NR 661.1033(14)
(14) An owner or operator using a carbon adsorption system to control air pollutant emissions shall document that all carbon that is a hazardous waste and that is removed from the control device is managed in one of the following manners, regardless of the average volatile organic concentration of the carbon:
NR 661.1033(14)(a)
(a) Regenerated or reactivated in a thermal treatment unit that meets one of the following:
NR 661.1033(14)(a)2.
2. The unit is equipped with and operating air emission controls in accordance with the applicable requirements specified in either subchs.
AA and
CC of this chapter or subchs.
AA and
CC of ch. NR 665.
NR 661.1033(14)(b)
(b) Incinerated in a hazardous waste incinerator for which any of the following conditions has been met:
NR 661.1033(14)(b)2.
2. The owner or operator has designed and operates the incinerator in accordance with the interim status requirements specified in subch.
O of ch. NR 665.
NR 661.1033(14)(c)
(c) Burned in a boiler or industrial furnace for which any of the following conditions has been met:
NR 661.1033(14)(c)2.
2. The owner or operator has designed and operates the boiler or industrial furnace in accordance to the interim license requirements specified in subch.
H of ch. NR 666.
NR 661.1033(15)
(15) Any components of a closed-vent system that are designated, as described in s.
NR 661.1035 (3) (i), as unsafe to monitor are exempt from the requirements specified in sub.
(12) (a) 2. b. if the remanufacturer or other person does all of the following:
NR 661.1033(15)(a)
(a) The remanufacturer or other person that stores or treats the hazardous secondary material in a hazardous secondary material management unit using a closed-vent system determines that the components of the closed-vent system are unsafe to monitor because monitoring personnel would be exposed to an immediate danger as a consequence of complying with sub.
(12) (a) 2. b. NR 661.1033(15)(b)
(b) The remanufacturer or other person that stores or treats the hazardous secondary material in a hazardous secondary material management unit using a closed-vent system adheres to a written plan that requires monitoring the closed-vent system components using the procedure specified in sub.
(12) (a) 2. b. as frequently as practicable during safe-to-monitor times.
NR 661.1033 History
History: CR 19-082: cr.
Register August 2020 No. 776, eff. 9-1-20; renum. (1) (a) to (1) under s.
13.92 (4) (b) 7., Stats., and correction in (14) (a) 2., 3., (b) 2. made under s.
35.17, Stats.,
Register August 2020 No. 776;
correction in (14) (a) 1., (b) 1. made under s. 13.92 (4) (b) 7., Stats., Register April 2021 No. 784. NR 661.1034(1)(1)
A remanufacturer or other person that stores or treats hazardous secondary material subject to the provisions of this subchapter shall comply with the test methods and procedural requirements provided in this section.
NR 661.1034(2)
(2) When a closed-vent system is tested for compliance with no detectable emissions, as required under s.
NR 661.1033 (12), the test shall comply with all of the following requirements:
NR 661.1034(2)(c)
(c) The instrument shall be calibrated before use on each day of its use by the procedures specified in Reference Method 21 in appendix A of
40 CFR part 60, incorporated by reference in s.
NR 660.11.
NR 661.1034(2)(d)2.
2. A mixture of methane or n-hexane and air at a concentration of approximately, but less than, 10,000 ppm methane or n-hexane.
NR 661.1034(2)(f)
(f) The instrument probe shall be traversed around all potential leak interfaces as close to the interface as possible as described in Reference Method 21 in appendix A of
40 CFR part 60, incorporated by reference in s.
NR 660.11.
NR 661.1034(2)(g)
(g) The arithmetic difference between the maximum concentration indicated by the instrument and the background level shall be compared with 500 ppm for determining compliance.
NR 661.1034(3)(a)
(a) Performance tests to determine total organic compound concentrations and mass flow rates entering and exiting control devices shall be conducted and data reduced in accordance with all of the following reference methods and calculation procedures:
NR 661.1034(3)(a)2.
2. Method 18 or Method 25A in appendix A of
40 CFR part 60, incorporated by reference in s.
NR 660.11, for organic content. If Method 25A is used, the organic HAP used as the calibration gas shall be the single organic HAP representing the largest percent by volume of the emissions. The use of Method 25A is acceptable if the response from the high-level calibration gas is at least 20 times the standard deviation of the response from the zero calibration gas when the instrument is zeroed on the most sensitive scale.
NR 661.1034(3)(a)3.
3. Each performance test shall consist of 3 separate runs
. Each run shall be conducted for at least 1 hour under the conditions that exist when the hazardous secondary material management unit is operating at the highest load or capacity level reasonably expected to occur. For the purpose of determining total organic compound concentrations and mass flow rates, the average of results of all runs shall apply. The average shall be computed on a time-weighted basis.
