1. The owner of the property possesses a sanitary permit for the installation of a POWTS in accordance with s. SPS 383.21; or
Note: Section SPS 383.21 outlines the procedures for the issuance of sanitary permits. Section 145.19, Stats., mandates that no private sewage system may be installed unless the owner of the property holds a valid sanitary permit.
2. A POWTS of adequate capability and capacity to accommodate the wastewater flow and contaminant load already exists to serve the structure.
Note: See ss. SPS 383.02 and 383.03 concerning the application of current code requirements to existing POWTS.
(c) Construction affecting wastewater flow or contaminant load. 1. A municipality may not issue a building permit to commence construction of any addition or alteration to an existing structure when the proposed construction will modify the design wastewater flow or contaminant load, or both, to an existing POWTS, unless the owner of the property:
a. Possesses a sanitary permit to either modify the existing POWTS or construct a POWTS to accommodate the modification in wastewater flow or contaminant load, or both; or
b. Provides documentation to verify that the existing POWTS is sufficient to accommodate the modification in wastewater flow or contaminant load, or both.
2. For the purpose of this paragraph, a modification in wastewater flow or contaminant load shall be considered to occur:
a. For commercial facilities, public buildings, and places of employment, when there is a proposed change in occupancy of the structure; or the proposed modification affects either the type or number of plumbing appliances, fixtures or devices discharging to the system; and
b. For dwellings, when there is an increase or decrease in the number of bedrooms.
(d) Documentation of existing capabilities. Documentation to verify whether an existing POWTS can accommodate a modification in wastewater flow or contaminant load, or both, shall include at least one of the following:
1. A copy of the plan for the existing POWTS that delineates minimum and maximum performance capabilities and which has been previously approved by the department or the governmental unit.
2. Information on the performance capabilities for the existing POWTS that has been recognized through a product approval under ch. SPS 384.
3. A written investigative report prepared by an architect, engineer, designer of plumbing systems, designer of private sewage systems, master plumber, master plumber-restricted service or certified POWTS inspector analyzing the proposed modification and the performance capabilities of the existing POWTS.
(e) Where the performance capability of the existing POWTS serving a dwelling is not based on the number of bedrooms within the dwelling, information documenting that design condition shall be recorded as a covenant running with the deed for the property.
(f) Setbacks. 1. A municipality may not issue a building permit for construction of any structure or addition to a structure on a site where there exists a POWTS, unless the proposed construction conforms to the applicable setback limitations under s. SPS 383.43 (8) (i).
2. The applicant for a building permit shall provide documentation to the municipality issuing the building permit showing the location and setback distances for the proposed construction relative to all of the following:
a. Existing POWTS treatment components.
b. Existing POWTS holding components.
c. Existing POWTS dispersal components.
Note: A municipality which issues building permits may delegate to the governmental unit responsible for issuing sanitary permits the determination of whether the proposed construction will affect or interfere with an existing POWTS relating to capability or location of the existing POWTS.
UDC Floor & Ceiling Joist and Roof Rafter Span Tables and Design Value Tables
Use the following Span Tables to determine the maximum spans for floor and ceiling joists and roof rafters. These spans are based on:
  Simple, single spans (although the tables may be safely used for continuous two-span floor joists)
  Uniformly distributed loads
  Fully supported members with one edge properly sheathed and nailed
  For floor joists and roof rafters, the top edge shall be properly sheathed and nailed
  Rafters with a minimum 3:12 slope
The criteria for each Span Table is given in the upper left hand corner and is also summarized in the table of Span Tables below. Choose the appropriate Span Table based on the member type and required loading. Select your desired member depth, member spacing and span to determine the minimum Fb value. Note that these tables include recommended deflection criteria. However, for strict code compliance, only the Fb strength requirements must be satisfied. The modulus of elasticity (E) values, would be met for serviceability purposes only.
Note that straight-line interpolation is permitted for intermediate spans and design values. Span is measured from face to face of supports plus one-half of the required bearing of 1.5 on wood or metal and 3 on masonry or concrete at each end. For sloping rafters, the span is measured along the horizontal projection.
