NR 466.12(2)(e)1.
1. If actions taken by an owner or operator during a startup, shutdown or malfunction of an affected source, including actions taken to correct a malfunction, are not completely consistent with the procedures specified in the source's startup, shutdown and malfunction plan as specified in
s. NR 460.05 (4) (c), the owner or operator shall state the information in the report. The startup, shutdown or malfunction report shall consist of a letter containing the name, title and signature of the responsible official who is certifying its accuracy, that shall be submitted to the department.
NR 466.12(2)(e)2.
2. Separate startup, shutdown or malfunction reports are not required if the information is included in the report specified in
par. (f).
NR 466.12 History
History: Cr.
Register, March, 2000, No. 531, eff. 4-1-00.
NR 466.21
NR 466.21 What this subchapter covers. NR 466.21(1)
(1)
What is in this subchapter? This subchapter describes the actions you must take to reduce emissions of organic hazardous air pollutants (HAP) from paper and other web coating operations. This subchapter establishes emission standards for web coating lines and specifies what you must do to comply if you own or operate a facility with web coating lines that is a major source of HAP. Certain requirements apply to all who are subject to this subchapter; others depend on the means you use to comply with an emission standard.
NR 466.21 Note
Note: This subchapter is based on the federal regulations contained in
40 CFR part 63 Subpart JJJJ, as created on December 4, 2002 as amended at 71 FR 29805, May 24, 2006.
NR 466.21(2)
(2) Does this subchapter apply to me? The provisions of this subchapter apply to each new and existing facility that is a major source of HAP at which web coating lines are operated.
NR 466.21(3)
(3) Which of my emission sources are affected by this subchapter? The affected source subject to this subchapter is the collection of all web coating lines at your facility. The affected source includes web coating lines engaged in the coating of metal webs that are used in flexible packaging and web coating lines engaged in the coating of fabric substrates for use in pressure sensitive tape and abrasive materials. Web coating lines specified in
pars. (a) to
(g) are not part of the affected source under this subchapter.
NR 466.21(3)(a)
(a) Any web coating line that is stand-alone coating equipment under subch.
I which the owner or operator includes in the affected source under subch.
I.
NR 466.21(3)(b)
(b) Any web coating line that is a product and packaging rotogravure or wide-web flexographic press under subch.
I which is included in the affected source under subch.
I.
NR 466.21(3)(c)
(c) Web coating in lithography, screen printing, letterpress and narrow-web flexographic printing processes.
NR 466.21(3)(f)
(f) Any web coating line subject to
40 CFR part 63, Subpart OOOO, the NESHAP for the printing, coating and dyeing of fabric and other textiles. Any web coating line that coats both a paper or other web substrate and a fabric or other textile substrate, except for a fabric substrate used for pressure sensitive tape and abrasive materials, is subject to
40 CFR part 63, Subpart OOOO.
NR 466.21 History
History: CR 07-045: cr. Register April 2008 No. 628, eff. 5-1-08. NR 466.22
NR 466.22 What definitions are used in this subchapter? For terms not defined in this section, the definitions contained in
chs. NR 400 and
460 apply to the terms in this subchapter, with definitions in
ch. NR 460 taking precedence over definitions in
ch. NR 400. If this section defines a term which is also defined in
ch. NR 400 or
460, the definition in this section applies in this subchapter. In this subchapter:
NR 466.22(1)
(1) “Always-controlled work station" means a work station associated with a dryer from which the exhaust is delivered to a control device with no provision for the dryer exhaust to bypass the control device unless there is an interlock to interrupt and prevent continued coating during a bypass. Sampling lines for analyzers, relief valves needed for safety purposes and periodic cycling of exhaust dampers to ensure safe operation are not considered bypass lines.
NR 466.22(2)
(2) “Applied" means the amount of organic HAP, coating material or coating solids, as appropriate for the emission standards in
s. NR 466.23 (1) (b) used by the affected source during the compliance period.
NR 466.22(3)
(3) “As-applied" means the condition of a coating at the time of application to a substrate, including any added solvent.
NR 466.22(4)
(4) “As-purchased" means the condition of a coating as delivered to the user.
