NR 440.75(7)(b)
(b) Each owner or operator seeking to comply with
sub. (3) (b) 2. c. using an enclosed combustor shall calibrate, maintain and operate according to the manufacturer's specifications, the following equipment:
NR 440.75(7)(b)1.
1. A temperature monitoring device equipped with a continuous recorder and having a minimum accuracy of
± 1% of the temperature being measured, expressed in degrees Celsius, or
± 0.5 degrees Celsius, whichever is greater. A temperature monitoring device is not required for boilers or process heaters with design heat input capacity equal to or greater than 44 megawatts.
NR 440.75(7)(b)2.
2. A device that records flow to or bypass of the control device. The owner or operator shall do one of the following:
NR 440.75(7)(b)2.a.
a. Install, calibrate and maintain a gas flow rate measuring device that shall record the flow to the control device at least every 15 minutes.
NR 440.75(7)(b)2.b.
b. Secure the bypass line valve in the closed position with a car-seal or a lock-and-key type configuration. A visual inspection of the seal or closure mechanism shall be performed at least once every month to ensure that the valve is maintained in the closed position and that the gas flow is not diverted through the bypass line.
NR 440.75(7)(c)
(c) Each owner or operator seeking to comply with
sub. (3) (b) 2. c. using an open flare shall install, calibrate, maintain and operate according to the manufacturer's specifications the following equipment:
NR 440.75(7)(c)1.
1. A heat sensing device, such as an ultraviolet beam sensor or thermocouple, at the pilot light or the flame itself to indicate the continuous presence of a flame.
NR 440.75(7)(c)2.
2. A device that records flow to or bypass of the flare. The owner or operator shall do one of the following:
NR 440.75(7)(c)2.a.
a. Install, calibrate and maintain a gas flow rate measuring device that shall record the flow to the control device at least every 15 minutes.
NR 440.75(7)(c)2.b.
b. Secure the bypass line valve in the closed position with a car-seal or a lock-and-key type configuration. A visual inspection of the seal or closure mechanism shall be performed at least once every month to ensure that the valve is maintained in the closed position and that the gas flow is not diverted through the bypass line.
NR 440.75(7)(d)
(d) Each owner or operator seeking to demonstrate compliance with
sub. (3) (b) 2. c. using a device other than an open flare or an enclosed combustor shall provide information satisfactory to the department as provided in
sub. (3) (b) 2. a. 2) describing the operation of the control device, the operating parameters that would indicate proper performance, and appropriate monitoring procedures. The department shall review the information and either approve it or request that additional information be submitted. The department may specify additional appropriate monitoring procedures.
NR 440.75(7)(e)
(e) Each owner or operator seeking to install a collection system that does not meet the specifications in
sub. (10), or seeking to monitor alternative parameters to those required by
subs. (4) to
(6) or this subsection, shall provide information satisfactory to the department as provided in
sub. (3) (b) 2. a. 2) and 3) describing the design and operation of the collection system, the operating parameters that would indicate proper performance, and appropriate monitoring procedures. The department may specify additional appropriate monitoring procedures.
NR 440.75(7)(f)
(f) Each owner or operator seeking to demonstrate compliance with
sub. (6) (c) shall monitor surface concentrations of methane according to the instrument specifications and procedures provided in
sub. (6) (d). Any closed landfill that has no monitored exceedances of the operational standard in 3 consecutive quarterly monitoring periods may skip to annual monitoring. Any methane reading of 500 ppm or more above background detected during the annual monitoring shall return the frequency for that landfill to quarterly monitoring.
NR 440.75(8)(a)
(a) Each owner or operator subject to the requirements of this section shall do all of the following:
NR 440.75(8)(a)1.
1. Submit to the department an initial design capacity report which fulfills the requirements of the notification of the date construction is commenced as required under
s. NR 440.07 (1) (a) no later than one of the following:
NR 440.75(8)(a)1.a.
a. June 10, 1996, for landfills that commenced construction, modification or reconstruction on or after May 30, 1991 but before March 12, 1996.
NR 440.75(8)(a)1.b.
b. Ninety days after the date of commenced construction, modification or reconstruction for landfills that commence construction, modification or reconstruction on or after March 12, 1996.