Section SPS 321.27 allows reduction of the snow live load for roof slopes greater than 30 degrees (7/12 slope) based on the formula Cs = 1 - (a-30)/40, where “a" is the slope of the roof expressed in degrees. Following is a table of tabulated values for certain roof slopes. - See PDF for table PDF
Use the Design Value tables following the Span Tables to determine the acceptable species and grades to satisfy minimum Fb values obtained from the Span Tables. The Design Value tables assume at least three members spaced no more than 24 on center. Use the Normal Duration column Fb values for joists and the Snow Loading column Fb values for rafters.
See the following examples for further guidance.
Tables are reprinted courtesy of American Forest & Paper Association. - See PDF for table PDF
*Deflection criteria are optional. For roof rafters with drywall on the underside, use the stricter L/240 tables to limit deflection.
Example 1. Floor Joists. Assume a required single span of 12-9, dead load of 10 psf and joists spaced 16 on center. Table F-2 (see following highlighted tables) shows that one solution is a grade of 2x8 having an Fb value of 1255 would allow a span of 12-10 which satisfies the condition. (Note that the recommended E value to limit deflection would be 1,600,000.) Going to the Design Value Tables, we find that as an example, 2x8 Hem Fir grade No.1 has an Fb value of 1310 for normal duration. (It also has an E value of 1,500,000 which does not satisfy the recommended deflection criteria.)
Example 2. Rafters. Assume a horizontal projected span of 13-0, a live load of 40 psf, dead load of 10 psf, a roof slope of 4/12 and rafters spaced 16 on center. Since the slope is shallower than 7/12, there is no allowable reduction of the snow live load. Table R-3 shows that a 2x8 having an Fb value of 1300 would allow a span of 13-1 which satisfies the condition. (Note that the recommended E value to limit deflection would be 1,120,000.) Going to the Design Value Tables, we find that as an example, 2x8 Douglas Fir-Larch grade No.2 has an Fb value of 1390 for snow loading. (It also has an E value of 1,600,000 which satisfies the recommended deflection criteria.)
TABLE F- 2
FLOOR JOISTS WITH L/360 DEFLECTION LIMITS
DESIGN CRITERIA:
Deflection - For 40 psf live load.
Limited to span in inches divided by 360.
Strength - Live load of 40 psf plus dead load
of 10 psf determines the required bending design value.
Joist  
Size   Spacing
(in)   (in)                 Modulus of Elasticity, E, in 1,000,000 psi
    0.8   0.9   1.0   1.1   1.2   1.3   1.4   1.5   1.6   1.7   1.8   1.9   2.0   2.1   2.2   2.3   2.4
  12.0   8- 6   8-10   9- 2   9- 6   9- 9   10- 0   10- 3   10- 6   10- 9   10-11   11- 2   11- 4   11- 7   11- 9   11-11   12- 1   12- 3
  16.0   7- 9   8- 0   8- 4   8- 7   8-10   9- 1   9- 4   9- 6   9- 9   9-11   10- 2   10- 4   10- 6   10- 8   10-10   11- 0   11- 2
2x 6   19.2   7- 3   7- 7   7-10   8- 1   8- 4   8- 7   8- 9   9- 0   9- 2   9- 4   9- 6   9- 8   9-10   10- 0   10- 2   10- 4   10- 6
  24.0   6- 9   7- 0   7- 3   7- 6   7- 9   7-11   8- 2   8- 4   8- 6   8- 8   8-10   9- 0   9- 2   9- 4   9- 6   9- 7   9- 9
  12.0   11- 3   11- 8   12- 1   12- 6   12-10   13- 2   13- 6   13-10   14- 2   14- 5   14- 8   15- 0   15- 3   15- 6   15- 9   15-11   16- 2
