NR 256.40 HistoryHistory: Cr. Register, June, 1989, No. 402, eff. 7-1-89, NR 256.42NR 256.42 Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available. Except as provided in 40 CFR 125.30 to 125.32, any existing point source subject to this subchapter, including noncontinuous direct dischargers, shall achieve the following BPT effluent limitations: NR 256.42 Note(1) These concentrations shall be multiplied by the ratio of (5.35/x) where x is the actual normalized process wastewater discharge flow (in gallons per 1,000 pounds of metal poured) for a specific plant.
(2) kg/1,000 kkg (pounds per million pounds) of metal poured
(3) Within the range of 7.0 to 10.0 at all times
NR 256.42 Note(1) These concentrations shall be multiplied by the ratio of (1.04/x) where x is the actual normalized process wastewater discharge flow (in gallons per 1,000 pounds of metal poured) for a specific plant.
(2) kg/1,000 kkg (pounds per million pounds) of metal poured
(3) Within the range of 7.0 to 10.0 at all times
NR 256.42 Note(1) These concentrations shall be multiplied by the ratio of (0.243/x) where x is the actual normalized process wastewater discharge flow (in gallons per 1,000 SCF of air scrubbed) for a specific plant.
(2) kg/62.3 million Sm3 (pounds per billion SCF) of air scrubbed
(3) Within the range of 7.0 to 10.0 at all times
NR 256.42 Note(1) These concentrations shall be multiplied by the ratio of (47.3/x) where x is the actual normalized process wastewater discharge flow (in gallons per 1,000 pounds of metal poured) for a specific plant.
(2) kg/1,000 kkg (pounds per million pounds) of metal poured
(3) Within the range of 7.0 to 10.0 at all times
NR 256.42 HistoryHistory: Cr. Register, June, 1989, No. 402, eff. 7-1-89. NR 256.43NR 256.43 Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable. Except as provided in 40 CFR 125.30 to 125.32, any existing point source subject to this subchapter, including noncontinuous direct dischargers, shall achieve the following BAT effluent limitations: NR 256.43 Note(1) These concentrations shall be multiplied by the ratio of (5.34/x) where x is the actual normalized process wastewater discharge flow (in gallons per 1,000 pounds of metal poured) for a specific plant.
(2) kg/1,000 kkg (pounds per million pounds) of metal poured
NR 256.43 Note(1) These concentrations shall be multiplied by the ratio of (1.04/x) where x is the actual normalized process wastewater discharge flow (in gallons per 1,000 pounds of metal poured) for a specific plant.
(2) kg/1,000 kkg (pounds per million pounds) of metal poured.
NR 256.43 Note(1) These concentrations shall be multiplied by the ratio of (0.243/x) where x is the actual normalized process wastewater discharge flow (in gallons per 1,000 SCF of air scrubbed) for a specific plant.
(2) kg/62.3 million Sm3 (pounds per billion SCF) of air scrubbed.
NR 256.43 Note(1) These concentrations shall be multiplied by the ratio of (47.3/x) where x is the actual normalized process wastewater discharge flow (in gallons per 1,000 pounds of metal poured) for a specific plant.
(2) kg/1,000 kkg (pounds per million pounds) of metal poured.
NR 256.43 HistoryHistory: Cr. Register, June, 1989, No. 402, eff. 7-1-89. NR 256.44NR 256.44 New source performance standards. Any new source subject to this subchapter, including noncontinuous direct dischargers, shall achieve the following standards: NR 256.44 Note(1) These concentrations shall be multiplied by the ratio of (5.34/x) where x is the actual normalized process wastewater discharge flow (in gallons per 1,000 pounds of metal poured) for a specific plant.
(2) kg/1,000 kkg (pounds per million pounds) of metal poured
(3) Within the range of 7.0 to 10.0 at all times
NR 256.44 Note(1) These concentrations shall be multiplied by the ratio of (1.04/x) where x is the actual normalized process wastewater discharge flow (in gallons per 1,000 pounds of metal poured) for a specific plant.
(2) kg/1,000 kkg (pounds per million pounds) of metal poured
(3) Within the range of 7.0 to 10.0 at all times
NR 256.44 Note(1) These concentrations shall be multiplied by the ratio of (0.243/x) where x is the actual normalized process wastewater discharge flow (in gallons per 1,000 SCF of air scrubbed) for a specific plant.
(2) kg/62.3 million Sm3 (pounds per billion SCF) of air scrubbed
(3) Within the range of 7.0 to 10.0 at all times
NR 256.44 Note(1) These concentrations shall be multiplied by the ratio of (47.3/x) where x is the actual normalized process wastewater discharge flow (in gallons per 1,000 pounds of metal poured) for a specific plant.
(2) kg/1,000 kkg (pounds per million pounds) of metal poured
(3) Within the range of 7.0 to 10.0 at all times
NR 256.44 HistoryHistory: Cr. Register, June, 1989, No. 402, eff. 7-1-89. NR 256.45NR 256.45 Pretreatment standards for existing sources. Except as provided in ss. NR 211.13 and 211.14 any existing source subject to this subchapter which introduces pollutants into a publicly owned treatment works shall comply with ch. NR 211 and achieve the following pretreatment for existing sources: NR 256.45 Note(2) TTO is comprised of the following toxic organic pollutants:
2,4,6-trichlorophenol
para-chloro meta-cresol
2,4-dichlorophenol
2,4-dimethylphenol
fluoranthene
methylene chloride (dichloromethane)
phenol
bis(2-ethylhexyl) phthalate
di-n-butyl phthalate
diethyl phthalate
tetrachloroethylene
(2) Use as alternative to monitoring for TTO.
NR 256.45 Note(1) TTO is comprised of the following toxic organic pollutants:
acenaphthene
2,4,6-trichlorophenol
para-chloro meta-cresol
2-chlorophenol
2,4-dimethylphenol
methylene chloride (dichloromethane)
naphthalene
phenol
bis(2-ethylhexyl) phthalate
di-n-butyl phthalate
diethyl phthalate
tetrachloroethylene
toluene
trichloroethylene
NR 256.45 Note(2)Use as alternative to monitoring for TTO.
NR 256.45 Note(1) TTO is comprised of the following toxic organic pollutants:
2,4-dichlorophenol
2,4-dimethylphenol
fluoranthene
methylene chloride (dichloromethane)
naphthalene
phenol
bis(2-ethylhexyl) phthalate
di-n-butyl phthalate
tetrachloroethylene
toluene
trichloroethylene
NR 256.45 Note(2)Use as alternative to monitoring for TTO
NR 256.45 Note(1) TTO is comprised of the toxic organic pollutants listed in Table 83.
(2) Use as alternative to monitoring for TTO
NR 256.45 HistoryHistory: Cr. Register, June, 1989, No. 402, eff. 7-1-89. NR 256.46NR 256.46 Pretreatment standards for new sources. Except as provided in s. NR 211.13, any new source subject to this subchapter which introduces pollutants into publicly owned treatment works shall comply with ch. NR 211 and achieve the pretreatment standards contained in s. NR 256.45. NR 256.46 HistoryHistory: Cr. Register, June, 1989, No. 402, eff. 7-1-89. NR 256.46 NoteNote: The citations of the Wisconsin administrative code correspond to provisions of the code of federal regulations as cross-referenced in the following table: