SPS 363.5303 Note Note: Use of the ASHRAE Handbook of Fundamentals standard in effect at the time of publication of the 2015 IECC constitutes compliance with this section.
SPS 363.5303(2) (2)Exceptions.
SPS 363.5303(2)(a)(a) When the information is not available from ASHRAE Handbook of Fundamentals, the data shall be obtained from laboratory or field-test measurements. If laboratory or field test measurements are used for envelope heat transmission, the measurements shall be obtained using one of the following test methods:
SPS 363.5303(2)(a)1. 1. ASTM C177-13, Test method by guarded hot plate apparatus.
SPS 363.5303(2)(a)2. 2. ASTM C335/335M-10, Test method of horizontal pipe insulation.
SPS 363.5303(2)(a)3. 3. ASTM C518-15, Test method by means of the heat flow meter apparatus.
SPS 363.5303(2)(a)4. 4. ASTM C1363-11, Test method by means of a hot box apparatus.
SPS 363.5303(2)(b) (b) For foam plastic insulation that incorporates a substance other than air as the insulating medium, laboratory or field tests shall be conducted on representative samples that have been aged for the equivalent of 5 years or until the R-Value has stabilized to determine thermal properties or performance. The tests shall be conducted by an independent third party.
SPS 363.5303(2)(c) (c) Integrally insulated concrete masonry systems within the scope of the National Concrete Masonry Association (NCMA) shall be evaluated for the thermal performance of the masonry or concrete units in accordance with one of the following:
SPS 363.5303(2)(c)1. 1. NCMA Evaluation Procedures for the Integrally-Insulated Concrete Masonry Walls.
SPS 363.5303(2)(c)2. 2. Default values as approved by the department.
SPS 363.5303(2)(d) (d) All other concrete or masonry units not within the scope of the NCMA Evaluation Procedures shall comply with one of the following methods for determining the thermal performance of the assembly or system:
SPS 363.5303(2)(d)1. 1. Default values as approved by the department.
SPS 363.5303(2)(d)2. 2. Laboratory or field-test measurements specified in par. (a).
SPS 363.5303(2)(d)3. 3. Department material approval process as specified in ch. SPS 361 to determine the U-factor.
SPS 363.5303 History History: CR 16-094: cr., Register April 2018 No. 748 eff. 5-1-18.
SPS 363.5401 SPS 363.5401 Certificate. The requirements in IECC section R401.3 are not included as part of chs. SPS 361 to 366.
SPS 363.5401 History History: CR 06-120: cr. Register February 2008 No. 626, eff. 3-1-08; CR 16-094: renum. 363.5401 from 363.0401 and am., Register April 2018 No. 748 eff. 5-1-18.
SPS 363.5402 SPS 363.5402Building envelope requirements.
SPS 363.5402(1)(1) Insulation and fenestration requirements by component. Substitute 2009 IECC Table 402.1.1 for 2015 IECC Table R402.1.2 and renumber Table R402.1.2.
SPS 363.5402(2) (2)Equivalent u-factors. Substitute 2009 IECC Table 402.1.3 for 2015 IECC Table R402.1.4 and renumber Table R402.1.4.
SPS 363.5402(3) (3)Air leakage. Substitute the wording from 2009 IECC sections 402.4.1, 402.4.2, 402.4.2.1, and 402.4.2.2 for IECC sections R402.4, R402.4.1, R402.4.1.1, and R402.4.1.2.
SPS 363.5402(4) (4)Air barrier and insulation inspection component table. Substitute 2009 IECC Table 402.4.2 for 2015 IECC Table R402.4.1.1.
SPS 363.5402 History History: CR 16-094: cr., Register April 2018 No. 748 eff. 5-1-18.
SPS 363.5403 SPS 363.5403Systems.
SPS 363.5403(1)(1) Electrical power and lighting. This is a department rule in addition to the requirements in IECC section R403: In residential buildings having individual dwelling units, provisions shall be made to determine the electrical energy consumed by each tenant by separately metering individual dwelling units.
SPS 363.5403(2) (2)Ducts. Substitute the following wording for the requirements in IECC section R403.3.2: All ducts, air handlers, and filter boxes shall be sealed. Joints and seams shall comply with IMC section 603.9.
SPS 363.5403(3) (3)Protection of piping insulation in residential buildings. The requirements in IECC section R403.4.1 are not included as part of chs. SPS 361 to 366.
SPS 363.5403 History History: CR 06-120: cr. Register February 2008 No. 626, eff. 3-1-08; CR 10-103: r. and recr. (2), r. (3) Register August 2011 No. 668, eff. 9-1-11; CR 16-094: renum. 363.5403 from 363.0403 and am., cr. (3), Register April 2018 No. 748 eff. 5-1-18.
