This is the preview version of the Wisconsin State Legislature site.
Please see http://docs.legis.wisconsin.gov for the production version.
NR 466.05 History History: Cr. Register, March, 2000, No. 531, eff. 4-1-00.
NR 466.06 NR 466.06Standards: publication rotogravure printing.
NR 466.06(1)(1)Compliance dates. Each owner or operator of any publication rotogravure printing affected source that is subject to the requirements of this chapter shall comply with this section on and after the compliance dates as specified in s. NR 466.08.
NR 466.06(2) (2)Emission limitation. The owner or operator of each publication rotogravure affected source shall limit organic HAP emissions to no more than 8% of the total volatile matter used each month.
NR 466.06(3) (3)Compliance methods. The emission limitation in sub. (2) shall be achieved by any of the following methods:
NR 466.06(3)(a) (a) Overall control of at least 92% of organic HAP used.
NR 466.06(3)(b) (b) Substitution of non-HAP materials for organic HAP.
NR 466.06(3)(c) (c) A combination of capture and control technologies and substitution of materials.
NR 466.06(4) (4)Compliance demonstration.
NR 466.06(4)(a)(a) Solvent recovery. Each owner or operator using a solvent recovery device to control emissions shall demonstrate compliance by showing that the HAP emission limitation is achieved by doing either of the following:
NR 466.06(4)(a)1. 1. Perform a liquid-liquid material balance for each month according to the following procedures:
NR 466.06(4)(a)1.a. a. Measure the mass of each ink, coating, varnish, adhesive, primer, solvent and other material used by the affected source during the month.
NR 466.06(4)(a)1.b. b. Determine the organic HAP content of each ink, coating, varnish, adhesive, primer, solvent and other material used by the affected source during the month following the procedure in s. NR 466.09 (2) (a).
NR 466.06(4)(a)1.c. c. Determine the volatile matter content, including water, of each ink, coating, varnish, adhesive, primer, solvent and other material used by the affected source during the month following the procedure in s. NR 466.09 (3) (a).
NR 466.06(4)(a)1.d. d. Install, calibrate, maintain and operate, according to the manufacturer's specifications, a device that indicates the cumulative amount of volatile matter recovered by the solvent recovery device on a monthly basis. The device shall be initially certified by the manufacturer to be accurate to within +2.0%.
NR 466.06(4)(a)1.e. e. Measure the amount of volatile matter recovered for the month.
NR 466.06(4)(a)1.f. f. Calculate the overall effective organic HAP control efficiency (Re) for the month using Equation 1. For the purposes of this calculation, the mass fraction of organic HAP present in the recovered volatile matter is assumed to be equal to the mass fraction of organic HAP present in the volatile matter used.
(Equation 1)
NR 466.06(4)(a)2. 2. Use continuous emission monitors, conduct an initial performance test of capture efficiency, and continuously monitor a site specific operating parameter to assure capture efficiency as specified in the following procedures:
NR 466.06(4)(a)2.a. a. Install continuous emission monitors to determine the total organic volatile matter mass flow rate at both the inlet to and the outlet from the control device, and calculate the percent efficiency (E) of the control device for each month.
NR 466.06(4)(a)2.b. b. Determine the percent capture efficiency (F) of the capture system according to s. NR 466.09 (5).
NR 466.06(4)(a)2.c. c. Calculate the overall effective organic HAP control efficiency (Re) achieved for each month using Equation 2.
(Equation 2)
NR 466.06(4)(a)2.d. d. Install, calibrate, operate and maintain the instrumentation necessary to measure continuously the site-specific operating parameter established in accordance with s. NR 466.10 (6) whenever a publication rotogravure printing press is operated.
NR 466.06(4)(a)2.e. e. Operate the capture device at an average value greater than, or less than, as appropriate, the operating parameter value established in accordance with s. NR 466.10 (6) for each 3-hour period.
NR 466.06(4)(b) (b) Oxidation. Each owner or operator using an oxidizer to control emissions shall demonstrate compliance by showing that the HAP emission limitation is achieved by doing either of the following:
NR 466.06(4)(b)1. 1. Demonstrate initial compliance through performance tests and continuing compliance through continuous monitoring according to the following procedures:
NR 466.06(4)(b)1.a. a. Determine the oxidizer destruction efficiency (E) using the procedure in s. NR 466.09 (4).
NR 466.06(4)(b)1.b. b. Determine the capture efficiency (F) using the procedure in s. NR 466.09 (5).
NR 466.06(4)(b)1.c. c. Calculate the overall effective organic HAP control efficiency (Re) achieved using Equation 2 in par. (a) 2. c.
NR 466.06(4)(b)1.d. d. Continuously monitor an appropriate oxidizer operating parameter in accordance with s. NR 466.10 (5), and continuously monitor an appropriate capture system monitoring parameter in accordance with s. NR 466.10 (6).
NR 466.06(4)(b)1.e. e. Operate the capture device at an average value greater than or less than, as appropriate, the operating parameter value established in accordance with s. NR 466.10 (6).
NR 466.06(4)(b)1.f. f. If an oxidizer other than a catalytic oxidizer is used, operate the oxidizer at an average combustion temperature for all 3-hour periods greater than or equal to the average combustion temperature established under s. NR 466.09 (4).
NR 466.06(4)(b)1.g. g. If a catalytic oxidizer is used, operate the oxidizer so that the average catalyst bed inlet temperature for all 3-hour periods is greater than or equal to the average catalyst bed inlet temperature established under s. NR 466.09 (4).
NR 466.06(4)(b)2. 2. Use continuous emission monitors, conduct an initial performance test of capture efficiency and continuously monitor a site specific operating parameter to assure capture efficiency in accordance with the requirements of par. (a) 2.
NR 466.06(4)(c) (c) Low HAP materials. . Each owner or operator demonstrating compliance without the use of a control device shall compare the mass of organic HAP used to the mass of volatile matter used each month, as specified in the following procedures:
NR 466.06(4)(c)1. 1. Measure the mass of each ink, coating, varnish, adhesive, primer, solvent and other material used in the affected source during the month.
NR 466.06(4)(c)2. 2. Determine the organic HAP content of each ink, coating, varnish, adhesive, primer, solvent and other material used during the month following the procedure in s. NR 466.09 (2) (a).
NR 466.06(4)(c)3. 3. Determine the volatile matter content, including water, of each ink, coating, varnish, adhesive, primer, solvent and other material used during the month following the procedure in s. NR 466.09 (3) (a).
NR 466.06(4)(d) (d) Compliance criteria.
NR 466.06(4)(d)1.1. Under par. (a) 1., the affected source is in compliance for the month with the emission limitation if Re is at least 92% for that month.
NR 466.06(4)(d)2. 2. Under par. (a) 2., the affected source is in compliance for the month with the emission limitation if Re is at least 92% for that month, and the capture device is operated at an average value greater than, or less than, as appropriate, the operating parameter value established in accordance with s. NR 466.10 (6) for each 3-hour period.
NR 466.06(4)(d)3. 3. Under par. (b) 1., the affected source is in initial compliance with the emission limitation if Re is at least 92%. The affected source is in continuing compliance with the emission limitation if par. (b) 1. e. and either par. (b) 1. f. or g. are satisfied.
NR 466.06(4)(d)4. 4. Under par. (b) 2., the affected source is in compliance for the month with the emission limitation if the criteria of subd. 2. are satisfied.
NR 466.06(4)(d)5. 5. Under par. (c), the affected source is in compliance for the month with the emission limitation if the mass of organic HAP used does not exceed 8% of the mass of volatile matter used.
NR 466.06 History History: Cr. Register, March, 2000, No. 531, eff. 4-1-00.
NR 466.07 NR 466.07Standards: product and packaging rotogravure and wide-web flexographic printing.
NR 466.07(1) (1)Compliance dates. Each owner or operator of any product and packaging rotogravure or wide-web flexographic printing affected source that is subject to the requirements of this chapter shall comply with this section on and after the compliance dates as specified in s. NR 466.08.
