NR 422.10NR 422.10 Furniture metal coating — part 1. NR 422.10(1)(1) Applicability. This section applies, subject to the provisions of s. NR 425.03, to the application areas, flashoff areas and ovens of furniture metal coating lines involved in prime and topcoat or single coating operations. This section does not apply to sources exempted under s. NR 422.03. NR 422.10(2)(2) Emission limitations. No owner or operator of a furniture metal coating line may cause, allow or permit the emission of any VOCs in excess of 0.36 kilograms per liter of coating (3.0 pounds per gallon), excluding water, delivered to each coating applicator from prime and topcoat or single coat operations. NR 422.10 HistoryHistory: Renum. from NR 154.13 (4) (h) and am. Register, September, 1986, No. 369, eff. 10-1-86; am. (2), Register, February, 1990, No. 410, eff. 3-1-90; CR 08-102: am. (title) Register July 2009 No. 643, eff. 8-1-09. NR 422.105NR 422.105 Furniture metal coating — part 2. NR 422.105(1)(1) Applicability. This section applies to facilities which are located in the county of Kenosha, Milwaukee, Ozaukee, Racine, Sheboygan, Washington, or Waukesha and have VOC emissions, before consideration of controls, equal to or exceeding 3 tons on a 12 consecutive month rolling basis from the application of coatings, including any related cleaning activities, to metal furniture. For purposes of this section, coatings include paints, sealants, caulks, inks, adhesives or maskants, but do not include metal protection oils, acids and bases. NR 422.105(2)(2) Exemptions. The following coating types are exempt from the emission limitations in sub. (3): NR 422.105(3)(3) Emission limitations. On and after May 1, 2010, no owner or operator may cause, allow or permit the emission of any VOCs in excess of limits listed in Table 2A. Notwithstanding s. NR 422.04 (4), an owner or operator using a control device to achieve compliance with this subsection as allowed under s. NR 422.04 (2) (c), shall achieve a minimum overall VOC control efficiency of 90%. NR 422.105(4)(4) Application equipment and methods. No owner or operator of a furniture metal coating line subject to sub. (3) may apply coatings unless one of the following types of high transfer efficiency application equipment is used in accordance with the manufacturer’s recommendations: NR 422.105(4)(f)(f) A coating application method demonstrated to the department to be capable of achieving a transfer efficiency equivalent to or better than that achieved by low-pressure spray method, and for which written approval of the department has been obtained. NR 422.105(5)(5) Work practices. On and after November 1, 2009, the owner or operator of a furniture metal surface coating facility shall employ work practices to minimize VOC emissions from mixing operations, storage tanks and other containers, and handling operations for coatings, thinners, cleaning materials, and waste materials. Work practices shall include all of the following, at a minimum: NR 422.105(5)(a)(a) Store all VOC-containing coatings, thinners, coating related waste materials, cleaning materials, and shop towels used for cleaning in closed containers. NR 422.105(5)(b)(b) Close mixing and storage vessels used for VOC-containing coatings and other materials except when depositing or removing these materials. NR 422.105(5)(c)(c) Convey VOC-containing coatings, thinners, and cleaning materials in closed containers or pipes. NR 422.105(5)(d)(d) Minimize spills of VOC-containing coating, thinners, and cleaning materials. NR 422.105(5)(e)(e) Minimize emissions of VOC during cleaning of coating application, storage, mixing, and conveying equipment. NR 422.105 HistoryHistory: CR 08-102: cr. Register July 2009 No. 643, eff. 8-1-09; CR 11-005: am. (5) (b) Register January 2012 No. 673, eff. 2-1-12. NR 422.11NR 422.11 Surface coating of large appliances — part 1. NR 422.11(1)(1) Applicability. This section applies, subject to the provisions of s. NR 425.03, to application areas, flashoff areas and ovens of large appliance coating lines involved in single, prime or topcoat coating operations. This section does not apply to: NR 422.11(1)(b)(b) The use of quick-drying lacquers for repair of scratches and nicks that occur during assembly, provided that the volume of coating does not exceed 0.95 liters (1 quart) in any one 8-hour period for any appliance coating line. NR 422.11(2)(2) Emission limitations. No owner or operator of a large appliance coating line may cause, allow or permit the emission of any VOCs in excess of 0.34 kilograms per liter of coating (2.8 pounds per gallon), excluding water, delivered to each coating applicator from single, prime or topcoat coating operations. NR 422.11 HistoryHistory: Renum. from NR 154.13 (4) (i) and am. Register, September, 1986, No. 369, eff. 10-1-86; am. (2), Register, February, 1990, No. 410, eff. 