NR 445.09(4)(a)3.c. c. Submit in writing to the department no later than January 31, 2011 a confirmation that the engine ceased operating on or before December 31, 2010.
NR 445.09(4)(b) (b) An owner or operator complying with an emission rate requirement in sub. (3) (a) 3. or 4. shall achieve compliance and submit all of the information in par. (a) 1. a. to L. in writing to the department no later than 10 calendar days after startup. A copy of the information shall also be maintained at the location where the engine is operated.
NR 445.09(4)(c) (c) An owner or operator complying with the best available control technology requirement in sub. (3) (a) 3. or 4., or a facility constructed or last modified after July 1, 2004, subject to sub. (3) (c), shall submit information describing how the best available control technology requirement will be met in a permit application in accordance with s. NR 406.03. Compliance with the best available control technology requirement shall be achieved and demonstrated in accordance with the permit.
NR 445.09 Note Note: Section NR 406.03 requires that owners or operators receive a construction permit prior to commencing operation of the source.
NR 445.09(4)(d) (d) The owner or operator of a facility constructed or last modified before July 1, 2004, subject to sub. (3) (c) shall do both of the following:
NR 445.09(4)(d)1. 1. Meet the schedule in s. NR 445.08 (6) (c) 1. and 2.
NR 445.09(4)(d)2. 2. Submit information describing how the best available control technology requirement will be met on the application forms required for an operation permit, an amendment to an application, renewal of the operation permit, or for a significant revision under s. NR 407.13, as applicable.
NR 445.09(4)(e) (e) Any submission made under this subsection shall be signed by the responsible official designated by the owner or operator of source for this purpose, with a dated statement that the information submitted is accurate to the best of the responsible official's knowledge and belief and that all of the requirements of this section have been met.
NR 445.09 Note Note: The address for submission of information under pars. (a) and (b) is:
Wisconsin Department of Natural Resources
Bureau of Air Management
PO Box 7921
Madison WI 53707-7921
Attention: Compression Ignition Engine Notification.
Application forms for pars. (c) and (d) may be obtained from, and submitted to:
Wisconsin Department of Natural Resources
Bureau of Air Management
PO Box 7921
Madison WI 53707-7921
Attention: Construction Permit (or) Attention: Operation Permit (as appropriate).
NR 445.09(5) (5)Test methods and procedures.
NR 445.09(5)(a)(a) An owner or operator choosing to comply with the 85% control requirement of sub. (3) (a) 1. shall, for each engine, comply with the requirements of ss. NR 439.06 and 439.07. The particulate matter emission reduction across a control device shall be determined by the following equation:
% reduction = 100 x (baseline emissions – controlled emissions)/(baseline emissions)
NR 445.09(5)(b) (b) Testing under par. (a) shall be conducted prior to the submission deadline in sub. (4) (a) 2. Subsequent testing and notification shall be conducted whenever the particulate matter emission control device used to achieve the 85% emission reduction is replaced. The department shall be notified of the results of subsequent tests in writing no later than 60 calendar days after the completion of the test.
NR 445.09(6) (6)Recordkeeping. In addition to meeting the recordkeeping requirements of s. NR 439.04 (1) and (2), an owner or operator shall:
NR 445.09(6)(a) (a) Keep records of maintenance performed on any particulate matter emission control device used to comply with sub. (3).
NR 445.09(6)(b) (b) For any engine that stays or that is intended to stay in a single location for any 12 consecutive month period, keep the following records:
NR 445.09(6)(b)1. 1. The amount of fuel oil combusted on a monthly basis for any engine not using a certified control device.
NR 445.09(6)(b)2. 2. The power rating and days of operation of any CI engine used to substitute power under sub. (1) (d).
NR 445.09(6)(b)3. 3. The cost of rebuilding any CI engine on a monthly basis.
NR 445.09 History History: CR 02-097: cr. Register June 2004 No. 582, eff. 7-1-04; CR 07-076: am. (1) (e) 1. (intro.) and 2. (intro.) Register July 2008 No. 631, eff. 8-1-08; CR 15-005: am. (1) (c), (2), cr. (3) (d) Register November 2015 No. 719, eff. 12-1-15.
NR 445.10 NR 445.10 Control and compliance requirements for the handling and storage of coal.
NR 445.10(1) (1) Applicability. This section applies to the owner or operator of any stationary source that handles or stores 1,000 tons or more of coal in any 12 consecutive month period.
NR 445.10(2) (2)Requirements for outdoor fugitive coal dust emissions. No later than June 30, 2007, the owner or operator of a source that handles coal or maintains a coal storage pile shall achieve compliance with this section by doing all of the following:
NR 445.10(2)(a) (a) Having the ability to control, in a timely manner, outdoor fugitive coal dust emissions in an effort to prevent emissions off the source property.
NR 445.10 Note Note: Examples of measures that would meet the ability to control requirement include active measures such as the application of water or chemical dust suppressants, passive measures such as the use of enclosed delivery or handling systems or solid fencing, or access to third-parties to provide dust suppression, as appropriate. The intent of this section is to allow facilities that suppress dust using water to manage the amount of water applied to avoid potential boiler, handling, or other operational problems, as long as there is sufficient dust control so as not to cause excessive outdoor fugitive coal dust emissions.
