NR 465.35(2)(c)2.
2. If your actions were not consistent with your startup, shutdown and malfunction plan, you shall submit an immediate startup, shutdown and malfunction report as described in
subd. 2. a. and
b.
NR 465.35(2)(c)2.a.
a. You shall describe the actions taken during the event in a report delivered by facsimile, telephone or other means to the department within 2 working days after starting actions that are inconsistent with the plan.
NR 465.35(2)(c)2.b.
b. You shall submit a letter to the department within 7 working days after the end of the event, unless you have made alternative arrangements with the department as specified in
s. NR 460.09 (4) (e) 2. The letter shall contain the information specified in
s. NR 460.09 (4) (e) 2.
NR 465.35(3)
(3) What records must i keep? You shall collect and keep records of the data and information specified in this subsection. Failure to collect and keep these records is a deviation from the applicable standard.
NR 465.35(3)(a)
(a) A copy of each notification and report that you submitted to comply with this subchapter, and the documentation supporting each notification and report. If you are using the predominant activity alternative under
s. NR 465.33 (1) (c) 1., you shall keep records of the data and calculations used to determine the predominant activity. If you are using the facility-specific emission limit alternative under
s. NR 465.33 (1) (c) 2., you shall keep records of the data used to calculate the facility-specific emission limit for the initial compliance demonstration. You shall also keep records of any data used in each annual predominant activity determination and in the calculation of the facility-specific emission limit for each 12-month compliance period included in the semi-annual compliance reports.
NR 465.35(3)(b)
(b) A current copy of information provided by materials suppliers or manufacturers, such as manufacturer's formulation data, or test data used to determine the mass fraction of organic HAP and density for each coating, thinner and other additive, and cleaning material, and the mass fraction of coating solids for each coating. If you conducted testing to determine mass fraction of organic HAP, density or mass fraction of coating solids, you shall keep a copy of the complete test report. If you used information provided to you by the manufacturer or supplier of the material that was based on testing, you shall keep the summary sheet of results provided to you by the manufacturer or supplier. You are not required to obtain the test report or other supporting documentation from the manufacturer or supplier.
NR 465.35(3)(c)
(c) For each compliance period, the records specified in
subds. 1. to 4:
NR 465.35(3)(c)1.
1. A record of the coating operations on which you used each compliance option in
s. NR 465.33 (2) and the time periods, beginning and ending dates and times, for each option you used.
NR 465.35(3)(c)3.
3. For the emission rate without add-on controls option in
s. NR 465.33 (2) (b), a record of the calculation of the total mass of organic HAP emissions for the coatings, thinners and other additives, and cleaning materials used each month using Equations 1 and 1A to 1C of
s. NR 465.37 (2) and, if applicable, the calculation used to determine mass of organic HAP in waste materials according to
s. NR 465.37 (2) (e) 2.; the calculation of the total mass of coating solids used each month using Equation 2 of
s. NR 465.37 (2); and the calculation of each 12-month organic HAP emission rate using Equation 3 of
s. NR 465.37 (2).
NR 465.35(3)(c)4.a.
a. The calculation of the total mass of organic HAP emissions for the coatings, thinners and other additives, and cleaning materials used each month using Equations 1 and 1A to 1C of
s. NR 465.37 (2); and, if applicable, the calculation used to determine mass of organic HAP in waste materials according to
s. NR 465.37 (2) (e) 2.
NR 465.35(3)(c)4.c.
c. The calculation of the mass of organic HAP emission reduction by emission capture systems and add-on control devices using Equations 1 and 1A to 1D of
s. NR 465.38 (2) and Equations 2, 3 and 3A to 3C of
s. NR 465.38 (2), as applicable.
NR 465.35(3)(d)
(d) A record of the name and mass of each coating, thinner and other additive, and cleaning material used during each compliance period. If you are using the compliant material option in
s. NR 465.33 (2) (a) for all coatings at the source, you may maintain purchase records for each material used rather than a record of the mass used.
NR 465.35(3)(e)
(e) A record of the mass fraction of organic HAP for each coating, thinner and other additive, and cleaning material used during each compliance period.
NR 465.35(3)(f)
(f) A record of the mass fraction of coating solids for each coating used during each compliance period.
NR 465.35(3)(g)
(g) If you use an allowance in Equation 1 of
s. NR 465.37 (2) for organic HAP contained in waste materials sent to or designated for shipment to a treatment, storage and disposal facility (TSDF) according to
s. NR 465.37 (2) (e) 2., you shall keep records of the information specified in
subds. 1. to
3.
