This is the preview version of the Wisconsin State Legislature site.
Please see http://docs.legis.wisconsin.gov for the production version.
NR 664.0001(10)(j) (j) Develop and maintain procedures to prevent accidents and a contingency and emergency plan to control accidents that occur. These procedures shall address proper design, construction, maintenance and operation of remediation waste management units at the site. The goal of the plan shall be to minimize the possibility of, and the hazards from a fire, explosion or any unplanned sudden or non-sudden release of hazardous waste or hazardous waste constituents to air, soil or surface water that could threaten human health or the environment. The plan shall explain specifically how to treat, store and dispose of the hazardous remediation waste in question, and shall be implemented immediately whenever a fire, explosion or release of hazardous waste or hazardous waste constituents which could threaten human health or the environment occurs.
NR 664.0001(10)(k) (k) Designate at least one employee, either on the facility premises or on call (that is, available to respond to an emergency by reaching the facility quickly), to coordinate all emergency response measures. This emergency coordinator shall be thoroughly familiar with all aspects of the facility's contingency plan, all operations and activities at the facility, the location and characteristics of waste handled, the location of all records within the facility, and the facility layout. In addition, this person shall have the authority to commit the resources needed to carry out the contingency plan.
NR 664.0001(10)(L) (L) Develop, maintain and implement a plan to meet the requirements in pars. (b) to (f), (i) and (j).
NR 664.0001(10)(m) (m) Maintain records documenting compliance with pars. (a) to (L).
NR 664.0001 History History: CR 05-032: cr. Register July 2006 No. 607, eff. 8-1-06; CR 16-007: am. (7) (k) 3. Register July 2017 No. 739, eff. 8-1-17; CR 19-082: am. (7) (b), (c), cr. (7) (m) Register August 2020 No 776, eff. 9-1-20; correction in (7) (b) made under s. 35.17, Stats., Register August 2020 No 776; correction in (2) made under s. 13.92 (4) (b) 7., Stats., Register April 2021 No. 784.
NR 664.0003 NR 664.0003Relationship to interim license standards. A facility owner or operator who has fully complied with the requirements for an interim license, as defined in s. 291.25, Stats., and s. NR 670.070, shall comply with ch. NR 665 in lieu of this chapter, until final administrative disposition of the owner or operator's operating license application is made, except as provided under subch. S.
NR 664.0003 Note Note: As stated in s. 291.25, Stats., the treatment, storage or disposal of hazardous waste is prohibited except according to a license. Section 291.25(4), Stats., provides for the interim licensing of an existing facility which meets certain conditions until final administrative disposition of the owner's or operator's operating license application is made.
NR 664.0003 History History: CR 05-032: cr. Register July 2006 No. 607, eff. 8-1-06.
NR 664.0004 NR 664.0004Imminent danger action. Notwithstanding any other provisions of this chapter, enforcement actions may be brought pursuant to 42 USC 6973 (a) and s. 291.85, Stats.
NR 664.0004 History History: CR 05-032: cr. Register July 2006 No. 607, eff. 8-1-06; CR 19-082: am. Register August 2020 No 776, eff. 9-1-20.
subch. B of ch. NR 664 Subchapter B General Facility Standards
NR 664.0010 NR 664.0010Applicability.
NR 664.0010(1)(1)This subchapter applies to owners and operators of all hazardous waste facilities, except as provided in s. NR 664.0001 and sub. (2).
NR 664.0010(2) (2)Section NR 664.0018 (2) applies only to facilities regulated under subchs. I to O and X.
NR 664.0010 History History: CR 05-032: cr. Register July 2006 No. 607, eff. 8-1-06.
NR 664.0011 NR 664.0011Identification number. Every facility owner or operator shall apply to the department for an EPA identification number according to the procedures in s. NR 660.07.
NR 664.0011 History History: CR 05-032: cr. Register July 2006 No. 607, eff. 8-1-06.
NR 664.0012 NR 664.0012Required notices.
NR 664.0012(1)(1)The owner or operator of a facility that is arranging or has arranged to receive hazardous waste subject to subch. H of ch. NR 662 from a foreign source shall submit all of the following required notices:
NR 664.0012(1)(a) (a) In accordance with s. NR 662.084 (2), for imports when the competent authority of the country of export does not require the foreign exporter to submit to it a notification proposing export and obtain consent from EPA and the competent authorities for the countries of transit, the owner or operator of the facility, if acting as the importer, shall provide notification of the proposed transboundary movement in English to EPA using the allowable methods listed in s. NR 662.084 (2) (a) at least 60 days before the first shipment is expected to depart the country of export. The notification may cover up to one year of shipments of wastes having similar physical and chemical characteristics, the same United Nations classification, the same hazardous waste codes and OECD waste codes, and being sent from the same foreign exporter.
NR 664.0012(1)(b) (b) In accordance with s. NR 662.084 (4) (b) 15., a copy of the movement document bearing all required signatures within 3 working days of receipt of the shipment to the foreign exporter; to the competent authorities of the countries of export and transit that control the shipment as an export and transit shipment of hazardous waste respectively; and on or after the electronic import-export reporting compliance date, to EPA electronically using EPA's Waste Import Export Tracking System (WIETS), or its successor system. The original of the signed movement document shall be maintained at the facility for at least 3 years. The owner or operator of a facility may satisfy this recordkeeping requirement by retaining electronically submitted documents in the facility's account on EPA's waste import export tracking system, or its successor system, provided that copies are readily available for viewing and production if requested by EPA or by the department. No owner or operator of a facility shall be held liable for the inability to produce the documents for inspection under this paragraph if the owner or operator of a facility can demonstrate that the inability to produce the document is due exclusively to technical difficulty with EPA's waste import export tracking system, or its successor system for which the owner or operator of a facility bears no responsibility.
NR 664.0012(1)(c) (c) In accordance with s. NR 662.084 (6) (d), if the facility has physical control of the waste and it will be sent to an alternate facility or returned to the country of export, the owner or operator of the facility shall inform EPA, using the allowable methods listed in s. NR 662.084 (2) (a) of the need to return or arrange alternate management of the shipment.
NR 664.0012(1)(d) (d) In accordance with s. NR 662.084 (7), the owner or operator shall do all of the following:
NR 664.0012(1)(d)1. 1. Send copies of the signed and dated confirmation of recovery or disposal, as soon as possible, but no later than 30 days after completing recovery or disposal on the waste in the shipment and no later than one calendar year following receipt of the waste, to the foreign exporter, to the competent authority of the country of export that controls the shipment as an export of hazardous waste, and for shipments recycled or disposed of on or after the electronic import-export reporting compliance date, to EPA electronically using EPA's Waste Import Export Tracking System or its successor system.
NR 664.0012(1)(d)2. 2. If the facility performed any of recovery operations R12, R13, or RC16, or disposal operations D13 through D15, or DC17, promptly send copies of the confirmation of recovery or disposal that it receives from the final recovery or disposal facility within one year of shipment delivery to the final recovery or disposal facility that performed one of recovery operations R1 through R11, or RC16, or one of disposal operations D1 through D12, or DC15 to DC16. Copies of the confirmation shall be also be sent to the competent authority of the country of export that controls the shipment as an export of hazardous waste, and on or after the electronic import-export reporting compliance date, to EPA electronically using EPA's waste import export tracking system, or its successor system. The recovery and disposal operations in this subdivision are defined in s. NR 662.081.
NR 664.0012(2) (2)The owner or operator of a facility that receives hazardous waste from an off-site source (except where the owner or operator is also the generator) shall inform the generator in writing that the owner or operator has the appropriate licenses for, and will accept the waste the generator is shipping. The owner or operator shall keep a copy of this written notice as part of the operating record.
NR 664.0012(3) (3)Before transferring ownership or operation of a facility during its operating life, or of a disposal facility during the long-term care period, the owner or operator shall notify the new owner or operator in writing of the requirements of this chapter and ch. NR 670.
NR 664.0012 Note Note: An owner's or operator's failure to notify the new owner or operator of the requirements of this chapter in no way relieves the new owner or operator of that person's obligation to comply with all applicable requirements.
