4) The corrective actions you have taken to meet the required quarterly usage of carbon.
5) The calendar date.
NR 440.76(13)(L)(L) Can reporting dates be changed?
NR 440.76(13)(L)1.1. If the department agrees, you may change the semiannual or annual reporting dates.
NR 440.76(13)(L)2.2. Section NR 440.185 (3) specifies the procedures to seek approval to change your reporting date.
NR 440.76(14)(14)Air curtain incinerators that burn 100% yard waste.
NR 440.76(14)(a)(a) What are the emission limits for air curtain incinerators that burn 100% yard waste? If your air curtain incinerator combusts 100% yard waste, only the emission limits in this subsection apply.
NR 440.76(14)(a)1.1. Within 60 days after your air curtain incinerator reaches the maximum load level at which it will operate, but no later than 180 days after its initial startup, you shall meet the following 2 limits:
NR 440.76(14)(a)1.a.a. The opacity limit is 10% (6-minute average) for air curtain incinerators that can combust at least 35 tons per day of municipal solid waste and no more than 250 tons per day of municipal solid waste.
NR 440.76(14)(a)1.b.b. The opacity limit is 35% (6-minute average) during the startup period that is within the first 30 minutes of operation.
NR 440.76(14)(a)2.2. Except during malfunctions, the requirements of this subsection apply at all times. Each malfunction may not exceed 3 hours.
NR 440.76(14)(b)(b) How must I monitor opacity for air curtain incinerators that burn 100% yard waste?
NR 440.76(14)(b)1.1. You shall use Method 9 in 40 CFR part 60, Appendix A, incorporated by reference in s. NR 440.17 (1), to determine compliance with the opacity limit.
NR 440.76(14)(b)2.2. You shall conduct an initial test for opacity as specified in s. NR 440.08.
NR 440.76(14)(b)3.3. After the initial test for opacity, you shall conduct annual tests no later than 13 calendar months following the date of your previous test.
NR 440.76(14)(c)(c) What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100% yard waste?
NR 440.76(14)(c)1.1. You shall provide a notice of construction that includes the following 4 items:
NR 440.76(14)(c)1.a.a. Your intent to construct the air curtain incinerator.
NR 440.76(14)(c)1.b.b. Your planned initial startup date.
NR 440.76(14)(c)1.c.c. Types of fuels you plan to combust in your air curtain incinerator.
NR 440.76(14)(c)1.d.d. The capacity of your incinerator, including supporting capacity calculations, as specified in sub. (15) (d) and (e).
NR 440.76(14)(c)2.2. You shall keep records of results of all opacity tests onsite in either paper copy or electronic format unless the department approves another format.
NR 440.76(14)(c)3.3. You shall keep all records for each incinerator for at least 5 years.
NR 440.76(14)(c)4.4. You shall make all records available for submittal to the department or for onsite review by an inspector.
NR 440.76(14)(c)5.5. You shall submit the results (each 6-minute average) of the opacity tests by February 1 of the year following the year of the opacity emission test.
NR 440.76(14)(c)6.6. You shall submit reports as a paper copy on or before the applicable submittal date. If the department agrees, you may submit reports on electronic media.
NR 440.76(14)(c)7.7. If the department agrees, you may change the annual reporting dates under s. NR 440.185 (3).
NR 440.76(14)(c)8.8. You shall keep a copy of all reports onsite for a period of 5 years.
NR 440.76(15)(15)Equations.
NR 440.76(15)(a)(a) Concentration correction to 7% oxygen. You shall correct any pollutant concentration to 7% oxygen using the following equation:
where:
C7% is the concentration corrected to 7% oxygen
Cunc is the uncorrected pollutant concentration
O2 is the concentration of oxygen, percent
NR 440.76(15)(b)(b) Percent reduction in potential mercury emissions. You shall calculate the percent reduction in potential mercury emissions (%PHg) using the following equation:
(
)
(
)
x
=
where:
%PHg is the percent reduction of potential mercury emissions
Ei is the mercury emission concentration as measured at the air pollution control device inlet, corrected to 7% oxygen, dry basis
Eo is the mercury emission concentration as measured at the air pollution control device outlet, corrected to 7% oxygen, dry basis
NR 440.76(15)(c)(c) Percent reduction in potential hydrogen chloride emissions. You shall calculate the percent reduction in potential hydrogen chloride emissions (%PHCl) using the following equation:
(
)
(
)
x
-
=
where:
%PHCl is the percent reduction of the potential hydrogen chloride emissions
Ei is the hydrogen chloride emission concentration as measured at the air pollution control device inlet, corrected to 7% oxygen, dry basis
Eo is the hydrogen chloride emission concentration as measured at the air pollution control device outlet, corrected to 7% oxygen, dry basis
NR 440.76(15)(d)(d) Capacity of a municipal waste combustion unit. For a municipal waste combustion unit that can operate continuously for 24-hour periods, you shall calculate the municipal waste combustion unit capacity based on 24 hours of operation at the maximum charge rate. To determine the maximum charge rate, use one of the following 2 methods:
NR 440.76(15)(d)1.1. For municipal waste combustion units with a design based on heat input capacity, you shall calculate the maximum charging rate based on the maximum heat input capacity and one of the following 2 heating values:
NR 440.76(15)(d)1.a.a. If your municipal waste combustion unit combusts refuse-derived fuel, use a heating value of 12,800 kilojoules per kilogram (5,500 Btu per pound).