NR 466.07(2) (2)Emission limitations. The owner or operator of each product and packaging rotogravure or wide-web flexographic printing affected source shall limit organic HAP emissions to no more than any one of the following:
NR 466.07(2)(a) (a) Five percent of the organic HAP applied for the month.
NR 466.07(2)(b) (b) Four percent of the mass of inks, coatings, varnishes, adhesives, primers, solvents, reducers, thinners and other materials applied for the month.
NR 466.07(2)(c) (c) Twenty percent of the mass of solids applied for the month.
NR 466.07(2)(d) (d) A calculated equivalent allowable mass based on the organic HAP and solids contents of the inks, coatings, varnishes, adhesives, primers, solvents, reducers, thinners and other materials applied for the month.
NR 466.07(3) (3)Compliance methods. The owner or operator of each product and packaging rotogravure or wide-web flexographic printing affected source shall demonstrate compliance with sub. (2) according to one of the following procedures:
NR 466.07(3)(a) (a) Demonstrate that each ink, coating, varnish, adhesive, primer, solvent, diluent, reducer, thinner and other material applied during the month contains no more than 0.04 weight-fraction organic HAP, on an as-purchased basis, as determined in accordance with s. NR 466.09 (2) (b).
NR 466.07(3)(b) (b) Demonstrate that each ink, coating, varnish, adhesive, primer and other solids-containing material applied during the month contains no more than 0.04 weight-fraction organic HAP, on a monthly average as-applied basis, as determined in accordance with the following procedures:
NR 466.07(3)(b)1. 1. Determine the organic HAP content of each ink, coating, varnish, adhesive, primer, solvent, diluent, reducer, thinner and other material applied on an as-purchased basis in accordance with s. NR 466.09 (2) (b).
NR 466.07(3)(b)2. 2. Calculate the monthly average as-applied organic HAP content (Cahi ) of each ink, coating, varnish, adhesive, primer and other solids-containing material using Equation 3.
NR 466.07(3)(c) (c) Demonstrate that each ink, coating, varnish, adhesive, primer and other solids-containing material applied, contains no more than one of the following:
NR 466.07(3)(c)1. 1. 0.04 weight-fraction organic HAP on a monthly average as-applied basis, when determined in accordance with par. (b).
NR 466.07(3)(c)2. 2. 0.20 kg (0.20 lb) of organic HAP per kg (lb) of solids applied, on a monthly average as-applied basis, when determined in accordance with the following procedures:
NR 466.07(3)(c)2.a. a. Determine the as-applied solids content following the procedure in s. NR 466.09 (3) (b) of all materials which do not meet the requirements of subd.1.
NR 466.07(3)(c)2.b. b. Calculate the monthly average as-applied solids content of materials which are reduced, thinned or diluted prior to application, using Equation 4.
NR 466.07(3)(c)2.c. c. Calculate the as-applied organic HAP to solids ratio, Hsi, for all materials which do not meet the requirements of subd. 1., using Equation 5.
NR 466.07(3)(d) (d) Demonstrate that the monthly average as-applied organic HAP content, HL, of all materials applied is less than 0.04 kg (0.04 lb) HAP per kg (lb) of material applied, using Equation 6.
- See PDF for diagram PDF   (Equation 6)
NR 466.07(3)(e) (e) Demonstrate that the monthly average as-applied organic HAP content, HS, is less than 0.20 kg (0.20 lb) HAP per kg (lb) solids applied using Equation 7.
- See PDF for diagram PDF   (Equation 7)
NR 466.07(3)(f) (f) Demonstrate that the total monthly organic HAP applied, H, as determined using Equation 8, is less than the calculated equivalent allowable organic HAP, Ha, as determined under sub. (6).
- See PDF for diagram PDF   (Equation 8)
NR 466.07(3)(g) (g) Operate a capture system and control device and demonstrate an overall organic HAP control efficiency of at least 95% for each month. If the affected source operates more than one capture system or more than one control device, and has only always-controlled work stations, the owner or operator shall demonstrate compliance in accordance with the provisions of sub. (7) or (9). If the affected source operates one or more never-controlled work stations or one or more intermittently-controllable work stations, the owner or operator shall demonstrate compliance in accordance with the provisions of sub. (7). Otherwise, the owner or operator shall demonstrate compliance in accordance with the procedure in sub. (4) when emissions from the affected source are controlled by a solvent recovery device or the procedure in sub. (5) when emissions are controlled by an oxidizer.
