This is the preview version of the Wisconsin State Legislature site.
Please see http://docs.legis.wisconsin.gov for the production version.
Not approved for sale after June 30, 1992,
or
State of Wisconsin
DEPARTMENT OF NATURAL RESOURCES
Certified to comply with July, 1990, particulate emission standards.
NR 440.642(7)(d) (d) Any label statement under par. (b) constitutes a representation by the manufacturer as to any wood heater that bears it that:
NR 440.642(7)(d)1. 1. Certification was in effect at the time the wood heater left the possession of the manufacturer,
NR 440.642(7)(d)2. 2. The manufacturer was, at the time the label was affixed, conducting a quality assurance program in conformity with sub. (4) (o),
NR 440.642(7)(d)3. 3. As to any wood heater individually tested for emissions by the manufacturer under sub. (4) (o) 3., that it met the applicable emissions limits, and
NR 440.642(7)(d)4. 4. As to any wood heater individually inspected for tolerances under sub. (4) (o) 2., that the wood heater is within applicable tolerances.
NR 440.642(7)(e) (e) If an affected facility is exempt from the emission limits in sub. (3), the following statement shall appear on the permanent label:
State of Wisconsin
DEPARTMENT OF NATURAL RESOURCES
Not certified. Approved for sale until June 30, 1991.
NR 440.642(7)(f)1.1. If an affected facility is manufactured in the state of Wisconsin for export, the following statement shall appear on the permanent label:
State of Wisconsin
DEPARTMENT OF NATURAL RESOURCES
Export stove. May not be operated within the United States.
NR 440.642(7)(f)2. 2. If an affected facility is manufactured for use for research and development purposes as provided in sub. (1) (f), the following statement shall appear on the permanent label:
State of Wisconsin
DEPARTMENT OF NATURAL RESOURCES
Not certified. Research Stove.
Not approved for sale.
NR 440.642(7)(f)3. 3. If an appliance is a coal-only heater as defined in sub. (1), the following statement shall appear on the permanent label:
State of Wisconsin
DEPARTMENT OF NATURAL RESOURCES
This heater is only for burning coal.
Use of any other solid fuel except for coal ignition purposes is a violation of law.
NR 440.642(7)(g) (g) Any affected facility that does not qualify for labeling under any of pars. (b) through (f), shall bear one of the following labels:
NR 440.642(7)(g)1. 1. If the test conducted under sub. (4) (n) indicates that the facility does not meet applicable emissions limits:
State of Wisconsin
DEPARTMENT OF NATURAL RESOURCES.
Not certified. Does not meet DNR particulate emission standards.
IT IS AGAINST THE LAW TO OPERATE THIS WOOD HEATER.
NR 440.642(7)(g)2. 2. If the test conducted under sub. (4) (n) indicates that the facility does meet applicable emissions limits:
State of Wisconsin
DEPARTMENT OF NATURAL RESOURCES
Not certified. Meets DNR particulate emission standards.
NR 440.642(7)(g)3. 3. If the facility has not been tested as required by sub. (4) (e).
State of Wisconsin
DEPARTMENT OF NATURAL RESOURCES.
Not certified. Not tested. Not approved for sale.
IT IS AGAINST THE LAW TO OPERATE THIS WOOD HEATER.
NR 440.642(7)(h) (h) For affected facilities equipped with catalytic combustors, the following statement shall appear on the permanent label:
This wood heater contains a catalytic combustor, which needs periodic inspection and replacement for proper operation. Consult owner's manual for further information. It is against the law to operate this wood heater in a manner inconsistent with operating instructions in the owner's manual or if the catalytic element is deactivated or removed.
NR 440.642(7)(i) (i) An affected facility permanently labeled under par. (b) shall have attached to it a temporary label that shall contain only the following:
NR 440.642(7)(i)1. 1. A statement indicating the compliance status of the model. The statement shall be one of the statements provided in 40 CFR part 60, Appendix I, Section 2.2.1, incorporated by reference in s. NR 440.17. Instructions on the statement to select are provided in 40 CFR part 60 in Appendix I, incorporated by reference in s. NR 440.17.
NR 440.642(7)(i)2. 2. A graphic presentation of the composite particulate matter emission rate as determined in the certification test. The method for presenting this information is provided in 40 CFR part 60, Appendix I, Section 2.2.2, incorporated by reference in s. NR 440.17.
NR 440.642(7)(i)3. 3. A graphic presentation of the overall thermal efficiency of the model. The method for presenting this information is provided in 40 CFR part 60, Appendix I, Section 2.2.3, incorporated by reference in s. NR 440.17. At the discretion of the manufacturer, either the actual measured efficiency of the model or its estimated efficiency may be used for purposes of this paragraph. The actual efficiency is the efficiency measured in tests conducted pursuant to 40 CFR 670.534 (d). The estimated efficiency shall be 72% if the model is catalyst-equipped and 63% if the model is not catalyst equipped, and 78% if the model is designed to burn wood pellets for fuel.
NR 440.642(7)(i)4. 4. A numerical expression of the heat output range of the unit, in British thermal units per hour (Btu/hr) rounded to the nearest 100 Btu/hr.
