NR 670.280(1)(a)1.1. My existing facility complies with all applicable requirements of ch. NR 667 and shall continue to comply until the expiration of the license. NR 670.280(1)(a)2.2. My facility has been designed, and shall be constructed and operated to comply with all applicable requirements of ch. NR 667, and shall continue to comply until expiration of the license. NR 670.280(1)(b)(b) I shall make all information that I am required to maintain at my facility by ss. NR 670.290 to 670.315 readily available for review by the department and the public. NR 670.280(1)(c)(c) I shall continue to make all information required by ss. NR 670.290 to 670.315 available until the license expires. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violation.” NR 670.280(3)(3) This certification shall be based upon an audit that you conduct of your facility’s compliance status with ch. NR 667. A written audit report, signed and certified as accurate by the auditor, shall be submitted to the department with the s. NR 670.270 (2) notice of intent. NR 670.280 HistoryHistory: CR 16-007: cr. Register July 2017 No. 739, eff. 8-1-17; correction in (2) made under s. 13.92 (4) (b) 7., Stats., Register July 2017. NR 670.290NR 670.290 What general types of information shall I keep at my facility? Keep the following information at your facility: NR 670.290(2)(2) Chemical and physical analyses of the hazardous waste and hazardous debris handled at the facility. At a minimum, these analyses shall contain all the information you must know to treat or store the wastes properly under the requirements of ch. NR 667. NR 670.290(8)(8) A description of procedures, structures or equipment used at the facility to: NR 670.290(8)(a)(a) Prevent hazards in unloading operations (for example, use ramps, special forklifts). NR 670.290(8)(b)(b) Prevent runoff from hazardous waste handling areas to other areas of the facility or environment, or to prevent flooding (for example, with berms, dikes, trenches). NR 670.290(8)(e)(e) Prevent undue exposure of personnel to hazardous waste (for example, requiring protective clothing). NR 670.290(9)(9) A description of precautions to prevent accidental ignition or reaction of ignitable, reactive, or incompatible wastes as required by s. NR 667.0017. NR 670.290(10)(10) Traffic pattern, estimated volume (number, types of vehicles) and control (for example, show turns across traffic lanes and stacking lanes; describe access road surfacing and load bearing capacity; show traffic control signals). NR 670.290(12)(12) An outline of both the introductory and continuing training programs you will use to prepare employees to operate or maintain your facility safely as required by s. NR 667.0016. A brief description of how training will be designed to meet actual job tasks under s. NR 667.0016 (4) (c) requirements. NR 670.290(15)(15) The most recent closure cost estimate for your facility prepared under s. NR 667.0142 and a copy of the documentation required to demonstrate financial assurance under s. NR 667.0143. For a new facility, you may gather the required documentation 60 days before the initial receipt of hazardous wastes. NR 670.290(17)(17) Where applicable, a copy of the insurance policy or other documentation that complies with the liability requirements of s. NR 667.0147. For a new facility, documentation showing the amount of insurance meeting the specification of s. NR 667.0147 (1) that you plan to have in effect before initial receipt of hazardous waste for treatment or storage. NR 670.290(18)(18) A topographic map showing a distance of 1,000 feet around your facility at a scale of 2.5 centimeters (1 inch) equal to not more than 61.0 meters (200 feet). The map shall show elevation contours. The contour interval shall show the pattern of surface water flow in the vicinity of and from each operational unit of the facility. For example, contours with an interval of 1.5 meters (5 feet), if relief is greater than 6.1 meters (20 feet), or an interval of 0.6 meters (2 feet), if relief is less than 6.1 meters (20 feet). The map shall clearly show the following: NR 670.290(18)(d)(d) Surrounding land uses (residential, commercial, agricultural, recreational). NR 670.290(18)(j)(j) Buildings; treatment, storage, or disposal operations; or other structure (such as recreation areas, runoff control systems, access and internal roads, storm, sanitary and process sewerage systems, loading and unloading areas, and fire control facilities) NR 670.290(18)(L)(L) Location of operational units within your facility, where hazardous waste is (or will be) treated or stored. (Include equipment cleanup areas.) NR 670.290 HistoryHistory: CR 16-007: cr. Register July 2017 No. 739, eff. 8-1-17; correction in (12) made under s. 13.92 (4) (b) 7., Stats., Register July 2017 No. 739. NR 670.300NR 670.300 What container information shall I keep at my facility? If you store or treat hazardous waste in containers, keep the following information at your facility: NR 670.300(1)(1) A description of the containment system to demonstrate compliance with the container storage area provisions of s. NR 667.0173. This description shall show the following: NR 670.300(1)(a)(a) Basic design parameters, dimensions and materials of construction. NR 670.300(1)(b)(b) How the design promotes drainage or how containers are kept from contact with standing liquids in the containment system. NR 670.300(1)(c)(c) Capacity of the containment system relative to the number and volume of containers to be stored. NR 670.300(1)(e)(e) How accumulated liquids can be analyzed and removed to prevent overflow. NR 670.300(2)(2) For storage areas that store containers holding wastes that do not contain free liquids, a demonstration of compliance with s. NR 667.0173 (3), including: NR 670.300(2)(a)(a) Test procedures and results or other documentation or information to show that the wastes do not contain free liquids. NR 670.300(2)(b)(b) A description of how the