This is the preview version of the Wisconsin State Legislature site.
Please see http://docs.legis.wisconsin.gov for the production version.
ATCP 76.32(3)(a)5.5. The manual of instruction on filter operation.
ATCP 76.32(3)(a)6.6. Instructions for operation and maintenance of all equipment.
ATCP 76.32(3)(a)7.7. Instructions and other pertinent information on pool operation and maintenance.
ATCP 76.32(3)(a)8.8. The most recent United States centers for disease control and prevention recommendations for fecal accidents or another plan in response to fecal accidents that is consistent with the United States centers for disease control and prevention’s fecal accident response recommendations.
ATCP 76.32(3)(a)9.9. The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation. Pf
ATCP 76.32(3)(b)(b) File retention period. The following operational tests and reports shall be kept for a minimum of 2 years.
ATCP 76.32(3)(b)1.1. Anti-entrapment device or system test results as required by manufacturer and corrective actions taken, if needed. Pf
ATCP 76.32(3)(b)2.2. Any laboratory bacteriological report. Pf
ATCP 76.32(3)(b)3.3. Any fecal accident report made pursuant to s. ATCP 76.31.Pf
ATCP 76.32(3)(b)4.4. Any daily inspections and operational tests. Pf
ATCP 76.32(3)(b)5.5. Any other reports required by the department or its agent.
ATCP 76.32(3)(c)(c) Access. All of the documents under pars. (a) and (b), shall be accessible to the department or its agent upon request.
ATCP 76.32 HistoryHistory: CR 22-021: cr. Register June 2023 No. 810, eff. 9-24-23.
ATCP 76.33ATCP 76.33Facility maintenance, repair, and sanitation.
ATCP 76.33(1)(1)Pool area.
ATCP 76.33(1)(a)(a) Basin. The pool basin area shall meet all of the following and be:
ATCP 76.33(1)(a)1.1. Routinely brushed or vacuumed to keep the basin and surrounding appurtenances free of sediment, lint, hair, debris, algae, and slime growth and discoloration.
ATCP 76.33(1)(a)2.2. Maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition.
ATCP 76.33(1)(a)3.3. Maintained in a clean and sanitary condition.
ATCP 76.33(1)(a)4.4. Free of glass and shatterable plastic items, except for pool test kit contents while in use to test pool water according to manufacturer’s instructions and in drink preparation areas of a swim up bar. Pf
ATCP 76.33(1)(b)(b) Deck maintenance and cleaning.
ATCP 76.33(1)(b)1.1. Deck areas and appurtenances, including safety pads, shall meet all of the following and be:
ATCP 76.33(1)(b)1.a.a. Maintained in good repair.
ATCP 76.33(1)(b)1.b.b. Rinsed as needed to prevent microbial growth.
ATCP 76.33(1)(b)2.2. Disinfected at least weekly for indoor pool decks with disinfecting agents according to the manufacturer’s directions.
ATCP 76.33 NoteNote: It is recommended to avoid the use of an ammonia-based disinfectant as this can contribute to an increased level of chloramines in the pool water.
ATCP 76.33(1)(b)3.3. Cleaned as needed for outdoor pool decks.
ATCP 76.33(1)(b)4.4. Maintained so that depth markings along the edge of the pool are clearly visible and readable. Pf
ATCP 76.33(1)(b)5.5. Kept unobstructed except for easily portable furniture and equipment. Pf
ATCP 76.33(1)(c)(c) Walls, ceilings and floors. The walls, ceilings, and floors in the pool area shall be maintained in a clean and sanitary condition.
ATCP 76.33(1)(d)(d) Hosing. Hosing shall meet all of the following
ATCP 76.33(1)(d)1.1. Provided in adequate lengths to flush the entire pool deck.
ATCP 76.33(1)(d)2.2. Protected against backsiphonage by the proper installation of an approved backflow prevention device pursuant to s. SPS 390.16 (4) (b). P
ATCP 76.33(1)(e)(e) Equipment. Pool equipment, including equipment on the deck, shall be all of the following and properly:
ATCP 76.33(1)(e)2.2. Installed.
ATCP 76.33(1)(e)3.3. Maintained.
ATCP 76.33(1)(e)4.4. Repaired, as necessary.
ATCP 76.33(1)(f)(f) Spectator areas. Spectator areas shall be all of the following:
ATCP 76.33(1)(f)1.1. Maintained in a clean condition.
ATCP 76.33(1)(f)2.2. Set up and arranged so that tables, chairs, and other obstructions do not block the deck. Pf
ATCP 76.33(1)(g)(g) Drinking fountain. Drinking fountains shall be all of the following:
ATCP 76.33(1)(g)1.1. Be provided pursuant to s. SPS 390.19. P
ATCP 76.33(1)(g)2.2. Maintained in clean and sanitary condition.
ATCP 76.33(2)(2)Shower, toilet and dressing facilities.
ATCP 76.33(2)(a)(a) Walls and floors. The walls, partitions, and floors of showers, toilet rooms, and dressing areas shall be all of the following:
ATCP 76.33(2)(a)1.1. Maintained in good repair.
ATCP 76.33(2)(a)2.2. Cleaned and disinfected daily or more frequently, if necessary to provide clean and sanitary conditions.
ATCP 76.33 NoteNote: See s. SPS 390.19 for additional information.