NR 661.1034(3)(a)4.
4. Total organic mass flow rates shall be determined by one of the following equations:
Where:
Eh= Total organic mass flow rate, kg/h
Q2sd= Volumetric flow rate of gases entering or exiting control device, as determined by Method 2, dscm/h
n = Number of organic compounds in the vent gas
Ci= Organic concentration in ppm, dry basis, of compound i in the vent gas, as determined by Method 18
MWi= Molecular weight of organic compound i in the vent gas, kg/kg-mol
0.0416 = Conversion factor for molar volume, kg-mol/m3 (@293 K and 760 mm Hg)
10-6 = Conversion from ppm
Where:
Eh= Total organic mass flow rate, kg/h
Q = Volumetric flow rate of gases entering or exiting control device, as determined by Method 2, dscm/h
C = Organic concentration in ppm, dry basis, as determined by Method 25A
MW = Molecular weight of propane, 44
0.0416 = Conversion factor for molar volume, kg-mol/m3 (@293 K and 760 mm Hg)
10-6 = Conversion from ppm.
NR 661.1034(3)(a)5.
5. The annual total organic emission rate shall be determined by the following equation:
Where:
EA = Total organic mass emission rate, kg/y
Eh = Total organic mass flow rate for the process vent, kg/h
H = Total annual hours of operations for the affected unit, h
NR 661.1034(3)(a)6.
6. Total organic emissions from all affected process vents at the facility shall be determined by summing the hourly total organic mass emission rates
, E
h, as determined in subd.
4., and by summing the annual total organic mass emission rates
, E
A, as determined in subd.
5., for all affected process vents at the facility.
NR 661.1034(3)(b)
(b) The remanufacturer or other person that stores or treats the hazardous secondary material shall record process information that may be necessary to determine the conditions of the performance tests. Operations during periods of startup, shutdown, and malfunction may not constitute representative conditions for the purpose of a performance test.
NR 661.1034(3)(c)
(c) The remanufacturer or other person that stores or treats the hazardous secondary material at an affected facility shall provide, or cause to be provided, all of the following performance testing facilities:
NR 661.1034(3)(d)
(d) For the purpose of making compliance determinations, the time-weighted average of the results of the 3 runs required in par.
(a) 3. shall apply. In the event that a sample is accidentally lost or conditions occur in which one of the 3 runs must be discontinued because of forced shutdown, failure of an irreplaceable portion of the sample train, extreme meteorological conditions, or other circumstances beyond the control of the remanufacturer or other person that stores or treats the hazardous secondary material, compliance may, upon the department's approval, be determined using the average of the results of the 2 other runs.
NR 661.1034(4)
(4) To show that a process vent associated with a hazardous secondary material distillation, fractionation, thin-film evaporation, solvent extraction, or air or steam stripping operation is not subject to the requirements of this subchapter, the remanufacturer or other person that stores or treats the hazardous secondary material shall make an initial determination that the time-weighted, annual average total organic concentration of the material managed by the hazardous secondary material management unit is less than 10 ppmw using one of the following 2 methods:
NR 661.1034(4)(a)
(a) Direct measurement of the organic concentration of the material using all of the following procedures:
NR 661.1034(4)(a)1.
1. The remanufacturer or other person that stores or treats the hazardous secondary material shall take a minimum of 4 grab samples of material for each material stream managed in the affected unit under process conditions expected to cause the maximum material organic concentration.
NR 661.1034(4)(a)2.
2. For material generated on-site, the grab samples shall be collected at a point before the material is exposed to the atmosphere such as in an enclosed pipe or other closed system that is used to transfer the material after generation to the first affected distillation, fractionation, thin-film evaporation, solvent extraction, or air or steam stripping operation. For material generated off-site, the grab samples shall be collected at the inlet to the first material management unit that receives the material
, provided the material has been transferred to the facility in a closed system such as a tank truck and the material is not diluted or mixed with other material.
NR 661.1034(4)(a)3.
3. Each sample shall be analyzed and the total organic concentration of the sample shall be computed using Method 9060A of “Test Methods for Evaluating Solid Waste, Physical/Chemical Methods,” EPA Publication SW-846, incorporated by reference in s.
NR 660.11, or analyzed for its individual organic constituents.
NR 661.1034(4)(a)4.
4. The arithmetic mean of the results of the analyses of the 4 samples shall apply for each material stream managed in the unit in determining the time-weighted, annual average total organic concentration of the material. The time-weighted average shall be calculated using the annual quantity of each material stream processed and the mean organic concentration of each material stream managed in the unit.
