NR 449.10(3)
(3) A daily span check shall be conducted for each vinyl chloride monitoring system used. For all of the emission sources listed in
sub. (1), except the one for which an emission limit is prescribed in
s. NR 449.04 (2), the daily span check shall be conducted with a concentration of vinyl chloride equal to 10 parts per million. For the emissions source for which an emission limit is prescribed in
s. NR 449.04 (2), the daily span check shall be conducted with a concentration of vinyl chloride which is determined to be equivalent to the emission limit for that source based on the emission test required by
s. NR 449.09. The calibration shall be done with:
NR 449.10(3)(a)
(a) A calibration gas mixture prepared from the gases specified in sections 5.2.1 and 5.2.2 and in accordance with section 7.1 of Method 106 of
40 CFR part 61, Appendix B, incorporated by reference in
s. NR 484.04 (23), or
NR 449.10(3)(b)
(b) A calibration gas cylinder standard containing the appropriate concentration of vinyl chloride. The gas composition of the calibration gas cylinder standard shall have been certified by the manufacturer. The manufacturer must have recommended a maximum shelf life for each cylinder so that the concentration does not change greater than plus or minus 5% from the certified value. The date of gas cylinder preparation, certified vinyl chloride concentration and recommended maximum shelf life must have been affixed to the cylinder before shipment from the manufacturer to the buyer. If a gas chromatograph is used as the vinyl chloride monitoring system, these gas mixtures may be directly used to prepare a chromatograph calibration curve as described in section 7.3 of Method 106 of
40 CFR part 61, Appendix B, incorporated by reference in
s. NR 484.04 (23). The requirements in sections 5.2.3.1 and 5.2.3.2 of Method 106 for certification of cylinder standards and for establishment and verification of calibration standards shall be followed.
NR 449.10 History
History: Renum. from NR 154.19 (6) (j) and am.
Register, September, 1986, No. 369, eff. 10-1-86; am. (3) (a) and (b),
Register, December, 1995, No. 480, eff. 1-1-96.
NR 449.11(1)
(1) The owner or operator of any source to which this chapter applies and on which construction or modification is commenced after February 1, 1984 shall notify the department in writing that the equipment and procedural specifications in
s. NR 449.07 (2) (a) to
(h) are being implemented.
NR 449.11(2)
(2) The statement shall be submitted to the department within 90 days of the initial startup date. The statement shall contain the information specified in this subsection.
NR 449.11(2)(b)
(b) A description of the physical and functional characteristics of each piece of equipment,
NR 449.11(2)(c)
(c) A description of the methods which have been incorporated into the standard operating procedures for measuring or calculating the emissions for which emission limits are prescribed in
s. NR 449.07 (2) (a) 1. and
(f) 1., and
NR 449.11(2)(d)
(d) A statement that each piece of equipment is installed and that each piece of equipment and each procedure is being used.
NR 449.11 History
History: Renum. from NR 154.19 (6) (k) and am.
Register, September, 1986, No. 369, eff. 10-1-86.
NR 449.12(1)
(1) The owner or operator of any source subject to this chapter shall submit to the department on September 15 and March 15 of each year a report in writing containing the information required by this section.
NR 449.12(2)
(2) The first semiannual report shall be submitted within 180 days of the initial startup date of a source on which construction or modification commenced after February 1, 1984.
NR 449.12(3)
(3) Unless otherwise specified, the owner or operator shall use the Methods of
40 CFR part 61, Appendix B, incorporated by reference in
s. NR 484.04 (23), to conduct emission tests as required by
pars. (b) and
(c), unless an equivalent or an alternative method has been approved by the department. If the department finds reasonable grounds to dispute the results obtained by an equivalent or alternative method, the department may require the use of a reference method. If the results of the reference and equivalent or alternative methods do not agree, the results obtained by the reference method prevail, and the department may notify the owner or operator that approval of the method previously considered to be equivalent or alternative is withdrawn.