NR 465.35(3)(g)1.
1. The name and address of each TSDF to which you sent waste materials for which you use an allowance in Equation 1 of
s. NR 465.37 (2), a statement of which subparts under
40 CFR parts 262,
264,
265 and
266 apply to the facility; and the date of each shipment.
NR 465.35(3)(g)2.
2. Identification of the coating operations producing waste materials included in each shipment and the month or months in which you used the allowance for these materials in Equation 1 of
s. NR 465.37 (2).
NR 465.35(3)(g)3.
3. The methodology used in accordance with
s. NR 465.37 (2) (e) 2. to determine the total amount of waste materials sent to or the amount collected, stored and designated for transport to a TSDF each month; and the methodology to determine the mass of organic HAP contained in these waste materials. This shall include the sources for all data used in the determination, methods used to generate the data, frequency of testing or monitoring, and supporting calculations and documentation, including the waste manifest for each shipment.
NR 465.35(3)(h)
(h) You shall keep records of the date, time and duration of each deviation.
NR 465.35(3)(i)1.
1. For each deviation, a record of whether the deviation occurred during a period of startup, shutdown or malfunction.
NR 465.35(3)(i)3.
3. The records required to show continuous compliance with each operating limit specified in Table 1 of this subchapter that applies to you.
NR 465.35(3)(i)4.
4. For each capture system that is a PTE, the data and documentation you used to support a determination that the capture system meets the criteria in Method 204 in
40 CFR part 51, Appendix M, incorporated by reference in
s. NR 484.04 (9), for a PTE and has a capture efficiency of 100%, as specified in
s. NR 465.38 (6) (a).
NR 465.35(3)(i)5.
5. For each capture system that is not a PTE, the data and documentation you used to determine capture efficiency according to the requirements specified in
s. NR 465.38 (5) and
(6) (b) to
(e), including the records specified in
subd. 5. a. to
c. that apply to you.
NR 465.35(3)(i)5.a.
a. For a liquid-to-uncaptured gas protocol using a temporary total enclosure or building enclosure, records of the mass of total volatile hydrocarbon (TVH) as measured by Method 204A or 204F in
40 CFR part 51, Appendix M, incorporated by reference in
s. NR 484.04 (9), for each material used in the coating operation, and the total TVH for all materials used during each capture efficiency test run, including a copy of the test report. Records of the mass of TVH emissions not captured by the capture system that exited the temporary total enclosure or building enclosure during each capture efficiency test run, as measured by Method 204D or 204E in
40 CFR part 51, Appendix M, including a copy of the test report. Records documenting that the enclosure used for the capture efficiency test met the criteria in Method 204 in
40 CFR part 51, Appendix M for either a temporary total enclosure or a building enclosure.
NR 465.35(3)(i)5.b.
b. For a gas-to-gas protocol using a temporary total enclosure or a building enclosure, records of the mass of TVH emissions captured by the emission capture system as measured by Method 204B or 204C in
40 CFR part 51, Appendix M, incorporated by reference in
s. NR 484.04 (9), at the inlet to the add-on control device, including a copy of the test report. Records of the mass of TVH emissions not captured by the capture system that exited the temporary total enclosure or building enclosure during each capture efficiency test run, as measured by Method 204D or 204E in
40 CFR part 51, Appendix M, including a copy of the test report. Records documenting that the enclosure used for the capture efficiency test met the criteria in Method 204 in
40 CFR part 51, Appendix M for either a temporary total enclosure or a building enclosure.
NR 465.35(3)(i)5.c.
c. For an alternative protocol, records needed to document a capture efficiency determination using an alternative method or protocol as specified in
s. NR 465.38 (6) (e), if applicable.
NR 465.35(3)(i)6.
6. The records specified in
subd. 6. a. and
b. for each add-on control device organic HAP destruction or removal efficiency determination as specified in
s. NR 465.38 (7).
NR 465.35(3)(i)6.b.
b. Records of the coating operation conditions during the add-on control device performance test showing that the performance test was conducted under representative operating conditions.
NR 465.35(3)(i)7.
7. Records of the data and calculations you used to establish the emission capture and add-on control device operating limits as specified in
s. NR 465.38 (8) and to document compliance with the operating limits as specified in Table 1 of this subchapter.