NR 661.1034(4)(b)
(b) Using knowledge of the material to determine that its total organic concentration is less than 10 ppmw. Documentation of the material determination is required. Examples of documentation that shall be used to support a determination under this provision include production process information documenting that no organic compounds are used, information that the material is generated by a process that is identical to a process at the same or another facility that has previously been demonstrated by direct measurement to generate a material stream having a total organic content less than 10 ppmw, or prior speciation analysis results on the same material stream where it can also be documented that no process changes have occurred since that analysis that could affect the material total organic concentration.
NR 661.1034(5)
(5) The determination that distillation, fractionation, thin-film evaporation, solvent extraction, or air or steam stripping operations manage hazardous secondary material with time-weighted, annual average total organic concentrations less than 10 ppmw shall be made by the remanufacturer or other person in accordance with all the following:
NR 661.1034(5)(a)
(a) By the effective date that the facility becomes subject to the provisions of this subchapter or by the date when the material is first managed in a hazardous secondary material management unit, whichever is later.
NR 661.1034(5)(b)
(b) Annually for continuously generated material, or whenever there is a change in the material being managed or a change in the process that generates or treats the material.
NR 661.1034(6)
(6) When a remanufacturer or other person that stores or treats the hazardous secondary material and the department do not agree on whether a distillation, fractionation, thin-film evaporation, solvent extraction, or air or steam stripping operation manages a hazardous secondary material with organic concentrations of at least 10 ppmw based on knowledge of the material, the dispute may be resolved by using direct measurement as specified in sub.
(4) (a).
NR 661.1034 History
History: CR 19-082: cr.
Register August 2020 No. 776, eff. 9-1-20; correction in (1), (2) (a), (4) (a) 3. made under s.
35.17, Stats.,
Register August 2020 No. 776.
NR 661.1035(1)(a)
(a) A remanufacturer or other person that stores or treats the hazardous secondary material subject to the provisions of this subchapter shall comply with the recordkeeping requirements of this section.
NR 661.1035(1)(b)
(b) A remanufacturer or other person that stores or treats the hazardous secondary material of more than one hazardous secondary material management unit subject to the provisions of this subchapter may comply with the recordkeeping requirements for these hazardous secondary material management units in one recordkeeping system if the system identifies each record by each hazardous secondary material management unit.
NR 661.1035(2)
(2) A remanufacturer or other person that stores or treats the hazardous secondary material shall keep all of the following records on-site:
NR 661.1035(2)(a)
(a) For facilities that comply with the provisions specified in s.
NR 661.1033 (1), an implementation schedule that includes dates by which the closed-vent system and control device will be installed and in operation. The schedule shall also include a rationale of why the installation cannot be completed at an earlier date. The implementation schedule shall be kept on-site at the facility by the effective date that the facility becomes subject to the provisions of this subchapter.
NR 661.1035(2)(b)
(b) Up-to-date documentation of compliance with the process vent standards specified in s.
NR 661.1032, including all of the following:
NR 661.1035(2)(b)1.
1. Information and data identifying all affected process vents, annual throughput and operating hours of each affected unit, estimated emission rates for each affected vent and for the overall facility, and the approximate location within the facility of each affected unit, such as identifying the hazardous secondary material management units on a facility plot plan.
NR 661.1035(2)(b)2.
2. Information and data supporting determinations of vent emissions and emission reductions achieved by add-on control devices based on engineering calculations or source tests. For the purpose of determining compliance, determinations of vent emissions and emission reductions shall be made using operating parameter values, such as temperatures, flow rates, or vent stream organic compounds and concentrations, that represent the conditions that result in maximum organic emissions, such as when the hazardous secondary material management unit is operating at the highest load or capacity level reasonably expected to occur. If the remanufacturer or other person that stores or treats the hazardous secondary material takes any action, such as managing a material of different composition or increasing operating hours of affected hazardous secondary material management units, that would result in an increase in total organic emissions from affected process vents at the facility, then a new determination is required.
NR 661.1035(2)(c)
(c) When a remanufacturer or other person that stores or treats the hazardous secondary material chooses to use test data to determine the organic removal efficiency or total organic compound concentration achieved by the control device, a performance test plan shall be developed and include all of the following:
NR 661.1035(2)(c)1.
1. A description of how it is determined that the planned test is going to be conducted when the hazardous secondary material management unit is operating at the highest load or capacity level reasonably expected to occur. This shall include the estimated or design flow rate and organic content of each vent stream and define the acceptable operating ranges of key process and control device parameters during the test program.