3-1-90; CR 08-102: am. (title) Register July 2009 No. 643, eff. 8-1-09. NR 422.115NR 422.115 Surface coating of large appliance — part 2. NR 422.115(1)(1) Applicability. This section applies to facilities which are located in the county of Kenosha, Milwaukee, Ozaukee, Racine, Sheboygan, Washington or Waukesha and have VOC emissions, before consideration of controls, equal to or exceeding 3 tons on a 12 consecutive month rolling basis from large appliance surface coating, including any related cleaning activities. For purposes of this section, coatings include paints, sealants, caulks, inks, adhesives, and maskants, but do not include metal protection oils, acids and bases. NR 422.115(2)(2) Exemptions. The following coating types are exempt from the emission limitations in sub. (3): NR 422.115(3)(3) Emission limitations. On and after May 1, 2010, no owner or operator may cause, allow or permit the emission of any VOCs in excess of limits listed in Table 2B. Notwithstanding s. NR 422.04 (4), an owner or operator using a control device to achieve compliance with this subsection as allowed under s. NR 422.04 (2) (c), shall achieve a minimum overall VOC control efficiency of 90%. NR 422.115(4)(4) Application equipment and methods. No owner or operator of a large appliance surface coating line subject to sub. (3) may apply coatings unless one of the following types of high transfer efficiency application equipment is used in accordance with the manufacturer’s recommendations: NR 422.115(4)(f)(f) Any other coating application method demonstrated to the department to be capable of achieving a transfer efficiency equivalent to or better than that achieved by low-pressure spray method, and for which written approval of the department has been obtained. NR 422.115(5)(5) Work practices. On and after November 1, 2009, the owner or operator of a large appliance surface coating facility shall employ work practices to minimize VOC emissions from mixing operations, storage tanks and other containers, and handling operations for coatings, thinners, cleaning materials, and waste materials. Work practices shall include all of the following, at a minimum: NR 422.115(5)(a)(a) Store all VOC-containing coatings, thinners, coating related waste materials, cleaning materials, and shop towels used for cleaning in closed containers. NR 422.115(5)(b)(b) Close mixing and storage vessels used for VOC-containing coatings and other materials except when depositing or removing these materials. NR 422.115(5)(c)(c) Convey VOC-containing coatings, thinners, and cleaning materials in closed containers or pipes. NR 422.115(5)(d)(d) Minimize spills of VOC-containing coating, thinners, and cleaning materials. NR 422.115(5)(e)(e) Minimize emissions of VOC during cleaning of coating application, storage, mixing, and conveying equipment. NR 422.115 HistoryHistory: CR 08-102: cr. Register July 2009 No. 643, eff. 8-1-09; CR 11-005: am. (5) (b) Register January 2012 No. 673, eff. 2-1-12. NR 422.12(1)(1) Applicability. This section applies, subject to the provisions of s. NR 425.03, to the ovens of magnet wire coating operations. This section does not apply to sources exempted under s. NR 422.03. NR 422.12(2)(2) Emission limitation. No owner or operator of a magnet wire coating oven may cause, allow or permit the emission of any VOCs in excess of 0.20 kilograms per liter of coating (1.7 pounds per gallon), excluding water, delivered to each coating applicator from magnet wire coating operations. NR 422.12 HistoryHistory: Renum. from NR 154.13 (4) (j) and am. Register, September, 1986, No. 369, eff. 10-1-86; am. (2), Register, February, 1990, No. 410, eff. 3-1-90. NR 422.125(1)(a)(a) This section applies to the wood furniture finishing operations of any wood furniture manufacturing facility which is located in the county of Kenosha, Milwaukee, Ozaukee, Racine, Sheboygan, Washington, or Waukesha, and whose maximum theoretical emissions of VOCs from all wood furniture finishing operations at the facility, including any related cleaning activities, is greater than or equal to 25 tons per year. NR 422.125(1)(b)(b) This section applies, except for sub. (4m), to any wood furniture manufacturing facility which is located in the county of Kewaunee or Manitowoc, and whose maximum theoretical emissions of VOCs from all wood furniture finishing operations at the facility is greater than or equal to 25 tons per year. NR 422.125(2)(2) Emission limitations. After September 1, 1996, no owner or operator of a wood furniture finishing operation may cause, allow or permit the emission of any VOCs in excess of the following limitations: NR 422.125(2)(a)1.1. 0.8 kilograms per kilogram of solids (0.8 pounds per pound), as applied, for topcoats only. NR 422.125 NoteNote: There is no restriction on the VOC content of the sealers used by those electing to comply under subd. 1.