  16.0   10- 2   10- 7   11- 0   11- 4   11- 8   12- 0   12- 3   12- 7   12-10   13- 1   13- 4   13- 7   13-10   14- 1   14- 3   14- 6   14- 8
2x 8   19.2   9- 7   10- 0   10- 4   10- 8   11- 0   11- 3   11- 7   11-10   12- 1   12- 4   12- 7   12-10   13- 0   13- 3   13- 5   13- 8   13-10
  24.0   8-11   9- 3   9- 7   9-11   10- 2   10- 6   10- 9   11- 0   11- 3   11- 5   11- 8   11-11   12- 1   12- 3   12- 6   12- 8   12-10
  12.0   14- 4   14-11   15- 5   15-11   16- 5   16-10   17- 3   17- 8   18- 0   18- 5   18- 9   19- 1   19- 5   19- 9   20- 1   20- 4   20- 8
  16.0   13- 0   13- 6   14- 0   14- 6   14-11   15- 3   15- 8   16- 0   16- 5   16- 9   17- 0   17- 4   17- 8   17-11   18- 3   18- 6   18- 9
2x10   19.2   12- 3   12- 9   13- 2   13- 7   14- 0   14- 5   14- 9   15- 1   15- 5   15- 9   16- 0   16- 4   16- 7   16-11   17- 2   17- 5   17- 8
  24.0   11- 4   11-10   12- 3   12- 8   13- 0   13- 4   13- 8   14- 0   14- 4   14- 7   14-11   15- 2   15- 5   15- 8   15-11   16- 2   16- 5
  12.0   17- 5   18- 1   18- 9   19- 4   19-11   20- 6   21- 0   21- 6   21-11   22- 5   22-10   23- 3   23- 7   24- 0   24- 5   24- 9   25- 1
  16.0   15-10   16- 5   17- 0   17- 7   18- 1   18- 7   19- 1   19- 6   19-11   20- 4   20- 9   21- 1   21- 6   21-10   22- 2   22- 6   22-10
2x12   19.2   14-11   15- 6   16- 0   16- 7   17- 0   17- 6   17-11   18- 4   18- 9   19- 2   19- 6   19-10   20- 2   20- 6   20-10   21- 2   21- 6
  24.0   13-10   14- 4   14-11   15- 4   15-10   16- 3   16- 8   17- 0   17- 5   17- 9   18- 1   18- 5   18- 9   19- 1   19- 4   19- 8   19-11
Fb   12.0   718   777   833   888   941   993   1043   1092   1140   1187   1233   1278   1323   1367   1410   1452   1494
Fb   16.0   790   855   917   977   1036   1093   1148   1202   1255   1306   1357   1407   1456   1504   1551   1598   1644
Fb   19.2   840   909   975   1039   1101   1161   1220   1277   1333   1388   1442   1495   1547   1598   1649   1698   1747
Fb   24.0   905   979   1050   1119   1186   1251   1314   1376   1436   1496   1554   1611   1667   1722   1776   1829   1882
Note: The required bending design value, Fb, in pounds per square inch is shown at the bottom of each table and is applicable to all lumber sizes shown. Spans are shown in feet-inches and are limited to 26 and less. Check sources of supply for availability of lumber in lengths greater than 20.
TABLE C-1
CEILING JOISTS WITH L/240 DEFLECTION LIMITS
DESIGN CRITERIA:
Deflection - For 10 psf live load.
Limited to span in inches divided by 240.
Strength - Live Load of 10 psf plus
dead load of 5 psf determines the required fiber stress value.
Joist    
Size   Spacing
(in)   (in)                 Modulus of Elasticity, E, in 1,000,000 psi
    0.8   0.9   1.0   1.1   1.2   1.3   1.4   1.5   1.6   1.7   1.8   1.9   2.0   2.1   2.2   2.3   2.4
  12.0   9-10   10- 3   10- 7   10-11   11- 3   11- 7   11-10   12- 2   12- 5   12- 8   12-11   13- 2   13- 4   13- 7   13- 9   14- 0   14- 2
  16.0   8-11   9- 4   9- 8   9-11   10- 3   10- 6   10- 9   11- 0   11- 3   11- 6   11- 9   11-11   12- 2   12- 4   12- 6   12- 9   12-11
Loading...
Loading...
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date the chapter was last published.