NR 270.102(4)(b)(b) In the event that the annual precipitation falling on the treatment facility and the drainage area contributing surface runoff to the treatment facility exceeds the annual evaporation, a volume of water equivalent to the difference between annual precipitation falling on the treatment facility and the drainage area contributing surface runoff to the treatment facility and annual evaporation may be discharged subject to the limitations set forth in sub. (1). NR 270.102 NoteNote: The concentration of pollutants discharged in mine drainage from mines of discharged from mine and mill complexes beneficiating gold ores or silver ores by gravity separation methods including mining of placer deposits, dredge mining and hydraulic mining operations will be proposed and promulgated at a late date.
NR 270.102(6)(6) The concentration of pollutants discharged in mine drainage from mines producing 5000 metric tons (5512 short tons) or more of molybdenum bearing ores per year may not exceed: NR 270.102(7)(7) The concentration of pollutants discharged in mine drainage from mines producing less than 5000 metric tons (5512 short tons) or discharged from mills processing less than 5000 metric tons (5512 short tons) of molybdenum ores per year by methods other than ore leaching may not exceed: NR 270.102(8)(8) The concentration of pollutants discharged from mills processing 5,000 metric tons (5,512 short tons) or more of molybdenum ores per year by purely physical methods including ore crushing, washing, jigging, and heavy media separation may not exceed: NR 270.102(9)(9) The concentration of pollutants discharged from mills processing 5000 metric tons (5512 short tons) or more of molybdenum ores per year by froth flotation methods may not exceed: NR 270.102 HistoryHistory: Cr. Register, October, 1986, No. 370, eff. 11-1-86. NR 270.103NR 270.103 Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT). Except as provided in ss. NR 270.0015, 270.002 and 270.003 and 40 CFR 125.30-125.32, any existing point source subject to this subcategory shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT): NR 270.103(1)(1) The concentration of pollutants discharged in mine drainage from mines that produce copper, lead, zinc, gold, silver, or molybdenum bearing ores or any combination of these ores from open-pit or underground operations other than placer deposits may not exceed: NR 270.103(2)(2) The concentration of pollutants discharged from mills that use the froth flotation process alone, or in conjunction with other processes, for the beneficiation of copper, lead, zinc, gold, silver, or molybdenum ores or any combination of these ores may not exceed: NR 270.103(3)(a)(a) Except as provided in this subsection, there may not be discharge of process wastewater to navigable waters from mine areas and mill processes and areas that use dump, heap, in-situ leach or vat-leach processes to extract copper from ores or ore waste materials. NR 270.103(3)(b)(b) In the event that the annual precipitation falling on the treatment facility and the drainage area contributing surface runoff to the treatment facility exceeds the annual evaporation, a volume of water equal to the difference between annual precipitation falling on the treatment facility and the drainage area contributing surface runoff to the treatment facility and annual evaporation may be discharged subject to the limitations set forth in sub. (1). NR 270.103(4)(a)(a) Except as provided in this subsection, there may not be discharge of process wastewater to navigable waters from mills that use the cyanidation process to extract gold or silver. NR 270.103(4)(b)(b) In the event that the annual precipitation falling on the treatment facility and the drainage area contributing surface runoff to the treatment facility exceeds the annual evaporation, a volume of water equal to the difference between annual precipitation falling on the treatment facility and the drainage area contributing surface runoff to the treatment facility and annual evaporation may be discharged subject to the limitations set forth in sub. (1). NR 270.103 NoteNote: The concentration of pollutants discharged in mine drainage or discharged from mines and mills beneficiating gold or silver ores by gravity separation methods including mining of placer deposits, dredge mining and hydraulic mining operations will be proposed and promulgated at a later date.
