NR 447.13(2)(a)(a) All asbestos-containing waste material shall be deposited as soon as is practical by the waste generator at: NR 447.13(2)(a)2.2. An EPA-approved site that converts RACM and asbestos-containing waste material into nonasbestos (asbestos-free) material according to the provisions of s. NR 447.18. NR 447.13(2)(b)(b) The requirements of this subsection do not apply to Category I nonfriable ACM that is not RACM. NR 447.13(3)(3) Mark vehicles used to transport asbestos-containing waste material during the loading and unloading of waste so that the signs are visible. The markings shall conform to the requirements of s. NR 447.12 (4) (a) 1. to 3. NR 447.13(4)(4) For all asbestos-containing waste material transported off the facility site: NR 447.13(4)(a)(a) Maintain waste shipment records, using a format acceptable to department, and include the following information: NR 447.13(4)(a)2.2. The name and address of the department staff person responsible for administering this chapter. NR 447.13(4)(a)8.8. A certification that the contents of this consignment are fully and accurately described by proper shipping name and are classified, packed, marked and labeled, and are in all respects in proper condition for transport by highway according to applicable international, federal, state and local regulations. NR 447.13(4)(b)(b) Provide a copy of the waste shipment record, described in par. (a), to the disposal site owners or operators at the same time as the asbestos-containing waste material is delivered to the disposal site. NR 447.13(4)(c)(c) For waste shipments where a copy of the waste shipment record, signed by the owner or operator of the designated disposal site, is not received by the waste generator within 35 days of the date the waste was accepted by the initial transporter, contact the transporter or the owner or operator of the designated disposal site or both to determine the status of the waste shipment. NR 447.13(4)(d)(d) Report in writing to the department if a copy of the waste shipment record, signed by the owner or operator of the designated waste disposal site, is not received by the waste generator within 45 days of the date the waste was accepted by the initial transporter. Include in the report the following information: NR 447.13(4)(d)1.1. A copy of the waste shipment record for which a confirmation of delivery was not received. NR 447.13(4)(d)2.2. A cover letter signed by the waste generator explaining the efforts taken to locate the asbestos waste shipment and the results of those efforts. NR 447.13(4)(e)(e) Retain a copy of all waste shipment records, including a copy of the waste shipment record signed by the owner or operator of the designated waste disposal site, for at least 2 years. NR 447.13(5)(5) Furnish upon request, and make available for inspection by the department, all records required under this section. NR 447.13 HistoryHistory: Cr. Register, October, 1992, No. 442, eff. 11-1-92; am. (1) (a) 4., Register, December, 1995, No. 480, eff. 1-1-96; am. (1) (a) 4., Register, November, 1999, No. 527, eff. 12-1-99; CR 02-146: am. (1) (a) 4. Register October 2003 No. 574, eff. 11-1-03. NR 447.14NR 447.14 Inactive waste disposal sites for asbestos mills and manufacturing and fabricating operations. Each owner or operator of any inactive waste disposal site that was operated by sources covered under s. NR 447.03, 447.05 or 447.10 and received deposits of asbestos-containing waste material generated by the sources, shall: NR 447.14(1)(a)(a) Discharge no visible emissions to the outside air from an inactive waste disposal site subject to this section. NR 447.14(1)(b)(b) Cover the asbestos-containing waste material with at least 15 centimeters (6 inches) of compacted nonasbestos-containing material, and grow and maintain a cover of vegetation on the area adequate to prevent exposure of the asbestos-containing waste material. In desert areas where vegetation would be difficult to maintain, at least 8 additional centimeters (3 inches) of well-graded, nonasbestos crushed rock may be placed on top of the final cover instead of vegetation and maintained to prevent emissions. NR 447.14(1)(c)(c) Cover the asbestos containing waste material with at least 60 centimeters (2 feet) of compacted nonasbestos-containing material, and maintain it to prevent exposure of the asbestos-containing waste. NR 447.14(1)(d)(d) For inactive waste disposal sites for asbestos tailings, a resinous or petroleum-based dust suppression agent that effectively binds dust to control surface air emissions may be used instead of the methods in pars. (a) to (c). Use the agent in the manner and frequency recommended for the particular asbestos tailings by the manufacturer of the dust suppression agent to achieve and maintain dust control. Obtain prior written approval of the department to use other equally effective dust suppression agents. For purposes of this paragraph, any used, spent or other waste oil is not considered a dust suppression agent. NR 447.14(2)(2) Unless a natural barrier adequately deters access by the general public, install and maintain warning signs