ATCP 76.33(2)(b)(b) Showers. Showers shall be maintained in an operable condition.
ATCP 76.33 NoteNote: To minimize the risk of Legionella growth and other diseases associated with water, adequate provisions should be made to ensure that all water systems, including sink faucets, drinking fountains, and showers are safe. Any water aged over 3 weeks is potentially viable for growing Legionella colonies. It is strongly advised that each pool operator develop and implement a water management program as recommended by the United States centers for disease control and prevention Water Management Program Toolkit. The toolkit can be found at https://www.cdc.gov/legionella/wmp/toolkit/index.html.
ATCP 76.33(2)(c)(c) Toilet rooms and diaper changing areas. Toilet room fixtures and diaper changing stations shall be all of the following:
ATCP 76.33(2)(c)1.1. Kept clean.
ATCP 76.33(2)(c)2.2. Maintained in good repair.
ATCP 76.33(2)(d)(d) Lockers and furniture. Lockers and furniture shall be all of the following:
ATCP 76.33(2)(d)1.1. Cleaned as needed.
ATCP 76.33(2)(d)2.2. Maintained in good repair.
ATCP 76.33(2)(e)(e) Soap and soap dispensers. Soap and dispensers shall be all of the following:
ATCP 76.33(2)(e)1.1. Soap is continually provided at each hand washing sink and shower in permanently installed dispensing devices. Pf
ATCP 76.33(2)(e)2.2. The dispensers shall be maintained in operating condition.
ATCP 76.33(2)(f)(f) Hand drying devices. Individual towels in dispensers or hot air dryers shall be provided at hand washing sinks. Pf
ATCP 76.33(2)(g)(g) Toilet tissue. A continuous supply of toilet tissue shall be provided in permanently installed dispensing devices. Pf
ATCP 76.33(2)(h)(h) Bathing suits provided. If bathing suits, towels, or caps are furnished to patrons they shall meet all of the following:
ATCP 76.33(2)(h)1.1. Be thoroughly laundered with detergent and machine dried after each use.
ATCP 76.33(2)(h)2.2. Clean suits, towels, and caps shall be stored separately from unlaundered articles.
ATCP 76.33(2)(i)(i) Hose bibbs. Hose bibbs shall be conveniently located so floors in the shower, dressing, and toilet facilities can be adequately rinsed.
ATCP 76.33(3)(3)Garbage and refuse. Garbage and refuse shall meet all of the following:
ATCP 76.33(3)(a)(a) Approved storage container. All garbage and refuse shall be stored in metal or rigid plastic containers having tight–fitting lids.
ATCP 76.33(3)(b)(b) Sufficient in number. A sufficient number of containers shall be provided for all garbage and refuse generated.
ATCP 76.33(3)(c)(c) Stored to prevent harborage conditions. Filled containers of garbage or refuse shall meet all of the following and be covered and stored in a manner to prevent:
ATCP 76.33(3)(c)1.1. Harborage of rodents, insect attraction, and breeding areas.Pf
ATCP 76.33(3)(c)2.2. Odors. Pf
ATCP 76.33(3)(c)3.3. Environmental pollution. Pf
ATCP 76.33(3)(c)4.4. Accidents. Pf
ATCP 76.33(3)(d)(d) Disposal as needed. The contents of the containers shall be disposed of as needed and in a sanitary manner.
ATCP 76.33(3)(e)(e) Clean condition. All containers shall be kept clean.
ATCP 76.33(3)(f)(f) Good repair. Containers shall be maintained in good repair.
ATCP 76.33(4)(4)Water heaters, ventilation, electrical. Water heaters, ventilation, and electrical shall meet the following:
ATCP 76.33(4)(a)(a) Operating condition. Water heaters and heat exchangers shall be maintained in operating condition.
ATCP 76.33(4)(b)(b) Air movement. Heating, ventilation, and exhaust equipment shall be maintained and operated to provide air movement pursuant to chs. SPS 361 to 365, to prevent any excessive condensation and air quality problems in indoor enclosures, as enforced by the Wisconsin department of safety and professional services.
ATCP 76.33(4)(c)(c) Maintained in good repair. Electrical equipment and lighting shall be maintained in good repair and in operating condition.
ATCP 76.33(4)(d)(d) Carbon monoxide alarms. The operator shall install functioning carbon monoxide alarms, as applicable and meet all of the following:
ATCP 76.33(4)(d)1.1. A pool equipment room that has a fuel burning appliance shall install and maintain a carbon monoxide alarm. P
ATCP 76.33(4)(d)2.2. For indoor pools, a carbon monoxide alarm shall be installed and maintained in the pool area, if there is a fuel burning appliance in the equipment room that is also located within the pool area. P
ATCP 76.33 HistoryHistory: CR 22-021: cr. Register June 2023 No. 810, eff. 9-24-23.
ATCP 76.335ATCP 76.335Dog swims. A pool operator shall ensure all of the following during dog swim events:
ATCP 76.335(1)(1)Operation.
ATCP 76.335(1)(a)(a) Water level. Before the dog swim event, the water level shall be adjusted so that the pool water in the basin does not enter the recirculation system. P
ATCP 76.335(1)(b)(b) Disinfectant residual. Initial disinfectant residual must be 4 ppm free chlorine or 8 ppm if cyanuric acid present. P
Loading...
Loading...
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date the chapter was last published.