NR 229.03(1)(b)4.4. The device shall be accompanied by the manufacturer’s manual providing instructions for use including the frequency for inspection and collecting container replacement such that the unit is replaced once it has reached the maximum filling level at which the device can perform to the specified efficiency. NR 229.03(1)(b)5.5. The device shall be inspected in accordance with the manufacturer’s operation manual to ensure proper operation and maintenance, including confirmation that amalgam process wastewater is flowing through the amalgam separating portion of the device. NR 229.03(1)(b)6.6. In the event that a device is not functioning properly, it shall be repaired consistent with manufacturer instructions or replaced with a unit that meets the requirements under subds. 1. to 3. as soon as possible, but no later than 10 business days after the malfunction is discovered by the dental discharger, or an agent or representative of the dental discharger. NR 229.03(1)(b)7.7. The amalgam retaining unit of the device shall be replaced as specified in the manufacturer’s operating manual, or when the collecting container has reached the maximum filling level, as specified by the manufacturer in the operating manual, at which time the amalgam separator can perform to the specified efficiency, whichever comes first. NR 229.03(1)(b)8.8. The demonstration of the device under subds. 1. to 3. shall be documented in the one-time compliance report required under s. NR 229.05. NR 229.03(2)(2) Implementation of all of the following best management practices: NR 229.03(2)(a)(a) Waste amalgam including dental amalgam from chair-side traps, screens, vacuum pump filters, dental tools, cuspidors, or collection devices, may not be discharged to a POTW. NR 229.03(2)(b)(b) Dental unit water lines, chair-side traps, and vacuum lines that discharge amalgam process wastewater to a POTW may not be cleaned with oxidizing or acidic cleaners, including bleach, chlorine, iodine, or peroxide that have a pH lower than 6 or greater than 8. NR 229.03 HistoryHistory: CR 21-063: cr. Register April 2022 No. 796, eff. 5-1-22. NR 229.04NR 229.04 Pretreatment standards for new sources. As of July 14, 2017, a new source subject to this chapter shall comply with the requirements under s. NR 229.03 and the reporting and recordkeeping requirements under s. NR 229.05. NR 229.04 HistoryHistory: CR 21-063: cr. Register April 2022 No. 796, eff. 5-1-22. NR 229.05NR 229.05 Reporting and recordkeeping requirements. NR 229.05(1)(1) Reporting requirements. A dental discharger subject to this chapter shall comply with all of the following reporting requirements in lieu of the otherwise applicable requirements under s. NR 211.15 (1), (3), (4), and (7): NR 229.05(1)(a)(a) One-time compliance report deadlines. For an existing source, a one-time compliance report shall be submitted to the control authority no later than October 12, 2020, or 90 days after a transfer of ownership. For a new source, a one-time compliance report shall be submitted to the control authority no later than 90 days following the introduction of wastewater into a POTW. NR 229.05(1)(b)(b) Signature and certification. The one-time compliance report shall be signed and certified by a responsible corporate officer, a general partner, or proprietor of the dental discharger if the dental discharger is structured as a partnership or sole proprietorship, or an authorized representative in accordance with the requirements under s. NR 211.15 (10) if structured as a corporation. NR 229.05(1)(c)1.1. The one-time compliance report for a dental discharger that does not place or remove dental amalgam as described under s. NR 229.01 (6) shall include all of the following: NR 229.05(1)(c)1.a.a. The facility name, physical address, mailing address, and contact information for the dental discharger. NR 229.05(1)(c)1.c.c. A certification statement that the dental discharger does not place dental amalgam and does not remove amalgam except in limited circumstances. NR 229.05(1)(c)2.2. The one-time compliance report for a dental discharger that is not exempted from the requirements of this chapter under s. NR 229.01 (6) shall include all of the following: NR 229.05(1)(c)2.a.a. The facility name, physical address, mailing address, and contact information for the dental discharger. NR 229.05(1)(c)2.c.c. A description of the operation at the dental facility, including the total number of chairs, the total number of chairs at which dental amalgam may be present in the resulting wastewater, and a description of any existing amalgam separator or equivalent device currently operated to include, at a minimum, the make, model, and year of installation. NR 229.05(1)(c)2.d.d. Certification that the amalgam separator or equivalent device is designed and will be operated and maintained to meet the requirements specified under s. NR 229.03. NR 229.05(1)(c)2.e.e. Certification that the dental discharger is implementing best management practices specified under s. NR 229.03 (2) and will continue to do so. NR 229.05(1)(c)2.f.f. The name of the third-party service provider that maintains the amalgam separator or equivalent device operated at the dental office, if applicable. Otherwise, a brief description of the practices employed by the dental discharger to ensure proper operation and maintenance as specified under s. NR 229.03. NR 229.05(1)(d)(d) Transfer of ownership notification. If a dental discharger transfers ownership of the facility, the new owner shall submit a new one-time compliance report to the control authority no later than 90 days after the transfer. NR 229.05(1)(e)(e) Retention period. As long as a dental discharger subject to this chapter is in operation, or until ownership is transferred, the dental discharger or an agent or representative of the dental discharger shall retain the one-time compliance report required under sub. (1) and make it available for inspection in either physical or electronic form. NR 229.05(2)(2) Recordkeeping requirements. A dental discharger or an agent or representative of the dental discharger shall maintain and make available for inspection in either physical or electronic form, for a minimum of 3 years, all of the following: NR 229.05(2)(a)(a) Documentation of the date, person conducting the inspection, and results of each inspection of the amalgam separator or equivalent device, and a summary of follow-up actions, if needed. NR 229.05(2)(b)(b) Documentation of amalgam retaining container or equivalent container replacement, including the date, as applicable. NR 229.05(2)(c)(c) Documentation of all dates that collected dental amalgam is picked up or shipped for proper disposal in accordance with s. NR 662.014 (1) (e) and (f), and the name of the permitted or licensed treatment, storage, or disposal facility receiving the amalgam retaining containers. NR 229.05(2)(d)(d) Documentation of any repair or replacement of an amalgam separator or equivalent device, including the date, person making the repair or replacement, and a description of the repair or replacement, including make and model. NR 229.05(2)(e)(e) The manufacturer’s operating manual for the current device. NR 229.05 HistoryHistory: CR 21-063: cr. Register April 2022 No. 796, eff. 5-1-22.
/exec_review/admin_code/nr/200/229
true
administrativecode
/exec_review/admin_code/nr/200/229/05/2
Department of Natural Resources (NR)
Chs. NR 200-299; Environmental Protection – Wisconsin Pollutant Discharge Elimination System
administrativecode/NR 229.05(2)
administrativecode/NR 229.05(2)
section
true