and fencing as follows, or comply with sub. (1) (b). NR 447.14(2)(a)(a) Display warning signs at all entrances and at intervals of 100 m (328 feet) or less along the property line of the site or along the perimeter of the sections of the site where asbestos-containing waste material was deposited. The warning signs shall conform with all the following: NR 447.14(2)(a)1.1. Be posted in such a manner and location that a person can easily read the legend. NR 447.14(2)(a)3.3. Display the following legend in the lower panel with letter sizes and styles of a visibility at least equal to those specified in this paragraph. NR 447.14(2)(b)(b) Fence the perimeter of the site in a manner adequate to deter access by the general public. NR 447.14(2)(c)(c) When requesting a determination on whether a natural barrier adequately deters public access, supply information enabling the department to determine whether a fence or a natural barrier adequately deters access by the general public. NR 447.14(3)(3) The owner or operator may use an alternative control method that has received prior approval of the administrator rather than comply with the requirements of sub. (1) or (2). NR 447.14(4)(4) Notify the department in writing at least 45 days prior to excavating or otherwise disturbing any asbestos-containing waste material that has been deposited at a waste disposal site under this section, and follow the procedures specified in the notification. If the excavation will begin on a date other than the one contained in the original notice, notice of the new start date shall be provided to the department at least 10 working days before excavation begins and in no event may excavation begin earlier than the date specified in the original notification. Include the following information in the notice: NR 447.14(4)(c)(c) Procedures to be used to control emissions during the excavation, storage, transport and ultimate disposal of the excavated asbestos-containing waste material. If deemed necessary, the department may require changes in the emission control procedures to be used. NR 447.14(4)(d)(d) Location of any temporary storage site and the final disposal site. NR 447.14(5)(5) After November 1, 1992, within 60 days of a site becoming inactive, record, in accordance with ch. 706, Stats., a notation on the deed to the facility property and on any other instrument that would normally be examined during a title search; this notation shall in perpetuity notify any potential purchaser of the property that: NR 447.14(5)(a)(a) The land has been used for the disposal of asbestos-containing waste material. NR 447.14(5)(b)(b) The survey plot and record of the location and quantity of asbestos-containing waste disposed of within the disposal site required in s. NR 447.17 (6) have been filed with the department. NR 447.14 HistoryHistory: Cr. Register, October, 1992, No. 442, eff. 11-1-92; am. (2) (a) 2., Register, December, 1995, No. 480, eff. 1-1-96. NR 447.15(1)(a)(a) Use fabric filter collection devices, except as noted in sub. (2), doing all of the following: NR 447.15(1)(a)1.1. Ensuring that the airflow permeability, as determined by ASTM Method D737-96, incorporated by reference in s. NR 484.10 (10), does not exceed 9 m3/min/m2 (30 ft3min/ft2) for woven fabrics or 11 m3/min/m2 (35 ft3/min/ft2) for felted fabrics, except that 12 m3/min/m2 (40 ft3/min/ft2) for woven and 14 m3/min/m2 (45 ft3/min/ft2) for felted fabrics is allowed for filtering air from asbestos ore dryers. NR 447.15(1)(a)2.2. Ensuring that felted fabric weighs at least 475 grams per square meter (14 ounces per square yard) and is at least 1.6 millimeter (one-sixteenth inch) thick throughout. NR 447.15(1)(a)3.3. Avoiding the use of synthetic fabrics that contain fill yarn other than that which is spun. NR 447.15(1)(b)(b) Properly install, use, operate and maintain all air-cleaning equipment authorized by this section. Bypass devices may be used only during upset or emergency conditions and then only for so long as it takes to shut down the operation generating the particulate asbestos material. NR 447.15(1)(c)(c) For fabric filter collection devices installed after January 10, 1989, provide for easy inspection for faulty bags. NR 447.15(2)(a)(a) If the use of fabric creates a fire or explosion hazard, or the department determines that a fabric filter is not feasible, the department may authorize as a substitute the use of wet collectors designed to operate with a unit contacting energy of at least 9.95 kilopascals (40 inches water gage pressure). NR 447.15(2)(b)(b) Use of a High Efficiency Particulate Air (HEPA) filter that is certified to be at least 99.97% efficient for 0.3 micron particles. NR 447.15(2)(c)(c) Use of an alternative filtering equipment that has received prior authorization from the administrator. NR 447.15 HistoryHistory: Cr. Register, October, 1992, No. 442, eff. 11-1-92; am. (1) (a) 1., Register, December, 1995, No. 480, eff. 1-1-96; am. (1) (a) 1., Register, November, 1999, No. 527, eff. 12-1-99. NR 447.16(1)(1) Any new source to which this chapter applies, with the exception of sources subject to ss. NR 