NR 466.22(5)
(5) “Capture efficiency" means the fraction of all organic HAP emissions generated by a process that is delivered to a control device, expressed as a percentage.
NR 466.22(6)
(6) “Capture system" means a hood, enclosed room or other means of collecting organic HAP emissions into a closed-vent system that exhausts to a control device.
NR 466.22(7)
(7) “Car-seal" means a seal that is placed on a device that is used to change the position of a valve or damper, for example from open to closed, in such a way that the position of the valve or damper cannot be changed without breaking the seal.
NR 466.22(8)
(8) “Coating material" means all inks, varnishes, adhesives, primers, solvents, reducers and other materials applied to a substrate via a web coating line. Materials used to form a substrate are not considered coating materials.
NR 466.22(9)
(9) “Control device" means a device such as a solvent recovery device or oxidizer which reduces the organic HAP in an exhaust gas by recovery or by destruction.
NR 466.22(10)
(10) “Control device efficiency" means the ratio of organic HAP emissions recovered or destroyed by a control device to the total organic HAP emissions that are introduced into the control device, expressed as a percentage.
NR 466.22(12)
(12) “Deviation" means any instance in which an affected source subject to this subchapter or an owner or operator of an affected source does any of the following:
NR 466.22(12)(a)
(a) Fails to meet any requirement or obligation established by this subchapter, including any emission limitation, operating limit or work practice standard.
NR 466.22(12)(b)
(b) Fails to meet any term or condition that is adopted to implement an applicable requirement in this subchapter and that is included in the operating permit for any affected source required to obtain an operating permit.
NR 466.22(12)(c)
(c) Fails to meet any emission limitation, operating limit or work practice standard in this subchapter during start-up, shutdown or malfunction, regardless of whether or not the failure is permitted by this subchapter.
NR 466.22(13)
(13) “Existing affected source" means any affected source the construction or reconstruction of which is commenced on or before September 13, 2000, and which has not undergone reconstruction as defined in
s. NR 460.02.
NR 466.22(14)
(14) “Fabric" means any woven, knitted, plaited, braided, felted or non-woven material made of filaments, fibers or yarns, including thread. This term includes material made of fiberglass, natural fibers, synthetic fibers or composite materials.
NR 466.22(15)
(15) “Facility" means all contiguous or adjoining property that is under common ownership or control, including properties that are separated only by a road or other public right-of-way.
NR 466.22(16)
(16) “Flexible packaging" means any package or part of a package the shape of which can be readily changed. Flexible packaging includes bags, pouches, labels, liners and wraps utilizing paper, plastic, film, aluminum foil, metalized or coated paper or film or any combination of these materials.
NR 466.22(17)
(17) “Formulation data" means data on the organic HAP mass fraction, volatile matter mass fraction or coating solids mass fraction of a material that is generated by the manufacturer or means other than a test method specified in this subchapter or an approved alternative method.
NR 466.22(18)
(18) “HAP applied" means the organic HAP content of all coating materials applied to a substrate by a web coating line at an affected source.
NR 466.22(19)
(19) “Intermittently-controlled work station" means a work station associated with a dryer with provisions for the dryer exhaust to be delivered to or diverted from a control device through a bypass line, depending on the position of a valve or damper. Sampling lines for analyzers, relief valves needed for safety purposes and periodic cycling of exhaust dampers to ensure safe operation are not considered bypass lines.
NR 466.22(20)
(20) “Metal coil" means a continuous metal strip that is at least 0.15 millimeter (0.006 inch) thick which is packaged in a roll or coil prior to coating. After coating, it may or may not be rewound into a roll or coil. Metal coil does not include metal webs that are coated for use in flexible packaging.
NR 466.22(21)
(21) “Month" means a calendar month or a pre-specified period of 28 days to 35 days to allow for flexibility in recordkeeping when data are based on a business accounting period.
NR 466.22(22)
(22) “Never-controlled work station" means a work station that is not equipped with provisions by which any emissions, including those in the exhaust from any associated dryer, may be delivered to a control device.