NR 270.103 HistoryHistory: Cr. Register, October, 1986, No. 30, eff. 11-1-86. NR 270.104NR 270.104 New source performance standards (NSPS). Except as provided in ss. NR 270.0015, 270.002 and 270.003 and 40 CFR 125.30-125.32, any new source subject to this subcategory shall achieve the following NSPS representing the degree of effluent reduction attainable by the application of the best available demonstrated technology (BADT): NR 270.104(1)(1) The concentration of pollutants discharged in mine drainage from mines that produce copper, lead, zinc, gold, silver, or molybdenum bearing ores or any combination of these ores from open-pit or underground operations other than placer deposits may not exceed: NR 270.104(2)(a)(a) Except as provided in this subsection, there may not be discharge of process wastewater to navigable waters from mills that use the froth-flotation process alone, or in conjunction with other processes, for the beneficiation of copper, lead, zinc, gold, silver, or molybdenum ores or any combination of these ores. NR 270.104(2)(b)1.1. In the event that the annual precipitation falling on the treatment facility and the drainage area contributing surface runoff to the treatment facility exceeds the annual evaporation, a volume of water equal to the difference between annual precipitation falling on the treatment facility and the drainage area contributing surface runoff to the treatment facility and annual evaporation may be discharged subject to the limitations set forth in sub. (1). NR 270.104(2)(b)2.2. In the event there is a build up of contaminants in the recycle water which significantly interferes with the ore recovery process and this interference cannot be eliminated through appropriate treatment of the recycle water, the permitting authority may allow a discharge of process wastewater in an amount necessary to correct the interference problem after installation of appropriate treatment. This discharge shall be subject to the limitations of sub. (1). The facility shall have the burden of demonstrating to the department that that discharge is necessary to eliminate interference in the ore recovery process and that the interference could not be eliminated through appropriate treatment of the recycle water. NR 270.104(3)(a)(a) Except as provided in this subsection, there may not be discharge of process wastewater to navigable waters from mine areas and mill processes and areas that use dump, heap, in-situ leach or vat-leach processes to extract copper from ores or ore waste materials. NR 270.104(3)(b)(b) In the event that the annual precipitation falling on the treatment facility and the drainage area contributing surface runoff to the treatment facility exceeds the annual evaporation, a volume of water equal to the difference between annual precipitation falling on the treatment facility and the drainage area contributing surface runoff to the treatment facility and annual evaporation may be discharged subject to the limitations set forth in sub. (1). NR 270.104(4)(a)(a) Except as provided in this subsection, there may not be discharge of process wastewater to navigable waters from mills that use the cyanidation process to extract gold or silver. NR 270.104(4)(b)(b) In the event that the annual precipitation falling on the treatment facility and the drainage area contributing surface runoff to the treatment facility exceeds the annual evaporation, a volume of water equal to the difference between annual precipitation falling on the treatment facility and the drainage area contributing surface runoff to the treatment facility and annual evaporation may be discharged subject to the limitations set forth in sub. (1). NR 270.104 NoteNote: The concentration of pollutants discharged in mine drainage or discharged from mines and mills beneficiating gold or silver ores by gravity separation methods including mining of placer deposits, dredge mining and hydraulic mining operations will be proposed and promulgated at a later date.
NR 270.104 HistoryHistory: Cr. Register, October, 1986, No. 370, eff. 11-1-86. NR 270.11NR 270.11 Applicability; description of the platinum ore subcategory. The provisions of this subcategory are applicable to discharges from: NR 270.11 HistoryHistory: Cr. Register, October, 1986, No. 370, eff. 11-1-86. NR 270.113NR 270.113 Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT). Except as provided in ss. NR 270.0015, 270.002 and 270.003 and 40 CFR 125.30-125.32, any existing point source subject to this subcategory shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT): NR 270.113(1)(1) The concentration of pollutants discharged in mine drainage from mines that produce platinum bearing ores from open-pit or underground operations other than placer deposits may not exceed: NR 270.113(2)(2) The concentration of pollutants discharged from mills that use the froth-flotation process alone, or in conjunction with other processes, for the beneficiation of platinum ores may not exceed: NR 270.113 HistoryHistory: Cr. Register, October, 1986, No. 370, eff. 11-1-86. NR 270.12NR 270.12 Cross-references. The federal citations in this chapter correspond to provisions of the Wisconsin Administrative Code and Wisconsin Statutes. The federal citations may be cross-referenced in the following table: NR 270.12 HistoryHistory: Cr. Register, October, 1986, No. 370, eff. 11-1-86; correction made under s. 13.93 (2m) (b) 7., Stats., Register, November, 1997.
/exec_review/admin_code/nr/200/270
true
administrativecode
/exec_review/admin_code/nr/200/270/104/4/a
Department of Natural Resources (NR)
Chs. NR 200-299; Environmental Protection – Wisconsin Pollutant Discharge Elimination System
administrativecode/NR 270.104(4)(a)
administrativecode/NR 270.104(4)(a)
section
true