NR 465.35(3)(i)8.
8. A record of the work practice plan required by
s. NR 465.33 (4) and documentation that you are implementing the plan on a continuous basis.
NR 465.35(4)
(4) In what form and for how long must i keep my records? NR 465.35(4)(a)(a) Your records shall be in a form suitable and readily available for expeditious review, according to
s. NR 460.09 (2) (a). Where appropriate, the records may be maintained as electronic spreadsheets or as a database.
NR 465.35(4)(b)
(b) As specified in
s. NR 460.09 (2) (a), you shall keep each record for 5 years following the date of each occurrence, measurement, maintenance, corrective action, report or record.
NR 465.35(4)(c)
(c) You shall keep each record on-site for at least 2 years after the date of each occurrence, measurement, maintenance, corrective action, report or record according to
s. NR 460.09 (2) (a). You may keep the records off-site for the remaining 3 years.
NR 465.35 History
History: CR 05-040: cr. Register February 2006 No. 602, eff. 3-1-06. NR 465.36
NR 465.36
Compliance requirements for the compliant material option. NR 465.36(1)
(1)
By what dates must i conduct the initial compliance demonstration? You shall complete the initial compliance demonstration for the initial compliance period according to the requirements in
sub. (2). The initial compliance period begins on the applicable compliance date specified in
s. NR 465.31 (4) and ends on the last day of the 12th month following the compliance date. If the compliance date occurs on any day other than the first day of a month, then the initial compliance period extends through that month plus the next 12 months. The initial compliance demonstration includes the calculations according to
sub. (2) and supporting documentation showing that during the initial compliance period, you used no coating with an organic HAP content that exceeded the applicable emission limit in
s. NR 465.33 (1), and that you used no thinners or other additives, or cleaning materials that contained organic HAP as determined according to
sub. (2) (a).
NR 465.36(2)
(2) How do i demonstrate initial compliance with the emission limits? You may use the compliant material option for any individual coating operation, for any group of coating operations in the affected source, or for all the coating operations in the affected source. You shall use either the emission rate without add-on controls option in
s. NR 465.33 (2) (b) or the emission rate with add-on controls option in
s. NR 465.33 (2) (c) for any coating operation in the affected source for which you do not use the compliant material option. To demonstrate initial compliance using the compliant material option, the coating operation or group of coating operations shall use no coating with an organic HAP content that exceeds the applicable emission limits in
s. NR 465.33 (1) and shall use no thinner or other additive, or cleaning material that contains organic HAP as determined according to
pars. (a) to
(d). Any coating operation for which you use the compliant material option is not required to meet the operating limits or work practice standards required in
s. NR 465.33 (3) and
(4). You shall conduct a separate initial compliance demonstration for each general use coating, thermoplastic olefin coating, automotive lamp coating, and assembled on-road vehicle coating affected source unless you are demonstrating compliance with a predominant activity or facility-specific emission limit as provided in
s. NR 465.33 (1) (c). If you are demonstrating compliance with a predominant activity or facility-specific emission limit, you shall demonstrate that all coating operations included in the predominant activity determination or calculation of the facility-specific emission limit comply with that limit. You shall meet all the requirements of this subsection. You shall use the procedures in
pars. (a) to
(d) on each coating, thinner and other additive, and cleaning material in the condition it is in when it is received from its manufacturer or supplier and prior to any alteration. You do not need to re-determine the organic HAP content of coatings, thinners and other additives, and cleaning materials that are reclaimed on-site, or reclaimed off-site if you have documentation showing that you received back the exact same materials that were sent off-site, and reused in the coating operation for which you use the compliant material option, provided these materials in their condition as received were demonstrated to comply with the compliant material option.
NR 465.36(2)(a)
(a) Determine the mass fraction of organic HAP for each material used. You shall determine the mass fraction of organic HAP for each coating, thinner and other additive, and cleaning material used during the compliance period by using one of the following 5 options:
NR 465.36(2)(a)1.
1. `Method 311.' You may use Method 311 in
40 CFR part 63, Appendix A, incorporated by
reference in
s. NR 484.04 (25), for determining the mass fraction of organic HAP. You shall use the procedures specified in
subd. 1. a. and
b. when performing a Method 311 test.
NR 465.36(2)(a)1.a.
a. Count each organic HAP that is measured to be present at 0.1% by mass or more for Occupational Safety and Health Administration (OSHA)-defined carcinogens as specified in
29 CFR 1910.1200(d)(4) and at 1.0% by mass or more for other compounds. Express the mass fraction of each organic HAP you count as a value truncated to 4 places after the decimal point.
