This is the preview version of the Wisconsin State Legislature site.
Please see http://docs.legis.wisconsin.gov for the production version.
SPS 366.0904(1)(1)Upholstered furniture. The requirement in IEBC section 904.1.3 condition 3 is not included as part of chs. SPS 361 to 366.
SPS 366.0904(2) (2) Fire alarm and detection systems. Substitute the requirements from 2009 IEBC section 804.2 for the requirements in IEBC section 904.2.
SPS 366.0904 History History: CR 16-094: cr. Register April 2018 No. 748, eff. 5-1-18.
SPS 366.0909 SPS 366.0909Level 3 alterations plumbing. These are department rules in addition to the requirements in IEBC chapter 9:
SPS 366.0909(1) (1)Pursuant to s. 101.128, Stats., level 3 alterations within an existing facility where the public congregates shall necessitate that plumbing fixtures serving the work area be provided in a ratio of at least 2 water closets for females as to each water closet and urinal for the males.
SPS 366.0909(2)(a)(a) Under this section “facility where the public congregates" has the meaning has given in s. 101.128 (1) (b), Stats.
SPS 366.0909 Note Note: Section 101.128 (1) (b), Stats., reads: “Facility where the public congregates" means any of the following that has a general capacity or a seating capacity of 500 or more persons:
SPS 366.0909 Note 1. An amusement facility.
SPS 366.0909 Note 2. A convention or trade hall or center.
SPS 366.0909 Note 3. A specialty event center.
SPS 366.0909 Note 4. A sports or entertainment arena, center or building.
SPS 366.0909 Note 5. A stadium.
SPS 366.0909 Note 6. An airport, bus terminal, train station or other transportation center.
SPS 366.0909(2)(b) (b) Under this section “alterations" has the meaning has given in s. 101.128 (1) (d), Stats., for “renovation".
SPS 366.0909 Note Note: Section 101.128 (1) (d), Stats., reads: “Renovation" means any structural remodeling, improvement or alteration of an existing facility where the public congregates. “Renovation" does not include any of the following:
SPS 366.0909 Note 1. Reroofing.
SPS 366.0909 Note 2. Cosmetic remodeling, including painting or the installation of wall covering, of paneling, of floor covering or of suspended ceilings.
SPS 366.0909 Note 3. An alteration to an electrical or mechanical system.
SPS 366.0909 History History: CR 06-120: cr. Register February 2008 No. 626, eff. 3-1-08; CR 16-094: renum. from 366.0809 and am. (intro.) REgister April 2018 No. 748, eff. 5-1-18; correction in (title) made under s. 13.92 (4) (b) 2., Stats., Register April 2018 No. 748.
SPS 366.1001 SPS 366.1001Change of occupancy.
SPS 366.1001(1)(1)change of occupancy approval. Substitute the following wording for the requirements in IEBC section 1001.2: A change of occupancy or a change of occupancy within a space where there is a different fire protection system threshold requirement in IBC chapter 9 may not be made to any structure without the approval of the code official. An increased occupant load may trigger additional means of egress or fire protection requirements.
SPS 366.1001(2) (2) Change of occupancy classification. This is a department rule in addition to the requirements in IEBC section 1001.2.2: Buildings undergoing a change in occupancy that would result in an increase in demand for either fossil fuel or electrical energy shall comply with the IECC.
SPS 366.1001(3) (3) Certification of occupancy required. The requirements in IEBC section 1001.3 are not included as part of chs. SPS 361 to 366.
SPS 366.1001 History History: CR 06-120: cr. Register February 2008 No. 626, eff. 3-1-08; CR 10-103: am. (1) Register August 2011 No. 668, eff. 9-1-11; CR 16-094: renum. (title), (1) to (3) from 366.0901 (title), (1) to (3) and am., renum. (4) to SPS 366.1012 Register April 2018 No. 748, eff. 5-1-18.
SPS 366.1010 SPS 366.1010Change of occupancy plumbing. Substitute the following wording for the requirements in IEBC section 1010: Where the occupant load of a story is increased by more than 20 percent, plumbing fixtures for the story shall be provided in quantities specified in the IBC based on the increased occupant load.
SPS 366.1010 History History: CR 06-120: cr. Register February 2008 No. 626, eff. 3-1-08; CR 10-103: renum. from Comm 66.0910 Register August 2011 No. 668, eff. 9-1-11; CR 16-094: renum. from 366.0912 and am. Register April 2018 No. 748, eff. 5-1-18; correction in (title) made under s. 13.92 (4) (b) 2., Stats., Register April 2018 No. 748.