NR 440.75(8)(a)2.
2. Ensure that the initial design capacity report submitted under
subd. 1. contains the following information:
NR 440.75(8)(a)2.a.
a. A map or plot of the landfill, providing the size and location of the landfill, and identifying all areas where solid waste may be landfilled according to an operating license issued under s.
289.31, Stats., by the department.
NR 440.75(8)(a)2.b.
b. The maximum design capacity of the landfill. Where the maximum design capacity is specified in an operating license issued under s.
289.31, Stats., by the department, a copy of the operating license specifying the maximum design capacity may be submitted as part of the report. If the maximum design capacity of the landfill is not specified in the operating license, the maximum design capacity shall be calculated using good engineering practices. The calculations shall be provided, along with the relevant parameters, as part of the report. The department may request other reasonable information as may be necessary to verify the maximum design capacity of the landfill.
NR 440.75(8)(a)3.
3. Submit an amended design capacity report to the department providing notification of an increase in the design capacity of the landfill, within 90 days of an increase in the maximum design capacity of the landfill to or above 2.5 million megagrams and 2.5 million cubic meters. This increase in design capacity may result from an increase in the volume of the landfill allowed in an operating license issued under s.
289.31, Stats., by the department, or an increase in the density as documented in the annual recalculation required in
sub. (9) (h).
NR 440.75(8)(b)1.1. Each owner or operator subject to the requirements of this section shall submit an NMOC emission rate report to the department initially and annually thereafter, except as provided for in
subds. 2. and
4. The department may request additional information as may be necessary to verify the reported NMOC emission rate. The NMOC emission rate report shall contain an annual or 5-year estimate of the NMOC emission rate calculated using the formula and procedures provided in
sub. (5) (a) or
(b), as applicable. The initial NMOC emission rate report may be combined with the initial design capacity report required in
par. (a) 1. and shall be submitted no later than one of the following:
NR 440.75(8)(b)1.a.
a. June 10, 1996, for landfills that commenced construction, modification or reconstruction on or after May 30, 1991, but before March 12, 1996.
NR 440.75(8)(b)1.b.
b. Ninety days after the date of commenced construction, modification or reconstruction for landfills that commence construction, modification or reconstruction on or after March 12, 1996.
NR 440.75(8)(b)2.
2. If the estimated NMOC emission rate as reported in the annual report to the department is less than 50 megagrams per year in each of the next 5 consecutive years, the owner or operator may elect to submit an estimate of the NMOC emission rate for the next 5-year period in lieu of the annual report. This estimate shall include the current amount of solid waste in-place and the estimated waste acceptance rate for each year of the 5 years for which an NMOC emission rate is estimated. All data and calculations upon which this estimate is based shall be provided to the department. This estimate shall be revised at least once every 5 years. If the actual waste acceptance rate exceeds the estimated waste acceptance rate in any year reported in the 5-year estimate, a revised 5-year estimate shall be submitted to the department. The revised estimate shall cover the 5-year period beginning with the year in which the actual waste acceptance rate exceeded the estimated waste acceptance rate.
NR 440.75(8)(b)3.
3. The NMOC emission rate report shall include all the data, calculations, sample reports and measurements used to estimate the annual or 5-year emissions.
NR 440.75(8)(b)4.
4. Each owner or operator subject to the requirements of this section is exempted from the requirements of
subds. 1. to
3., after the installation of a collection and control system in compliance with
sub. (3) (b) 2., during the time the collection and control system is in operation and in compliance with
subs. (4) and
(6).
NR 440.75(8)(c)
(c) Each owner or operator subject to the provisions of
sub. (3) (b) 2. a. shall submit a collection and control system design plan to the department within one year of the first report required under
par. (b) in which the emission rate equals or exceeds 50 megagrams per year, except as follows:
NR 440.75(8)(c)1.
1. If the owner or operator elects to recalculate the NMOC emission rate after Tier 2 NMOC sampling and analysis as provided in
sub. (5) (a) 3. and the resulting rate is less than 50 megagrams per year, annual periodic reporting shall be resumed, using the Tier 2 determined site-specific NMOC concentration, until the calculated emission rate is equal to or greater than 50 megagrams per year or the landfill is closed. The revised NMOC emission rate report, with the recalculated emission rate based on NMOC sampling and analysis, shall be submitted within 180 days of the first calculated exceedance of 50 megagrams per year.
