NR 716.11 Note
Note: The use of piezometers may not be appropriate for all situations, including at the source area, or where a documented upward gradient exists downgradient of a source area.
NR 716.11(5)(g)
(g) The presence and concentration of vapors sub-slab, when investigation of soil, soil gas or groundwater indicates that vapors may migrate to the foundation of an occupied building, taking into account the biodegradability of vapors, preferential pathways of vapor movement, or other physical or chemical factors affecting vapor movement into occupied buildings.
NR 716.11(5)(h)
(h) The presence and concentration of vapors in indoor air, when it is necessary to determine the impact on an occupied structure considering applicable attenuation factors, land use, building size and other site-specific factors that affect exposure to vapor.
NR 716.11 Note
Note: Indoor air samples are expected to be collected and analyzed in most cases where vapor migration into an occupied residential setting is likely. A residential setting may include single or multiple family housing, and educational, childcare, and elder care facilities. Sampling and analysis is conducted to determine levels of the contaminants of concern. Indoor air sampling is not recommended in locations where the contaminant of concern is currently used in commercial or industrial operations.
NR 716.11(6)
(6) Responsible parties shall manage investigative wastes in a manner that will not pose a threat to public health, safety, or welfare or the environment, and which is consistent with state and federal regulations.
NR 716.11(7)
(7) Responsible parties shall label all drums containing investigative wastes, including drill cuttings and purge water, with the Bureau for Remediation and Redevelopment Tracking System activity number for the site, the site name, boring or well number, initial date of collection, and the contents.
NR 716.11 History
History: Cr.
Register, April, 1994, No. 460, eff. 5-1-94; am. (3) (b),
Register, April, 1995, No. 472, eff. 5-1-95; emerg. cr. (3) (c), am. (5) (a), eff. 5-18-00; cr. (3) (c), am. (5) (a),
Register, January, 2001, No. 541, eff. 2-1-01;
CR 12-023: cr. (2g), (2r), am. (3) (c), cr. (3) (d), (5) (e) to (h), (7)
Register October No. 694, eff. 11-1-13.
NR 716.13
NR 716.13 Sampling and analysis requirements. NR 716.13(1)(1)
Responsible parties shall use laboratory analyses of environmental media samples which are collected, handled and analyzed in compliance with subs.
(2) to
(17) to confirm the nature and extent and evaluate the impacts of contamination, if a field investigation is required under s.
NR 716.11 (1). Analytical methods used shall be suitable for the matrix, type of analyte, expected level of analyte, regulatory limit, and potential interferences in the samples to be tested.
NR 716.13(2)
(2) All chemical and physical analyses for which accreditation is available under ch.
NR 149 shall be conducted by a laboratory accredited under ch.
NR 149.
NR 716.13(3)
(3) Responsible parties may use non–laboratory methods of sample analysis, including field screening with a photoionization detector or flame ionization detector, analysis with a field gas chromatograph, geophysical or downhole probe surveying, non–certified mobile laboratory analysis, immunoassays and other appropriate methods, to supplement the information derived from laboratory analysis of samples. If non–laboratory methods are used at a location from which a laboratory sample is collected, responsible parties shall use separate samples for the non–laboratory and the laboratory analyses, unless the target compound is not subject to loss or alteration through sample handling.
NR 716.13(4)
(4) All soil samples obtained during the field investigation for the purpose of defining the degree and extent of the contamination shall be discrete, not composite, samples, unless the department explicitly approves in advance composite sampling for a specific site situation.
NR 716.13(5)
(5) Maximum holding times for soils shall be in accordance with the sampling method, sample storage container, and analytical methods used.
NR 716.13(6)
(6) Responsible parties shall provide for the following quality control and quality assurance procedures, at a minimum, when collecting samples for laboratory analysis for a field investigation conducted under this chapter:
NR 716.13(6)(a)
(a) Chain of custody shall be documented from the time of sample collection to the receipt of the sample by the analytical laboratory. Chain of custody documentation shall be in compliance with ch.
NR 149, and shall be submitted to the department with the sample results.
NR 716.13(6)(b)
(b) For soil samples, one temperature blank for every shipping container of samples that require cooling for preservation, unless samples are received by the laboratory on ice, unless another temperature is required by the analytical method used.
NR 716.13(6)(c)2.
2. One equipment blank for every 10 or less samples, unless dedicated sampling equipment is used to prevent cross-contamination.
NR 716.13(6)(c)3.
3. One trip blank for each shipping container that contained volatile samples.
NR 716.13(6)(c)4.
4. One temperature blank for every shipping container of samples that require cooling for preservation, unless samples are shipped on ice.
NR 716.13(6)(d)
(d) Decontamination of all sampling instruments between each sampling event, unless dedicated or disposable sampling devices are used in a manner that prevents cross contamination or other unintended contamination of samples.
NR 716.13(7)
(7) Responsible parties shall ensure that the following items are documented during the field investigation and are made available to the department upon request:
NR 716.13(7)(a)
(a) Procedures for sampling and all other routine activities associated with the site investigation.
NR 716.13(7)(b)
(b) A log of all routine and non-routine maintenance and calibrations performed on all instruments used during the field investigation.
NR 716.13(7)(c)
(c) Field notes describing in detail the sequence of activities that took place during the field investigation.
NR 716.13(8)
(8) For soil and water samples, the reporting limit for volatile organic compound analysis and petroleum volatile organic compound analysis shall be the method detection limit for the analytical method used. If the results are less than the method detection limit, the results shall be reported as less than the method detection limit, rather than no detect. Qualifiers used for the data shall also be reported.
NR 716.13 Note
Note: Section
NR 140.16 (2) (c) requires that the analytical method selected meet one of the following criteria: 1) has a limit of detection and limit of quantitation below the preventive action limit or 2) produces the lowest available limit of detection and limit of quantitation if the limit of detection and limit of quantitation are above the preventive action limit. In addition, s.
NR 140.14 (3) specifies whether a standard has been attained or exceeded if a preventive action limit or enforcement standard is equal to or less than the limit of quantitation.
NR 716.13 Note
Note: Chapter
NR 720 specifies whether a soil cleanup standard has been exceeded if the standard is at or below the limit of quantitation.
NR 716.13(9)
(9) Responsible parties shall ensure that drinking water samples are collected, handled and analyzed according to the procedures specified in ch.
NR 809.
NR 716.13(10)
(10) Responsible parties shall ensure that groundwater samples are collected and handled according to the procedures specified in s.
NR 140.16 (1), unless the department approves the use of an alternative procedure. The department may approve the use of an alternative procedure from one of the authoritative sources listed in ch.
NR 149 Appendix III, or an alternate test procedure approved by the U.S. EPA, or, if the department determines that an appropriate procedure is not available, from another source. Alternative procedures may include the most recent published method, or an older published version deemed acceptable by the department on the basis of the objectives of the data collection. Responsible parties shall select an analytical method that is suitable for the matrix, type of analyte, expected level of analyte, regulatory limit, and potential interferences in the sample to be tested.
NR 716.13 Note
Note: Examples of suitable analytical methods for VOCs and PVOCs in groundwater include EPA methods 5030B/8260B, EPA Method 8310 or 8270C-SIM or 8270D-SIM for PAHs, EPA method 3510C/8082A or 3520C/8082A for PCBs, EPA Method 3020A/6020A or 3010A/6020A for Pb, EPA Method 3020A/6020A for Cd, and EPA Method 1664 (Revision B) for oil and grease.
NR 716.13(11)
(11) Soil samples collected for analysis of volatile organic compounds for compliance with chs.
NR 700 to
754 shall be preserved immediately after collection to minimize volatilization of contaminants from the sample to the greatest extent possible. Preservation techniques used shall be according to the analytical method to be used. Sampling techniques shall be used that minimize volatilization from the sample. Extraction techniques shall be according to the analytical method selected. Analytical methods used shall be suitable for the matrix, type of analyte, expected level of analyte, regulatory limit, and potential interferences in the samples to be tested.
NR 716.13 Note
Note: Suitable preservation, extraction and analytical methods include those found in method SW 5035A in “Test Methods for Evaluating Solid Waste (SW-846)," and in the “Modified GRO, Method for Determining Gasoline Range Organics" (GRO for screening purposes). Other techniques may be found in the List of Authoritative Sources, ch.
NR 149 Appendix III.
NR 716.13(12)
(12) Responsible parties shall ensure that other samples taken for analysis are collected, handled and analyzed according to the procedures specified in “SW–846: Test Methods for Evaluating Solid Waste", “The Third Edition of SW 846, as amended by Final Updates I, II, IIA, IIB, III, IIIA, IIIB, and IV," published by the U.S. EPA, unless the department approves the use of an alternative procedure. The department may approve the use of an alternative procedure from one of the authoritative sources listed in ch.
NR 149 Appendix III, an alternate test procedure approved by the U.S. EPA, or, if the department determines that an appropriate procedure is neither available from “SW–846: Test Methods for Evaluating Solid Waste" nor from one of the authoritative sources listed in ch.
NR 149 Appendix III, from another source.
NR 716.13 Note
Note: Copies of “SW–846: Test Methods for Evaluating Solid Waste" are available for inspection at the offices of the department of natural resources, the secretary of state, and the revisor of statutes. Copies may be obtained from the Government Printing Office, Room 190, Federal Building, 517 East Wisconsin Avenue, Milwaukee, WI 53202 and may be accessed at the following web site:
http://www.epa.gov/epaoswer/hazwaste/test/main.htm. Other suitable procedures may include revised SW-846 methods found at the EPA Office of Solid Waste Methods Web Site,
NR 716.13(13)
(13) Responsible parties shall collect samples and provide an analysis for the geochemical indicators and parameters, where natural attenuation is potentially a remedy or part of a remedy. These may include dissolved oxygen, nitrate, dissolved manganese, total and ferrous iron, sulfate and methane, alkalinity, oxidation reduction potential, pH, temperature, and conductivity.
NR 716.13(14)(a)(a) Responsible parties shall inspect monitoring wells installed for field investigations conducted under this chapter at least annually to verify the integrity of the well labels, lock and seal, and to determine whether the wells are providing a conduit to the subsurface, and shall take action to repair or abandon the well if necessary in accordance with ch.
NR 141.
NR 716.13(14)(b)
(b) Flush mounted wells shall include a magnet placed in the void between the cover and the annular space seal. In cases where flush-mounted wells are not used, wells installed in areas potentially subject to damage from vehicle traffic shall include appropriate protective traffic posts next to the well.
NR 716.13 Note
Note: Traffic posts can vary in design. Normally, properly anchored concrete filled metal posts should be used to protect wells. The magnet may aid in locating wells for abandonment.
NR 716.13(15)
(15) Responsible parties shall measure and record to the nearest 0.01 foot the static water level elevation in each groundwater monitoring well prior to obtaining a groundwater sample from the well. The measurement point shall be the top of the well casing and shall be identified on the well itself if the top of the casing is not level.
NR 716.13 Note
Note: Section
NR 141.065 (2) requires that the top of the well casing be referenced to the nearest benchmark for the national geodetic survey datum to an accuracy of 0.01 feet.
NR 716.13(16)
(16) Where site investigation data or other information indicate it is appropriate, or when directed to do so by the department, responsible parties shall make a good faith effort to sample public or private water supply wells as part of a regular monitoring program or to determine the extent of groundwater contamination, or both. Private and public water supply wells to be sampled shall include:
NR 716.13(16)(a)
(a) Those wells that are known or suspected to be affected by the groundwater contamination.
NR 716.13(16)(b)
(b) Other wells that the department determines have the potential to be affected by the groundwater contamination.
NR 716.13(17)
(17) If the responsible parties are unable to sample a public or private well because the property owner refuses access, the responsible parties shall notify the department within 30 days of the refusal, and shall document in writing the efforts undertaken to gain access when requested by the department.
NR 716.13 History
History: Cr.
Register, April, 1994, No. 460, eff. 5-1-94;
CR 12-023: r. and recr.
Register October No. 694, eff. 11-1-13.
NR 716.14
NR 716.14 Sample results notification requirements. NR 716.14(1)(1)
Samples from water supply wells. Responsible parties shall report all water supply well sampling results to the department and to the well owner, and occupant as applicable, within 10 business days after receiving the sampling results. The report to the department shall include the Wisconsin unique well number for drinking water wells, a preliminary analysis of the cause and significance of any contaminant concentrations observed in the samples and an identification of any substances that attain or exceed ch.
NR 140 preventive action limits, as well as any other substances observed in the samples for which there are no ch.
NR 140 groundwater quality standards. The responsible party shall notify both the remediation and redevelopment project manager and the regional drinking and groundwater specialist or water supply engineer of all water supply well sample results.
NR 716.14 Note
Note: The department will provide information to well owners of the results of sampling in accordance with manual code 4822.1.
NR 716.14(2)
(2) Samples from other media. Responsible parties shall report all sampling results other than those for water supply wells, to the department and to the property owner, and occupants as appropriate, of the property from which the samples were collected, including the source property owner if the person conducting the investigation is not the property owner, within 10 business days of receiving the sample results.
NR 716.14(2)(a)
(a) The report to the department shall include a preliminary analysis of the cause and significance of any contaminant concentrations observed in the sample, a list of names and addresses of those receiving a sampling notification, and the date of the sampling event and mailing.