SPS 366.1011 SPS 366.1011Other requirements.
SPS 366.1011(1)(1)Elevator recall. This is a department rule in addition to the requirements in IEBC section 1011: At least one existing elevator shall be provided with emergency recall operation and emergency in-car operation complying with ch. SPS 318 when an existing building or structure that is greater than 60 feet in height is changed to include a Group R-1 or R-2 occupancy.
SPS 366.1011(2) (2) Carbon monoxide alarms. This is a department rule in addition to the requirements in IEBC section 1011: A building or a portion of a building changed to be or include a residential building as defined under s. 101.149 (1) (b), Stats., shall be provided with carbon monoxide alarms or detectors in accordance with s. SPS 362.0915.
SPS 366.1011 History History: CR 06-120: cr. Register February 2008 No. 626, eff. 3-1-08; EmR0826: emerg. renum. to be (1), cr. (1) (title) and (2), eff. 10-1-08; CR 08-085: renum. to be (1), cr. (1) (title) and (2) Register May 2009 No. 641, eff. 6-1-09; correction in (1), (2) made under s. 13.92 (4) (b) 7., Stats., Register December 2011 No. 672; CR 16-094: renum. from 366.0911 and am. Register April 2018 No. 748, eff. 5-1-18; correction in (2) under s. 13.92 (4) (b) 7., Stats., Register April 2018 No. 748.
SPS 366.1012 SPS 366.1012Standpipe systems. This is a department rule in addition to the requirements in IEBC section 1012.2: Standpipe systems shall be provided in existing buildings and structures or portions of existing buildings and structures in accordance with IBC chapter 9 when existing buildings or structures that are greater than 60 feet in height are changed to include a Group R-1 or R-2 occupancy.
SPS 366.1012 History History: CR 16-094: renum. SPS 366.0901 (4) and am. Register April 2018 No. 748, eff. 5-1-18.
SPS 366.1102 SPS 366.1102Heights and areas.
SPS 366.1102(1)(1)Area limitations. This is a department exception in addition to the exception in IEBC section 1102.2: Buildings meeting the legacy Wisconsin unlimited area provisions are allowed to have unlimited area additions per the current code without a separating firewall.
SPS 366.1102(2) (2) Fire protection systems. This is a department exception to the requirements in IEBC section 1102.3: An automatic sprinkler system is not required for additions to individual dwelling units within existing townhouses that are not already protected with an automatic sprinkler system.
SPS 366.1102 History History: CR 10-103: cr. Register August 2011 No. 668, eff. 9-1-11; CR 16-094: cr. (title), (1), renum. (2) from 366.1002 and am. Register April 2018 No. 748, eff. 5-1-18.
SPS 366.1201 SPS 366.1201Historic buildings.
SPS 366.1201(1)(1)Scope. This is a department rule in addition to the requirements in IEBC section 1201.1: Any historic building is exempt from the energy requirements of chs. SPS 361 to 366.
SPS 366.1201(2) (2) Report. The requirements in IEBC section 1202.2 are not included as part of chs. SPS 361 to 366.
SPS 366.1201 History History: CR 06-120: cr. Register February 2008 No. 626, eff. 3-1-08; CR 10-103: renum. (1) to be (2), (2) to be Comm 66.1105 and am. (2) (title), cr. (1) Register August 2011 No. 668, eff. 9-1-11; CR 16-094: renum. from 366.1101 and am. Register April 2018 No. 748, eff. 5-1-18.
SPS 366.1204 SPS 366.1204Historic buildings alterations. Historic buildings are not required to comply with the IECC for building envelope compliance except as follows:
SPS 366.1204(1) (1)Existing ceiling, wall, or floor cavities exposed during alterations shall be filled with insulation.
SPS 366.1204(2) (2)All replacement skylight, window, and/or door assemblies shall meet the minimum code requirements of the IECC unless specifically designed to address unique aesthetics associated with the historic nature of the building. Glass only replacements in an existing sash and frame are exempt from the application of the IECC.
SPS 366.1204(3) (3)Roofs without insulation in the cavity and where the sheathing or insulation is exposed during reroofing shall be insulated either above or below the sheathing so as to meet the minimum insulation required by the IECC, or shall provide insulation to the greatest extent possible.
