NR 466.07(4)(a)2.j.j. If demonstrating compliance with sub. (2) (b), calculate the organic HAP emission rate based on material applied, S, using Equation 16. NR 466.07(4)(b)1.1. Under par. (a) 1., the affected source is in compliance with an emission limitation if one of the following is satisfied: NR 466.07(4)(b)1.a.a. The organic volatile matter collection and recovery efficiency, Rv, is 95% or greater. NR 466.07(4)(b)1.b.b. The organic HAP emission rate based on solids applied, L, is 0.20 kg (0.20 lb) organic HAP per kg (lb) solids applied or less. NR 466.07(4)(b)1.c.c. The organic HAP emission rate based on material applied, S, is 0.04 kg (0.04 lb) organic HAP per kg (lb) material applied or less. NR 466.07(4)(b)1.d.d. The organic HAP emitted during the month, H, is less than the calculated allowable organic HAP, Ha, as determined using sub. (6). NR 466.07(4)(b)2.2. Under par. (a) 2., the affected source is in compliance with an emission limitation if the capture system operating parameter is operated at an average value greater than or less than, as appropriate, the operating parameter value established in accordance with s. NR 466.10 (6) for each 3 hour period, and one of the following is satisfied: NR 466.07(4)(b)2.a.a. The organic volatile matter collection and recovery efficiency, Rv, is 95% or greater. NR 466.07(4)(b)2.b.b. The organic HAP emission rate based on solids applied, L, is 0.20 kg (0.20 lb) organic HAP per kg (lb) solids applied or less. NR 466.07(4)(b)2.c.c. The organic HAP emission rate based on material applied, S, is 0.04 kg (0.04 lb) organic HAP per kg (lb) material applied or less. NR 466.07(4)(b)2.d.d. The organic HAP emitted during the month, H, is less than the calculated allowable organic HAP, Ha, as determined using sub. (6). NR 466.07(5)(a)(a) To demonstrate the overall organic HAP control efficiency required under sub. (3) (g) or the organic HAP emission limitation requirements in sub. (3) (h) to (j), each owner or operator using an oxidizer to control emissions shall do one of the following: NR 466.07(5)(a)1.1. Conduct initial performance tests of capture efficiency and control device efficiency and continuously monitor capture system and control device operating parameters according to the following procedures: NR 466.07(5)(a)1.d.d. If demonstrating compliance with sub. (2) (b), (c) or (d), measure the mass of each ink, coating, varnish, adhesive, primer, solvent and other material applied on the press or group of presses controlled by a common solvent recovery device during the month. NR 466.07(5)(a)1.e.e. If demonstrating compliance with sub. (2) (b), (c) or (d), determine the organic HAP content of each ink, coating, varnish, adhesive, primer, solvent and other material applied during the month following the procedure in s. NR 466.09 (2) (b). NR 466.07(5)(a)1.f.f. If demonstrating compliance with sub. (2) (c) or (d), determine the solids content of each ink, coating, varnish, adhesive, primer, solvent and other material applied during the month following the procedure in s. NR 466.09 (3) (b). NR 466.07(5)(a)1.j.j. Install, calibrate, operate and maintain the instrumentation necessary to measure continuously the site-specific operating parameters established in accordance with s. NR 466.10 (5) and (6) whenever a product and packaging rotogravure or wide-web flexographic press is operating. NR 466.07(5)(a)2.2. Conduct continuous emission monitoring of the control device, conduct an initial performance test of capture efficiency, and continuously monitor a site specific operating parameter to assure capture efficiency in accordance with the requirements in sub. (4) (a) 2. NR 466.07(5)(b)1.1. Under par. (a) 1., the affected source is in compliance with an emission limitation if the oxidizer is operated such that the average operating parameter value is greater than the operating parameter value established in accordance with s. NR 466.10 (5) for each 3-hour period, and the capture system operating parameter is operated at an average value greater than or less than, as appropriate, the operating parameter value established in accordance with s. NR 466.10 (6) for each 3-hour period, and one of the following is satisfied: NR 466.07(5)(b)1.b.b. The organic HAP emission rate based on solids applied, L, is 0.20 kg (0.20 lb) organic HAP per kg (lb) solids applied or less. NR 466.07(5)(b)1.c.c. The organic HAP emission rate based on material applied, S, is 