ATCP 76.17(3)
(3)
Testing reagent technologies. The disinfectant or sanitizer testing reagent shall use one of the following technologies:
ATCP 76.17(3)(a)
(a)
Method. Diethyl–p–phenylene diamine or DPD in powder or liquid form. A test kit using the titrimetric method, ferrous ammonium sulfate and diethyl–p–phenylene diamine or FAS-DPD for chlorine and bromine testing and colorimetric comparators used for additional water testing shall be approved by the department and shall provide for accurate comparison in the required range for each test pursuant to
s.
ATCP 76.14 Table A.
Pf
ATCP 76.17(3)(b)
(b)
Alternatives. Other photometric, electronic, or other technology that achieves the accuracy as described in s.
ATCP 76.17 Table A, and measures analytes within the range pursuant to
s. ATCP 76.14 Table A.
Pf
ATCP 76.17 History
History: CR 22-021: cr.
Register June 2023 No. 810, eff. 9-24-23.
ATCP 76.18(1)(1)
All pools, except whirlpools, therapy, and excercise pools. ATCP 76.18(1)(a)(a)
pH and disinfectant or sanitizer. Except as provided under
sub.
(3),
water
shall
be
tested
for
pH
and
disinfectant or sanitizer residual at the following times:
ATCP 76.18(1)(a)1.
1. Daily before the pool is open to the public or before the pool is in use.
Pf
ATCP 76.18(1)(b)
(b)
Combined chlorine. If chlorine is used, the water shall also be tested at least twice a week for the combined chlorine level.
Pf
ATCP 76.18(1)(c)
(c)
Alkalinity. Water
shall
also
be
tested
at
least
once
a
week
for
total
alkalinity.
Pf
ATCP 76.18(1)(d)
(d)
Cyanuric acid. If cyanuric acid is used in the water basin, the cyanuric acid concentration in the water shall be tested at least once a week.
Pf
ATCP 76.18(2)(a)
(a)
pH and disinfectant or sanitizer. Except as provided under sub.
(3), water shall be tested for pH and disinfectant or sanitizer residual at the following times:
ATCP 76.18(2)(a)1.
1. Before the pool is open to the public or before the pool is in use and at least 4 times daily.
Pf
ATCP 76.18(2)(b)
(b)
Combined chlorine. When chlorine is used, the water shall be tested at least once daily for the combined chlorine level.
Pf
ATCP 76.18(2)(c)
(c)
Alkalinity. Water
shall
be
tested
at
least
once
a
week
for
total
alkalinity.
Pf
ATCP 76.18(2)(d)
(d)
Cyanuric acid. When cyanuric acid is used in the water basin, the cyanuric acid concentration in the water shall be tested at least once a week.
Pf
ATCP 76.18(3)
(3)
Electronic monitoring device. For a properly maintained electronic monitoring device installed to control pH and disinfectant or sanitizer, the operator shall:
ATCP 76.18(3)(a)
(a)
Frequency. Manually
tested
the pool at
least
once
a
day
for
pH
and
disinfectant or sanitizer residual with an approved test kit pursuant to
s. ATCP 76.17 Table A.
Pf
ATCP 76.18(3)(b)
(b)
Maintenance. Periodically
monitor
the
device
to
determine if
it
meets
operating
criteria
pursuant to
s.
ATCP 76.14
(5).
Pf
ATCP 76.18(4)
(4)
Increased testing. The department or its agent may require more frequent testing if the testing logs are not maintained and the operator demonstrates a lack of active managerial control.
Pf
ATCP 76.18 History
History: CR 22-021: cr.
Register June 2023 No. 810, eff. 9-24-23.
ATCP 76.19
ATCP 76.19
Water supply and temperature. ATCP 76.19(1)(1)
Water supply protection. A minimum air gap of 2 pipe diameters or 6 inches, whichever is less, shall exist between the potable water supply inlet and the overflow point of any pool, makeup tank, surge tank, solution tank, or slurry tank unless another approved backflow and backsiphonage prevention device is
provided.
P
ATCP 76.19(2)
(2)
Water source. The water supplied to a pool shall be from a source approved by the Wisconsin department of natural resources pursuant to ch.
NR 108,
811, or
812.
P
ATCP 76.19(3)
(3)
Water level. Proper water level shall be maintained at all times when
the
pool
is
open.
Pf
ATCP 76.19(3)(a)
(a)
Skimmers. Water levels
in
pools
with
skimmers shall be maintained at a level such that the weir is half submerged or in the case of a floating weir, used according to manufacturer's directions.
Pf
ATCP 76.19(3)(b)
(b)
Gutters. Pools
designed
with
gutters
shall
have
a
continuous
water
supply over the gutter to provide effective
skimming.