NR 465.36 Note
Note: For example, if toluene, not an OSHA carcinogen, is measured to be 0.5% of the material by mass, you do not have to count it.
NR 465.36(2)(a)1.b.
b. Calculate the total mass fraction of organic HAP in the test material by adding up the individual organic HAP mass fractions and truncating the result to 3 places after the decimal point.
NR 465.36(2)(a)2.
2. `Method 24.' For coatings, you may use Method 24 in
40 CFR part 60, Appendix A,
incorporated by reference in
s. NR 484.04 (13),
to determine the mass fraction of nonaqueous volatile matter and use that value as a substitute for mass fraction of organic HAP. For reactive adhesives in which some of the HAP react to form solids and are not emitted to the atmosphere, you may use the alternative method contained in
40 CFR part 63, Subpart PPPP Appendix A, incorporated by reference in
s. NR 484.04 (24r), rather than Method 24. You may use the volatile fraction that is emitted, as measured by the alternative method in
40 CFR part 63, Subpart PPPP, Appendix A as a substitute for the mass fraction of organic HAP.
NR 465.36(2)(a)3.
3. `Alternative method.' You may use an alternative test method for determining the mass fraction of organic HAP once the administrator has approved it. You shall follow the procedure in
s. NR 460.06 (5) to submit an alternative test method for approval.
NR 465.36(2)(a)4.
4. `Information from the supplier or manufacturer of the material.' You may rely on information other than that generated by the test methods specified in
subds. 1. to
3., such as manufacturer's formulation data, if it represents each organic HAP that is present at 0.1% by mass or more for OSHA-defined carcinogens as specified in
29 CFR 1910.1200(d)(4) and at 1.0% by mass or more for other compounds. For reactive adhesives in which some of the HAP react to form solids and are not emitted to the atmosphere, you may rely on manufacturer's data that expressly states the organic HAP or volatile matter mass fraction content. If there is a disagreement between the manufacturer's data and results of a test conducted according to
subds. 1. to
3., then the test method results will take precedence unless, after consultation, you demonstrate to the satisfaction of the department that the formulation data are correct.
NR 465.36 Note
Note: For example, concerning which HAPs to include, if toluene (not an OSHA carcinogen) is 0.5% of the material by mass, you do not have to count it.
NR 465.36(2)(a)5.
5. `Solvent blends.' Solvent blends may be listed as single components for some materials in data provided by manufacturers or suppliers. Solvent blends may contain organic HAP which shall be counted toward the total organic HAP mass fraction of the materials. When test data and manufacturer's data for solvent blends are not available, you may use the default values for the mass fraction of organic HAP in these solvent blends listed in Table 2 or 3 of this subchapter. If you use the tables, you shall use the values in Table 2 for all solvent blends that match Table 2 entries according to the instructions for Table 2, and you may use Table 3 only if the solvent blends in the materials you use do not match any of the solvent blends in Table 2 and you know only whether the blend is aliphatic or aromatic. However, if the results of a test using Method 311 in
40 CFR part 63, Appendix A, incorporated by reference in
s. NR 484.04 (25), indicates higher values than those listed on Table 2 or 3, the Method 311 results will take precedence unless, after consultation, you demonstrate to the satisfaction of the department that the formulation data are correct.
NR 465.36(2)(b)
(b) Determine the mass fraction of coating solids for each coating. You shall determine the mass fraction of coating solids, in units of kg (lb) of coating solids per kg (lb) of coating, for each coating used during the compliance period by a test, by information provided by the supplier or the manufacturer of the material, or by calculation, as specified in
subds. 1. to
3.
NR 465.36(2)(b)1.
1. `Method 24.' Use Method 24 in
40 CFR part 60, Appendix A, incorporated by reference in
s. NR 484.04 (13), for determining the mass fraction of coating solids. For reactive adhesives in which some of the liquid fraction reacts to form solids, you may use the alternative method contained in
40 CFR part 63, Subpart PPPP, Appendix A, incorporated by reference in
s. NR 484.04 (24r), rather than Method 24, to determine the mass fraction of coating solids.
NR 465.36(2)(b)2.
2. `Alternative method.' You may use an alternative test method for determining the solids content of each coating once the administrator has approved it. You shall follow the procedure in
s. NR 460.06 (5) to submit an alternative test method for approval.
