NR 662.204(3)(3) An eligible academic entity shall keep a copy of the withdrawal notice on file at the eligible academic entity for 3 years from the date of the notification. NR 662.204 HistoryHistory: CR 19-082: cr. Register August 2020 No. 776, eff. 9-1-20. NR 662.205NR 662.205 Summary of the requirements of this subchapter. An eligible academic entity that chooses to be subject to this subchapter is not required to have an interim or operating license issued under ch. NR 670 for the accumulation of unwanted material and hazardous waste in its laboratories, provided the laboratories comply with the provisions of this subchapter and the eligible academic entity has a laboratory management plan or LMP in accordance with s. NR 662.214 that describes how the laboratories owned by the eligible academic entity will comply with the requirements of this subchapter. NR 662.205 HistoryHistory: CR 19-082: cr. Register August 2020 No. 776, eff. 9-1-20. NR 662.206NR 662.206 Labeling and management standards for containers of unwanted material in the laboratory. An eligible academic entity shall manage containers of unwanted material while in the laboratory in accordance with all of the following requirements: NR 662.206(1)(1) Labeling. An eligible academic entity shall label unwanted material as follows: NR 662.206(1)(a)(a) All of the following information shall be affixed or attached to the container: NR 662.206(1)(a)1.1. The words “unwanted material” or another equally effective term that is to be used consistently by the eligible academic entity and that is identified in part I of the laboratory management plan. NR 662.206(1)(a)2.2. Sufficient information to alert emergency responders to the contents of the container. Examples of information that would be sufficient to alert emergency responders to the contents of the container include: NR 662.206(1)(a)2.b.b. The type or class of chemical, such as organic solvents or halogenated organic solvents. NR 662.206(1)(b)(b) The following information may be affixed or attached to the container, but shall at a minimum be associated with the container: NR 662.206(1)(b)1.1. The date that the unwanted material first began accumulating in the container. NR 662.206(1)(b)2.2. Information sufficient to allow a trained professional to properly identify whether an unwanted material is a solid or hazardous waste and to assign the proper hazardous waste code, under s. NR 662.011. Examples of information that would allow a trained professional to properly identify whether an unwanted material is a solid or hazardous waste include: NR 662.206(1)(b)2.a.a. The name and description of the chemical contents or composition of the unwanted material, or, if known, the product of the chemical reaction. NR 662.206(1)(b)2.c.c. A description of the manner in which the chemical was produced or processed, if applicable. NR 662.206(2)(2) Management of containers in the laboratory. An eligible academic entity shall properly manage containers of unwanted material in the laboratory to assure safe storage of the unwanted material, to prevent leaks, spills, emissions to the air, adverse chemical reactions, and dangerous situations that may result in harm to human health or the environment. Proper container management shall include all of the following: NR 662.206(2)(a)(a) Containers are maintained and kept in good condition and damaged containers are replaced, overpacked, or repaired. NR 662.206(2)(b)(b) Containers are compatible with their contents to avoid reactions between the contents and the container; and are made of, or lined with, material that is compatible with the unwanted material so that the container’s integrity is not impaired. NR 662.206(2)(c)(c) Containers shall be kept closed at all times, except for any of the following: NR 662.206(2)(c)2.2. A working container may be open until the end of the procedure or work shift, or until it is full, whichever comes first, at which time the working container shall either be closed or the contents emptied into a separate container that is then closed. NR 662.206(2)(c)3.3. When venting of a container is necessary under any of the following conditions: NR 662.206(2)(c)3.a.a. For the proper operation of laboratory equipment, such as with in-line collection of unwanted materials from high performance liquid chromatographs. NR 662.206 HistoryHistory: CR 19-082: cr. Register August 2020 No. 776, eff. 9-1-20. NR 662.207NR 662.207 Training. An eligible academic entity shall provide training to all individuals working in a laboratory at the eligible academic entity and maintain documentation, as follows: NR 662.207(1)(1) Training for laboratory workers and students shall be commensurate with their duties so they understand the requirements in this subchapter and can implement them. NR 662.207(2)(2) The required training under