NR 466.22(23)
(23) “New affected source" means any affected source the construction or reconstruction of which is commenced after September 13, 2000.
NR 466.22(24)
(24) “Overall organic HAP control efficiency" means the total efficiency of a capture and control system.
NR 466.22(25)
(25) “Pressure sensitive tape" means a flexible backing material with a pressure-sensitive adhesive coating on one or both sides of the backing.
NR 466.22(26)
(26) “Research or laboratory equipment" means any equipment for which the primary purpose is to conduct research and development into new processes and products where the equipment is operated under the close supervision of technically trained personnel and is not engaged in the manufacture of products for commercial sale in commerce except in a de minimis manner.
NR 466.22(27)
(27) “Rewind or cutting station" means a unit from which substrate is collected at the outlet of a web coating line.
NR 466.22(28)
(28) “Uncontrolled coating line" means a coating line consisting of only never-controlled work stations.
NR 466.22(29)
(29) “Unwind or feed station" means a unit from which substrate is fed to a web coating line.
NR 466.22(30)
(30) “Web" means a continuous substrate, such as paper, film or foil, which is flexible enough to be wound or unwound as rolls.
NR 466.22(31)
(31) “Web coating line" means any number of work stations, of which one or more applies a continuous layer of coating material across the entire width or any portion of the width of a web substrate, and any associated curing or drying equipment between an unwind or feed station and a rewind or cutting station.
NR 466.22(32)
(32) “Work station" means a unit on a web coating line where coating material is deposited onto a web substrate.
NR 466.22(33)
(33) “You" means the owner or operator of a new or existing facility that is a major source of HAP at which web coating lines are operated.
NR 466.22(34)
(34) “Your" means of or relating to the owner or operator of a new or existing facility that is a major source of HAP at which web coating line are operated.
NR 466.22 History
History: CR 07-045: cr. Register April 2008 No. 628, eff. 5-1-08. NR 466.23
NR 466.23 Emission standards and compliance dates. NR 466.23(1)(a)(a) If you own or operate any affected source that is subject to the requirements of this subchapter, you shall comply with the requirements in this section on and after the compliance dates specified in
sub. (3).
NR 466.23(1)(b)
(b) You shall limit organic HAP emissions to the level specified in one of the following:
NR 466.23(1)(b)1.
1. No more than 5% of the organic HAP applied for each month (95% reduction) at existing affected sources and no more than 2% of the organic HAP applied for each month (98% reduction) at new affected sources.
NR 466.23(1)(b)2.
2. No more than 4% of the mass of coating materials applied for each month at existing affected sources and no more than 1.6% of the mass of coating materials applied for each month at new affected sources.
NR 466.23(1)(b)3.
3. No more than 20% of the mass of coating solids applied for each month at existing affected sources and no more than 8% of the coating solids applied for each month at new affected sources.
NR 466.23(1)(b)4.
4. If you use an oxidizer to control organic HAP emissions, operate the oxidizer such that an outlet organic HAP concentration of no greater than 20 parts per million by volume (ppmv) by compound on a dry basis is achieved and the efficiency of the capture system is 100%.
NR 466.23(2)(a)(a) For any web coating line or group of web coating lines for which you use add-on control devices, unless you use a solvent recovery system and conduct a liquid-liquid material balance, you shall meet the operating limits specified in Table 1 of this subchapter or the requirements in
par. (b). The operating limits apply to emission capture systems and control devices, and you shall establish the operating limits during the performance test according to the requirements in
s. NR 466.24 (3) (e) 3. You shall meet the operating limits at all times after you establish them.
NR 466.23(2)(b)
(b) If you use an add-on control device other than those listed in Table 1 of this subchapter or wish to monitor an alternative parameter and comply with a different operating limit, you shall apply to the administrator for approval of alternative monitoring under
s. NR 460.07 (6).
NR 466.23(3)(a)(a) If you own or operate an existing affected source subject to the provisions of this subchapter, you shall comply by the compliance date. The compliance date for existing affected sources is December 5, 2005. You shall complete any performance test required in
s. NR 466.24 (3) within the time limits specified in
s. NR 460.06 (1) (b).
