This is the preview version of the Wisconsin State Legislature site.
Please see http://docs.legis.wisconsin.gov for the production version.
16 Surface water systems and groundwater systems under the direct influence of surface water are regulated under Subpart H of 40 CFR part 141. Community and non-transient non-community systems using groundwater under the direct influence of surface water serving 10,000 or more shall comply with DBP MCLs and disinfectant maximum residual disinfectant levels beginning January 1, 2002. All other community and non-transient non-community systems shall meet the MCLs and MRDLs beginning January 1, 2004. Transient non-community systems using groundwater under the direct influence of surface water serving 10,000 or more persons and using chlorine dioxide as a disinfectant or oxidant shall comply with the chlorine dioxide MRDL beginning January 1, 2002. Transient non-community systems using groundwater under the direct influence of surface water serving fewer than 10,000 persons and public water systems using only groundwater not under the direct influence of surface water and using chlorine dioxide as a disinfectant or oxidant shall comply with the chlorine dioxide MRDL beginning January 1, 2004.
17 The MCL for total trihalomethanes is the sum of the concentrations of the individual trihalomethanes.
18 The MCL for haloacetic acids is the sum of the concentrations of the individual haloacetic acids.
19 MRDLG — Maximum residual disinfectant level goal.
20 MRDL — Maximum residual disinfectant level.
Appendix C to Subchapter VII
List of Acronyms Used in Public Notification Regulation
CCR   Consumer Confidence Report
CWS   Community Water System
DBP   Disinfection Byproduct
EPA   Environmental Protection Agency
HPC   Heterotrophic Plate Count
IESWTR   Interim Enhanced Surface Water Treatment Rule
IOC   Inorganic Chemical
LCR   Lead and Copper Rule
MCL   Maximum Contaminant Level
MCLG   Maximum Contaminant Level Goal
MRDL   Maximum Residual Disinfectant Level
MRDLG   Maximum Residual Disinfectant Level Goal
NCWS   Non-Community Water System
NPDWR   National Primary Drinking Water Regulation
NTNCWS   Non-Transient Non-Community Water System
NTU   Nephelometric Turbidity Unit
OGWDW   Office of Groundwater and Drinking Water
OW   Office of Water
PN   Public Notification
PWS   Public Water System
SDWA   Safe Drinking Water Act
SMCL   Secondary Maximum Contaminant Level
SOC   Synthetic Organic Chemical
SWTR   Surface Water Treatment Rule
TCR   Total Coliform Rule
TT   Treatment Technique
TWS   Transient Non-Community Water System
VOC   Volatile Organic Chemical
Loading...
Loading...
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date the chapter was last published.