SPS 363.0407(2)
(2) Total energy performance. This is a department informational note to be used under IECC section C407: Note: Use of IECC section C407 requires the total building energy cost to be equal to or less than the standard reference design building, as required under IECC section C401.2 item 3. The 2015 IECC or ASHRAE 90.1-2013 options shall be selected.
SPS 363.0407(3)
(3) COMcheck. This is a department informational note to be used under IECC section C407: Note: COMcheck is a computer program that may be used only for determining building envelope or lighting compliance. The COMcheck computer program may be downloaded at:http:/
www.energycodes.gov/. The most recent version of COMcheck shall be used to demonstrate code compliance. The 2015 IECC or ASHRAE 90.1-2013 options shall be selected.
SPS 363.0407 History
History: CR 16-094: renum. 363.0506 (title) to 363.0407 (title), renum. 363.0506 to 363.0407 (3) and am., cr. (1), (2),
Register April 2018 No. 748 eff. 5-1-18;
correction in (2) made under s. 35.17, Stats, Register July 2018 No. 751.
SPS 363.0408
SPS 363.0408 System commissioning. The requirements of IECC section C408 are not included as part of
chs. SPS 361 to
366.
SPS 363.0408 History
History: CR 16-094: cr.
Register April 2018 No. 748 eff. 5-1-18.
SPS 363.0502(1)(1)
Opaque assemblies. Substitute 2009 IECC Table 502.2 (1)
for 2015 IECC Table C402.1.3 and renumber Table C402.1.3.
SPS 363.0502(2)
(2) Opaque element maximum u-factors. Substitute 2009 IECC Table 502.1.2 for 2015 IECC Table C402.1.4 and renumber Table C402.1.4.
SPS 363.0502(3)
(3) Air leakage. Substitute the wording from 2009 IECC sections 402.4.1, 402.4.2, 402.4.2.1 and 402.4.2.2 for IECC
section C402.5, C402.5.1, C402.5.1.1, and C402.5.2.
SPS 363.0502(4)
(4) Air barrier and insulation inspection component table. Substitute 2009 IECC Table 402.4.2 for IECC Table C402.5.1.2, C402.5.1.2.1, and C402.5.1.2.2.
SPS 363.0502 History
History: CR 16-094: cr.
Register April 2018 No. 748 eff. 5-1-18.
SPS 363.0503(1)(1)
Opaque assemblies. Substitute 2009 IECC Table 502.2 (1)
for 2015 IECC Table C402.1.3 and renumber Table C402.1.3.
SPS 363.0503 Note
Note: Use of the ASHRAE Handbook of Fundamentals standard in effect at the time of publication of the 2015 IECC constitutes compliance with this section.
SPS 363.0503(2)
(2) Opaque element maximum u-factors. Substitute 2009 IECC Table 502.1.2 for 2015 IECC Table C402.1.4 and renumber Table C402.1.4.
SPS 363.0503(3)
(3) Air leakage. Substitute the wording from 2009 IECC sections 402.4.1, 402.4.2, 402.4.2.1 and 402.4.2.2 for IECC
section C402.5, C402.5.1, C402.5.1.1, and C402.5.2.
SPS 363.0503(4)
(4) Air barrier and insulation inspection component table. Substitute 2009 IECC Table 402.4.2 for IECC Table C402.5.1.2, C402.5.1.2.1, and C402.5.1.2.2.
SPS 363.0503(5)
(5) Lighting alterations. Substitute the following wording for the exception in IECC
section C503.6: Alterations that replace less than 50 percent of the luminaires in a space, provided that such alterations do not increase the installed interior lighting power.
SPS 363.0503 History
History: CR 16-094: cr.,
Register April 2018 No. 748 eff. 5-1-18.
SPS 363.0600
SPS 363.0600
Referenced standards. This is a department rule in addition to the requirements in IECC chapter 6[CE]: The following standards are incorporated by reference into
chs. SPS 361 to
366:
SPS 363.0600(1)
(1) ASTM C177-13, Test method for steady-state heat flux measurements and thermal transmission properties by means of the guarded-hot-plate apparatus.
SPS 363.0600(2)
(2) ASTM C335/335M-10, Test method for steady state heat transfer properties of horizontal pipe insulation.
SPS 363.0600(3)
(3) ASTM 518-15, Test method for steady-state thermal transmission properties by means of the heat flow meter apparatus.
SPS 363.0600(4)
(4) ASTM C1363-11, Test method for thermal performance of materials and envelope assemblies by means of a hot box apparatus.
SPS 363.0600(5)
(5) National Concrete Masonry Association (NCMA) Evaluation Procedures of Integrally Insulated Concrete Masonry Walls, January 1, 1999.
SPS 363.0600 Note
Note: ASTM standards may be purchased at
www.astm.org or from the American Society for Testing and Materials International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959.