NR 445.10(2)(b) (b) Developing and implementing a plan to control outdoor fugitive coal dust emissions in an effort to prevent emissions off the source property. The plan shall include all of the following:
NR 445.10(2)(b)1. 1. Identification of all sources of outdoor fugitive coal dust emissions from coal handling and coal storage piles on the source property.
NR 445.10(2)(b)2. 2. A description of the measures that can be taken to control, in a timely manner, outdoor fugitive coal dust emissions from all sources identified under subd. 1. under the following conditions:
NR 445.10(2)(b)2.a. a. Routine operations.
NR 445.10(2)(b)2.b. b. Periods of high activity.
NR 445.10(2)(b)2.c. c. Periods of increased probability of outdoor fugitive dust emissions.
NR 445.10(2)(b)2.d. d. When equipment used to control outdoor fugitive coal dust emissions malfunctions.
NR 445.10 Note Note: Suppliers of coal may want to consult with users in development of the plan to ensure that use of the controls provided for in par. (a) does not result in operational problems at a source combusting coal.
Examples of periods of high activity include periods when the daily handling of coal is much greater than usual, such as when unloading a large number of coal shipments at the close of the shipping season. Examples of periods of increased probability of fugitive coal dust emissions include periods or a combination of periods of drought, freezing weather, or forecasts of high winds exceeding 25 miles per hour.
NR 445.10(2)(c) (c) Keeping records of actions taken to control outdoor fugitive coal dust emissions in accordance with s. NR 439.04 (2).
NR 445.10(2)(d) (d) Keeping a copy of the plan and records of all actions taken at the facility for inspection upon request.
NR 445.10(3) (3)Requirements for non-fugitive coal dust emissions to the ambient air. No later than June 30, 2007, the owner or operator subject to this section shall, for any non-fugitive source of coal dust emissions exhausted through a fabric filter to the ambient air, do one of the following:
NR 445.10(3)(a) (a) Limit visible emissions from each source to 10% opacity.
NR 445.10(3)(b) (b) Limit the quantity, concentration or duration of potential to emit emissions of respirable coal dust from all sources so that ambient air concentration off the source property is less than 21.6 mg/m3 for any 24 hour averaging period. The owner or operator may rely on information generated by either the EPA screening or refined dispersion model to demonstrate meeting the concentration in this paragraph.
NR 445.10(4) (4)Compliance certification. No later than June 30, 2007, the owner or operator of a source subject to this section shall certify the source's compliance status. An owner or operator of a source that has requirements at least as stringent as the requirements in sub. (2) or (3) in a permit or order may so state in his or her certification.
NR 445.10 Note Note: This is a one-time certification. Certification forms may be obtained from, and submitted to:
Wisconsin Department of Natural Resources
Bureau of Air Management
PO Box 7921
Madison WI 53707-7921
Attention: NR 445 Certification form for handling and storage of coal.
NR 445.10 History History: CR 02-097: cr. Register June 2004 No. 582, eff. 7-1-04.
NR 445.11 NR 445.11 Compliance requirements for sources of incidental emissions.
NR 445.11(1) (1) The owner or operator of a facility described by a standard industrial classification code listed in Table D, as described in the Standard Industrial Classification Manual, 1987, incorporated by reference in s. NR 484.05 (1), or that has actual annual emissions of less than 5 tons of particulate matter and less than 3 tons of volatile organic compounds, shall meet the requirements of subs. (2) to (4) if any of the following apply:
NR 445.11(1)(a) (a) The facility includes operation of one or more of the following processes:
NR 445.11(1)(a)1. 1. A compression ignition internal combustion engine with rated brake power greater than 100 horsepower used as a power source.
NR 445.11(1)(a)2. 2. Any expected source of chlorinated dioxins, furans or PCBs.
NR 445.11(1)(a)3. 3. Sludge incineration.
NR 445.11(1)(a)4. 4. Chrome electroplating.
NR 445.11(1)(a)5. 5. Gasoline dispensing.
NR 445.11(1)(a)6. 6. Manufacture or treatment of a pesticide, rodenticide, insecticide, herbicide or a fungicide resulting in an emission of a hazardous air contaminant listed in Table B of s. NR 445.07.
NR 445.11(1)(a)7. 7. Manufacture or treatment of a pharmaceutical resulting in an emission of a hazardous air contaminant listed in Table C of s. NR 445.07.
NR 445.11(1)(a)8. 8. Solid, hazardous or medical waste incineration.
NR 445.11(1)(b) (b) The presence of one or more of the substances in Table E at the facility is indicated by one of the following:
NR 445.11(1)(b)1. 1. The substance is listed on an approved material safety data sheet or is otherwise brought into the facility.
NR 445.11(1)(b)2. 2. The substance is reasonably expected to be created at the facility through a combustion process or manufacturing process, or through the treatment of raw materials or waste.
NR 445.11(2)(a)(a) The owner or operator of a process identified under sub. (1) (a) 1. shall meet the applicable requirements in s. NR 445.09 for that process.