SPS 363.5404 SPS 363.5404Lighting equipment. Substitute the following wording for the requirements, but not the exception, in IECC section R404.1: A minimum of 50 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps.
SPS 363.5404 History History: CR 16-094: cr., Register April 2018 No. 748 eff. 5-1-18.
SPS 363.5405 SPS 363.5405Calculation software tools. This is a department informational note to be used under IECC section R405.6: Note: The federal Department of Energy has developed REScheckTM, a computer program that may be used in demonstrating compliance for a residential building which has no more than 3 stories above grade and has 3 or more dwelling units. The REScheck program may be downloaded at http://www.energycodes.gov. The most recent version of REScheck shall be used to determine code compliance. When using the program, the applicable code must be defined as the “2015 IECC.”
SPS 363.5405 History History: CR 06-120: cr. Register February 2008 No. 626, eff. 3-1-08; CR 10-103: renum. from Comm 63.0404 and am. Register August 2011 No. 668, eff. 9-1-11; CR 16-094: renum. 363.5405 from 363.0405 and am., Register April 2018 No. 748 eff. 5-1-18.
SPS 363.5502 SPS 363.5502Additions.
SPS 363.5502(1)(1) Insulation and fenestration requirements by component. Substitute 2009 IECC Table 402.1.1 for 2015 IECC Table R402.1.2 and renumber Table R402.1.2.
SPS 363.5502(2) (2)Equivalent u-factors. Substitute 2009 IECC Table 402.1.3 for 2015 IECC Table R402.1.4 and renumber Table R402.1.4.
SPS 363.5502(3) (3)Air leakage. Substitute the wording from 2009 IECC sections 402.4.1, 402.4.2, 402.4.2.1, and 402.4.2.2 for IECC sections R402.4.0, R402.4.1, R402.4.1.1, and R402.4.1.2.
SPS 363.5502(4) (4)Air barrier and insulation inspection component table. Substitute 2009 IECC Table 402.4.2 for 2015 IECC Table R402.4.1.1.
SPS 363.5502 History History: CR 16-094: cr., Register April 2018 No. 748 eff. 5-1-18.
SPS 363.5503 SPS 363.5503Alterations.
SPS 363.5503(1)(1) Insulation and fenestration requirements by component. Substitute 2009 IECC Table 402.1.1 for 2015 IECC Table R402.1.2 and renumber Table R402.1.2.
SPS 363.5503(2) (2)Equivalent u-factors. Substitute 2009 IECC Table 402.1.3 for 2015 IECC Table R402.1.4 and renumber Table R402.1.4.
SPS 363.5503(3) (3)Air leakage. Substitute the wording from 2009 IECC sections 402.4.1, 402.4.2, 402.4.2.1, and 402.4.2.2 for IECC sections R402.4.0, R402.4.1, R402.4.1.1, and R402.4.1.2.
SPS 363.5503(4) (4)Air barrier and insulation inspection component table. Substitute 2009 IECC Table 402.4.2 for 2015 IECC Table R402.4.1.1.
SPS 363.5503 History History: CR 16-094: cr., Register April 2018 No. 748 eff. 5-1-18.
SPS 363.5600 SPS 363.5600Referenced standards. This is a department rule in addition to the requirements in IECC chapter 6[RE]: The following standards are incorporated by reference into chs. SPS 361 to 366:
SPS 363.5600(1) (1) ASTM C177-13, Test method for steady-state heat flux measurements and thermal transmission properties by means of the guarded-hot-plate apparatus.
SPS 363.5600(2) (2) ASTM C335/335M-10, Test method for steady state heat transfer properties of horizontal pipe insulation.
SPS 363.5600(3) (3) ASTM C518-15, Test method for steady-state thermal transmission properties by means of the heat flow meter apparatus.
SPS 363.5600(4) (4) ASTM C1363-11, Test method for thermal performance of materials and envelope assemblies by means of a hot box apparatus.
SPS 363.5600 Note Note: ASTM standards may be purchased at www.astm.org or from the American Society for Testing and Materials International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959.
SPS 363.5600 Note Copies of the standards adopted under this section are on file in the offices of the department and the legislative reference bureau.
SPS 363.5600 History History: CR 16-094: cr., Register April 2018 No. 748 eff. 5-1-18; correction in (intro.) made under s. 13.92 (4) (b) 7., Stats., Register April 2018 No. 748.
Loading...
Loading...
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date the chapter was last published.