447.04, 447.06, 447.07, 447.08, 447.09 and 447.11, which has an initial startup date preceding November 1, 1992, shall provide the information required in this subsection to the department postmarked or delivered within 90 days of November 1, 1992. In the case of a new source that does not have an initial startup date preceding November 1, 1992, the information shall be provided, postmarked or delivered, within 90 days of the initial startup date. Any owner or operator of an existing source shall provide the following information to the department within 90 days of November 1, 1992 unless the owner or operator of the existing source has previously provided this information to the department. Any changes in the information provided by any existing source shall be provided to the department, postmarked or delivered, within 30 days after the change. The information shall include: NR 447.16(1)(a)(a) A description of the emission control equipment used for each process; NR 447.16(1)(b)1.1. The airflow permeability in m3/min/m2 (ft3/min/ft2) if the fabric filter device uses a woven fabric and, if the fabric is synthetic, whether the fill yarn is spun or not spun; and NR 447.16(1)(b)2.2. If the fabric filter device uses a felted fabric, the density in g/m2 (oz/yd2), the minimum thickness in millimeters (inches), and the airflow permeability in m3/min/m2 (ft3/min/ft2); NR 447.16(1)(c)(c) If a High Efficiency Particulate Air (HEPA) filter is used to control emissions, the certified efficiency of the filter. NR 447.16(1)(d)1.1. A brief description of each process that generates asbestos-containing waste material. NR 447.16(1)(d)2.2. The average volume of asbestos-containing waste material disposed of, measured in m3/day (yd3/day). NR 447.16(1)(d)3.3. The emission control methods used in all stages of waste disposal. NR 447.16(1)(d)4.4. The type of disposal site or incineration site used for ultimate disposal, the name of the site operator, and the name and location of the disposal site. NR 447.16(1)(e)2.2. The method or methods used to comply with the standard or alternative procedures to be used. NR 447.16(2)(2) The information required by sub. (1) shall accompany the information required by 40 CFR 61.10 as in effect on January 1, 1998. Active waste disposal sites subject to s. NR 447.17 shall also comply with this provision. Roadways, demolition and renovation, spraying and insulating materials are exempted from the requirements of 40 CFR 61.10 (a). The information described in this section shall be reported using the format of Appendix A of 40 CFR part 61, incorporated by reference in s. NR 484.04 (22), as a guide. NR 447.16 HistoryHistory: Cr. Register, October, 1992, No. 442, eff. 11-1-92; am. (2), Register, December, 1995, No. 480, eff. 1-1-96; am. (2), Register, January 1997, No. 493, eff. 2-1-97; am. (2), Register, November, 1999, No. 527, eff. 12-1-99. NR 447.17NR 447.17 Active waste disposal sites. Each owner or operator of an active waste disposal site that receives asbestos-containing waste material from a source covered under s. NR 447.12, 447.13 or 447.18 shall meet the following requirements: NR 447.17(1)(1) Either there shall be no visible emissions to the outside air from any active waste disposal site where asbestos-containing waste material has been deposited, or the requirements of sub. (3) or (4) shall be met. NR 447.17(2)(2) Unless a natural barrier exists, either warning signs and fencing shall be installed and maintained as follows, or the requirements of sub. (3) (a) shall be met. NR 447.17(2)(a)(a) Warning signs shall be displayed at all entrances and at intervals of 100 m (330 ft) or less along the property line of the site or along the perimeter of the sections of the site where asbestos-containing waste material is deposited. The warning signs shall: NR 447.17(2)(a)1.1. Be posted in such a manner and location that a person can easily read the legend; NR 447.17(2)(a)3.3. Display the following legend in the lower panel with letter sizes and styles of a visibility at least equal to those specified in this paragraph. NR 447.17(2)(b)(b) The perimeter of the disposal site shall be fenced in a manner adequate to deter access by the general public. NR 447.17(2)(c)(c) Upon request and supply of appropriate information, the department shall determine whether a fence or a natural barrier adequately deters access by the general public. NR 447.17(3)(3) Rather than meet the no visible emission requirement of sub. (1), at the end of each operating day, or at least once every 24-hour period while the site is in continuous operation, the asbestos-containing waste material that has been deposited at the site during the operating day or previous 24-hour period shall: NR 447.17(3)(a)(a) Be covered with at least 15 centimeters (6 inches) of compacted nonasbestos containing material, or
/exec_review/admin_code/nr/400/447
true
administrativecode
/exec_review/admin_code/nr/400/447/14/1/d
Department of Natural Resources (NR)
Chs. NR 400-499; Environmental Protection – Air Pollution Control
administrativecode/NR 447.14(1)(d)
administrativecode/NR 447.14(1)(d)
section
true