SPS 363.0600 Note
NCMA Evaluation Procedures may be purchased at ncma.org or from the National Concrete Masonry Association, 13750 Sunrise Valley Drive, Herndon, VA 20171.
SPS 363.0600 Note
Copies of the standards adopted under this section are on file in the offices of the department and the legislative reference bureau.
SPS 363.0600 History
History: CR 06-120: cr.
Register February 2008 No. 626, eff. 3-1-08;
CR 16-094: renum. 363.0900 to 363.0600 and am. (intro.), (1) to (4),
Register April 2018 No. 748 eff. 5-1-18.
SPS 363.5101
SPS 363.5101 Administration and enforcement. The requirements in IECC sections R101 and R103 to R109 are not included as part of this chapter.
SPS 363.5101 History
History: CR 16-094: cr.,
Register April 2018 No. 748 eff. 5-1-18.
SPS 363.5202
SPS 363.5202 Substitutions. Substitute the following definition for the corresponding definition listed in IECC section R202: “Approved” has the meaning given in
s. SPS 362.0202 (2) (a).
SPS 363.5202 History
History: CR 16-094: cr.,
Register April 2018 No. 748 eff. 5-1-18.
SPS 363.5302
SPS 363.5302 Exterior design conditions. These are department rules in addition to the requirements in IECC section R302: The exterior design temperatures used for heating and cooling load calculations shall be as specified in SPS Table 363.0302.
SPS 363.5302 History
History: CR 16-094: cr.,
Register April 2018 No. 748 eff. 5-1-18.
SPS 363.5303
SPS 363.5303 Materials, systems, and equipment. These are department rules in addition to the requirements in IECC section R303:
SPS 363.5303(1)
(1) General. Except as specified in
sub. (2), when available, information on thermal properties, performance of building envelope sections, and components and heat transfer shall be obtained from ASHRAE Handbook of Fundamentals.
SPS 363.5303 Note
Note: Use of the ASHRAE Handbook of Fundamentals standard in effect at the time of publication of the 2015 IECC constitutes compliance with this section.
SPS 363.5303(2)(a)(a) When the information is not available from ASHRAE Handbook of Fundamentals, the data shall be obtained from laboratory or field-test measurements. If laboratory or field test measurements are used for envelope heat transmission, the measurements shall be obtained using one of the following test methods:
SPS 363.5303(2)(b)
(b) For foam plastic insulation that incorporates a substance other than air as the insulating medium, laboratory or field tests shall be conducted on representative samples that have been aged for the equivalent of 5 years or until the R-Value has stabilized to determine thermal properties or performance. The tests shall be conducted by an independent third party.
SPS 363.5303(2)(c)
(c) Integrally insulated concrete masonry systems within the scope of the National Concrete Masonry Association (NCMA) shall be evaluated for the thermal performance of the masonry or concrete units in accordance with one of the following:
SPS 363.5303(2)(c)1.
1. NCMA Evaluation Procedures for the Integrally-Insulated Concrete Masonry Walls.
SPS 363.5303(2)(d)
(d) All other concrete or masonry units not within the scope of the NCMA Evaluation Procedures shall comply with one of the following methods for determining the thermal performance of the assembly or system:
SPS 363.5303 History
History: CR 16-094: cr.,
Register April 2018 No. 748 eff. 5-1-18.
SPS 363.5401
SPS 363.5401
Certificate. The requirements in IECC
section R401.3 are not included as part of
chs. SPS 361 to
366.
SPS 363.5401 History
History: CR 06-120: cr.
Register February 2008 No. 626, eff. 3-1-08;
CR 16-094: renum. 363.5401 from 363.0401 and am.,
Register April 2018 No. 748 eff. 5-1-18.
SPS 363.5402(1)(1)
Insulation and fenestration requirements by component. Substitute 2009 IECC Table 402.1.1 for 2015 IECC Table R402.1.2 and renumber Table R402.1.2.
SPS 363.5402(2)
(2) Equivalent u-factors. Substitute 2009 IECC Table 402.1.3 for 2015 IECC Table R402.1.4 and renumber Table R402.1.4.
SPS 363.5402(3)
(3) Air leakage. Substitute the wording from 2009 IECC sections 402.4.1, 402.4.2, 402.4.2.1, and 402.4.2.2 for IECC
sections R402.4, R402.4.1, R402.4.1.1, and R402.4.1.2.
SPS 363.5402(4)
(4) Air barrier and insulation inspection component table. Substitute 2009 IECC Table 402.4.2 for 2015 IECC Table R402.4.1.1.
SPS 363.5402 History
History: CR 16-094: cr.,
Register April 2018 No. 748 eff. 5-1-18.
SPS 363.5403(1)(1)
Electrical power and lighting. This is a department rule in addition to the requirements in IECC section R403: In residential buildings having individual dwelling units, provisions shall be made to determine the electrical energy consumed by each tenant by separately metering individual dwelling units.