NR 664.0012 History History: CR 05-032: cr. Register July 2006 No. 607, eff. 8-1-06; CR 19-082: cr. (1) (intro.), r. and recr. (1) (a), (b), cr. (c), (d) Register August 2020 No 776, eff. 9-1-20; correction in (1) (b) made under s. 35.17, Stats., Register August 2020 No. 776; correction in (1) (b) made under s. 13.92 (4) (b) 7., Stats., Register April 2021 No. 784.
NR 664.0013 NR 664.0013General waste analysis.
NR 664.0013(1)(a) (a) Before an owner or operator treats, stores or disposes of any hazardous wastes, or nonhazardous wastes if applicable under s. NR 664.0113 (4), the owner or operator shall obtain a detailed chemical and physical analysis of a representative sample of the wastes. At a minimum, the analysis shall contain all the information which must be known to treat, store or dispose of the waste according to this chapter and ch. NR 668.
NR 664.0013(1)(a)1. 1. Chemical and physical samples shall be analyzed by a laboratory certified or registered under ch. NR 149, except for field analyses for pH, specific conductance and temperature.
NR 664.0013(1)(b) (b) The analysis may include data developed under ch. NR 661, and existing published or documented data on the hazardous waste or on hazardous waste generated from similar processes.
NR 664.0013 Note Note: For example, the facility's records of analyses performed on the waste before the effective date of these rules, or studies conducted on hazardous waste generated from processes similar to that which generated the waste to be managed at the facility, may be included in the data base required to comply with par. (a). The owner or operator of an off-site facility may arrange for the generator of the hazardous waste to supply part of the information required by par. (a), except as otherwise specified in s. NR 668.07(2) and (3). If the generator does not supply the information, and the owner or operator chooses to accept a hazardous waste, the owner or operator is responsible for obtaining the information required to comply with this section.
NR 664.0013(1)(c) (c) The analysis shall be repeated as necessary to ensure that it is accurate and up to date. At a minimum, the analysis shall be repeated when any of the following occurs:
NR 664.0013(1)(c)1. 1. The owner or operator is notified, or has reason to believe, that the process or operation generating the hazardous wastes, or non-hazardous wastes if applicable under s. NR 664.0113 (4), has changed.
NR 664.0013(1)(c)2. 2. For off-site facilities, the results of the inspection required in par. (d) indicate that the hazardous waste received at the facility does not match the waste designated on the accompanying manifest or shipping paper.
NR 664.0013(1)(d) (d) The owner or operator of an off-site facility shall inspect and, if necessary, analyze each hazardous waste movement received at the facility to determine whether it matches the identity of the waste specified on the accompanying manifest or shipping paper.
NR 664.0013(2) (2)The owner or operator shall develop and follow a written waste analysis plan which describes the procedures which the owner or operator will carry out to comply with sub. (1). The owner or operator shall keep this plan at the facility. At a minimum, the plan shall specify all of the following:
NR 664.0013(2)(a) (a) The parameters for which each hazardous waste, or non-hazardous waste if applicable under s. NR 664.0113 (4), will be analyzed and the rationale for the selection of these parameters (i.e., how analysis for these parameters will provide sufficient information on the waste's properties to comply with sub. (1)).
NR 664.0013(2)(b) (b) The test methods which will be used to test for these parameters.
NR 664.0013(2)(c) (c) The sampling method which will be used to obtain a representative sample of the waste to be analyzed. A representative sample may be obtained using one of the following:
NR 664.0013(2)(c)1. 1. One of the sampling methods described in ch. NR 661 Appendix I.
NR 664.0013(2)(c)2. 2. An equivalent sampling method.
NR 664.0013 Note Note: See s. NR 660.21 for related discussion.
NR 664.0013(2)(d) (d) The frequency with which the initial analysis of the waste will be reviewed or repeated to ensure that the analysis is accurate and up to date.
NR 664.0013(2)(e) (e) For off-site facilities, the waste analyses that hazardous waste generators have agreed to supply.