this subsection may include any of the following: NR 662.207(2)(a)(a) Instruction by the professor or laboratory manager before or during an experiment. NR 662.207(3)(3) An eligible academic entity that is a large quantity generator shall maintain documentation for the durations specified in s. NR 665.0016 (5) demonstrating training for all laboratory workers that is sufficient to determine whether laboratory workers have been trained. Examples of documentation demonstrating training include: NR 662.207(4)(4) A trained professional shall do all of the following: NR 662.207(4)(a)(a) Accompany the transfer of unwanted material and hazardous waste when the unwanted material and hazardous waste is removed from the laboratory. NR 662.207 HistoryHistory: CR 19-082: cr. Register August 2020 No. 776, eff. 9-1-20; correction in (4) (b) made under s. 35.17, Stats., Register August 2020 No. 776; correction in (3) (intro.) made under s. 13.92 (4) (b) 7., Stats., Register April 2021 No. 784. NR 662.208NR 662.208 Removing containers of unwanted material from the laboratory. NR 662.208(1)(1) Containers of unwanted material shall be removed on a regular schedule. An eligible academic entity shall comply with any of the following: NR 662.208(1)(a)(a) Remove all containers of unwanted material from each laboratory on a regular interval, not to exceed 12 months. NR 662.208(1)(b)(b) Remove containers of unwanted material from each laboratory within 12 months of each container’s accumulation start date. NR 662.208(2)(2) The eligible academic entity shall specify in part I of its laboratory management plan whether it will comply with sub. (1) (a) or (b) for the regular removal of unwanted material from its laboratories. NR 662.208(3)(3) The eligible academic entity shall specify in part II of its laboratory management plan how it will comply with sub. (1) (a) or (b) and develop a schedule for regular removals of unwanted material from its laboratories. NR 662.208(4)(4) An eligible academic entity shall remove containers of unwanted material when volumes are exceeded, using any of the following procedures that are applicable: NR 662.208(4)(a)(a) If a laboratory accumulates a total volume of unwanted material, including reactive acutely hazardous unwanted material, in excess of 55 gallons before the regularly scheduled removal, the eligible academic entity shall ensure that all containers of unwanted material in the laboratory, including reactive acutely hazardous unwanted material, are: NR 662.208(4)(a)1.1. Marked on the label that is associated with the container or on the label that is affixed or attached to the container with the date that 55 gallons is exceeded. NR 662.208(4)(a)2.2. Removed from the laboratory within 10 calendar days of the date that 55 gallons was exceeded, or at the next regularly scheduled removal, whichever comes first. NR 662.208(4)(b)(b) If a laboratory accumulates more than 1 quart of liquid reactive acutely hazardous unwanted material or more than 1 kg of solid reactive acutely hazardous unwanted material before the regularly scheduled removal, then the eligible academic entity shall ensure that all containers of reactive acutely hazardous unwanted material are: NR 662.208(4)(b)1.1. Marked on the label that is associated with the container or on the label that is affixed or attached to the container with the date that 1 quart or 1 kg is exceeded. NR 662.208(4)(b)2.2. Removed from the laboratory within 10 calendar days of the date that 1 quart or 1 kg was exceeded, or at the next regularly scheduled removal, whichever comes first. NR 662.208 HistoryHistory: CR 19-082: cr. Register August 2020 No. 776, eff. 9-1-20. NR 662.209NR 662.209 Where and when to make the hazardous waste determination and where to send containers of unwanted material upon removal from the laboratory. NR 662.209(1)(1) Large quantity generators and small quantity generators. An eligible academic entity shall ensure that a trained professional makes a hazardous waste determination, according to s. NR 662.011, for unwanted material in any of the following areas: NR 662.209(1)(a)(a) In the laboratory before the unwanted material is removed from the laboratory, in accordance with s. NR 662.210. NR 662.209(1)(c)(c) Within 4 calendar days of arriving at an on-site interim status or permitted treatment, storage, or disposal facility, in accordance with s. NR 662.212. NR 662.209(2)(2) Very small quantity generators. An eligible academic entity shall ensure that a trained professional makes a hazardous waste determination, according to s. NR 662.011 (1) to (4), for unwanted material in the laboratory before the unwanted material is removed from the laboratory, in accordance with s. NR 662.210. NR 662.209 HistoryHistory: CR 19-082: cr. Register August 2020 No. 776, eff. 9-1-20. NR 662.210NR 662.210 Making the