Pf
ATCP 76.19(4)(a)1.1. An accurate thermometer shall be located in
the
pool
water
return
line.
Pf
ATCP 76.19(4)(a)2.
2. The thermometer shall be accessible for observation by the operator.
Pf
ATCP 76.19(4)(b)1.1. Except
as
provided
in
par.
(d),
the
water
temperature
of
an indoor pool shall be between 70
°F or 21
°C and 90
°F or 32
°C.
P
ATCP 76.19(4)(b)2.
2. The minimum water temperature for an outdoor pool shall be 65
°F
or 18
°C.
P
ATCP 76.19(4)(c)
(c)
Whirlpool water temperature. The water temperature in a whirlpool shall be greater than 90
°F or 32
°C, and may not exceed 104
°F or 40
°C.
P
ATCP 76.19(4)(d)1.1. Cold soak pools may be operated at a lower temperature than specified under
par. (b).
ATCP 76.19 History
History: CR 22-021: cr.
Register June 2023 No. 810, eff. 9-24-23.
ATCP 76.20(1)(a)(a)
General requirement. Each pool shall be under the supervision of at least one operator, except that if multiple pools are located on the same premise, and licensed by the same person, they may be supervised by one operator.
Pf
ATCP 76.20(1)(b)
(b)
Operator responsibilities. Each operator shall be responsible
for
pool
operation
and
maintenance
including
equipment
shut-down, backwashing, daily maintenance and vacuuming, and maintenance of water quality pursuant to ch.
ATCP 76.
Pf
ATCP 76.20(2)(a)1.1. Each water attraction or multiple water attractions on the same premise shall
have
at
least
one
certified operator.
Pf
ATCP 76.20(2)(a)2.
2. An owner of a pool who demonstrates a lack of active managerial control over the pool operation by having 2 or more reinspections in a 3-year period is required to have a certified operator.
Pf
ATCP 76.20(2)(a)3.
3. Pool operator certification for a water attraction shall be obtained within 90 days of receiving a new license or a pool meeting the conditions under subd.
2. Pf
ATCP 76.20(2)(a)3.a.
a. A pool that is required to have a certified operator under subd. 2, may contract with a certified operator.
ATCP 76.20(2)(a)4.
4. The owner of a pool shall replace a certified operator within 90 days after a certified operator's departure.
Pf
ATCP 76.20(2)(b)
(b)
Certified operator duties. A certified operator is responsible for all of the following:
ATCP 76.20(2)(c)
(c)
Documentation of certification. A current copy of the certified operator's certification
shall
be
maintained
at
the pool.
Pf
ATCP 76.20 History
History: CR 22-021: cr.
Register June 2023 No. 810, eff. 9-24-23.
ATCP 76.21(1)(a)(a)
Supervision. Each pool shall
be
under
the
supervision
of
at
least
one
responsible
supervisor at
all
times
when
the
pool
is
in
use
or
is
open
to
the
public.
P
ATCP 76.21(1)(b)
(b)
Availability. The responsible supervisor
shall
be
on
the
premises
or
immediately available
via
a phone number posted by the emergency phone and shall respond to an unsafe or
unsanitary
condition
within 15 minutes, at
any
time
the
pool
is
open
for
use.
P
ATCP 76.21(1)(c)
(c)
Duties. The
responsible
supervisor
shall ensure all of the following:
ATCP 76.21(1)(c)6.
6. Monthly secondary anti-entrapment device testing is performed, if applicable.
P
ATCP 76.21(1)(c)9.
9. The
rope separating the shallow and deep portions of the pool
is
in
place during required
times.
P
ATCP 76.21(1)(c)11.
11. A pool cover or blanket, if provided, does not pose a safety hazard to patrons.
P
ATCP 76.21 History
History: CR 22-021: cr.
Register June 2023 No. 810, eff. 9-24-23.
ATCP 76.22(1)(1)
Lifeguard and attendant staffing plans. A pool that is not required to have an attendant or lifeguard is not required to have a lifeguard or attendant staffing plan.
ATCP 76.22(1)(a)
(a)
Staffing plan requirements. The owner or operator of
a
pool,
including
a
whirlpool
over
4
feet
deep
and
a
pool
with a visual obstruction, shall
have
a
written
lifeguard and attendant staffing plan.
Pf
ATCP 76.22(1)(b)
(b)
Plan criteria. The written lifeguard and attendant staffing plan shall include all of the following:
ATCP 76.22(1)(b)4.
4. The location of each lifeguard station, lifeguard roaming or walking patrol ensuring that glare conditions are assessed from each location to determine if the bottom and objects in the pool are clearly visible.
Pf
ATCP 76.22(1)(b)7.
7. Diagrams shall be provided with the following information for each use of the pool, for both average and maximum capacity: