SPS 318.1004 (10) (ag) “Dumbwaiter” has the meaning as given in s. 101.981 (1) (d), Stats. section 37.
SPS 318.1004 (10) (b) (Note) is repealed.section 38.
SPS 318.1004 (10) (g), (i), and (L) are amended to read:SPS 318.1004 (10) (g) “Orchestra elevator pit lift” means a permanent powered hoisting and lowering mechanism which is within or adjacent to a theatrical or musical stage and which is intended to accommodate musicians performers and their equipment. “Orchestra pit lift” includes orchestra elevators and stage elevators.
(i) “Passenger elevator" means an elevator used primarily to carry persons other than the operator and persons necessary for loading and unloading. This term does not include limited-use, limited-application elevators, elevators in dwelling units, stage and orchestra elevators orchestra pit lifts, special purpose personnel elevators, sidewalk elevators, and rooftop elevators, and type B material lifts.
(L) “Sidewalk elevator" means an elevator of the freight type a device with on-car controls for the raising or lowering of materials operating between a landing in a sidewalk or other exterior area and floors below the sidewalk or grade level and that opens onto the exterior area through a horizontal opening.
section 39.
SPS 318.1004 (10) (n) is repealed.section 40.
SPS 318.1004 (10) (om) is created to read: SPS 318.1004 (10) (om) “Type B material lift” means a powered hoisting and lowering mechanism used for carrying material and on which only the operator or the person necessary for unloading and loading the material is permitted to ride.
section 41.
SPS 318.1004 (12) (Note) is repealed.section 42.
SPS 318.1004 (12e), (12m), and (12s) are created to read:SPS 318.1004 (12e) “Electrical code” means ch. SPS 316, which is the Wisconsin Electrical Code. (12m) “First-aid treatment” has the meaning given “first aid” in 29 CFR 1904.7 (b) (5) (ii), regardless of who is providing the treatment. (12s) “Hoistway” means a shaft or opening through a building or structure for the travel of elevators, dumbwaiters, or material lifts, extending from the pit floor to a ceiling above.
section 43.
SPS 318.1005 (1) (intro), (a), and (b) are amended to read:SPS 318.1005 (1) (intro) Primary standards. The following ASME standards are hereby incorporated by reference into this chapter, subject to the modifications specified in this chapter:
(a) Safety Code for Elevators and Escalators, ASME A17.1–2013 2016/CSA B44–13 16.
(b) Safety Standard for Platform Lifts and Stairway Chairlifts, ASME A18.1–2011 2017.
section 44.
SPS 318.1005 (1) (c) is created to read:SPS 318.1005 (1) (c) Entertainment Technology-Design, Installation, and Use of Orchestra Pit Lifts, ANSI E1.42-2018.
section 45.
SPS 318.1007 (1) (b) (Note) is repealed.section 46.
SPS 318.1007 (2) (c) 1. a. is amended to read:SPS 318.1007 (2) (c) 1. a. A At least 3 copies of the completed application, on an approved form.
section 47.
SPS 318.1007 (2) (c) 1. a. (Note) is repealed and recreated to read:SPS 318.1007 (2) (c) 1. a. (Note): Forms required under this chapter are available on the department's website at https://dsps.wi.gov, or by request from the Department of Safety and Professional Services, P. O. Box 7302, Madison, Wisconsin 53708, or call (608) 266-2112. section 48.
SPS 318.1007 (2) (c) 3. b. (Note) is created to read:SPS 318.1007 (2) (c) 3. b. Note: Where the scope of work for an escalator includes a replacement of the majority of internal parts, even if retaining the majority of the truss, that is considered a new installation under this subdivision.
section 49.
SPS 318.1007 (3) (title), (a) (intro) and 1. are amended to read:SPS 318.1007 (3) (title) Alterations Scope of alterations, repairs, and replacements. (a) (intro) For proposed alterations and , repairs, or replacements listed in Table SPS 318.1007-1 Items 1. to 4. and Tables SPS 318.1007-2, 318.1007-3, and 318.1007-4, all of the following shall be submitted with the request for approval:
1. A At least 3 copies of the completed application, on an approved form, if the submittal is to the department.
section 50.
SPS 318.1007 (3) (a) 1. (Note) is repealed and recreated to read:SPS 318.1007 (3) (a) 1. (Note): Forms required under this chapter are available on the department's website at https://dsps.wi.gov, or by request from the Department of Safety and Professional Services, P. O. Box 7302, Madison, Wisconsin 53708, or call (608) 266-2112. section 51.
