HOE is the estimated heat output in Btu/hr
HV is the heating value of fuel, 19,140 Btu/kg (8,700 Btu/lb)
BR is the burn rate of dry test fuel, kg/hr (lb/hr)
NR 440.642(7)(i)5.5. Statements regarding the importance of operation and maintenance. Instructions regarding which statements shall be used are provided in 40 CFR part 60, Appendix I, Section 2., incorporated by reference in s. NR 440.17; and NR 440.642(7)(j)1.1. An affected facility permanently labeled under par. (e), (f) 3. or (g) shall have attached to it a temporary label that shall contain only the information provided for in 40 CFR part 60, Appendix I, section 2.3, 2.4 or 2.5, as applicable, incorporated by reference in s. NR 440.17. NR 440.642(7)(j)2.a.a. Be affixed to a location on the wood heater that is readily seen and accessible when the wood heater is offered for sale to consumers by any commercial owner; NR 440.642(7)(j)2.c.c. Be attached to the wood heater in such a way that it can be easily removed by the consumer upon purchase, except that the label on wood heaters displayed by a commercial owner may have an adhesive backing or other means to preserve the label to prevent its removal or destruction; NR 440.642(7)(j)2.d.d. Be printed on 90 pound bond paper in black ink with a white background except that those for models that are not otherwise exempted which do not meet the applicable emission limits, or have not been tested pursuant to this section, shall be on a red background as described in 40 CFR part 60, Appendix I, Section 2.5, incorporated by reference in s. NR 440.17; NR 440.642(7)(k)1.1. Each affected facility offered for sale by a commercial owner shall be accompanied by an owner’s manual that shall contain the information listed in subds. 2. (pertaining to installation) and 3. (pertaining to operation and maintenance). The information shall be adequate to enable consumers to achieve optimal emissions performance. The information shall also be consistent with the operating instructions provided by the manufacturer to the laboratory for operating the wood heater during certification testing, except for details of the certification test that would not be relevant to the ultimate purchaser. NR 440.642(7)(k)2.2. Installation information in the owner’s manual shall state the requirements for achieving proper draft. NR 440.642(7)(k)3.3. Operation and maintenance information in the owner’s manual shall include: NR 440.642(7)(k)3.a.a. Wood loading procedures, recommendations on wood selection, and warnings on what fuels not to use, such as treated wood, colored paper, cardboard, solvents, trash and garbage, NR 440.642(7)(k)3.f.f. For catalytic models, information on the following pertaining to the catalytic combustor: 1) Procedures for achieving and maintaining catalyst activity,
2) Maintenance procedures,
3) Procedures for determining deterioration or failure,
4) Procedures for replacement, and
5) Information on how to exercise warranty rights, and