NR 466.23(3)(b)
(b) If you own or operate a new affected source subject to the provisions of this subchapter, your compliance date is immediately upon start-up of the new affected source or by December 4, 2002, whichever is later. You shall complete any performance test required in
s. NR 466.24 (3) within the time limits specified in
s. NR 460.06 (1) (b).
NR 466.23(3)(c)
(c) If you own or operate a reconstructed affected source subject to the provisions of this subchapter, your compliance date is immediately upon startup of the affected source or by December 4, 2002, whichever is later. Existing affected sources which have undergone reconstruction as defined in
s. NR 460.02 are subject to the requirements for new affected sources. The costs associated with the purchase and installation of air pollution control equipment are not considered in determining whether the existing affected source has been reconstructed. Additionally, the costs of retrofitting and replacing equipment that is installed specifically to comply with this subchapter are not considered reconstruction costs. You shall complete any performance test required in
s. NR 466.24 (3) within the time limits specified in
s. NR 460.06 (1) (b).
NR 466.23 History
History: CR 07-045: cr. Register April 2008 No. 628, eff. 5-1-08. NR 466.24
NR 466.24 General requirements for compliance with the emission standards and for monitoring and performance tests. NR 466.24(1)
(1)
What general requirements must I meet to comply with the standards? You shall comply with the applicable general provisions of
ch. NR 460 as specified in
ch. NR 460 Appendix JJJJ.
NR 466.24(2)
(2) If I use a control device to comply with the emission standards, what monitoring must I do? NR 466.24(2)(b)
(b)
Capture system and control device monitoring. Following the date on which the initial performance test of a control device is completed to demonstrate continuing compliance with the standards, you shall monitor and inspect each capture system and each control device used to comply with
s. NR 466.23 (1). You shall install and operate the monitoring equipment as specified in
pars. (c) and
(f).
NR 466.24(2)(c)
(c)
Bypass and coating use monitoring. If you own or operate web coating lines with intermittently-controlled work stations, you shall monitor bypasses of the control device and the mass of each coating material applied at the work station during any bypass. If using a control device for complying with the requirements of this subchapter, you shall demonstrate that any coating material applied on a never-controlled work station or an intermittently-controlled work station operated in bypass mode is allowed in your compliance demonstration according to
s. NR 466.25 (14) and
(15). The bypass monitoring shall be conducted using at least one of the procedures in
subds. 1. to
4. for each work station and associated dryer.
NR 466.24(2)(c)1.
1. `Flow control position indicator.' Install, calibrate, maintain and operate according to the manufacturer's specifications a flow control position indicator that provides a record indicating whether the exhaust stream from the dryer was directed to the control device or was diverted from the control device. The time and flow control position shall be recorded at least once per hour as well as every time the flow direction is changed. A flow control position indicator shall be installed at the entrance to any bypass line that could divert the exhaust stream away from the control device to the atmosphere.
NR 466.24(2)(c)2.
2. `Car-seal or lock-and-key valve closures.' Secure any bypass line valve in the closed position with a car-seal or a lock-and-key type configuration. A visual inspection of the seal or closure mechanism shall be performed at least once every month to ensure that the valve or damper is maintained in the closed position, and the exhaust stream is not diverted through the bypass line.
NR 466.24(2)(c)3.
3. `Valve closure continuous monitoring.' Ensure that any bypass line valve or damper is in the closed position through continuous monitoring of valve position when the emission source is in operation and is using a control device for compliance with the requirements of this subchapter. The monitoring system shall be inspected at least once every month to verify that the monitor will indicate valve position.
NR 466.24(2)(c)4.
4. `Automatic shutdown system.' Use an automatic shutdown system in which the web coating line is stopped when flow is diverted away from the control device to any bypass line when the control device is in operation. The automatic system shall be inspected at least once every month to verify that it will detect diversions of flow and would shut down operations in the event of such a diversion.
NR 466.24(2)(d)
(d)
Solvent recovery unit. If you own or operate a solvent recovery unit to comply with
s. NR 466.23 (1), you shall meet the requirements in either
subd. 1. or
2., depending on how control efficiency is determined.