NR 716.14(2)(b)
(b) The written notification to an affected property owner, and occupant as appropriate, shall include information about how additional information may be obtained, in accordance with s.
NR 714.05 (5). The department may waive the notification of occupants in limited situations, upon request.
NR 716.14(2)(c)
(c) In addition, the notification to the property owners, and occupants as appropriate, shall include all the following information, in a letter or using a form provided by the department:
NR 716.14(2)(c)5.
5. Reason for sampling, which may include routine sampling, and sampling to determine an immediate health concern, including the ingestion, inhalation, and dermal contact pathways.
NR 716.14(2)(c)7.
7. Sample type, which may include groundwater, soil, sediment, soil vapor, outdoor or ambient air, and indoor air.
NR 716.14(2)(c)9.
9. Collection date, specific contaminant levels per location, and whether the sample results attain or exceed state standards. A data table shall be used when multiple sample results are included.
NR 716.14(2)(c)10.
10. A copy of the results from the laboratory attached to the notification.
NR 716.14 Note
Note: Notification of sampling results is intended for those samples taken from a property including results from both routine and long-term monitoring and those of a more immediate health or welfare concern to a property owner, or occupant as appropriate. Examples of sampling to determine the presence of an immediate public health or welfare concern are from potable wells, indoor air, surface soil, and soil vapor beneath an occupied structure. "All sampling results" means the results that show detections of contaminants as well as those that do not show detections.
NR 716.14 Note
Note: Assistance in evaluating the impact and meaning of the sample results may be requested of the department project manager or drinking water staff, or from staff with the Division of Public Health, with the Department of Health Services.
NR 716.14 Note
Note: The notification to occupants is not intended for situations where there are multiple units or a frequent change in occupancy.
NR 716.14(3)
(3) The department may approve of a different notification schedule on a case-by-case basis.
NR 716.14 Note
Note: In cases where routine monitoring is conducted, and where results are not expected to be of immediate health or welfare concern, the department may consider other schedules, such as quarterly or with the semi-annual status reports to be sufficient.
NR 716.14(4)
(4) The responsible party shall take the actions necessary to ensure any new occupants are also informed of the pertinent information required under s.
NR 716.14 (2) (c).
NR 716.14 History
History: CR 12-023: cr.
Register October No. 694, eff. 11-1-13.
NR 716.15
NR 716.15 Site investigation report. NR 716.15(1)(a)(a)
Timeline. Unless otherwise approved by the department, responsible parties shall submit a site investigation report to the department within 60 days after completion of the field investigation and receipt of laboratory data.
NR 716.15(1)(b)
(b)
Number of copies. One paper copy and one electronic copy of the report shall be submitted to the department, unless otherwise directed by the department, in accordance with s.
NR 700.11 (3g).
NR 716.15 Note
Note: Electronic copies should be submitted in the Adobe Portable Document Format (PDF) on optical disk media. Guidance on electronic submittals can be accessed at
http://dnr.wi.gov/files/PDF/pubs/rr/RR690.pdf.
NR 716.15 Note
Note: The department strongly recommends the use of 2-sided copies for the paper copy of the report, and the use of accordion folders for larger reports instead of 3-ring binders, to help address file space issues.
NR 716.15(2)
(2) Report contents. The site investigation report shall include all of the following information required under this subsection, and under subs.
(3) to
(6):
NR 716.15(2)(a)
(a)
Cover letter. A letter referencing the department's identification number for the site or facility and stating the purpose of the submittal and the desired department action or response.
NR 716.15(2)(b)
(b)
Executive summary. A brief narrative describing the site investigation results, conclusions and recommendations for future actions, and the certification required under s.
NR 712.09.
NR 716.15(2)(c)2.
2. Name, address, e-mail address, and telephone number of the present property owner, lessee, operator, and any individual or company responsible for the contamination.
NR 716.15(2)(c)3.
3. Name, address, e-mail address, and telephone number of any consultants or contractors involved with the response action at the site or facility.
NR 716.15(2)(c)4.
4. Site or facility name, address, and location by quarter–quarter section, township, range, and county, along with the Wisconsin Transverse Mercator coordinates for the site. The location of the property and the contamination shall be given in sufficient detail to allow department personnel to inspect the property and the contaminated area.
NR 716.15 Note
Note: The requirements for locating monitoring wells are contained in s.
NR 141.065. Specifically regarding areal location, this section requires that the wells be shown on a plan map with a grid system that is located according to latitude and longitude, or according to a state plane coordinate system. The plan map must show the exact location of the installed well on a horizontal grid system which is accurate to within one foot.