NR 106.56 Establishment of water quality-based effluent limitations for temperature in WPDES permits. NR 106.57 Effluent limitations for multiple thermal discharges. NR 106.58 Effluent limitations based on water quality models. NR 106.59 Effluent limitations for temperature for permits issued to publicly or privately owned domestic sewage treatment works. NR 106.60 Effluent limitations for temperature for discharges from new facilities. NR 106.61 General permit. NR 106.62 Compliance schedules. Subchapter VI — Alternative Effluent Limitations for Temperature
NR 106.72 Application for alternative effluent limitations for temperature. NR 106.73 Identification of representative, important species. NR 106.74 Determination of alternative effluent limitations for temperature. NR 106.75 Compliance schedules. NR 106.77 Application of the variance process in s. 283.15, Stats. Subchapter VII — Effluent Limitations for Chloride Discharges
NR 106.83 Regulation of chloride discharges. NR 106.84 Compliance with Wisconsin water quality antidegradation rules when reissuing a permit. NR 106.85 Determination of the necessity for water quality-based effluent limitations. NR 106.87 Establishment of effluent limitations. NR 106.88 Application of and compliance with chloride effluent limitations in a permit. NR 106.89 Alternative whole effluent toxicity monitoring and limitations for dischargers of chloride. NR 106.90 Source reduction. NR 106.91 Variances for POTWs which accept wastewater from public water systems treating water to meet primary safe drinking water act standards. NR 106.92 Authority of a publicly owned treatment works to regulate chloride discharges. NR 106.93 New discharges. NR 106.94 Relocation of an existing discharge. NR 106.95 Multiple discharges. NR 106.96 Analytical methods and laboratory requirements. Subchapter VIII — Permit Requirements for PFOS and PFOA Discharges
NR 106.98 Determination of the necessity for reducing PFOS and PFOA in discharges. NR 106.985 PFOS and PFOA minimization plans, permit implementation procedures schedule. NR 106.99 PFOS and PFOA minimization plans. NR 106.995 Sampling and laboratory analysis requirements. NR 106.996 New dischargers or new sources. NR 106.01NR 106.01 Purpose. One purpose of this chapter is to specify how the department will calculate water quality based effluent limitations under s. 283.13 (5), Stats., for toxic and organoleptic substances and whole effluent toxicity. The other purpose of this chapter is to specify how the department will decide if and how these limitations will be included in Wisconsin pollution discharge elimination system (WPDES) permits. Water quality based effluent limitations for toxic and organoleptic substances are needed to assure attainment and maintenance of surface water quality standards as established in accordance with s. 281.15 (1), Stats., and as set forth in chs. NR 102 to 105. NR 106.01 HistoryHistory: Cr. Register, February, 1989, No. 398, eff. 3-1-89; correction made under s. 13.93 (2m) (b) 7., Stats., Register October 2002 No. 562. NR 106.02NR 106.02 Applicability. The provisions of this chapter are applicable to point sources which discharge wastewater containing toxic or organoleptic substances to surface waters of the state. NR 106.02 HistoryHistory: Cr. Register, February, 1989, No. 398, eff. 3-1-89. NR 106.03NR 106.03 Definitions. The following definitions are applicable to terms used in this chapter. NR 106.03(1r)(1r) “Bioaccumulative chemical of concern” or “BCC” means any substance that has the potential to cause adverse effects which, upon entering the surface waters, accumulates in aquatic organisms by a human health or wildlife bioaccumulation factor greater than 1000. NR 106.03(2)(2) “Biologically based design flow” means a receiving water design flow to protect fish and aquatic life for which both the duration of exposure is expressed in days and the allowable frequency of excursion is expressed in years. An example of a biologically based design flow is a 4-day 3-year design flow which corresponds to the lowest 4-day average flow that will limit excursions from any water quality criteria or secondary values to no more than once in 3 years. NR 106.03(2m)(2m) “Deficiency toxicity” means a condition that exists when adverse effects occur to aquatic organisms because concentrations of common ions are too low. NR 106.03 NoteNote: Changes in the concentration of ions in surrounding waters can cause organisms to expend too much energy trying to regulate the balance of water and dissolved materials in bodily fluids, and may result in death.
NR 106.03 NoteNote: Examples of common ions are sodium, calcium, magnesium, potassium, etc.
NR 106.03(3)(3) “Dynamic models” means computer simulation models which use real or derived time series data to predict a time series of observed or derived receiving water concentrations. Methods include continuous simulation, Monte Carlo simulations, or other similar statistical or deterministic techniques. NR 106.03(4)(4) “EC50” means the point estimate of the concentration of a toxic substance, wastewater effluent or other aqueous mixture which causes an adverse effect including mortality to 50% of the exposed organisms in a given time period, when compared to an appropriate control. NR 106.03(4g)(4g) “Great Lakes” means the open Wisconsin waters of Lake Superior, Lake Michigan, Green Bay, and Chequamegon Bay, as well as adjoining open waters that exhibit characteristics of Lake Superior, Lake Michigan, Green Bay, and Chequamegon Bay, or in other ways are determined by the department to be equivalent to these waters. NR 106.03(4r)(4r) “Great Lakes system” means all the surface waters within the drainage basin of the Great Lakes. NR 106.03(5)(5) “IC25” means the point estimate of the concentration of a toxic substance, wastewater effluent or other aqueous mixture that would cause a 25% reduction in a nonlethal biological measurement, such as reproduction or growth, of the exposed test organisms in a given time period. NR 106.03(5m)(5m) “IC50” means the point estimate of the concentration of a toxic substance, wastewater effluent or other aqueous mixture that would cause a 50% reduction in a nonlethal biological measurement, such as reproduction or growth, of the exposed test organisms in a given time period. NR 106.03(6)(6) “IWC” or “Instream waste concentration” means an estimate of the proportion of effluent to total volume of water (receiving water + effluent). The IWC is calculated according to the following equation: where:
Qe = effluent flow
f = fraction of the Qe withdrawn from the receiving water
Qs = receiving water flow (in most cases ¼ of a low flow value, such as the Q7,10, is used in order to allow a free zone of passage for aquatic organisms).