NR 664.0013(2)(f) (f) Where applicable, the methods that will be used to meet the additional waste analysis requirements for specific waste management methods specified in ss. NR 664.0017, 664.0314, 664.0341, 664.1034 (4), 664.1063 (4), 664.1083 and 668.07.
NR 664.0013(2)(g) (g) For surface impoundments exempted from land disposal restrictions under s. NR 668.04 (1), the procedures and schedules for all of the following:
NR 664.0013(2)(g)1. 1. The sampling of impoundment contents.
NR 664.0013(2)(g)2. 2. The analysis of test data.
NR 664.0013(2)(g)3. 3. The annual removal of residues which are not delisted under s. NR 660.22 or which exhibit a characteristic of hazardous waste and meet any of the following criteria:
NR 664.0013(2)(g)3.a. a. The residues do not meet applicable treatment standards of subch. D of ch. NR 668.
NR 664.0013(2)(g)3.b. b. Where no treatment standards have been established, any of the following applies:
1) The residues are prohibited from land disposal under s. NR 668.32 or 42 USC 6924(d).
2) The residues are prohibited from land disposal under s. NR 668.33.
NR 664.0013(2)(h) (h) For owners and operators seeking an exemption to the air emission standards of subch. CC according to s. NR 664.1082, any of the following:
NR 664.0013(2)(h)1. 1. If direct measurement is used for the waste determination, the procedures and schedules for waste sampling and analysis, and the results of the analysis of test data to verify the exemption.
NR 664.0013(2)(h)2. 2. If knowledge of the waste is used for the waste determination, any information prepared by the facility owner or operator or by the generator of the hazardous waste, if the waste is received from off-site, that is used as the basis for knowledge of the waste.
NR 664.0013(3) (3)For off-site facilities, the waste analysis plan required in sub. (2) shall also specify the procedures which will be used to inspect and, if necessary, analyze each movement of hazardous waste received at the facility to ensure that it matches the identity of the waste designated on the accompanying manifest or shipping paper. At a minimum, the plan shall describe all of the following:
NR 664.0013(3)(a) (a) The procedures which will be used to determine the identity of each movement of waste managed at the facility.
NR 664.0013(3)(b) (b) The sampling method which will be used to obtain a representative sample of the waste to be identified, if the identification method includes sampling.
NR 664.0013 Note Note: Chapter NR 670 requires that the waste analysis plan be submitted with the feasibility and plan of operation report.
NR 664.0013(3)(c) (c) The procedures that the owner or operator of an off-site landfill receiving containerized hazardous waste will use to determine whether a hazardous waste generator or treater has added a biodegradable sorbent to the waste in the container.
NR 664.0013 History History: CR 05-032: cr. Register July 2006 No. 607, eff. 8-1-06; correction in (2) (c) 1. made under s. 13.92 (4) (b) 7., Stats., Register March 2013 No. 687; correction in (1) (b) made under s. 13.92 (4) (b) 7., Stats., Register April 2021 No. 784.
NR 664.0014 NR 664.0014Security.
NR 664.0014(1)(1)The owner or operator shall prevent the unknowing entry, and minimize the possibility for the unauthorized entry, of persons or livestock onto the active portion of the facility, unless the owner or operator can demonstrate to the department all of the following:
NR 664.0014(1)(a) (a) Physical contact with the waste, structures, or equipment within the active portion of the facility will not injure unknowing or unauthorized persons or livestock which may enter the active portion of a facility.
NR 664.0014(1)(b) (b) Disturbance of the waste or equipment, by the unknowing or unauthorized entry of persons or livestock onto the active portion of a facility, will not cause a violation of the requirements of this chapter.
NR 664.0014 Note Note: Chapter NR 670 requires that an owner or operator who wishes to make the demonstration referred to in pars. (a) and (b) shall do so with the feasibility report or feasibility and plan of operation report.
NR 664.0014(2) (2)Unless the owner or operator has made a successful demonstration under sub. (1) (a) and (b), a facility shall have any of the following:
NR 664.0014(2)(a) (a) A 24-hour surveillance system (e.g., television monitoring or surveillance by guards or facility personnel) which continuously monitors and controls entry onto the active portion of the facility.