hazardous waste determination in the laboratory before the unwanted material is removed from the laboratory. If an eligible academic entity makes the hazardous waste determination, according to s. NR 662.011 for unwanted material in the laboratory, it shall comply with all of the following: NR 662.210(1)(1) A trained professional shall make the hazardous waste determination, according to s. NR 662.011 (1) to (4), before the unwanted material is removed from the laboratory. NR 662.210(2)(2) If an unwanted material is a hazardous waste, the eligible academic entity shall do all of the following: NR 662.210(2)(a)(a) Write the words “hazardous waste” on the container label that is affixed or attached to the container before the hazardous waste may be removed from the laboratory. NR 662.210(2)(b)(b) Write the appropriate hazardous waste code on the label that is associated with the container or on the label that is affixed or attached to the container before the hazardous waste is transported off-site. NR 662.210(2)(c)(c) Count the hazardous waste toward the eligible academic entity’s generator category, according to s. NR 662.013, in the calendar month that the hazardous waste determination was made. NR 662.210(3)(3) A trained professional shall accompany all hazardous waste that is transferred from the laboratory to an on-site central accumulation area or on-site interim status or permitted treatment, storage, or disposal facility. NR 662.210(4)(4) When hazardous waste is removed from the laboratory, do any of the following that are applicable: NR 662.210(4)(a)(a) Large quantity generators and small quantity generators shall ensure the hazardous waste is taken directly from the laboratory to an on-site central accumulation area, or on-site interim status or permitted treatment, storage, or disposal facility, or transported off-site. NR 662.210(4)(b)(b) A very small quantity generator shall ensure the hazardous waste is taken directly from the laboratory to any of the types of facilities listed in s. NR 662.014. NR 662.210(5)(5) An unwanted material that is a hazardous waste is subject to all applicable hazardous waste regulations when it is removed from the laboratory. NR 662.210 HistoryHistory: CR 19-082: cr. Register August 2020 No. 776, eff. 9-1-20; correction in (1), (4) (a) made under s. 35.17, Stats., Register August 2020 No. 776. NR 662.211NR 662.211 Making the hazardous waste determination at an on-site central accumulation area. If an eligible academic entity makes the hazardous waste determination according to s. NR 662.011 for unwanted material at an on-site central accumulation area, it shall comply with all of the following: NR 662.211(1)(1) A trained professional shall accompany all unwanted material that is transferred from the laboratory to an on-site central accumulation area. NR 662.211(2)(2) All unwanted material removed from the laboratory shall be taken directly from the laboratory to the on-site central accumulation area. NR 662.211(3)(3) The unwanted material becomes subject to the generator accumulation regulations under s. NR 662.016 for small quantity generators or s. NR 662.017 for large quantity generators as soon as it arrives in the central accumulation area, except for the “hazardous waste” labeling conditions under ss. NR 662.016 (2) (f) and 662.017 (1) (e). NR 662.211(4)(4) A trained professional shall determine, according to s. NR 662.011 (1) to (4), if the unwanted material is a hazardous waste within 4 calendar days of the unwanted materials’ arrival at the on-site central accumulation area. NR 662.211(5)(5) If the unwanted material is a hazardous waste, the eligible academic entity shall do all of the following: NR 662.211(5)(a)(a) Write the words “hazardous waste” on the container label that is affixed or attached to the container within 4 calendar days of arriving at the on-site central accumulation area and before the hazardous waste may be removed from the on-site central accumulation area. NR 662.211(5)(b)(b) Write the appropriate hazardous waste code on the container label that is associated with the container or on the label that is affixed or attached to the container before the hazardous waste may be treated or disposed of on-site or transported off-site. NR 662.211(5)(c)(c) Count the hazardous waste toward the eligible academic entity’s generator category, according to s. NR 662.013 in the calendar month that the hazardous waste determination was made. NR 662.211(5)(d)(d) Manage the hazardous waste according to all applicable hazardous waste regulations.
/exec_review/admin_code/nr/600/662
true
administrativecode
/exec_review/admin_code/nr/600/662/k/207
Department of Natural Resources (NR)
Chs. NR 600-699; Environmental Protection – Hazardous Waste Management
administrativecode/NR 662.207
administrativecode/NR 662.207
section
true