SPS 366.1204 History History: CR 16-094: cr. Register April 2018 No. 748, eff. 5-1-18; correction in (title) made under s. 13.92 (4) (b) 2., Stats., Register April 2018 No. 748.
SPS 366.1205 SPS 366.1205Exhibit buildings. These are department rules in addition to the requirements in IEBC section 1205: Historic buildings to be used as exhibit buildings shall comply with all of the following requirements:
SPS 366.1205(1) (1)The building shall be open to the public only under the supervision of a tour guide.
SPS 366.1205(2) (2)The building may not be lived in, slept in or worked in, except for the purpose of demonstrating to the public how people lived in a particular era.
SPS 366.1205(3) (3)Smoking is prohibited in the building.
SPS 366.1205(4) (4)Open flame equipment may not be used in the building, except for fire places and other mechanical equipment original to the building.
SPS 366.1205(5) (5)Fire extinguishers shall be installed in exhibit buildings and may be located in a nonconspicuous location but accessible to the occupants.
SPS 366.1205(6)(a)(a) At least one smoke detector shall be provided for each 1,200 square feet of floor area with a minimum of one smoke detector per floor level.
SPS 366.1205(6)(b)1.1. Except as specified in subd. 2., where electricity is provided in the exhibit building, the smoke detectors shall be connected to the electrical power.
SPS 366.1205(6)(b)2. 2. Where no electrical power is provided to an exhibit building, the smoke detectors shall be of a battery type.
SPS 366.1205(6)(b)3. 3. Smoke detectors shall be tested weekly.
SPS 366.1205(7) (7)Exhibit buildings provided with only one means of egress shall be restricted to a total capacity of 12 people, and not more than 6 people may be located above or below the first floor at any one time.
SPS 366.1205(8) (8)Stairways without 6-foot, 4-inch vertical headroom clearance shall have signs posted warning occupants of the headroom clearance available.
SPS 366.1205(9) (9)Exit signs shall be provided in accordance with the prevailing code in exhibit buildings occupied prior to ½-hour before sunrise and ½-hour after sunset and in all areas not provided with natural lighting.
SPS 366.1205 History History: CR 10-103: renum. from Comm 66.1101 (2) Register August 2011 No. 668, eff. 9-1-11; correction in (b) 1. made under s. 13.92 (4) (b) 7., Stats., Register August 2011 No. 668; CR 16-094: renum. from 366.1105 and am. (intro.) Register April 2018 No. 748, eff. 5-1-18.
SPS 366.1401 SPS 366.1401Performance compliance methods.
SPS 366.1401(1)(1)Applicability. Substitute the following wording for the requirements in IEBC section 1401.2: The provisions of sections 1401.2.1 through 1401.2.5 shall apply to existing occupancies that will continue to be, or are proposed to be, in Groups A, B, E, F, M, R, and S. These provisions may not apply to buildings with occupancies in Group H or Group I.
SPS 366.1401(2) (2) Accessibility requirements. Substitute the following wording for the requirements in IEBC section 1401.2.5: All portions of the buildings proposed for change of occupancy or being altered shall conform to the accessibility provisions of IEBC section 410.
SPS 366.1401(3) (3) Other codes. The requirements in IEBC section 1401.3.2 are not included as part of chs. SPS 361 to 366.
SPS 366.1401(4) (4) Minimum plumbing fixtures. This is a department rule in addition to the requirements in IEBC section 1401.2: Where the occupant load of a story is increased by more than 20 percent, plumbing fixtures for the story shall be provided in quantities specified in the IBC based on the increased occupant load.
SPS 366.1401 History History: CR 06-120: cr. Register February 2008 No. 626, eff. 3-1-08; CR 10-103: am. (title), renum. (2) to be (3), cr. (2) Register August 2011 No. 668, eff. 9-1-11; CR 16-094: renum. from 366.1301 and am., cr. (4) Register April 2018 No. 748, eff. 5-1-18; correction in (2) made under s. 13.92 (4) (b) 7., Stats., Register December 2023 No. 816, eff. 1-1-24.
SPS 366.1500 SPS 366.1500Construction safeguards. The requirements in IEBC chapter 15 are not included as part of chs. SPS 361 to 366.
SPS 366.1500 History History: CR 10-103: cr. Register August 2011 No. 668, eff. 9-1-11; CR 16-094: renum. from 366.1400 and am. Register April 2018 No. 748, eff. 5-1-18.
Loading...
Loading...
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date the chapter was last published.