NR 407.09(1)(b)4.4. The term specified by the department under subd. 3. for a non-part 70 source shall be at least 5 years from the date of the last issued initial or renewed operation permit. When establishing an expiration date, the department shall provide adequate time for the permit holder to prepare and submit a renewal application consistent with the timelines in s. NR 407.04 (2). NR 407.09(1)(c)(c) Monitoring, related recordkeeping and reporting requirements, as follows: NR 407.09(1)(c)1.a.a. All emissions monitoring, analysis procedures and test methods required under the applicable requirements. NR 407.09(1)(c)1.b.b. Where the applicable requirement does not require periodic testing or instrumental or noninstrumental monitoring, periodic monitoring or testing sufficient to yield reliable data from the relevant time period that are representative of the stationary source’s compliance with the permit. Monitoring or testing requirements shall assure use of terms, test methods, units, averaging periods, and other statistical conventions consistent with the applicable requirement. Monitoring may consist of recordkeeping sufficient to meet the requirements of this subd. 1. b. Permits for non-part 70 sources shall contain the requirements in this subd. 1. b. only for those air contaminants emitted from an emissions unit, operation, or activity where the actual emissions exceed the levels in Table 3 in s. NR 407.05. Actual emissions used for this determination shall be those reported under ch. NR 438 for the most recent year prior to when the permit or renewal is issued. NR 407.09(1)(c)1.c.c. As necessary, requirements concerning the use, maintenance, calibration and, where appropriate, installation of monitoring equipment or methods. NR 407.09(1)(c)3.3. Reporting requirements consistent with all applicable requirements and including the following: NR 407.09(1)(d)(d) A severability clause that states that, in the event of a successful challenge to any portion of the permit, all other portions of the permit remain valid and effective. NR 407.09(1)(f)1.1. The permittee has the duty to comply with all conditions of the permit. Any noncompliance with the operation permit constitutes a violation of the statutes and is grounds for enforcement action; for permit suspension, revocation or revision; or for denial of a permit renewal application. NR 407.09(1)(f)2.2. It is not a defense for a permittee in an enforcement action that it would have been necessary to halt or reduce the permitted activity in order to maintain compliance with the permit. NR 407.09(1)(f)3.3. The permit may be revised, revoked or suspended for cause under this chapter. The filing of a request by the permittee for a permit revision or for revocation, or the filing of notification of planned changes under s. NR 407.025 or of anticipated noncompliance, does not stay any permit condition. NR 407.09(1)(f)4.4. The permit does not convey any property rights of any sort, or any exclusive privilege. NR 407.09(1)(f)5.5. The permittee shall furnish to the department, within a reasonable time specified by the department, any information that the department may request in writing to determine whether cause exists to revise, revoke or suspend the permit or to determine compliance with the permit. Upon request, the permittee shall also furnish to the department copies of records required to be kept pursuant to the permit. NR 407.09(2)(2) Special permit requirements. Each permit issued under this chapter shall include the following elements if they are applicable to a stationary source: NR 407.09(2)(a)(a) For affected sources, conditions prohibiting emissions exceeding any allowances that the source lawfully holds under the acid rain program, including allowances allocated directly to the source through the acid rain program, and allowances obtained through the emissions trading provisions of the acid rain program, subject to the following qualifications: NR 407.09(2)(a)1.1. No permit revision may be required for increases in emissions that are authorized by allowances acquired pursuant to the acid rain program, provided that the increases do not require a permit revision under any other applicable requirement. NR 407.09(2)(a)2.2. No limit may be placed on the number of allowances that may be held by the stationary source. NR 407.09(2)(a)3.3. A stationary source may not use allowances as a defense to noncompliance with any applicable requirement other than the requirements of the acid rain program. NR 407.09(2)(a)4.4. Any acid rain allowance shall be accounted for according to the procedures established in the acid rain program. NR 407.09(2)(b)(b) For those stationary sources which identify reasonably anticipated alternate operating scenarios in their applications, terms and conditions covering reasonably anticipated alternate operating scenarios that are approved by the department. The terms and conditions shall require all of the following: NR 407.09(2)(b)1.1. The permittee, contemporaneously with making a change from one operating scenario to another, shall record in a log at the permitted facility a record of the scenario under which it is operating. NR 407.09(2)(b)2.2. The source shall comply with all applicable requirements for each alternate operating scenario. NR 407.09(2)(c)(c) For sources for which an internal offset has been approved by the department under s. NR 425.05, terms and conditions, if the permit applicant requests them, for the trading of emissions increases and decreases in the permitted facility, to the extent that the applicable requirements and internal offset approval allow for such trading without a case-by-case