NR 664.0014(2)(b) (b) All of the following:
NR 664.0014(2)(b)1. 1. An artificial or natural barrier (e.g., a fence in good repair or a fence combined with a cliff), which completely surrounds the active portion of the facility.
NR 664.0014(2)(b)2. 2. A means to control entry, at all times, through the gates or other entrances to the active portion of the facility (e.g., an attendant, television monitors, locked entrance or controlled roadway access to the facility).
NR 664.0014 Note Note: The requirements of sub. (2) are satisfied if the facility or plant within which the active portion is located itself has a surveillance system, or a barrier and a means to control entry, which complies with the requirements of par. (a) or (b).
NR 664.0014(3) (3)Unless the owner or operator has made a successful demonstration under sub. (1) (a) and (b), a sign with the legend, “Danger—Unauthorized Personnel Keep Out", shall be posted at each entrance to the active portion of a facility, and at other locations, in sufficient numbers to be seen from any approach to this active portion. The legend shall be written in English and in any other language predominant in the area surrounding the facility, and shall be legible from a distance of at least 25 feet. Existing signs with a legend other than “Danger—Unauthorized Personnel Keep Out" may be used if the legend on the sign indicates that only authorized personnel are allowed to enter the active portion, and that entry onto the active portion can be dangerous.
NR 664.0014 Note Note: See s. NR 664.0117(2) for discussion of security requirements at disposal facilities during the long-term care period.
NR 664.0014 History History: CR 05-032: cr. Register July 2006 No. 607, eff. 8-1-06.
NR 664.0015 NR 664.0015General inspection requirements.
NR 664.0015(1)(1)The owner or operator shall inspect the facility for malfunctions and deterioration, operator errors and discharges which may be causing, or may lead to, release of hazardous waste constituents to the environment or a threat to human health. The owner or operator shall conduct these inspections often enough to identify problems in time to correct them before they harm human health or the environment.
NR 664.0015(2)(a)(a) The owner or operator shall develop and follow a written schedule for inspecting monitoring equipment, safety and emergency equipment, security devices and operating and structural equipment (such as dikes and sump pumps) that are important to preventing, detecting or responding to environmental or human health hazards.
NR 664.0015(2)(b) (b) The owner or operator shall keep this schedule at the facility.
NR 664.0015(2)(c) (c) The schedule shall identify the types of problems (e.g., malfunctions or deterioration) which are to be looked for during the inspection (e.g., inoperative sump pump, leaking fitting, eroding dike, etc.).
NR 664.0015 Note Note: Chapter NR 670 requires the inspection schedule to be submitted with the feasibility and plan of operation report. The department shall evaluate the schedule along with the rest of the report to ensure that it adequately protects human health and the environment. As part of this review, the department may modify or amend the schedule as may be necessary.
NR 664.0015(2)(d) (d) The frequency of inspection may vary for the items on the schedule. However, the frequency should be based on the rate of deterioration of the equipment and the probability of an environmental or human health incident if the deterioration, malfunction or any operator error goes undetected between inspections. Areas subject to spills, such as loading and unloading areas, shall be inspected daily when in use. At a minimum, the inspection schedule shall include the items and frequencies called for in ss. NR 664.0174, 664.0193, 664.0195, 664.0226, 664.0254, 664.0303, 664.0347, 664.0602, 664.1033, 664.1052, 664.1053, 664.1058 and 664.1083 to 664.1089, where applicable. Chapter NR 670 requires the inspection schedule to be submitted with part B of the license application. The department will evaluate the schedule along with the rest of the application to ensure that it adequately protects human health and the environment. As part of this review, the department may modify or amend the schedule as necessary.
NR 664.0015(3) (3)The owner or operator shall remedy any deterioration or malfunction of equipment or structures which the inspection reveals on a schedule which ensures that the problem does not lead to an environmental or human health hazard. Where a hazard is imminent or has already occurred, remedial action shall be taken immediately.
Loading...
Loading...
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date the chapter was last published.