NR 466.07(3)(h) (h) Operate a capture system and control device and limit the organic HAP emission rate to no more than 0.20 kg (0.20 lb) organic HAP emitted per kg (lb) solids applied as determined on a monthly average as-applied basis. If the affected source operates more than one capture system, more than one control device, one or more never-controlled work stations, or one or more intermittently-controllable work stations, the owner or operator shall demonstrate compliance in accordance with the provisions of sub. (7). Otherwise, the owner or operator shall demonstrate compliance following the procedure in sub. (4) when emissions from the affected source are controlled by a solvent recovery device or the procedure in sub. (5) when emissions are controlled by an oxidizer.
NR 466.07(3)(i) (i) Operate a capture system and control device and limit the organic HAP emission rate to no more than 0.04 kg (0.04 lb) organic HAP emitted per kg (lb) material applied as determined on a monthly average as-applied basis. If the affected source operates more than one capture system, more than one control device, one or more never-controlled work stations, or one or more intermittently-controllable work stations, then the owner or operator shall demonstrate compliance in accordance with the provisions of sub. (7). Otherwise, the owner or operator shall demonstrate compliance following the procedure in sub. (4) when emissions from the affected source are controlled by a solvent recovery device or the procedure in sub. (5) when emissions are controlled by an oxidizer.
NR 466.07(3)(j) (j) Operate a capture system and control device and limit the monthly organic HAP emissions to less than the allowable emissions as calculated in accordance with sub. (6). If the affected source operates more than one capture system, more than one control device, one or more never-controlled work stations, or one or more intermittently-controllable work stations, the owner or operator shall demonstrate compliance in accordance with the provisions of sub. (7). Otherwise, the owner or operator shall demonstrate compliance following the procedure in sub. (4) when emissions from the affected source are controlled by a solvent recovery device or the procedure in sub. (5) when emissions are controlled by an oxidizer.
NR 466.07(4) (4)Compliance demonstration for a solvent recovery device.
NR 466.07(4)(a)(a) To demonstrate the overall organic HAP control efficiency required under sub. (3) (g), or the organic HAP emission limitation requirements in sub. (3) (h) to (j), each owner or operator using a solvent recovery device to control emissions shall do one of the following:
NR 466.07(4)(a)1. 1. Perform a liquid-liquid material balance for each month according to the following procedures:
NR 466.07(4)(a)1.a. a. Measure the mass of each ink, coating, varnish, adhesive, primer, solvent and other material applied on the press or group of presses controlled by a common solvent recovery device during the month.
NR 466.07(4)(a)1.b. b. If demonstrating compliance with sub. (2) (b), (c) or (d), determine the organic HAP content of each ink, coating, varnish, adhesive, primer, solvent and other material applied during the month following the procedure in s. NR 466.09 (2) (b).
NR 466.07(4)(a)1.c. c. Determine the volatile matter content of each ink, coating, varnish, adhesive, primer, solvent and other material applied during the month following the procedure in s. NR 466.09 (3) (b).
NR 466.07(4)(a)1.d. d. If demonstrating compliance with sub. (2) (c) or (d), determine the solids content of each ink, coating, varnish, adhesive, primer, solvent and other material applied during the month following the procedure in s. NR 466.09 (3) (b).
NR 466.07(4)(a)1.e. e. Install, calibrate, maintain and operate according to the manufacturer's specifications, a device that indicates the cumulative amount of volatile matter recovered by the solvent recovery device on a monthly basis. The device shall be initially certified by the manufacturer to be accurate to within + 2.0%.
NR 466.07(4)(a)1.f. f. Measure the amount of volatile matter recovered for the month.
NR 466.07(4)(a)1.g. g. Calculate the volatile matter collection and recovery efficiency, Rv, using Equation 9.
Loading...
Loading...
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date the chapter was last published.