NR 440.642(7)(i)4.a. a. If the manufacturer elects to report the overall efficiency of the model based on test results pursuant to subd. 3., the manufacturer shall report the heat output range measured during the efficiency test. If an accessory device is used in the certification test to achieve any low burn rate criterion specified in this section, and if this accessory device is not sold as a part of the wood heater, the heat output range shall be determined using the formula in subd. 4. b. based upon the lowest sustainable burn rate achieved without the accessory device.
NR 440.642(7)(i)4.b. b. If the manufacturer elects to use the estimated efficiency as provided in subd. 3., the manufacturer shall estimate the heat output of the model as follows:
where:
HOE is the estimated heat output in Btu/hr
HV is the heating value of fuel, 19,140 Btu/kg (8,700 Btu/lb)
BR is the burn rate of dry test fuel, kg/hr (lb/hr)
NR 440.642(7)(i)5. 5. Statements regarding the importance of operation and maintenance. Instructions regarding which statements shall be used are provided in 40 CFR part 60, Appendix I, Section 2., incorporated by reference in s. NR 440.17; and
NR 440.642(7)(i)6. 6. The manufacturer and the identification of the model.
NR 440.642(7)(j)1.1. An affected facility permanently labeled under par. (e), (f) 3. or (g) shall have attached to it a temporary label that shall contain only the information provided for in 40 CFR part 60, Appendix I, section 2.3, 2.4 or 2.5, as applicable, incorporated by reference in s. NR 440.17.
NR 440.642(7)(j)2. 2. The temporary label of an affected facility permanently labeled under par. (b), (e), (f) 3. or (g) shall:
NR 440.642(7)(j)2.a. a. Be affixed to a location on the wood heater that is readily seen and accessible when the wood heater is offered for sale to consumers by any commercial owner;
NR 440.642(7)(j)2.b. b. Not be combined with any other label or information;
NR 440.642(7)(j)2.c. c. Be attached to the wood heater in such a way that it can be easily removed by the consumer upon purchase, except that the label on wood heaters displayed by a commercial owner may have an adhesive backing or other means to preserve the label to prevent its removal or destruction;
NR 440.642(7)(j)2.d. d. Be printed on 90 pound bond paper in black ink with a white background except that those for models that are not otherwise exempted which do not meet the applicable emission limits, or have not been tested pursuant to this section, shall be on a red background as described in 40 CFR part 60, Appendix I, Section 2.5, incorporated by reference in s. NR 440.17;
NR 440.642(7)(j)2.e. e. Have dimensions of 12.7 centimeters by 17.8 centimeters (5 inches by 7 inches) as described in 40 CFR part 60, Appendix I, section 2.1, incorporated by reference in s. NR 440.17 (1);
NR 440.642(7)(j)2.f. f. Have wording, presentation of the graphic data, and typography as presented in 40 CFR part 60, Appendix I, incorporated by reference in s. NR 440.17.
NR 440.642(7)(k)1.1. Each affected facility offered for sale by a commercial owner shall be accompanied by an owner's manual that shall contain the information listed in subds. 2. (pertaining to installation) and 3. (pertaining to operation and maintenance). The information shall be adequate to enable consumers to achieve optimal emissions performance. The information shall also be consistent with the operating instructions provided by the manufacturer to the laboratory for operating the wood heater during certification testing, except for details of the certification test that would not be relevant to the ultimate purchaser.
NR 440.642(7)(k)2. 2. Installation information in the owner's manual shall state the requirements for achieving proper draft.
NR 440.642(7)(k)3. 3. Operation and maintenance information in the owner's manual shall include:
NR 440.642(7)(k)3.a. a. Wood loading procedures, recommendations on wood selection, and warnings on what fuels not to use, such as treated wood, colored paper, cardboard, solvents, trash and garbage,
NR 440.642(7)(k)3.b. b. Fire starting procedures,
NR 440.642(7)(k)3.c. c. Proper use of air controls,
NR 440.642(7)(k)3.d. d. Ash removal procedures,
NR 440.642(7)(k)3.e. e. Instructions on gasket replacement,
NR 440.642(7)(k)3.f. f. For catalytic models, information on the following pertaining to the catalytic combustor:
1) Procedures for achieving and maintaining catalyst activity,
2) Maintenance procedures,
3) Procedures for determining deterioration or failure,
4) Procedures for replacement, and
5) Information on how to exercise warranty rights, and
NR 440.642(7)(k)3.g. g. For catalytic models, the following statement:
This wood heater contains a catalytic combustor, which needs periodic inspection and replacement for proper operation. It is against the law to operate this wood heater in a manner inconsistent with operating instructions in this manual, or if the catalytic element is deactivated or removed.
NR 440.642(7)(k)4. 4. Any manufacturer using the model language contained in 40 CFR part 60, Appendix I, incorporated by reference in s. NR 440.17, to satisfy any requirement of this paragraph shall be in compliance with that requirement, provided that the particular model language is printed in full, with only such changes as are necessary to ensure accuracy for the particular model line.
NR 440.642(7)(L) (L) Wood heaters that are affected by this section but that have been owned and operated by a noncommercial owner, are not subject to pars. (j) and (k) when offered for resale.
NR 440.642(8) (8)Reporting and recordkeeping.
Loading...
Loading...
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date the chapter was last published.