Tables SPS 318.1007-1, SPS 318.1007-2, SPS 318.1007-3, and SPS 318.1007-4 are amended to read:Table SPS 318.1007-1
Elevators and Orchestra Pit Lifts
1. | Change to Alteration or replacement of hoistway enclosure walls, pit, or ceiling; or to number or location of landings served |
2. | Change to Alteration of machine-room, machinery-space, control-room, or control-space walls, floor, ceiling, or entrance; or to location of machinery |
3. | Conversion Alteration of passenger elevator to freight type, or freight to passenger type |
4. | Change in class Alteration of loading class for a freight elevator |
5. | Change to complete Alteration of traction driving machine, motor, sheave, and driving machine brake, or emergency brake |
6. | Replacement of entire driving machine, driving machine brake, or emergency brake |
7. | Installation of a fire sprinkler in a machine room, machinery space, control room, control space, or top of hoistway |
7 8. | Increase in loading of more than 5% to machinery, beams, supports, or foundations |
8 9. | Change to type of or addition Alteration of hoistway door or gate |
910. | Installation or addition Alteration of hoistway-door interlock or combination mechanical lock and contacts |
1011. | Change to or addition of non-contact Alteration of a solely contact type to another type of reopening device on an elevator with firefighters’ emergency operation |
1112. | Increase or decrease of more than 5% of the total load of car deadweight plus rated load |
1213. | Change Increase or decrease in rated load |
1314. | Change Increase or decrease in speed of more than 5% |
1415. | Change Alteration or replacement of safety device |
1516. | Change of or repair to speed Alteration or replacement of overspeed governor |
1617. | Change in type or addition Alteration or addition of an emergency brake or device protecting against unintended movement or ascending car overspeed |
1718. | Change in Alteration to suspension member, type, material, grade, number or size, equalizers, fastening, or monitoring as defined in ASME A17.1 sections 8.7.2.21 and 8.7.3.25 |
1819. | Increase in stresses of more than 5% to guiderails, supports, and fastenings |
1920. | Change Alteration to type or location of car or counterweight buffer or bumper |
2021. | Change Alteration to type of terminal stopping device |
2122. | Change Alteration to or addition of a top-of-car operating device |
2223. | Change Replacement of controller |
2324. | Change in Alteration to type of motion control |
2425. | Change in Alteration to type of operation control |
25. | Change to or addition of a car emergency signaling device |
26. | Change or connection to Addition of emergency or standby power system |
27. | Change Alteration to or addition of firefighters’ emergency operation system |
28. | Change Alteration to or addition of auxiliary power supply raising or lowering operation |
29. | Change to or installation Replacement or addition of a plunger gripper |
30. | Change to Replacement of a complete hydraulic driving machine pumping unit including motor, pump, and tank |
31. | Change to Alteration or replacement of hydraulic control valve |
32. | Change to Alteration or replacement of hydraulic plunger or cylinder |
33. | Increase in hydraulic working pressure of more than 5% |
34. | Removal or disabling of devices subject to ASME A17.1 section 8.6.1.7.5 |
Table SPS 318.1007-2
Escalators and Moving Walks
1. | Change to Alteration or repair of truss |
2. | Change Alteration to rated speed or installation of speed varying system |
3. | Installation or addition of skirt brushes |
4. | Alterations to safety component or safety switch as defined in ASME A17.1 sections 6.1.6.3 and 6.2.6.3, ‘Electrical protective device’ |
Table SPS 318.1007-3
Dumbwaiters and Type B Material Lifts
1. | Increase or decrease in rated load |
2. | Change Increase or decrease in speed of more than 5% |
3. | Change Alteration to car size |
Table SPS 318.1007-4
Platform Lifts
1. | Change to safety or speed governor Alteration to or replacement of overspeed or slack suspension safety device |
2. | Change Alteration to or replacement of hydraulic jack plunger or cylinder |
3. | Change Alteration to or replacement of hydraulic valve |
4. | Change Alteration to or addition of machine room |
section 52.
SPS 318.1008 (2) (e) 3. is created to read:SPS 318.1008 (2) (e) 3. a. On the date specified by the department under subd. 3. b.
b. The department may, notwithstanding subds. 1. and 2., specify a shorter period of time at the time the approval is issued, which shall be no later than 2 years after the approval date shown on the approved plans. Upon request to the secretary, the expiration date may be extended for a one-time, 2-year period at the discretion of the secretary provided the written request is submitted prior to expiration of the original approval.
section 53.
SPS 318.1011 (3) is repealed.section 54.
SPS 318.1011 (7) (bm) is created to read:SPS 318.1011 (7) (bm) Elevator mechanic. The installation contractor or the owner or owner’s agent shall make arrangements to ensure that a licensed elevator mechanic or a licensed elevator mechanic-restricted is present for the inspection of the conveyance or related equipment during the entire inspection.
section 55.
SPS 318.1011 (8) (intro) is amended to read:SPS 318.1011 (8) (intro) Inspection report. Where an inspection specified in sub. (2), (5), or (6) is performed by someone other than an a licensed elevator inspector of the department or an agent municipality, the licensed elevator inspector shall file an inspection report with the department in accordance with all of the following:
section 56.
SPS 318.1011 (8) (a) (Note) is repealed.section 57.
SPS 318.1011 (8) (b) (Note) is repealed and recreated to read:SPS 318.1011 (8) (b) (Note): Forms required under this chapter are available on the department's website at https://dsps.wi.gov, or by request from the Department of Safety and Professional Services, P. O. Box 7302, Madison, Wisconsin 53708, or call (608) 266-2112. section 58.
SPS 318.1011 (8) (c) 2. b. and 3. are amended to read: