This is the preview version of the Wisconsin State Legislature site.
Please see http://docs.legis.wisconsin.gov for the production version.
NR 449.11(2)(a)(a) A list of the equipment installed for compliance,
NR 449.11(2)(b)(b) A description of the physical and functional characteristics of each piece of equipment,
NR 449.11(2)(c)(c) A description of the methods which have been incorporated into the standard operating procedures for measuring or calculating the emissions for which emission limits are prescribed in s. NR 449.07 (2) (a) 1. and (f) 1., and
NR 449.11(2)(d)(d) A statement that each piece of equipment is installed and that each piece of equipment and each procedure is being used.
NR 449.11 HistoryHistory: Renum. from NR 154.19 (6) (k) and am. Register, September, 1986, No. 369, eff. 10-1-86.
NR 449.12NR 449.12Semiannual report.
NR 449.12(1)(1)The owner or operator of any source subject to this chapter shall submit to the department on September 15 and March 15 of each year a report in writing containing the information required by this section.
NR 449.12(2)(2)The first semiannual report shall be submitted within 180 days of the initial startup date of a source on which construction or modification commenced after February 1, 1984.
NR 449.12(3)(3)Unless otherwise specified, the owner or operator shall use the Methods of 40 CFR part 61, Appendix B, incorporated by reference in s. NR 484.04 (23), to conduct emission tests as required by pars. (b) and (c), unless an equivalent or an alternative method has been approved by the department. If the department finds reasonable grounds to dispute the results obtained by an equivalent or alternative method, the department may require the use of a reference method. If the results of the reference and equivalent or alternative methods do not agree, the results obtained by the reference method prevail, and the department may notify the owner or operator that approval of the method previously considered to be equivalent or alternative is withdrawn.
NR 449.12(3)(a)(a) The owner or operator shall include in the report a record of any emissions which averaged over any hour period (commencing on the hour) are in excess of the emission limits prescribed in s. NR 449.04 (1) or (2), 449.05 (1) or 449.06 (1) (a), (2), (3) or (4), or for any control system to which reactor emissions are required to be ducted in s. NR 449.06 (1) (b) or to which fugitive emissions are required to be ducted in s. NR 449.07 (2) (a) 2., (b), (e), (f) 2. or (i) 2. The emissions shall be measured in accordance with s. NR 449.10.
NR 449.12(3)(b)(b) In polyvinyl chloride plants for which a stripping operation is used to attain the emission level prescribed in s. NR 449.06 (5), the owner or operator shall include in the report a record of the vinyl chloride content in the polyvinyl chloride resin. Method 107 of 40 CFR part 61, Appendix B, incorporated by reference in s. NR 484.04 (23), shall be used to determine vinyl chloride content in accordance with this paragraph.
NR 449.12(3)(b)1.1. If batch stripping is used, one representative sample of polyvinyl chloride resin shall be taken from each batch of each grade of resin immediately following the completion of the stripping operation and identified by resin type and grade and the date and time the batch is completed. The corresponding quantity of material processed in each stripper batch shall be recorded and identified by resin type and grade and the date and time the batch is completed.
NR 449.12(3)(b)2.2. If continuous stripping is used, one representative sample of polyvinyl chloride resin shall be taken for each grade of resin processed, whichever is more frequent. The sample shall be taken as the resin flows out of the stripper and identified by resin type and grade and the date and time the sample was taken. The corresponding quantity of material processed by each stripper over the time period represented by the sample during the 8-hour period shall be recorded and identified by resin type and grade and the date and time it represents.
NR 449.12(3)(b)3.3. The quantity of material processed by the stripper shall be determined on a dry solids basis and by a method submitted to and approved by the department.
NR 449.12(3)(b)4.4. At the prior request of the department, the owner or operator shall provide duplicates of the samples required in subds. 1. and 2.
NR 449.12(3)(b)5.5. The report to the department by the owner or operator shall include the vinyl chloride content found in each sample required by subds. 1. and 2., averaged separately for each type of resin, over each calendar day and weighted according to the quantity of each grade of resin processed by the stripper or strippers that calendar day, according to the following equation:
where:
ATi is the 24-hour average concentration of type Ti resin in ppm (dry weight basis)
QTi is the total production of type Ti resin over the 24-hour period in kilograms
Ti is the type of resin
MGi is the concentration of vinyl chloride in one sample of grade Gi resin in parts per million
PGi is the production of grade Gi resin represented by the sample in kilograms
Gi is the grade of resin (e.g., G1, G2 and G3)
n is the total number of grades of resin produced during the 24-hour period
NR 449.12(3)(b)6.6. Records of all data needed to furnish the information required by subd. 5. shall be retained at the source and made available for inspection by a department representative for a minimum of 3 years. The records shall contain:
NR 449.12(3)(b)6.a.a. The vinyl chloride content found in all the samples required in subds. 1. and 2., identified by the resin type and grade and the time and date of the sample, and
NR 449.12(3)(b)6.b.b. The corresponding quantity of polyvinyl chloride resin processed by the stripper or strippers identified by the resin type and grade and the time and date it represents.
NR 449.12(3)(c)(c) The owner or operator shall include in the report a record of the emissions from each reactor opening for which an emission limit is prescribed in s. NR 449.06 (1) (b). Emissions shall be determined in accordance with s. NR 449.09 (6) (e), except that emissions for each reactor are to be determined. For a reactor that is also used as a stripper, the determination may be made immediately following the stripping operation.
NR 449.12 HistoryHistory: Renum. from NR 154.19 (6) (l) and am. Register, September, 1986, No. 369, eff. 10-1-86; am. (3) (intro.) (a), (b) (intro.) and 5., Register, December, 1995, No. 480, eff. 1-1-96; am. (3) (b) 6. intro., Register, January, 1997, No. 493, eff. 2-1-97.
NR 449.13NR 449.13Recordkeeping. The owner or operator of any source subject to this chapter shall retain the information specified in this section at the source and make it available for inspection by a department representative for a minimum of 2 years.
NR 449.13(1)(1)A record of the leaks detected by the vinyl chloride monitoring system, as required by s. NR 449.07 (2) (h), including the concentrations of vinyl chloride measured, analyzed, and recorded by the vinyl chloride detector, the location of each measurement and the date and approximate time of each measurement.
NR 449.13(2)(2)A record of the leaks detected during routine monitoring with the portable hydrocarbon detector and the action taken to repair the leaks, as required by s. NR 449.07 (2) (h).
NR 449.13(3)(3)A record of emissions measured in accordance with s. NR 449.10.
NR 449.13(4)(4)A daily operating record for each polyvinyl chloride reactor, including pressure and temperatures.
NR 449.13 HistoryHistory: Renum. from NR 154.19 (6) (m) and am. Register, September, 1986, No. 369, eff. 10-1-86.
Loading...
Loading...
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date the chapter was last published.