NR 449.12(3)(b)
(b) In polyvinyl chloride plants for which a stripping operation is used to attain the emission level prescribed in
s. NR 449.06 (5), the owner or operator shall include in the report a record of the vinyl chloride content in the polyvinyl chloride resin. Method 107 of
40 CFR part 61, Appendix B, incorporated by reference in
s. NR 484.04 (23), shall be used to determine vinyl chloride content in accordance with this paragraph.
NR 449.12(3)(b)1.
1. If batch stripping is used, one representative sample of polyvinyl chloride resin shall be taken from each batch of each grade of resin immediately following the completion of the stripping operation and identified by resin type and grade and the date and time the batch is completed. The corresponding quantity of material processed in each stripper batch shall be recorded and identified by resin type and grade and the date and time the batch is completed.
NR 449.12(3)(b)2.
2. If continuous stripping is used, one representative sample of polyvinyl chloride resin shall be taken for each grade of resin processed, whichever is more frequent. The sample shall be taken as the resin flows out of the stripper and identified by resin type and grade and the date and time the sample was taken. The corresponding quantity of material processed by each stripper over the time period represented by the sample during the 8-hour period shall be recorded and identified by resin type and grade and the date and time it represents.
NR 449.12(3)(b)3.
3. The quantity of material processed by the stripper shall be determined on a dry solids basis and by a method submitted to and approved by the department.
NR 449.12(3)(b)4.
4. At the prior request of the department, the owner or operator shall provide duplicates of the samples required in
subds. 1. and
2.
NR 449.12(3)(b)5.
5. The report to the department by the owner or operator shall include the vinyl chloride content found in each sample required by
subds. 1. and
2., averaged separately for each type of resin, over each calendar day and weighted according to the quantity of each grade of resin processed by the stripper or strippers that calendar day, according to the following equation: -
See PDF for diagram
-
See PDF for table NR 449.12(3)(b)6.
6. Records of all data needed to furnish the information required by
subd. 5. shall be retained at the source and made available for inspection by a department representative for a minimum of 3 years. The records shall contain:
NR 449.12(3)(b)6.a.
a. The vinyl chloride content found in all the samples required in
subds. 1. and
2., identified by the resin type and grade and the time and date of the sample, and
NR 449.12(3)(b)6.b.
b. The corresponding quantity of polyvinyl chloride resin processed by the stripper or strippers identified by the resin type and grade and the time and date it represents.
NR 449.12(3)(c)
(c) The owner or operator shall include in the report a record of the emissions from each reactor opening for which an emission limit is prescribed in
s. NR 449.06 (1) (b). Emissions shall be determined in accordance with
s. NR 449.09 (6) (e), except that emissions for each reactor are to be determined. For a reactor that is also used as a stripper, the determination may be made immediately following the stripping operation.
NR 449.12 History
History: Renum. from NR 154.19 (6) (l) and am.
Register, September, 1986, No. 369, eff. 10-1-86; am. (3) (intro.) (a), (b) (intro.) and 5.,
Register, December, 1995, No. 480, eff. 1-1-96
; am. (3) (b) 6. intro.,
Register, January, 1997, No. 493, eff. 2-1-97.
NR 449.13
NR 449.13 Recordkeeping. The owner or operator of any source subject to this chapter shall retain the information specified in this section at the source and make it available for inspection by a department representative for a minimum of 2 years.
NR 449.13(1)
(1) A record of the leaks detected by the vinyl chloride monitoring system, as required by
s. NR 449.07 (2) (h), including the concentrations of vinyl chloride measured, analyzed, and recorded by the vinyl chloride detector, the location of each measurement and the date and approximate time of each measurement.
NR 449.13(2)
(2) A record of the leaks detected during routine monitoring with the portable hydrocarbon detector and the action taken to repair the leaks, as required by
s. NR 449.07 (2) (h).
NR 449.13(4)
(4) A daily operating record for each polyvinyl chloride reactor, including pressure and temperatures.
NR 449.13 History
History: Renum. from NR 154.19 (6) (m) and am.
Register, September, 1986, No. 369, eff. 10-1-86.