0.04 kg (0.04 lb) organic HAP per kg (lb) material applied or less. NR 466.07(5)(b)1.d.d. The organic HAP emitted during the month, H, is less than the calculated allowable organic HAP, Ha, as determined using sub. (6). NR 466.07(6)(6) Calculating monthly allowable hap emissions (Ha). Owners or operators shall calculate the monthly allowable HAP emissions, Ha, as required under sub. (3) (f), (4) (b) 1. d. or 2. d., or (5) (b) 1. d., according to the following procedures: NR 466.07(6)(a)(a) Determine the as-purchased mass of each ink, coating, varnish, adhesive, primer and other solids-containing material applied each month, Mi. NR 466.07(6)(b)(b) Determine the as-purchased solids content of each ink, coating, varnish, adhesive, primer and other solids-containing material applied each month, in accordance with s. NR 466.09 (3) (b), Csi. NR 466.07(6)(c)(c) Determine the as-purchased mass fraction of each ink, coating, varnish, adhesive, primer and other solids-containing material which was applied at 20% by weight or greater solids content, on an as-applied basis, Gi. NR 466.07(6)(d)(d) Determine the total mass of each solvent, diluent, thinner or reducer added to materials which were applied at less than 20% by weight solids content, on an as-applied basis, each month, MLj. NR 466.07(6)(e)(e) Calculate the monthly allowable HAP emissions, Ha, using Equation 17. NR 466.07(7)(7) Operating more than one capture system or control device, or one or more never-controlled or intermittently-controllable work stations. This subsection applies to owners or operators of product and packaging rotogravure or wide-web flexographic printing presses operating more than one capture system, more than one control device, one or more never-controlled work stations, or one or more intermittently-controllable work stations. NR 466.07(7)(a)(a) The owner or operator of each solvent recovery system used to control one or more product and packaging rotogravure or wide-web flexographic presses for which the owner or operator chooses to perform a liquid-liquid material balance under sub. (4) (a) 1. shall determine the organic HAP emissions for those presses controlled by that solvent recovery system according to one of the following: NR 466.07(7)(a)2.2. In accordance with subs. (4) (a) 1. b., c., e. and f. and (8), if the presses controlled by that solvent recovery system have one or more never-controlled or intermittently-controllable work stations. NR 466.07(7)(b)(b) The owner or operator of each solvent recovery system used to control one or more product and packaging rotogravure or wide-web flexographic presses, for which the owner or operator chooses to conduct continuous emission monitoring of the control device, conduct an initial test of capture efficiency, and continuously monitor a site specific operating parameter to assure capture efficiency under sub. (4) (a) 2., shall do both of the following: NR 466.07(7)(b)1.1. For each capture system delivering emissions to that solvent recovery system, monitor an operating parameter established in accordance with s. NR 466.10 (6) to assure capture system efficiency. NR 466.07(7)(b)2.2. Determine the organic HAP emissions for those presses served by each capture system delivering emissions to that solvent recovery system according to one of the following: NR 466.07(7)(b)2.b.b. In accordance with subs. (4) (a) 2. b., c. and e. to g. and (8), if the presses served by that capture system have one or more never-controlled or intermittently-controllable work stations. NR 466.07(7)(c)(c) The owner or operator of each oxidizer used to control emissions from one or more product and packaging rotogravure or wide-web flexographic presses, for which the owner or operator chooses to conduct performance tests of capture efficiency and control device efficiency and continuously monitor capture system and control device operating parameters under sub. (5) (a) 1., shall do all of the following: NR 466.07(7)(c)2.2. For each capture system delivering emissions to that oxidizer, monitor an operating parameter established in accordance with s. NR 466.10 (6) to assure capture efficiency. NR 466.07(7)(c)3.3. Determine the organic HAP emissions for those presses served by each capture system delivering emissions to that oxidizer according to one of the following: NR 466.07(7)(c)3.b.b. In accordance with subs. (5) (a) 1. a. to c. and e. and (8), if the presses served by that capture system