NR 440.76(15)(d)1.b.b. If your municipal waste combustion unit combusts municipal solid waste, use a heating value of 10,500 kilojoules per kilogram (4,500 Btu per pound).
NR 440.76(15)(d)2.2. For municipal waste combustion units with a design not based on heat input capacity, you shall use the maximum designed charging rate.
NR 440.76(15)(e)(e) Capacity of a batch municipal waste combustion unit. You shall calculate the capacity of a batch municipal waste combustion unit as the maximum design amount of municipal solid waste that can be charged per batch multiplied by the maximum number of batches that can be processed in 24 hours. Calculate the maximum number of batches by dividing 24 by the number of hours needed to process one batch. Retain fractional batches in the calculation. For example, if one batch requires 16 hours, the municipal waste combustion unit can combust 24/16, or 1.5 batches, in 24 hours.
NR 440.76(15)(f)(f) Quarterly carbon usage. If you use activated carbon to comply with the dioxins/furans or mercury limits, you shall calculate the required quarterly usage of carbon using the equation in subd. 1. for plant basis or the equation in subd. 2. for unit basis.
NR 440.76(15)(f)1.1. ‘Plant basis.’
å
x
=
where:
C is the required quarterly carbon usage for the plant in kilograms or pounds
fi is the required carbon feed rate for the municipal waste combustion unit in kilograms or pounds per hour. The required carbon feed rate is the average carbon feed rate during the most recent mercury or dioxins/furans stack tests, whichever has a higher feed rate.
hi is the number of hours the municipal waste combustion unit was in operation during the calendar quarter.
n is the number of municipal waste combustion units, i, located at your plant.
NR 440.76(15)(f)2.2. ‘Unit basis.’
h
f
C
x
=
where:
C is the required quarterly carbon usage for the unit in kilograms or pounds.
f is the required carbon feed rate for the municipal waste combustion unit in kilograms or pounds per hour. The required carbon feed rate is the average carbon feed rate during the most recent mercury or dioxins/furans stack tests, whichever has a higher feed rate.
h = number of hours the municipal waste combustion unit was in operation during the calendar quarter.
a All emission limits, except for opacity, are measured at 7% oxygen.
b Class I units mean small municipal waste combustion units subject to this section that are located at municipal waste combustion plants with an aggregate plant combustion capacity of more than 250 tons per day of municipal solid waste. See sub. (2) for definitions.
c Class II units mean small municipal waste combustion units subject to this section that are located at municipal waste combustion plants with an aggregate plant combustion capacity of no more than 250 tons per day of municipal solid waste. See sub. (2) for definitions.
d No monitoring, testing, recordkeeping or reporting is required to demonstrate compliance with the nitrogen oxides limit for Class II units.
a All limits, except for opacity, are measured at 7% oxygen. Compliance is determined by continuous emission monitoring systems
b Block averages, arithmetic mean. See sub. (2) for definitions.
c 24-hour block average, geometric mean. See sub. (2) for definitions.
a Class I units mean small municipal waste combustion units subject to this section that are located at municipal waste combustion plants with an aggregate plant combustion capacity of more than 250 tons per day of municipal solid waste. See sub. (2) for definitions.
b Incorporated by reference in s. NR 440.17 (1).
a Class I units mean small municipal waste combustion units subject to this section that are located at municipal waste combustion plants with an aggregate plant combustion capacity of more than 250 tons per day of municipal solid waste. See sub. (2) for definitions.
b Incorporated by reference in s. NR 440.17 (1).
c Incorporated by reference in s. NR 440.17 (1).
a Simultaneously measure oxygen or carbon dioxide using Method 3A or 3B in Appendix A of 40 CFR part 60, incorporated by reference in s. NR 440.17 (1).
b Use CEMS to test sulfur dioxide, nitrogen oxides and carbon monoxide. Stack tests are not required except for quality assurance requirements in Appendix F of 40 CFR part 60, incorporated by reference in s. NR 440.17 (1).
c Incorporated by reference in s. NR 440.17 (1).
NR 440.76 HistoryHistory: CR 06-109: cr. Register May 2008 No. 629, eff. 6-1-08.
NR 440.77NR 440.77Commercial and Industrial Solid Waste Incineration Units for Which Construction is Commenced After November 30, 1999 or for Which Modification or Reconstruction is Commenced on or After June 1, 2001. This section establishes new source performance standards for commercial and industrial solid waste incineration (CISWI) units. Some of the requirements in this section apply to planning the CISWI unit, such as the preconstruction requirements in sub. (3), and shall be completed even before construction is initiated on the CISWI unit. Other requirements, such as the emission limitations and operating limits, apply after the CISWI unit begins operation.
Loading...
Loading...