approval of each emissions trade. NR 407.09(2)(d)(d) For stationary sources that have previously been issued an air pollution control permit, provisions consistent with any condition in that permit if the provisions are still applicable to that stationary source. Conditions which may be considered still applicable include, but are not limited to, the following: NR 407.09(2)(d)2.2. Any conditions that a permittee requested in order to avoid being considered a major source or major modification under ch. NR 405 or 408 or to avoid any other requirement that would otherwise be applicable to the source. NR 407.09(2)(d)3.3. Any source-specific emission limits contained in a permit under any applicable requirement. NR 407.09(3)(a)(a) Except as provided in par. (b), all terms and conditions in an operation permit for a part 70 source, including any provisions designed to limit a stationary source’s potential to emit, are enforceable by the administrator under section 113 (a) of the Act (42 USC 7413 (a)) and citizens under section 304 of the Act (42 USC 7604). NR 407.09(3)(b)(b) Notwithstanding par. (a), the department shall specifically designate as not federally enforceable under the Act any terms and conditions included in the permit that are not required under the Act, under any of the Act’s applicable requirements or under the state implementation plan. NR 407.09(4)(a)(a) All operation permits shall contain the following provisions with respect to compliance: NR 407.09(4)(a)1.1. Compliance testing, monitoring, reporting and recordkeeping requirements sufficient to assure compliance with the terms and conditions of the permit. Any document required under an operation permit and submitted to the department, including reports, shall contain a certification by a responsible official that meets the requirements of s. NR 407.05 (4) (j). NR 407.09(4)(a)3.3. Requirements for certifying compliance with terms and conditions contained in the permit, including emission limitations, standards and work practices. Permits shall include each of the following: NR 407.09(4)(a)3.a.a. The required frequency of submission of compliance certifications, which shall be not less than annually or more frequently if specified in the applicable requirement or by the department. NR 407.09(4)(a)3.b.b. Means for assessing or monitoring the compliance of the source with its emissions limitations, standards and work practices, except that for non-part 70 sources, the means need only be included to the extent needed to comply with sub. (1) (c). NR 407.09(4)(a)3.d.d. A requirement that all compliance certifications for part 70 sources be submitted to the administrator as well as to the department. NR 407.09(4)(b)(b) All operation permits for stationary sources which are not proposed to be in compliance with all applicable requirements at the time of permit issuance shall contain a compliance schedule as described in s. 285.64 (1) (a) 1., Stats., and a schedule for submission of progress reports, consistent with the applicable compliance schedule. The progress reports shall be submitted at least semiannually, or more frequently if specified in the applicable requirement or by the department. Progress reports shall contain the following: NR 407.09(4)(b)1.1. The dates specified in the permit for achieving the activities, milestones or compliance required in the compliance schedule, and the dates when the activities, milestones or compliance were achieved. NR 407.09(4)(b)2.2. An explanation of why any dates in the compliance schedule were not or will not be met, and any preventive or corrective measures adopted. NR 407.09(5)(b)2.2. The liability of an owner or operator of a stationary source for any violation of applicable requirements prior to or at the time of permit issuance. NR 407.09 HistoryHistory: Cr. Register, December, 1993, No. 456, eff. 1-1-94; correction in (4) (a) 3. c. made under s. 13.93 (2m) (b) 7., Stats., Register, April, 1995, No. 472; am. (4) (a) 3. c., Register, December, 1995, No. 480, eff. 1-1-96; am. (2) (b), Register, December, 1996, No. 492, eff. 1-1-97; am. (1) (f) 1., (4) (a) 1. and (b) (intro.), Register, December, 1997, No. 504, eff. 1-1-98; CR 02-097: am. (1) (c) 1. b., Register June 2004 No. 582, eff. 7-1-04; CR 09-020: am. (1) (a) 2., (2) (d) 1., (3), (4) (a) 3. e., (5) (b) 1. and 4. Register January 2010 No. 649, eff. 2-1-10; CR 15-005: am. (1) (b) 1., cr. (1) (b) 3., 4., am. (1) (c) 1. b. Register November 2015 No. 719, eff. 12-1-15. NR 407.10NR 407.10 General operation permits. NR 407.10(1)(a)(a) The department may issue general permits for the operation of stationary sources in accordance with s. 285.60 (3), Stats. NR 407.10 NoteNote: No construction permit is required prior to commencing construction, reconstruction, replacement, relocation or modification of a stationary source if the source is covered under a general operation permit and the project meets the criteria in s. NR 407.10 (4) (a). NR 407.10(1)(b)(b) A general operation permit may be issued for a source category if the sources in the category meet all of the following criteria: NR 407.10 NoteNote: An example of “the same class of air contaminants” is volatile organic compounds.
NR 407.10(1)(b)3.3. Employ the same or similar capture and control systems, if applicable. NR 407.10(1)(b)4.4. Are subject to the same or similar emission limitations and other state and federal requirements that are applicable to the sources in the category. NR 407.10 NoteNote: An example of “similar emission limitations” is emission limitations for the same air contaminant but that differ based on the size of the source, its location, or its date of construction.
