval granted under ch. NR 213.
7.   Salvage yard.
8.   A salt or deicing material storage area including the building structure and the surrounding area where the material is transferred to vehicles. This subdivision does not include bagged deicing material.
9.   Solid waste processing facility.
10.   Solid waste transfer facility.
11.   The boundaries of a landspreading facility for spreading of petroleum-contaminated soil regulated under ch. NR 718 while that facility is in operation.
(g) Twelve hundred feet between a well or reservoir and:
1.   The nearest edge of the limits of filling of an existing, proposed or abandoned landfill, measured to the nearest fill area of abandoned landfills, if known. Otherwise measured to the nearest property line where the landfill is located. The department may require, as part of a variance request, a land survey map, a scaled diagram of the landfill and the well location, or another accurate measurement method to determine and demonstrate the distance between the landfill and the well;
2.   The nearest edge of a coal storage area in excess of 500 tons; or
3.   A hazardous waste treatment facility regulated by the department. - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF
A-382.30 (11) (f) CONNECTION TO PRESSURIZED PUBLIC SEWER.
A-382.31 (4)-1. WHERE A VENT STACK AND STACK VENT ARE REQUIRED.
A-382.31 (4)-2. INSTALLATION OF VENT STACK AND STACK VENT.
A-382.31 (5) (a) VENTING OFFSETS OF 30 TO 45 DEGREES.
A-382.31 (5) (b) VENTS FOR OFFSETS OF MORE THAN 45 DEGREES.
A-382.31 (7) RELIEF VENTS FOR BUILDING DRAINS.
A-382.31 (9) FIXTURE VENTS.
A-382.31 (10)-1. CIRCUIT VENTING.
A-382.31 (10)-2. CIRCUIT VENTING.
A-382.31 (10)-3. CIRCUIT VENTING.
A-382.31 (10)-4. CIRCUIT VENTING.
A-382.31 (11) (a) COMMON VENTS, VERTICAL, SERVING ANY TWO FIXTURES.
A-382.31 (11) (b) COMMON VENTS, HORIZONTAL DRAINS.
A-382.31 (12) RETURN VENTS.
A-382.31 (13) (a) VERTICAL WET VENTS.
A-382.31 (13)-1. HORIZONTAL WET VENTS.
A-382.31 (13)-2. WET VENTING – FLOOR OUTLET FIXTURES.
A-382.31 (14) (a) and (b) SIZING VENT STACKS AND STACK VENTS
A-382.31 (14) (c) SIZING BRANCH VENTS SERVING A WET VENT.
A-382.31 (14) (d) SIZING INDIVIDUAL VENTS.
A-382.31 (15) (a) VENT GRADES AND CONNECTIONS.
A-382.31 (15) (b) VENT GRADES AND CONNECTIONS.
A-382.31 (16) VENT TERMINALS.
VENTS TERMINATING THROUGH WALLS
A-382.31 (17) (a) COMBINATION DRAIN AND VENT STACKS.
Loading...
Loading...