NR 440.75(8)(c)2.
2. If the owner or operator elects to recalculate the NMOC emission rate after determining a site-specific methane generation rate constant, k, as provided in Tier 3 in
sub. (5) (a) 4., and the resulting NMOC emission rate is less than 50 megagrams per year, annual periodic reporting shall be resumed. The resulting site-specific methane generation rate constant, k, shall be used in the emission rate calculation until the time the emissions rate calculation results in an exceedance. The revised NMOC emission rate report based on the provisions of
sub. (5) (a) 4. and the resulting site-specific methane generation rate constant, k, shall be submitted to the department within one year of the first calculated emission rate exceeding 50 megagrams per year.
NR 440.75(8)(d)
(d) Each owner or operator of a controlled landfill shall submit a closure report to the department within 30 days of waste acceptance cessation. The department may request additional information as may be necessary to verify that permanent closure has taken place in accordance with the requirements of
40 CFR 258.60. If a closure report has been submitted to the department, no additional wastes may be placed into the landfill without filing a notification of modification as described under
s. NR 440.07 (1) (d).
NR 440.75(8)(e)1.1. Each owner or operator of a controlled landfill shall submit an equipment removal report to the department 30 days prior to removal or cessation of operation of the control equipment. The equipment removal report shall contain all of the following items:
NR 440.75(8)(e)1.b.
b. A copy of the initial performance test report demonstrating that the 15 year minimum control period has expired.
NR 440.75(8)(e)1.c.
c. Dated copies of 3 successive NMOC emission rate reports demonstrating that the landfill is no longer producing 50 megagrams or greater of NMOC per year.
NR 440.75(8)(e)2.
2. The department may request additional information as may be necessary to verify that all of the conditions for removal in
sub. (3) (b) 3. have been met.
NR 440.75(8)(f)
(f) Each owner or operator of a landfill seeking to comply with
sub. (3) (b) 2. using an active collection system designed in accordance with
sub. (3) (b) 2. b. shall submit to the department annual reports of the recorded information in
subds. 1. to
6. The initial annual report shall be submitted within 180 days of installation and startup of the collection and control system, and shall include the initial performance test report required under
s. NR 440.08. For enclosed combustion devices and flares, reportable exceedances are defined under
sub. (9) (c). The information which shall be recorded is as follows:
NR 440.75(8)(f)2.
2. Description and duration of all periods when the gas stream is diverted from the control device through a bypass line or the indication of bypass flow as specified under
sub. (7).
NR 440.75(8)(f)3.
3. Description and duration of all periods when the control device was not operating for a period exceeding one hour and length of time the control device was not operating.
NR 440.75(8)(f)4.
4. Description and duration of all periods when the collection system was not operating in excess of 5 days.
NR 440.75(8)(f)5.
5. The location of each exceedance of the 500 parts per million methane concentration as provided in
sub. (4) (a) 4. and the concentration recorded at each location for which an exceedance was recorded in the previous month.
NR 440.75(8)(g)
(g) Each owner or operator seeking to comply with
sub. (3) (b) 2. c. shall include the following information with the initial performance test report required under
s. NR 440.08:
NR 440.75(8)(g)1.
1. A diagram of the collection system showing collection system positioning including all wells, horizontal collectors, surface collectors or other gas extraction devices, including the locations of any areas excluded from collection and the proposed sites for the future collection system expansion.
NR 440.75(8)(g)2.
2. The data upon which the sufficient density of wells, horizontal collectors, surface collectors or other gas extraction devices and the gas mover equipment sizing are based.
NR 440.75(8)(g)3.
3. The documentation of the presence of asbestos or nondegradable material for each area from which collection wells have been excluded based on the presence of asbestos or nondegradable material.
NR 440.75(8)(g)4.
4. The sum of the gas generation flow rates for all areas from which collection wells have been excluded based on nonproductivity and the calculations of gas generation flow rate for each excluded area.
NR 440.75(8)(g)5.