NR 465.36(2)(b)3.
3. `Information from the supplier or manufacturer of the material.' You may obtain the mass fraction of coating solids for each coating from the supplier or manufacturer. If there is disagreement between the supplier's or manufacturer's information and the test method results, then the test method results will take precedence unless, after consultation, you demonstrate to the satisfaction of the department that the formulation data are correct.
NR 465.36(2)(c)
(c) Calculate the organic HAP content of each coating. Calculate the organic HAP content of each coating used during the compliance period using Equation 1:
(Equation 1)
where:
Hc is the organic HAP content of the coating, kg (lb) of organic HAP emitted per kg (lb) of coating solids used
Wc is the mass fraction of organic HAP in the coating, kg (lb) of organic HAP per kg (lb) of coating, determined according to par. (a)
Sc is the mass fraction of coating solids, kg (lb) of coating solids per kg (lb) of coating, determined according to par. (b)
NR 465.36(2)(d)
(d) Compliance demonstration. The calculated organic HAP content for each coating used during the initial compliance period shall be less than or equal to the applicable emission limit in
s. NR 465.33 (1); and each thinner and other additive, and cleaning material used during the initial compliance period shall contain no organic HAP, determined according to
par. (a). You shall keep all records required by
s. NR 465.35 (3) and
(4). As part of the notification of compliance status required in
s. NR 465.35 (1), you shall identify any coating operation for which you used the compliant material option and submit a statement that the coating operation was in compliance with the emission limits specified in
s. NR 465.33 (1) during the initial compliance period because you used no coatings for which the organic HAP content exceeded the applicable emission limit in
s. NR 465.33 (1), and you used no thinners or other additives, or cleaning materials that contained organic HAP, determined according to the procedures in
par. (a).
NR 465.36(3)
(3) How do i demonstrate continuous compliance with the emission limits? NR 465.36(3)(a)(a) For each compliance period, to demonstrate continuous compliance, you shall use no coating for which the organic HAP content, determined using Equation 1 of
sub. (2), exceeds the applicable emission limit in
s. NR 465.33 (1), and use no thinner or other additive, or cleaning material that contains organic HAP, determined according to
sub. (2) (a). A compliance period consists of 12 months. Each month, after the end of the initial compliance period described in
sub. (1), is the end of a compliance period consisting of that month and the preceding 11 months. If you are complying with a facility-specific emission limit under
s. NR 465.33 (1) (c) 2., you shall also perform the calculation using Equation 1 in
s. NR 465.33 (1) (c) 2. on a monthly basis using the data from the previous 12 months of operation.
NR 465.36(3)(b)
(b) If you choose to comply with the emission limits in
s. NR 465.33 (1) by using the compliant material option, the use of any coating, thinner or other additive, or cleaning material that does not meet the criteria specified in
par. (a) is a deviation from the emission limits in
s. NR 465.33 (1) that shall be reported as specified in
s. NR 465.35 (1) (c) 6. and
(2) (a) 5.
NR 465.36(3)(c)
(c) As part of each semiannual compliance report required by
s. NR 465.35 (2), you shall identify the coating operations for which you used the compliant material option. If there were no deviations from the applicable emission limit in
s. NR 465.33 (1), submit a statement that the coating operations were in compliance with the emission limits during the reporting period because you used no coatings for which the organic HAP content exceeded the applicable emission limit in
s. NR 465.33 (1), and you used no thinner or other additive, or cleaning material that contained organic HAP, determined according to
sub. (2) (a).
NR 465.36 History
History: CR 05-040: cr. Register February 2006 No. 602, eff. 3-1-06. NR 465.37
NR 465.37
Compliance requirements for the emission rate without add-on controls option. NR 465.37(1)
(1)
By what date must i conduct the initial compliance demonstration? You shall complete the initial compliance demonstration for the initial compliance period according to the requirements of
sub. (2). The initial compliance period begins on the applicable compliance date specified in
s. NR 465.31 (4) and ends on the last day of the 12th month following the compliance date. If the compliance date occurs on any day other than the first day of a month, then the initial compliance period extends through the end of that month plus the next 12 months. You shall determine the mass of organic HAP emissions and mass of coating solids used each month and then calculate an organic HAP emission rate at the end of the initial compliance period. The initial compliance demonstration includes the calculations according to
sub. (2) and supporting documentation showing that during the initial compliance period the organic HAP emission rate was equal to or less than the applicable emission limit in
s. NR 465.33 (1).
