SPS 391.03(9)(9)“Vault privy” means an enclosed nonportable toilet into which nonwater-carried human wastes are deposited to a subsurface storage chamber that is watertight.
SPS 391.03 HistoryHistory: Cr. Register, April, 2000, No. 532, eff. 7-1-00; CR 04-072: renum. (1) to (6) to be (2), (3), (5) to (7) and (9), cr. (1), (4) and (8), Register July 2005 No. 594, eff. 1-1-06; correction in (3) made under s. 13.92 (4) (b) 6., Stats., Register December 2011 No. 672.
SPS 391.04SPS 391.04Registrations. The installation of a vault privy or a pit privy to serve a state-owned facility shall be registered with the department prior to installation. The registration of a vault privy shall be accompanied by sufficient information to determine compliance with s. SPS 384.25. The registration of a pit privy shall be accompanied by sufficient soil information to determine compliance with s. SPS 383.44 (4) (b).
SPS 391.04 HistoryHistory: CR 02-129: cr. Register January 2004 No. 577, eff. 2-1-04; correction made under s. 13.92 (4) (b) 7., Stats., Register December 2011 No. 672.
SPS 391.10SPS 391.10Composting toilet systems.
SPS 391.10(1)(1)The materials, design, construction and performance of a composting toilet system shall conform to NSF Standard 41.
SPS 391.10(2)(2)All composting toilet systems shall be listed by a testing agency acceptable to the department.
SPS 391.10 NoteNote: Listing agencies acceptable to the department include the American Gas Association; Canadian Standards Association; NSF International; Underwriter’s Laboratories; and Warnock Hersey.
SPS 391.10(3)(a)(a) Components for the storage or treatment of wastes shall be continuously ventilated.
SPS 391.10(3)(b)(b) Ventilation ducts or vents for the composting toilet system shall conform to s. SPS 382.31 (16).
SPS 391.10 NoteNote: See appendix for a reprint of portions of s. SPS 382.31 (16).
SPS 391.10(4)(a)(a) The disposal of the compost shall be in accordance with 40 CFR part 503.
SPS 391.10(4)(b)(b) The disposal of any liquid from a composting toilet system shall be either to a public sanitary sewer system or a POWTS conforming to ch. SPS 383.
SPS 391.10 HistoryHistory: Cr. Register, April, 2000, No. 532, eff. 7-1-00; correction in (3) (b), (4) (b) made under s. 13.92 (4) (b) 7., Stats., Register December 2011 No. 672; CR 17-065: am. (4) (a) Register June 2018 No. 750, eff. 7-1-18.
SPS 391.11SPS 391.11Incinerating toilets.
SPS 391.11(1)(1)The design, construction and installation of a gas-fired incinerating toilet shall conform to ANSI Z21.61.
SPS 391.11(2)(2)The materials, design, construction, and performance of an electric-fired incinerating toilet shall conform to NSF Protocol P157.
SPS 391.11(3)(3)All electric and gas-fired incinerating toilets shall be listed by a testing agency acceptable to the department.
SPS 391.11 NoteNote: Listing agencies acceptable to the department include the American Gas Association, Canadian Standards Association, NSF International, Underwriter’s Laboratories, and Warnock Hersey.
SPS 391.11(4)(a)(a) The disposal of the end product shall be of in accordance with 40 CFR Part 503, Standards for the Use or Disposal of Sewage Sludge.
SPS 391.11 NoteNote: Materials relating to 40 CFR part 503, including, “Domestic Septage Regulatory Guidance: A Guide to the EPA 503 Rule”, are available at epa.org.
SPS 391.11(4)(b)(b) The disposal of any liquid from an incinerating toilet shall be either to a public sanitary sewer system or a POWTS conforming to ch. SPS 383.
SPS 391.11 HistoryHistory: Cr. Register, April, 2000, No. 532, eff. 7-1-00; correction in (4) (b) made under s. 13.92 (4) (b) 7., Stats., Register December 2011 No. 672; CR 17-065: am. (2) Register June 2018 No. 750, eff. 7-1-18.
SPS 391.12SPS 391.12Privies.
SPS 391.12(1)(a)(a) The storage chamber of a vault privy shall conform with the requirements of s. SPS 384.25 relating to holding tanks, and shall have a minimum storage capacity of 200 gallons or one cubic yard.
SPS 391.12(1)(b)1.1. The storage chamber of a pit privy shall be sited and located in soil recognized to provide treatment and dispersal in accordance with s. SPS 383.44 (4) (b).
SPS 391.12 NoteNote: Chapter SPS 385 establishes procedures for conducting soil evaluations and preparing soil evaluation reports. Section SPS 305.33 delineates the qualifications and certification procedures for individuals who conduct soil evaluations.
SPS 391.12(1)(b)2.2. Governmental units may set standards for the structure above the vault or pit for one- and two-family dwellings.
SPS 391.12(1)(b)3.3. Privies for public use shall meet the requirements of this section and chs. SPS 361 to 366.
SPS 391.12 NoteNote: Chapters NR 811 and 812 establish minimum separation distances between a pit or vault privy and a potable well. Chapters NR 811 and 812 are administered by the department of natural resources.
SPS 391.12(1)(c)(c) The storage chamber of a vault privy shall be anchored to prevent flotation caused by saturated soil conditions.
SPS 391.12(2)(a)(a) The storage chamber of a pit or vault privy shall be provided with a vent for the purpose of relieving explosive gases.