5. The provisions for increasing gas mover equipment capacity with increased gas generation flow rate, if the present gas mover equipment is inadequate to move the maximum flow rate expected over the life of the landfill.
NR 440.75(9)(a)(a) Except as provided in
sub. (3) (b) 2. a. 2), each owner or operator of an MSW landfill subject to the provisions of
sub. (3) (b) shall keep for at least 5 years up-to-date, readily accessible, on-site records of the design capacity report which triggered
sub. (3) (b), the current amount of solid waste in-place, and the year-by-year waste acceptance rate. Off-site records may be maintained if they are retrievable within 4 hours. Either paper copy or electronic formats are acceptable.
NR 440.75(9)(b)
(b) Except as provided in
sub. (3) (b) 2. a. 2), each owner or operator of a controlled landfill shall keep up-to-date, readily accessible records for the life of the control equipment of the data listed in
subds. 1. to
4. as measured during the initial performance test or compliance determination. Records of subsequent tests or monitoring shall be maintained for a minimum of 5 years. Records of the control device vendor specifications shall be maintained until removal. The data is as follows:
NR 440.75(9)(b)1.
1. Where an owner or operator subject to the provisions of this section seeks to demonstrate compliance with
sub. (3) (b) 2. b., the following:
NR 440.75(9)(b)1.a.
a. The maximum expected gas generation flow rate as calculated in
sub. (6) (a) 1. The owner or operator may use another method to determine the maximum gas generation flow rate if the method has been approved by the department.
NR 440.75(9)(b)1.b.
b. The density of wells, horizontal collectors, surface collectors or other gas extraction devices determined using the procedures specified in
sub. (10) (a) 1.
NR 440.75(9)(b)2.
2. Where an owner or operator subject to the provisions of this section seeks to demonstrate compliance with
sub. (3) (b) 2. c. through use of an enclosed combustion device other than a boiler or process heater with a design heat input capacity equal to or greater than 44 megawatts, the following:
NR 440.75(9)(b)2.a.
a. The average combustion temperature measured at least every 15 minutes and averaged over the same time period of the performance test.
NR 440.75(9)(b)3.
3. Where an owner or operator subject to the provisions of this section seeks to demonstrate compliance with
sub. (3) (b) 2. c. 2) a) through use of a boiler or process heater of any size, a description of the location at which the collected gas vent stream is introduced into the boiler or process heater over the same time period of the performance testing.
NR 440.75(9)(b)4.
4. Where an owner or operator subject to the provisions of this section seeks to demonstrate compliance with
sub. (3) (b) 2. c. 1) through use of an open flare, the flare type (i.e., steam-assisted, air-assisted or nonassisted), all visible emission readings, heat content determination, flow rate or bypass flow rate measurements, exit velocity determinations made during the performance test as specified in
s. NR 440.18, continuous records of the flare pilot flame or flare flame monitoring and records of all periods of operations during which the pilot flame or the flare flame is absent.
NR 440.75(9)(c)
(c) Except as provided in
sub. (3) (b) 2. a. 2), each owner or operator of a controlled landfill subject to the provisions of this section shall keep for 5 years up-to-date, readily accessible continuous records of the equipment operating parameters specified to be monitored in
sub. (7) as well as up-to-date, readily accessible records for periods of operation during which the parameter boundaries established during the most recent performance test are exceeded. Each owner or operator shall do the following:
NR 440.75(9)(c)1.a.
a. For enclosed combustors except for boilers and process heaters with design heat input capacity of 44 megawatts, (150 million British thermal units per hour) or greater, all 3-hour periods of operation during which the average combustion temperature was more than 28
°C below the average combustion temperature during the most recent performance test at which compliance with
sub. (3) (b) 2. c. was determined.
NR 440.75(9)(c)1.b.
b. For boilers or process heaters, any change in the location at which the vent stream is introduced into the flame zone as required under
par. (b) 3.
NR 440.75(9)(c)2.
2. Keep up-to-date, readily accessible continuous records of the indication of flow to the control device or the indication of bypass flow or records of monthly inspections of car-seals or lock-and-key configurations used to seal bypass lines, specified under
sub. (7).
NR 440.75(9)(c)3.