have one or more never-controlled or intermittently-controllable work stations. NR 466.07(7)(d)(d) The owner or operator of each oxidizer used to control emissions from one or more product and packaging rotogravure or wide-web flexographic presses, for which the owner or operator chooses to conduct continuous emission monitoring of the control device, conduct an initial performance test of capture efficiency and continuously monitor a site specific operating parameter to assure capture efficiency under sub. (5) (a) 2., shall do both of the following: NR 466.07(7)(d)1.1. For each capture system delivering emissions to that oxidizer, monitor an operating parameter established in accordance with s. NR 466.10 (6) to assure capture efficiency. NR 466.07(7)(d)2.2. Determine the organic HAP emissions for those presses served by each capture system delivering emissions to that oxidizer according to one of the following: NR 466.07(7)(d)2.b.b. In accordance with subs. (4) (a) 2. b., c., e. to g. and (8), if the presses served by that capture system have one or more never-controlled or intermittently-controllable work stations. NR 466.07(7)(e)(e) The owner or operator of one or more uncontrolled product and packaging rotogravure or wide-web flexographic printing presses shall determine the organic HAP applied on those presses using Equation 8 in sub. (3) (f). For the purpose of a determination under this paragraph, the organic HAP emitted from an uncontrolled press shall be considered equal to the organic HAP applied on that press. NR 466.07(7)(f)(f) If demonstrating compliance with sub. (2) (c) or (d), the owner or operator shall determine the solids content of each ink, coating, varnish, adhesive, primer, solvent and other material applied during the month following the procedure in s. NR 466.09 (3) (b). NR 466.07(7)(g)(g) The owner or operator shall determine the organic HAP emissions for the affected source for the month by summing all organic HAP emissions calculated according to pars. (a), (b) 2., (c) 3., (d) 2. and (e). NR 466.07(7)(h)(h) Under this subsection, the affected source is in compliance for the month with an emission limitation, if all operating parameters required to be monitored under pars. (b) to (d), were maintained at the appropriate values, and one of the following is satisfied: NR 466.07(7)(h)1.1. The total mass of organic HAP emitted by the affected source was not more than 4% of the total mass of inks, coatings, varnishes, adhesives, primers, solvents, diluents, reducers, thinners and other materials applied by the affected source. NR 466.07(7)(h)2.2. The total mass of organic HAP emitted by the affected source was not more than 20% of the total mass of solids applied by the affected source. NR 466.07(7)(h)3.3. The total mass of organic HAP emitted by the affected source was not more than the equivalent allowable organic HAP emissions for the affected source, Ha, calculated in accordance with sub. (6). NR 466.07(7)(h)4.4. The total mass of organic HAP emitted by the affected source was not more than 5% of the total mass of organic HAP applied by the affected source. The total mass of organic HAP applied by the affected source in the month shall be determined by the owner or operator using Equation 8 in sub. (3) (f). NR 466.07(8)(8) Operating never-controlled or intermittently controllable work stations. Owners or operators determining organic HAP emissions from a press or group of presses having one or more never-controlled or intermittently-controllable work stations and using the procedures specified in sub. (7) (a) 2., (b) 2. b., (c) 3. b. or (d) 2. b., shall do the following for that press or group of presses: NR 466.07(8)(a)(a) Determine the sum of the mass of all inks, coatings, varnishes, adhesives, primers and other solids-containing materials which are applied on intermittently-controllable work stations in bypass mode and the mass of all inks, coatings, varnishes, adhesives, primers and other solids-containing materials which are applied on never-controlled work stations during the month, MBi. NR 466.07(8)(b)(b) Determine the sum of the mass of all solvents, reducers, thinners and other diluents which are applied on intermittently-controllable work stations in bypass mode and the mass of all solvents, reducers, thinners and other diluents which are applied on never-controlled work stations during the month, MBj. NR 466.07(8)(c)(c) Determine the sum of the mass