SPS 391.12(2)(b)(b) The vent serving the storage chamber of a privy shall be:
SPS 391.12(2)(b)1.1. At least 3 inches in diameter;
SPS 391.12(2)(b)2.2. Installed in accordance with s. SPS 382.31 (16) (a) to (f); and
SPS 391.12(2)(b)3.3. Fabricated or provided with screening to prevent insects from entering the storage chamber.
SPS 391.12(3)(3)The servicing of a vault privy relative to the pumping, transporting and disposal of the contents shall be in accordance with ch. NR 113.
SPS 391.12(4)(4)The abandonment of a vault privy shall be accomplished by:
SPS 391.12(4)(a)(a) Having the contents of the storage chamber pumped and disposed of in accordance with ch. NR 113;
SPS 391.12(4)(b)(b) Removing the entire top of the chamber; and
SPS 391.12(4)(c)(c) Filling the remaining portion of the emptied storage chamber with soil or other inert material to an elevation equal to or above the surrounding grade.
SPS 391.12(5)(5)The abandonment of a pit privy shall be accomplished by filling the storage chamber with soil or other inert material to an elevation equal to the surrounding grade.
SPS 391.12 NoteNote: The requirements of the commercial building code, chs. SPS 361 to 366, apply to the structures built over those privies serving public buildings and places of employment.
SPS 391.12(6)(a)(a) A privy may not be installed in a floodway.
SPS 391.12(6)(b)(b) A privy may be installed in the floodfringe provided that the area is filled to remove it from the floodfringe designation or the vault is flood-proofed.
SPS 391.12 NoteNote: The department of natural resources determines if filling or flood-proofing is in accordance with current rules in effect for development in a floodfringe area.
SPS 391.12 HistoryHistory: Cr. Register, April, 2000, No. 532, eff. 7-1-00; CR 01-139: am. (1) (b) 3. Register June 2002 No. 558, eff. 7-1-02; correction in (1) (a), (b) 1., 3., (2) (b) 2. made under s. 13.92 (4) (b) 7., Stats., Register December 2011 No. 672.
SPS 391.13SPS 391.13Portable restrooms.
SPS 391.13(1)(1)The storage chamber of a portable restroom into which human waste is to be deposited shall be watertight.
SPS 391.13(2)(2)The entire floor and the side walls to a height of not less than 4 inches of a portable restroom shall be of a material impervious to water.
SPS 391.13 HistoryHistory: Cr. Register, April, 2000, No. 532, eff. 7-1-00.
SPS 391.14SPS 391.14Equal speed of access to toilets.
SPS 391.14(1)(1)Application. This section applies to the toilet fixtures in separate-gender restrooms serving an amusement facility and a specialty events center where the public congregates that are constructed or renovated on or after January 1, 2006 only if one of the following occurs:
SPS 391.14(1)(a)(a) New separate-gender restrooms are constructed or separate-gender toilets are provided, in which case this section applies only to the new restrooms.
SPS 391.14(1)(b)(b) More than 50 percent of the square footage of an existing separate-gender restroom is renovated, in which case this section applies only to the renovated portion.
SPS 391.14 NoteNote: Under section 101.128 (1) (d), Stats., “ ‘renovation’ means any structural remodeling, improvement or alteration of an existing facility where the public congregates. ‘Renovation’ does not include any of the following:
SPS 391.14 Note1. Reroofing.
SPS 391.14 Note2. Cosmetic remodeling, including painting or the installation of wall covering, of paneling, of floor covering or of suspended ceilings.
SPS 391.14 Note3. An alteration to an electrical or mechanical system.”
SPS 391.14(2)(2)Number of toilet facilities. When separate public restrooms or other toilet facilities are provided for males and females at an amusement facility and a specialty event center where the public congregates, the number of toilets for the females shall be provided at a ratio of 2 for every toilet and every urinal provided for the males.
SPS 391.14 HistoryHistory: CR 04-072: cr. Register July 2005 No. 594, eff. 1-1-06; CR 17-065: am. (1) (b) Register June 2018 No. 750, eff. 7-1-18.
SPS 391.20SPS 391.20Incorporation of standards by reference.
SPS 391.20(1)(1)Consent. Pursuant to s. 227.21, Stats., the attorney general has consented to the incorporation by reference of the standards listed in sub. (3).
SPS 391.20(2)(2)Copies. Copies of the adopted standards are on file in the offices of the department and the legislative reference bureau. Copies of the standards may be purchased through the respective organizations listed in sub. (3).
SPS 391.20(3)(3)Adoption of standards. The standards referenced in pars. (a) to (c) are incorporated by reference into this chapter.
SPS 391.20(3)(a)(a) ANSI Z21.61-1983: Gas-Fired Toilets, American National Standard Institute, 25 West 43rd Street, 4th Floor, New York, NY 10036.
SPS 391.20(3)(b)(b) NSF 41-2016: Non-Liquid Saturated Treatment Systems, NSF International, 6300 Interfirst Drive, Ann Arbor, MI 48108.
SPS 391.20(3)(c)(c) NSF Protocol P157-2014: Electrical Incinerating Toilets – Health and Sanitation, NSF International, 6300 Interfirst Drive, Ann Arbor, MI 48108.
SPS 391.20 HistoryHistory: Cr. Register, April, 2000, No. 532, eff. 7-1-00; correction in (2) made under s. 13.92 (4) (b) 6., Stats., Register December 2011 No. 672; CR 17-065: am. (1), (2), (3) (intro.), r. and recr. (3) (a), (b), cr. (3) (c) Register June 2018 No. 750, eff. 7-1-18; correction in (3) (intro.) made under s. 35.17, Stats., Register June 2018 No. 750.
Loading...
Loading...
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date the chapter was last published.