NR 465.37(2)
(2) how do i demonstrate initial compliance with the emission limits? You may use the emission rate without add-on controls option for any individual coating operation, for any group of coating operations in the affected source, or for all the coating operations in the affected source. You shall use either the compliant material option in
s. NR 465.33 (2) (a) or the emission rate with add-on controls option in
s. NR 465.33 (2) (c) for any coating operation in the affected source for which you do not use the emission rate without add-on controls option. To demonstrate initial compliance using the emission rate without add-on controls option, the coating operation or group of coating operations shall meet the applicable emission limit in
s. NR 465.33 (1), but is not required to meet the operating limits or work practice standards in
s. NR 465.33 (3) and
(4). You shall conduct a separate initial compliance demonstration for each general use, TPO, automotive lamp and assembled on-road vehicle coating operation, unless you are demonstrating compliance with a predominant activity or facility-specific emission limit as provided in
s. NR 465.33 (1) (c). If you are demonstrating compliance with a predominant activity or facility-specific emission limit, you shall demonstrate that all coating operations included in the predominant activity determination or calculation of the facility-specific emission limit comply with that limit. You shall meet all the requirements of this subsection. When calculating the organic HAP emission rate according to this subsection, do not include any coatings, thinners or other additives, or cleaning materials used on coating operations for which you use the compliant material option in
s. NR 465.33 (2) (a) or the emission rate with add-on controls option in
s. NR 465.33 (2) (c). You do not need to redetermine the mass of organic HAP in coatings, thinners or other additives, or cleaning materials that have been reclaimed on-site, or reclaimed off-site if you have documentation showing that you received back the exact same materials that were sent off-site, and reused in the coating operation or operations for which you use the emission rate without add-on controls option. If you use coatings, thinners or other additives, or cleaning materials that have been reclaimed on-site, the amount of each used in a month may be reduced by the amount of each that is reclaimed. That is, the amount used may be calculated as the amount consumed to account for materials that are reclaimed.
NR 465.37(2)(a)
(a) Determine the mass fraction of organic HAP for each material. Determine the mass fraction of organic HAP for each coating, thinner and other additive, and cleaning material used during each month according to the requirements in
s. NR 465.36 (2) (a).
NR 465.37(2)(b)
(b) Determine the mass fraction of coating solids. Determine the mass fraction of coating solids, kg (lb) of coating solids per kg (lb) of coating, for each coating used during each month according to the requirements in
s. NR 465.36 (2) (b).
NR 465.37(2)(c)
(c) Determine the density of each material. Determine the density of each liquid coating, thinner, other additive and cleaning material used during each month from test results using ASTM D1475-98(2003), “Standard Test Method for Density of Liquid Coatings, Inks, and Related Products", incorporated by reference in
s. NR 484.10 (22), information from the supplier or manufacturer of the material, or reference sources providing density or specific gravity data for pure materials. If there is disagreement between ASTM D1475-98 (2003) and other information sources, the test results will take precedence unless, after consultation, you demonstrate to the satisfaction of the department that the formulation data are correct. If you purchase materials or monitor consumption by weight instead of volume, you do not need to determine material density. Instead, you may use the material weight in place of the combined terms for density and volume in Equations 1A, 1B, 1C and 2 of this subsection.
NR 465.37(2)(d)
(d) Determine the volume of each material used. Determine the volume, in liters or gallons, of each coating, thinner and other additive, and cleaning material used during each month by measurement or usage records. If you purchase materials or monitor consumption by weight instead of volume, you do not need to determine the volume of each material used. Instead, you may use the material weight in place of the combined terms for density and volume in Equations 1A, 1B, 1C and 2 of this subsection.
NR 465.37(2)(e)1.1. The mass of organic HAP emissions is the combined mass of organic HAP contained in all coatings, thinners and other additives, and cleaning materials used during each month minus the organic HAP in certain waste materials. Calculate the mass of organic HAP emissions using the following equations and the procedures in
subd. 2. if applicable:
(Equation 1)
where:
He is the total mass of organic HAP emissions during the month, kg (lb)
A is the total mass of organic HAP in the coatings used during the month, kg (lb), as calculated in Equation 1A of this subsection
B is the total mass of organic HAP in the thinners and other additives used during the month, kg (lb), as calculated in Equation 1B of this subsection