of all inks, coatings, varnishes, adhesives, primers and other solids-containing materials which are applied on intermittently-controllable work stations in controlled mode and the mass of all inks, coatings, varnishes, adhesives, primers and other solids-containing materials which are applied on always-controlled work stations during the month, Mci. NR 466.07(8)(d)(d) Determine the sum of the mass of all solvents, reducers, thinners and other diluents which are applied on intermittently-controllable work stations in controlled mode and the mass of all solvents, reducers, thinners and other diluents which are applied on always-controlled work stations during the month, MCj. NR 466.07(8)(e)(e) For each press or group of presses for which the owner or operator uses the provisions of sub. (7) (a) 2., calculate the organic HAP emitted during the month using Equation 18. NR 466.07(8)(f)(f) For each press or group of presses for which the owner or operator uses the provisions of sub. (7) (b) 2. b., (c) 3. b. or (d) 2. b., the owner or operator shall calculate the organic HAP emitted during the month using Equation 19. NR 466.07(9)(9) Operating more than one capture system or control device and no never-controlled and no intermittently controllable work stations. If the owner or operator of an affected source operates more than one capture system or more than one control device, and has no never-controlled work stations and no intermittently-controllable work stations, the affected source is in compliance with the 95% overall organic HAP control efficiency requirement for the month if for each press or group of presses controlled by a common control device one of the following is satisfied: NR 466.07(9)(a)(a) The organic volatile matter collection and recovery efficiency, Rv, as determined by sub. (4) (a) 1. a., c. and e. to g., is equal to or greater than 95%. NR 466.07(9)(b)(b) The overall organic HAP control efficiency as determined by sub. (4) (a) 2. c. and e. to g., for each press or group of presses served by that control device and a common capture system, is equal to or greater than 95% and the average capture system operating parameter value for each capture system serving that control device is greater than or less than, as appropriate, the operating parameter value established for that capture system in accordance with s. NR 466.10 (6) for each 3-hour period. NR 466.07(9)(c)(c) The overall organic HAP control efficiency as determined by sub. (5) (a) 1. a. to c. and j., for each press or group of presses served by that control device and a common capture system, is equal to or greater than 95%, the oxidizer is operated such that the average operating parameter value is greater than the operating parameter value established in accordance with s. NR 466.10 (5) for each 3-hour period, and the average capture system operating parameter value for each capture system serving that control device is greater than or less than, as appropriate, the operating parameter value established for that capture system in accordance with s. NR 466.10 (6) for each 3-hour period. NR 466.07 HistoryHistory: Cr. Register, March, 2000, No. 531, eff. 4-1-00. NR 466.08(1)(1) The owner or operator of an existing source subject to this chapter shall comply with the provisions of this chapter on or before May 30, 1999. NR 466.08(2)(2) The owner or operator of a new MACT source subject to this chapter shall comply with the provisions of this chapter immediately upon startup of the affected source, or May 30, 1996, whichever is later. NR 466.08(3)(3) Affected sources which have undergone reconstruction are subject to the requirements for new MACT sources. The costs associated with the purchase and installation of air pollution control equipment are not considered in determining whether the affected source has been reconstructed. Additionally, the costs of retrofitting and replacement of equipment that is installed specifically to comply with this chapter are not considered reconstruction costs. NR 466.08 NoteNote: Compliance dates are federally enforceable under 40 CFR 63.826 prior to the effective date of this section.
/exec_review/admin_code/nr/400/466
true
administrativecode
/exec_review/admin_code/nr/400/466/i/07/5/b/1/a
Department of Natural Resources (NR)
Chs. NR 400-499; Environmental Protection – Air Pollution Control
administrativecode/NR 466.07(5)(b)1.a.
administrativecode/NR 466.07(5)(b)1.a.
section
true