This is the preview version of the Wisconsin State Legislature site.
Please see http://docs.legis.wisconsin.gov for the production version.
NR 446.18(4)(a)(a) Calculate the annual gross electric output in gigawatt-hours, according to Equation 4, as the sum of gross electric output measured in megawatt-hours for each hour the EGU is operating.
å
=
=
  Equation 4
where:
EGWh is the total annual gross electric output in GWh
MWhi is the gross electric output in MWh for each hour i the EGU operated during the compliance year
1,000 is the factor to convert MWh to GWh
n is the number of hours the EGU operated during the compliance year
NR 446.18(4)(b)(b) Calculate the annual amount of useful thermal energy in mmBtu, according to Equation 5, as the sum of the process thermal energy input for each hour the EGU is operated multiplied by the process energy efficiency.
å
=
÷
ø
ö
ç
è
æ
´
=
  Equation 5
where:
UTEannual is the annual amount of thermal energy, in mmBtu, utilized in the cogeneration process
PTEIi is the amount of thermal energy input, in mmBtu, made available to the cogeneration process for each hour i the EGU operated during the compliance year
PEE is the process energy efficiency, expressed as a percent, measured for the EGU. A value of 50% may be assumed.
n is the number of hours the unit operated during the year of compliance
NR 446.18(4)(c)(c) Calculate the annual gross energy output in mmBtu, according to Equation 6, as the sum of the annual gross electric output and the annual applied thermal energy converted to electric output.
+
=
  Equation 6
where:
GEOGWh is the total annual gross energy output in GWh
EGWh is the total annual gross electric output in GWh determined in par. (a)
UTEannual is the total annual useful thermal energy in mmBtu determined in par. (b)
3,413 is the factor to convert thermal energy in mmBtu to GWh
NR 446.18(5)(5)Determining annual allowable emissions. Except as provided in s. NR 446.185, owners and operators of a coal-fired EGU affected by this subchapter shall determine annual allowable emissions, as required to demonstrate compliance, according to the following procedures:
NR 446.18(5)(a)(a) When achieving compliance on a unit-by-unit basis, use one of the following equations as applicable:
NR 446.18(5)(a)1.1. For a percent reduction mercury emission limitation, Equation 7.
´
=
  Equation 7
where:
Hgallowable is the mass of mercury emissions allowed for the compliance year
Fuel Hgannual is the mass of mercury in fuel combusted during the compliance year as determined in sub. (3) (b).
Hg CE is the applicable requirement for percent mercury emission reduction divided by 100.
NR 446.18(5)(a)2.2. For a mercury output emission limitation, Equation 8.
´
=
  Equation 8
where:
Hgallowable is the mass of mercury emissions in pounds allowed for the compliance year
GEOGWh is the annual gross energy output during the compliance year as determined in sub. (4) (c)
ELoutput is the applicable mercury output based emission limitation in pounds per GWh
NR 446.18(5)(a)3.3. For an NOx or SO2 emission limitation, Equation 9.
´
=
å
=
  Equation 9
where:
Pallowable is the mass of NOx or SO2 emissions allowed for the compliance year
HIi is the amount of fuel, in mmBtu combusted each hour i, during the compliance year
h is the number of hours fuel is combusted during the compliance year
ELp is the applicable emission limitation of s. NR 446.14 (1) for NOx or SO2
NR 446.18(5)(b)(b) When achieving compliance using unit averaging as allowed under s. NR 446.13 (2) (b) or 446.14 (2) (b), according to Equation 10:
å
=
=
  Equation 10
where:
Unit Averaging Pallowable is the mass of mercury, NOx, or SO2 emissions allowed for each pollutant determined in par. (a) for each EGU participating in emissions averaging during the compliance year
Pu is the lowest annual allowable mass of mercury, NOx or SO2 emissions allowed for the compliance year for each EGU as determined under par. (a) or applicable under any other enforceable state or federal requirement for each EGU participating in emissions averaging during the compliance year
n is the number of EGUs participating in emissions averaging
NR 446.18 HistoryHistory: CR 07-036: cr. Register November 2008 No. 635, eff. 12-1-08.
NR 446.185NR 446.185Compliance alternatives.
NR 446.185(1)(1)Alternative annual allowable mercury emissions.