3. If using a boiler or process heater with a design heat input capacity of 44 megawatts or greater to comply with
sub. (3) (b) 2. c., keep an up-to-date, readily accessible record of all periods of operation of the boiler or process heater.
NR 440.75 Note
Note:
Examples of records of operation include records of steam use, fuel use or monitoring data collected pursuant to other department or federal regulatory requirements.
NR 440.75(9)(c)4.
4. If seeking to comply with the provisions of this section by use of an open flare, keep up-to-date, readily accessible continuous records of the flame or flare pilot flame monitoring specified under
sub. (7) (c), and up-to-date, readily accessible records of all periods of operation in which the flame or flare pilot flame is absent.
NR 440.75(9)(d)
(d) Except as provided in
sub. (3) (b) 2. a. 2), keep for the life of the collection system an up-to-date, readily accessible plot map showing each existing and planned collector in the system and providing a unique identification location label for each collector.
NR 440.75(9)(e)
(e) Each owner or operator subject to the provisions of this section shall keep up-to-date, readily accessible records of the installation date and location of all newly installed collectors as specified under
sub. (6) (b).
NR 440.75(9)(f)
(f) Each owner or operator subject to the provisions of this section shall keep readily accessible documentation of the nature, date of deposition, amount and location of asbestos-containing or nondegradable waste excluded from collection as provided in
sub. (10) (a) 3. a. as well as any nonproductive areas excluded from collection as provided in
sub. (10) (a) 3. b.
NR 440.75(9)(g)
(g) Except as provided in
sub. (3) (b) 2. a. 2), each owner or operator subject to the provisions of this section shall keep for at least 5 years up-to-date, readily accessible records of all collection and control system exceedances of the operational standards in
sub. (4), the reading in the subsequent month whether or not the second reading is an exceedance, and the location of each exceedance.
NR 440.75(9)(h)
(h) Landfill owners or operators who convert design capacity from volume to mass or mass to volume to demonstrate that landfill design capacity is less than 2.5 million megagrams or 2.5 million cubic meters, as provided in the definition of “design capacity", shall keep readily accessible, on-site records of the annual recalculation of site-specific density, design capacity, and the supporting documentation. Off-site records may be maintained if they are retrievable within 4 hours. Either paper copy or electronic formats are acceptable.
NR 440.75(10)(a)(a) Each owner or operator seeking to comply with
sub. (3) (b) 2. a. shall site active collection wells, horizontal collectors, surface collectors or other extraction devices at a sufficient density throughout all gas producing areas using the following procedures unless alternative procedures have been approved by the department as provided in
sub. (3) (b) 2. a. 3) and 4):
NR 440.75(10)(a)1.
1. The collection devices within the interior and along the perimeter areas shall be certified to achieve comprehensive control of surface gas emissions by a professional engineer. The design for the collection system shall address depths of refuse, refuse gas generation rates and flow characteristics, cover properties, gas system expandability, leachate and condensate management, accessibility, compatibility with filling operations, integration with closure end use, air intrusion control, corrosion resistance, fill settlement and resistance to the refuse decomposition heat.
NR 440.75(10)(a)2.
2. The sufficient density of gas collection devices determined in
subd. 1. shall address landfill gas migration issues and augmentation of the collection system through the use of active or passive systems at the landfill perimeter or exterior.
NR 440.75(10)(a)3.
3. The placement of gas collection devices determined in
subd. 1. shall control all gas producing areas, except as follows:
NR 440.75(10)(a)3.a.
a. Any segregated area of asbestos or nondegradable material may be excluded from collection if documented as provided under
sub. (9) (f). The documentation shall provide the nature, date of deposition, location and amount of asbestos or nondegradable material deposited in the area, and shall be provided to the department upon request.
NR 440.75(10)(a)3.b.
b. Any nonproductive area of the landfill may be excluded from control, provided that the total of all excluded areas can be shown to contribute less than 1% of the total amount of NMOC emissions from the landfill. The amount, location and age of the material shall be documented and provided to the department upon request. A separate NMOC emissions estimate shall be made for each section proposed for exclusion, and the sum of all the sections shall be compared to the NMOC emissions estimate for the entire landfill. Emissions from each section shall be computed using the following equation:
where:
Qi is the NMOC emission rate from the ith section in megagrams per year