NR 445.11(2)(b) (b) The owner or operator of a process identified under sub. (1) (a) 2. to 5. shall meet the applicable requirements in s. NR 445.07 (1) for any hazardous air contaminants listed in Table A of s. NR 445.07 for that process.
NR 445.11 Note Note: The department will develop a list of the hazardous air contaminants it has determined to be potentially emitted from the processes listed in sub. (1) (a) 2. to 5. This list may be obtained by calling the Environmental Analysis and Outreach Section of the Bureau of Air Management at 608-266-7718.
NR 445.11(2)(c) (c) The owner or operator of a process identified under sub. (1) (a) 6. shall meet the applicable requirements in s. NR 445.07 (2) for any hazardous air contaminants listed in Table B of s. NR 445.07 for that process.
NR 445.11(2)(d) (d) The owner or operator of a process identified under sub. (1) (a) 7. shall meet the applicable requirements in s. NR 445.07 (3) for any hazardous air contaminants listed in Table C of s. NR 445.07 for that process.
NR 445.11(2)(e) (e) The owner or operator of a process identified under sub. (1) (a) 8. shall meet the applicable requirements in s. NR 445.07 (4) for that process.
NR 445.11(3) (3) The owner or operator of a facility meeting the criteria in sub. (1) (b) shall meet the applicable requirements in s. NR 445.07 (1) for any hazardous air contaminants listed in Table A of s. NR 445.07.
NR 445.11(4) (4) The owner or operator subject to sub. (2) or (3) shall do both of the following:
NR 445.11(4)(a) (a) Achieve compliance using the procedures allowed under s. NR 445.08 (2), (3) (a) or (b) or 445.09 (4).
NR 445.11(4)(b) (b) Meet the applicable compliance schedule under s. NR 445.08 (6).
NR 445.11 Note Note: Owners and operators of sources affected by this section should refer to chs. NR 406, 407 and 438 to determine whether there are applicable requirements in those chapters for hazardous air contaminants identified under this section. - See PDF for table PDF
NR 445.11 Note Note: Conversion tables to match 1987 SIC codes to 1997 NAICS codes can be found at http://www.census.gov/epcd/www/drnaics.htm. - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF
NR 445.11 History History: CR 02-097: cr. Register June 2004 No. 582, eff. 7-1-04; CR 07-076: am. Tables D and E Register July 2008 No. 631, eff. 8-1-08; reprinted to insert line numbers per CR 07-076 Register August 2008 No. 632.
NR 445.12 NR 445.12 Variances.
NR 445.12(1)(1) Criteria for approval. The owner or operator of a source subject to this chapter may apply for and the department may approve a variance from any of the provisions identified in pars. (a) and (b) if the applicant demonstrates to the satisfaction of the department that applicable provisions are met as follows:
NR 445.12(1)(a) (a) An applicant for a variance from the LAER control requirements in s. NR 445.07 (1) (c), (2), (3) or (4) shall demonstrate all of the following to the satisfaction of the department:
NR 445.12(1)(a)1. 1. Compliance with the LAER control requirement for which the variance has been requested would be economically infeasible.
NR 445.12(1)(a)2. 2. Residual emissions of the hazardous air contaminant in question would not cause significant harm to the environment or public health.
NR 445.12(1)(a)3. 3. The source's emissions would be controlled to a level that is the best available control technology.
NR 445.12(1)(b) (b) An applicant for a variance from the emission limitation of s. NR 445.07 (1) (a) for a contaminant having a standard based on an annual time period shall demonstrate all of the following to the satisfaction of the department:
NR 445.12(1)(b)1. 1. All direct or portable sources owned or operated in the state by the owner or operator of the air contaminant source for which a variance is requested are in, or are on a schedule for, compliance with all other applicable requirements of chs. NR 400 to 499.
NR 445.12(1)(b)2. 2. The emission limitation from which variance is sought is technologically or economically infeasible to meet due to conditions or special circumstances at the source, including adverse environmental or energy impacts.
NR 445.12(1)(b)3. 3. Residual emissions of the hazardous air contaminant would not cause significant harm to public health.
NR 445.12(1)(b)4. 4. Good faith efforts have been made to comply with s. NR 445.07 (1) (a) and all reasonably available alternative operating procedures and interim control measures to minimize emissions of the hazardous air contaminant will be utilized during the duration of the variance.
NR 445.12(2) (2)Consultation. The department shall consult with the department of health services to determine that residual emissions would not cause significant harm under sub. (1) (a) 2. or (b) 3. prior to establishing an emission limitation in a permit or order under this section.
NR 445.12(3) (3)Application forms. Application for a variance under this section shall be submitted on the application forms required for a construction permit, an operation permit, an amendment to an application, renewal of the operation permit, or for a significant revision under s. NR 407.13, as applicable.
NR 445.12 Note Note: Application forms for sub. (3) may be obtained from, and submitted to, the regional and area offices of the department or:
Wisconsin Department of Natural Resources
Bureau of Air Management
PO Box 7921
Madison WI 53707-7921
Attention: NR 445 Variance Applications.
Loading...
Loading...
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date the chapter was last published.