storage area is designed or operated to drain and remove liquids or how containers are kept from contact with standing liquids. NR 670.300(3)(3) Sketches, drawings, or data demonstrating compliance with s. NR 667.0174 (location of buffer zone (15m or 50ft) and containers holding ignitable or reactive wastes) and s. NR 667.0175 (3) (location of incompatible wastes in relation to each other), where applicable. NR 670.300 HistoryHistory: CR 16-007: cr. Register July 2017 No. 739, eff. 8-1-17. NR 670.305NR 670.305 What tank information shall I keep at my facility? If you use tanks to store or treat hazardous waste, keep the following information at your facility: NR 670.305(1)(1) A written assessment that is reviewed and certified by an qualified professional engineer on the structural integrity and suitability for handling hazardous waste of each tank system, as required under ss. NR 667.0191 and 667.0192. NR 670.305(3)(3) Description of feed systems, safety cutoff, bypass systems, and pressure controls (for example, vents). NR 670.305(4)(4) A diagram of piping, instrumentation, and process flow for each tank system. NR 670.305(5)(5) A description of materials and equipment used to provide external corrosion protection, as required under s. NR 667.0191. NR 670.305(6)(6) For new tank systems, a detailed description of how the tank system or systems will be installed in compliance with ss. NR 667.0192 and 667.0194. NR 670.305(7)(7) Detailed plans and description of how the secondary containment system for each tank system is or will be designed, constructed and operated to meet the requirements of ss. NR 667.0195 and 667.0196. NR 670.305(9)(9) Description of controls and practices to prevent spills and overflows, as required under s. NR 667.0198. NR 670.305(10)(10) For tank systems in which ignitable, reactive, or incompatible wastes are to be stored or treated, a description of how operating procedures and tank system and facility design shall achieve compliance with the requirements of ss. NR 667.0202 and 667.0203. NR 670.305 HistoryHistory: CR 16-007: cr. Register July 2017 No. 739, eff. 8-1-17; correction in (4) made under s. 35.17, Stats., Register July 2017 No. 739. NR 670.310NR 670.310 What equipment information shall I keep at my facility? If your facility has equipment to which subch. BB of ch. NR 664 applies, keep the following information at your facility: NR 670.310(1)(a)(a) Equipment identification number and hazardous waste management unit identification. NR 670.310(1)(b)(b) Approximate locations within the facility (for example, identify the hazardous waste management unit on a facility plot plan). NR 670.310(1)(c)(c) Type of equipment (for example, a pump or a pipeline valve). NR 670.310(1)(d)(d) Percent by weight of total organics in the hazardous waste stream at the equipment. NR 670.310(1)(e)(e) Hazardous waste state at the equipment (for example, gas, vapor, or liquid). NR 670.310(1)(f)(f) Method of compliance with the standard (for example, monthly leak detection and repair or equipped with dual mechanical seals). NR 670.310(3)(3) Documentation that demonstrates compliance with the equipment standards in ss. NR 6264.1052 and 664.1059. This documentation shall contain the records required under s. NR 664.1064. NR 670.310(4)(a)(a) A list of all information references and sources used in preparing the documentation. NR 670.310(4)(c)(c) A design analysis, specifications, drawings, schematics and piping and instrumentation diagrams based on the appropriate sections of “Course 415: Control of Gaseous Emissions,” incorporated by reference in s. NR 660.11, or other engineering texts acceptable to the department that present basic control device design information. The design analysis shall address the vent stream characteristics and control device operation parameters as specified in s. NR 664.1035 (2) (d) 3. NR 670.310(4)(d)(d) A statement signed and dated by the owner or operator certifying that the operating parameters used in the design analysis reasonably represent the conditions that exist when the hazardous waste management unit is operating at the highest load or capacity level reasonable expected to occur. NR 670.310(4)(e)(e) A statement signed and dated by the owner or operator certifying that the control device is designed to operate at an efficiency of 95 weight percent or greater. NR 670.310 HistoryHistory: CR 16-007: cr. Register July 2017 No. 739, eff. 8-1-17. NR 670.315NR 670.315 What air emissions control information shall I keep at my facility? If you have air emission control equipment subject to subch. CC of ch. NR 664, keep the following information at your facility: NR 670.315(1)(1) Documentation for each floating roof cover installed on a tank subject to s. NR 664.1084 (4) (a) or (b) that includes information you prepared or the cover manufacturer or vendor provided describing the cover design, and your certification that the cover meets applicable design specifications listed in s. NR 664.1084 (5) (a) or (6) (a). NR 670.315(2)(2) Identification of each container area subject to the requirements of subch. CC of ch. NR 664 and your certification that the requirements of the subchapter are met. NR 670.315(3)(3) Documentation for each enclosure used to control air pollutant emissions from tanks or containers under requirements of s. NR 664.1084 (4) (e) or 664.1086 (5) (a) 2. Include records for the most recent set of calculations and measurements you performed to verify that the enclosure meets the criteria of a permanent total enclosure as specified in “Procedure T — Criteria for and Verification of a Permanent or Temporary Total Enclosure” under 40 CFR 52.741, Appendix B.
/exec_review/admin_code/nr/600/670
true
administrativecode
/exec_review/admin_code/nr/600/670/j/290/18/a
Department of Natural Resources (NR)
Chs. NR 600-699; Environmental Protection – Hazardous Waste Management
administrativecode/NR 670.290(18)(a)
administrativecode/NR 670.290(18)(a)
section
true