NR 407.10(1)(c)(c) When proposing to issue a general operation permit, the department shall prepare an air quality analysis and a preliminary determination on the approvability of the proposed general operation permit. The department shall use the applicable procedures in s. 285.62, Stats., to issue the general operation permit. The department may issue the general operation permit if the applicable criteria in ss. 285.63 and 285.64, Stats., are met. The procedural requirements in s. 285.62 (2) to (5), Stats., do not apply to the determination of whether an individual source is covered by a general operation permit for a source category. Coverage of a part 70 source under a general operation permit is not an appealable decision under s. 227.42, 227.52, 227.53 or 285.81, Stats. NR 407.10 NoteNote: The statutes cited above require that when issuing a general operation permit, the department distribute a notice of the availability of the proposed general operation permit and of the department’s analysis and preliminary determination, a notice of the opportunity for public comment and a notice of the opportunity to request a public hearing. There will be a 30-day public comment period and the department may hold a public hearing within 60 days after the deadline for requesting one.
NR 407.10(1)(d)(d) The general operation permit shall contain applicability criteria, emission limits, monitoring and recordkeeping requirements, reporting requirements, compliance demonstration methods and general conditions applicable to the stationary source category. The permit terms and conditions shall be those required to comply with the Act and those required to assure compliance with applicable provisions in ch. 285, Stats., and chs. NR 400 to 499. Notwithstanding the requirement in s. NR 424.03 (2) (c) to determine the latest available control techniques and operating practices demonstrating best current technology (LACT) for a specific process line, the department may include conditions in the general operation permit that represent LACT, if the requirements of s. NR 424.03 (2) (a) or (b) are determined to be technologically infeasible. NR 407.10 NoteNote: If an area is designated nonattainment for particulate matter, PM10, sulfur dioxide, nitrogen oxides, carbon monoxide or lead, the department may revise the general operation permit, or issue a different one, to include nonattainment area specific applicability criteria.
NR 407.10(1)(e)(e) The term of a general operation permit issued to a part 70 source category, or granted to an individual part 70 source, may not exceed 5 years. General operation permits issued to a non-part 70 source category, or granted to an individual non-part 70 source, shall only expire if an expiration date is requested by the source owner or operator or the department finds that expiring coverage would significantly improve the likelihood of continuing compliance with applicable requirements, compared to coverage that does not expire. NR 407.10(2)(2) Sources ineligible for coverage under a general operation permit. Notwithstanding the existence of a general operation permit for a stationary source category, an individual stationary source may not be covered by a general operation permit if any of the following criteria apply: NR 407.10(2)(a)(a) The emissions unit or units are an affected source under ch. NR 409, a municipal solid waste combustion source under s. NR 500.03 (86), or an infectious waste combustion source. NR 407.10(2)(b)(b) The emissions unit or units cause or exacerbate, or may cause or exacerbate, a violation of any ambient air quality standard or ambient air increment, as determined by the department through an air quality assessment conducted in accordance with s. NR 407.15 (8). NR 407.10(3)(3) Procedure for determining coverage under a general operation permit for an individual source. NR 407.10(3)(a)(a) An owner or operator of a stationary source who applies for coverage under a general operation permit shall submit an application using department approved general permit application forms. NR 407.10 NoteNote: Contact the regional offices or service centers of the department or the Permits and Stationary Source Modeling Section of the Bureau of Air Management, 608-266-7718, for information on how to obtain the department approved general permit application forms.
NR 407.10(3)(b)(b) An owner or operator of a stationary source who requests or requires emission limits, terms or conditions other than, or in addition to, those contained in the general operation permit shall apply for a different type of permit. NR 407.10(3)(c)(c) Within 15 days after the receipt of an application for coverage under a general operation permit, the department shall provide one of the following to an applicant: NR 407.10(3)(c)1.1. Written notice of the department’s determination that the source is covered under the general operation permit. NR 407.10(3)(c)2.2. A written description of any information that is missing from the application for coverage under the general operation permit. NR 407.10(3)(c)3.3. Written notice of the department’s determination that the source does not qualify for coverage under the general operation permit, specifically describing the reasons for that determination. NR 407.10(3)(d)(d) The department shall grant coverage under the general operation permit if the owner or operator of the source applies for coverage and meets the eligibility requirements of the general operation permit, unless the source is ineligible for coverage under sub. (2). NR 407.10(4)(4) Construction and modification under a general operation permit. NR 407.10(4)(a)(a) Notwithstanding the provisions in s. NR 406.04 (1) and (2), no construction permit is required prior to commencing construction, reconstruction, replacement, relocation or modification of a stationary source if the source is covered under a general operation permit and all of the following criteria are met: NR 407.10(4)(a)1.1. The construction, reconstruction, replacement, relocation or modification will not result in the source violating any term or condition of the general operation permit. NR 407.10(4)(a)2.2. The construction, reconstruction, replacement, relocation or modification does not require a permit under ch. NR 405 or 408. NR 407.10 NoteNote: Some general operation permits issued prior to September 1, 2005 may have required a construction permit, even if the change at the source would not violate any term or condition of the permit. Those sources are now exempt from the requirement to obtain a construction permit if the change at the source will not violate any term or condition of the general operation permit.