NR 446.185(1)(a)(a) Owners and operators of a coal-fired EGU affected by this subchapter may use baseline mercury emissions approved by the department as an alternative to procedures in s. NR 446.18 (5) (a) in determining annual allowable mercury emissions.
NR 446.185(1)(b)(b) Baseline mercury emissions shall be determined and used for calculating annual allowable mercury emissions for 5-year periods beginning with the period of 2016 to 2020. Baseline mercury emissions shall be determined every 5 years and used to calculate annual allowable mercury emissions for the subsequent 5-year period.
NR 446.185(1)(c)(c) Baseline mercury emissions for each 5-year period shall be determined using fuel mercury content data measured for the calendar year which is 2 years prior to the first year of the applicable 5-year period. The year designated for measuring fuel mercury content is the baseline determination year.
NR 446.185 NoteNote: Baseline emissions are measured for 2013 for determining the annual allowable emissions for compliance years 2015 to 2019, measured for 2018 for determining allowable emissions for compliance years 2020 through 2024, etc.
NR 446.185(1)(d)(d) No later than May 1 of the calendar year after the baseline determination year, the owner or operator of a coal-fired EGU shall submit a report to the department that includes information necessary to determine the baseline mercury emissions for that 5-year period.
NR 446.185(1)(e)(e) In the report required under par. (d), the owners or operators of a coal-fired EGU may request alternative data be used for determining baseline emissions if the data for the specified year is not representative of the EGU’s normal operations or maintenance schedule.
NR 446.185(1)(f)(f) Baseline mercury emissions for each EGU shall be determined according to the following procedures:
NR 446.185(1)(f)1.1. Measure and determine the fuel mercury content according to requirements of s. NR 446.18 (3) for all fuels combusted in the EGU for the baseline determination year.
NR 446.185(1)(f)2.2. Calculate the baseline mercury concentration, on a mmBtu-basis, for the baseline determination year according to Equation 11.
å
=
=
  Equation 11
where:
BMC is the average baseline mercury concentration of fuel, in pounds per mmBtu, contained in the fuels combusted in the EGU during the baseline determination year
Fuel Hgannual is the total mass of mercury contained in the fuel determined in subd. 1.
HIi is the total amount of fuel, in mmBtu, consumed each hour i, during the baseline determination year
h is the total number of hours fuel is consumed during the baseline determination year
NR 446.185(1)(f)3.3. Calculate the baseline mercury emissions according to Equation 12 as the baseline mercury concentration times the 3-year average of annual fuel consumption, in mmBtu, for the baseline determination year and 2 years prior to the baseline determination year.
å
å
=
÷
÷
ø
ö
ç
ç
æ
´
=
è
  Equation 12
where:
BME is the baseline mercury emissions for the EGU in pounds
BMC is the baseline mercury concentration for the EGU determined in subd. 2., in pounds per mmBtu.
HIi is the amount of fuel, in mmBtu combusted in the EGU for each hour i during each year y
h is the total number of hours fuel is combusted in the EGU during each year
NR 446.185(1)(g)(g) When determining annual allowable mercury emissions for achieving compliance on a unit-by-unit basis, use one of the following equations as applicable:
NR 446.185(1)(g)1.1. For a percent reduction mercury emission limitation, Equation 13.
´
=
  Equation 13
where:
Hgallowable is the mass of mercury emissions allowed for the EGU for the compliance year
BME is the baseline emissions for the EGU as determined in par. (f) 3.
Hg CE is the applicable requirement for percent mercury emission reduction divided by 100.
NR 446.185(1)(g)2.2. For a mercury output emission limitation, Equation 14.
Equation 14
where:
Hgallowable is the mass of mercury emissions allowed for the compliance year
GEOGWh is the annual gross energy output of the EGU, in GWh, as determined in s. NR 446.18 (4) for the compliance year
BMC is the baseline mercury concentration determined in par. (f) 2. for the EGU in pounds per mmBtu
Hg CE is the applicable requirement for percent mercury control removal divided by 100
HIi is the amount of fuel, in mmBtu combusted each hour i, in the baseline determination year
h is the total number of hours fuel is combusted during the calendar year designated for measuring baseline emissions data under par. (c)
Loading...
Loading...
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date the chapter was last published.