NR 106.03(7)(7) “LC50” means the point estimate of the concentration of a toxic substance, wastewater effluent or other aqueous mixture which is lethal to 50% of the exposed organisms in a given time period, when compared to an appropriate control. NR 106.03(8)(8) “Limit of detection” or “LOD” means the lowest concentration level that can be determined to be significantly different from a blank for that analytical test method and sample matrix. NR 106.03(9)(9) “Limit of quantitation” or “LOQ” means the concentration of an analyte at which one can state with a degree of confidence for that analytical test method and sample matrix that an analyte is present at a specific concentration on the sample tested. NR 106.03(11m)(11m) “Same waterbody” means hydrologically connected waters of the State with similar water quality characteristics in which a pollutant can travel between in a reasonable period of time without significantly changing chemically or physically. Hydrological connections can include surface and groundwater connections. NR 106.03(12)(12) “Toxicity test” means a test which determines the toxicity of a chemical substance, wastewater effluent or other aqueous mixture using living organisms. A toxicity test measures the degree of response of exposed test organisms to a chemical substance, wastewater effluent or other aqueous mixture. NR 106.03(13m)(13m) “TUc” or “toxic unit chronic” means a value that is equal to 100 divided by the IC25 or the IC50 except as provided in s. NR 106.08 (6) (d). NR 106.03(14)(14) “Whole effluent toxicity” or “WET” means the aggregate toxic effect of an effluent as measured directly by a toxicity test. NR 106.03 HistoryHistory: Cr. Register, February, 1989, No. 398, eff. 3-1-89; r. (7), renum. (1) to (6), (8) and (9) to be (4), (7) to (9), (12) and (14) and am. (2), (4), (7) and (12), cr. (1), (5), (6), (10), (11) and (13), Register, August, 1997, No. 500, eff. 9-1-97; CR 09-123: r. and recr. (6) Register July 2010 No. 655, eff. 8-1-10; CR 15-084: cr. (4g), (4r), (11m) Register August 2016 No. 728, eff. 9-1-16; CR 15-085: renum. (1) to (1r), cr. (1g), (2m), (5m), r. (10), (11), am. (13), cr. (13m), am. (14) Register August 2016 No. 728, eff. 9-1-16. NR 106.04(1)(1) The department shall establish water quality-based effluent limitations whenever categorical effluent limits required under s. 283.13, Stats., are less stringent than necessary to achieve applicable water quality standards specified in chs. NR 102 to 105. Water quality-based effluent limitations for a point source shall be specified in the permit for that point source. NR 106.04(2)(2) In no case may the water quality based effluent limitations be less stringent than applicable categorical effluent limitations. NR 106.04(3)(3) The department shall establish limitations for toxic and organoleptic substances if any of the conditions specified in s. NR 106.05 are met. Limitations shall be established according to the methods provided in s. NR 106.06 and included in WPDES permits according to the conditions provided in s. NR 106.07. The department shall establish limitations for whole effluent toxicity if any of the conditions specified in s. NR 106.08 are met. Whole effluent limitations shall be established and included in WPDES permits according to the methods provided in ss. NR 106.08 and 106.09. NR 106.04(3m)(3m) In lieu of imposing limitations at the point of discharge when imposition of limitations at the point source discharge location is impracticable or infeasible, the department may impose water quality-based effluent limitations on an internal waste stream before that waste stream mixes with other waste streams or cooling water streams. Monitoring requirements as specified in s. NR 106.07 (1) shall also be applied to the internal waste streams in these instances. NR 106.04(4)(4) Water quality based effluent limitations or monitoring requirements for toxic or organoleptic substances or whole effluent toxicity may be removed from a permit, subject to public notice and opportunity for hearing under ch. NR 203, if the limitation is determined to be unnecessary based on the procedures presented in this chapter or based on other information available to the department. NR 106.04(5)(5) For purposes of this chapter, a cost-effective pollutant minimization program is an activity which has as its goal the reduction of all potential sources of the pollutant for the purpose of maintaining the effluent at or below the water quality based effluent limitation. The pollutant minimization programs specified in ss. NR 106.05 (8), 106.06 (6) (d), 106.07 (6) (f) and 106.145 (7) shall include investigation of treatment technologies and efficiencies, process changes, wastewater reuse or other pollution prevention techniques that are appropriate for that facility, taking account of the permittee’s overall treatment strategies, facilities plans and operational circumstances. Past documented pollution prevention or treatment efforts may be used to satisfy all or part of a pollution minimization program requirement. The permittee shall submit to the department an annual status report on the progress of a pollutant minimization program. NR 106.04 HistoryHistory: Cr. Register, February, 1989, No. 398, eff. 3-1-89; am. (3), cr. (5), Register, August, 1997, No. 500, eff. 9-1-97; CR 02-019: am. (5) Register October 2002 No. 562, eff. 11-1-02; CR 15-085: am. (1) (intro.), cr. (3m) Register August 2016 No. 728, eff. 9-1-16. NR 106.05NR 106.05 Determination of the necessity for water quality based effluent limitations for toxic and organoleptic substances. NR 106.05(1)(a)(a) General. The department shall establish water quality based effluent limitations for point source dischargers whenever the discharges from those point sources contain(s) toxic or organoleptic substances at concentrations or loadings which do not, as determined by any method in this section, meet applicable water quality standards specified in chs. NR 102 to 105.