NR 422.125(2)(a)2.2. 1.9 kilograms per kilogram of solids (1.9 pounds per pound), as applied, for sealers and 1.8 kilograms per kilogram of solids (1.8 pounds per pound), as applied, for topcoats. NR 422.125(2)(b)(b) Acid-cured alkyd amino coatings. When the owner or operator is using acid-cured alkyd amino vinyl sealers or acid-cured alkyd amino conversion varnish topcoats, any of the following: NR 422.125(2)(b)1.1. Where the sealer is an acid-cured alkyd amino vinyl sealer and the topcoat is an acid-cured alkyd amino conversion varnish topcoat, 2.3 kilograms per kilogram of solids (2.3 pounds per pound), as applied, for sealers and 2.0 kilograms per kilogram of solids (2.0 pounds per pound of solids), as applied, for topcoats. NR 422.125(2)(b)2.2. Where the sealer is not an acid-cured alkyd amino vinyl sealer and the topcoat is an acid-cured alkyd amino conversion varnish topcoat, 1.9 kilograms per kilogram of solids (1.9 pounds per pound), as applied, for sealers and 2.0 kilograms per kilogram of solids (2.0 pounds per pound), as applied, for topcoats. NR 422.125(2)(b)3.3. Where the sealer is an acid-cured alkyd amino vinyl sealer and the topcoat is not an acid-cured alkyd amino conversion varnish topcoat, 2.3 kilograms per kilogram of solids (2.3 pounds per pound), as applied, for sealers and 1.8 kilograms per kilogram of solids (1.8 pounds per pound), as applied, for topcoats. NR 422.125(2)(c)(c) Strippable spray booth coatings. 0.8 kilograms per kilogram of solids (0.8 pounds per pound) for strippable spray booth coatings, as applied. NR 422.125(3)(a)(a) Emission averaging. In addition to using provisions of s. NR 422.04 or 425.05 to demonstrate compliance, an owner or operator may demonstrate compliance with the emission limitations in sub. (2) (a) and (b) by showing that total daily actual emissions calculated using Equation 2 are less than or equal to total daily allowable emissions calculated using Equation 1. where:
EALL is the total daily allowable VOC emissions from all coatings involved in the average in kilograms (pounds)
i is a subscript denoting an individual coating
n is the number of different wood furniture coatings in an individual coating category applied during the actual production day and which are involved in the average
ATCi is the lowest of the applicable emission limitation under sub. (2) (a) or (b), or other limitation imposed by permit, order or approval, or the actual emission rate, as of the date of the notification required under sub. (5), in kilograms VOC per kilogram solids (pounds VOC per pound solids), for topcoat i as delivered to the applicator
STCi is the total amount of solids in topcoat i, in kilograms (pounds), delivered to the applicator during the actual production day
ASEi is the lowest of the applicable emission limitation under sub. (2) (a) or (b), or other limitation imposed by permit, order or approval, or the actual emission rate, as of the date of the notification required under sub. (5), in kilograms VOC per kilogram solids (pounds VOC per pound solids), for sealer i as delivered to the applicator
SSEi is the total amount of solids in sealer i, in kilograms (pounds), delivered to the applicator during the actual production day