SPS 363.5403(2)
(2) Ducts. Substitute the following wording for the requirements in IECC
section R403.3.2: All ducts, air handlers, and filter boxes shall be sealed. Joints and seams shall comply with IMC section 603.9.
SPS 363.5403(3)
(3) Protection of piping insulation in residential buildings. The requirements in IECC
section R403.4.1 are not included as part of
chs. SPS 361 to
366.
SPS 363.5403 History
History: CR 06-120: cr.
Register February 2008 No. 626, eff. 3-1-08;
CR 10-103: r. and recr. (2), r. (3)
Register August 2011 No. 668, eff. 9-1-11;
CR 16-094: renum. 363.5403 from 363.0403 and am., cr. (3),
Register April 2018 No. 748 eff. 5-1-18.
SPS 363.5404
SPS 363.5404 Lighting equipment. Substitute the following wording for the requirements, but not the exception, in IECC
section R404.1: A minimum of 50 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps.
SPS 363.5404 History
History: CR 16-094: cr., Register April 2018 No. 748 eff. 5-1-18. SPS 363.5405
SPS 363.5405 Calculation software tools. This is a department informational note to be used under IECC
section R405.6: Note: The federal Department of Energy has developed REScheck
TM, a computer program that may be used in demonstrating compliance for a residential building which has no more than 3 stories above grade and has 3 or more dwelling units. The REScheck program may be downloaded at
http://www.energycodes.gov. The most recent version of REScheck shall be used to determine code compliance. When using the program, the applicable code must be defined as the “2015 IECC.”
SPS 363.5405 History
History: CR 06-120: cr.
Register February 2008 No. 626, eff. 3-1-08;
CR 10-103: renum. from Comm 63.0404 and am.
Register August 2011 No. 668, eff. 9-1-11;
CR 16-094: renum. 363.5405 from 363.0405 and am.,
Register April 2018 No. 748 eff. 5-1-18.
SPS 363.5502(1)(1)
Insulation and fenestration requirements by component. Substitute 2009 IECC Table 402.1.1 for 2015 IECC Table R402.1.2 and renumber Table R402.1.2.
SPS 363.5502(2)
(2) Equivalent u-factors. Substitute 2009 IECC Table 402.1.3 for 2015 IECC Table R402.1.4 and renumber Table R402.1.4.
SPS 363.5502(3)
(3) Air leakage. Substitute the wording from 2009 IECC sections 402.4.1, 402.4.2, 402.4.2.1, and 402.4.2.2 for IECC
sections R402.4.0, R402.4.1, R402.4.1.1, and R402.4.1.2.
SPS 363.5502(4)
(4) Air barrier and insulation inspection component table. Substitute 2009 IECC Table 402.4.2 for 2015 IECC Table R402.4.1.1.
SPS 363.5502 History
History: CR 16-094: cr.,
Register April 2018 No. 748 eff. 5-1-18.
SPS 363.5503(1)(1)
Insulation and fenestration requirements by component. Substitute 2009 IECC Table 402.1.1 for 2015 IECC Table R402.1.2 and renumber Table R402.1.2.
SPS 363.5503(2)
(2) Equivalent u-factors. Substitute 2009 IECC Table 402.1.3 for 2015 IECC Table R402.1.4 and renumber Table R402.1.4.
SPS 363.5503(3)
(3) Air leakage. Substitute the wording from 2009 IECC sections 402.4.1, 402.4.2, 402.4.2.1, and 402.4.2.2 for IECC
sections R402.4.0, R402.4.1, R402.4.1.1, and R402.4.1.2.
SPS 363.5503(4)
(4) Air barrier and insulation inspection component table. Substitute 2009 IECC Table 402.4.2 for 2015 IECC Table R402.4.1.1.
SPS 363.5503 History
History: CR 16-094: cr.,
Register April 2018 No. 748 eff. 5-1-18.
SPS 363.5600
SPS 363.5600 Referenced standards. This is a department rule in addition to the requirements in IECC chapter 6[RE]: The following standards are incorporated by reference into chs.
SPS 361 to
366:
SPS 363.5600(1)
(1) ASTM C177-13, Test method for steady-state heat flux measurements and thermal transmission properties by means of the guarded-hot-plate apparatus.
SPS 363.5600(2)
(2) ASTM C335/335M-10, Test method for steady state heat transfer properties of horizontal pipe insulation.
SPS 363.5600(3)
(3) ASTM C518-15, Test method for steady-state thermal transmission properties by means of the heat flow meter apparatus.
SPS 363.5600(4)
(4) ASTM C1363-11, Test method for thermal performance of materials and envelope assemblies by means of a hot box apparatus.
SPS 363.5600 Note
Note: ASTM standards may be purchased at
www.astm.org or from the American Society for Testing and Materials International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959.
SPS 363.5600 Note
Copies of the standards adopted under this section are on file in the offices of the department and the legislative reference bureau.