NR 440.642(1)(i)
(i) Modification or reconstruction, as defined in
ss. NR 440.14 and
440.15, does not, by itself, make a wood heater an affected facility under this section.
NR 440.642(2)
(2) Definitions. As used in this section, terms not defined in this subsection have the meanings given in
s. NR 440.02.
NR 440.642(2)(a)
(a) “At retail" means the sale by a commercial owner of a wood heater to the ultimate purchaser.
NR 440.642(2)(b)
(b) “Boiler" means a solid burning appliance used primarily for heating spaces, other than the space where the appliance is located, by the distribution through pipes of a gas or fluid heated in the appliance. The appliance shall be tested and listed as a boiler under accepted American or Canadian safety testing codes. A manufacturer may request an exemption in writing from the administrator by stating why the testing and listing requirement is not practicable and by demonstrating that this appliance is otherwise a boiler.
NR 440.642(2)(c)
(c) “Coal-only heater" means an enclosed, coal-burning appliance capable of space heating, or domestic water heating, which has all of the following characteristics:
NR 440.642(2)(c)1.
1. An opening for emptying ash that is located near the bottom or the side of the appliance.
NR 440.642(2)(c)3.
3. A grate or other similar device for shaking or disturbing the fuel bed or power-driven mechanical stoker.
NR 440.642(2)(c)4.
4. Installation instructions that state that the use of wood in stove, except for coal ignition purposes, is prohibited by law, and
NR 440.642(2)(c)5.
5. The model is listed by a nationally recognized safety-testing laboratory for use of coal only, except for coal ignition purposes.
NR 440.642(2)(d)
(d) “Commercial owner" means any person who owns or controls a wood heater in the course of the manufacture, importation, distribution, or sale of the wood heater.
NR 440.642(2)(e)
(e) “Cookstove" means a wood-fired appliance that is designed primarily for cooking food and that has the following characteristics:
NR 440.642(2)(e)1.
1. An oven, with a volume of 0.028 cubic meters (1 cubic foot) or greater, and an oven rack,
NR 440.642(2)(e)7.
7. The absence of a fan or heat channels to dissipate heat from the appliance.
NR 440.642(2)(f)
(f) “Furnace" means a solid fuel burning appliance that is designed to be located outside of ordinary living areas and that warms spaces other than the space where the appliance is located by the distribution of air heated in the appliance through ducts. The appliance shall be tested and listed as a furnace under accepted American or Canadian safety testing codes unless exempted from this provision by the administrator. A manufacturer may request an exemption in writing from the administrator by stating why the testing and listing requirement is not practicable and by demonstrating that the appliance is otherwise a furnace.
NR 440.642(2)(g)
(g) “Manufactured" means completed and ready for shipment (whether or not packaged).
NR 440.642(2)(h)
(h) “Manufacturer" means any person who constructs or imports a wood heater.
NR 440.642(2)(i)
(i) “Model line" means all wood heaters offered for sale by a single manufacturer that are similar in all material respects.
NR 440.642(2)(j)
(j) “Representative affected facility" means an individual wood heater that is similar in all material respects to other wood heaters within the model line it represents.
NR 440.642(2)(k)
(k) “Sale" means the transfer of ownership or control, except that transfer of control may not constitute a sale for purposes of
sub. (1) (f).
NR 440.642(2)(L)
(L) “Similar in all material respects" means that the construction materials, exhaust and inlet air system and other design features are within the allowed tolerances for components identified in
sub. (4) (k).
NR 440.642(2)(m)
(m) “Wood heater" means an enclosed woodburning appliance capable of and intended for space heating or domestic water heating that meets all of the following criteria:
NR 440.642(2)(m)1.
1. An air-to-fuel ratio in the combustion chamber averaging less than 35-to-1 as determined by the test procedure prescribed in
sub. (5), performed at an accredited laboratory,
NR 440.642(2)(m)2.
2. A usable firebox volume of less than 0.57 cubic meter (20 cubic feet).
NR 440.642(2)(m)3.
3. A minimum burn rate less than 5 kg/hr (11 lb/hr) as determined by the test procedure prescribed in
sub. (5) performed at an accredited laboratory.
NR 440.642(2)(m)4.
4. A maximum weight of 800 kg (1,760 lb). In determining the weight of an appliance for these purposes, fixtures and devices that are normally sold separately, such as flue pipe, chimney, and masonry components that are not an integral part of the appliance or heat distribution ducting, may not be included.
NR 440.642(3)
(3) Standards for particulate matter. Unless exempted under
sub. (1), each affected facility:
NR 440.642(3)(b)
(b) Manufactured on or after July 1, 1990, or sold at retail on or after July 1, 1992, shall comply with the following particulate matter emission limits as determined by the test methods and procedures in
sub. (5):
NR 440.642(3)(b)1.
1. An affected facility equipped with a catalytic combustor may not discharge into the atmosphere any gases which contain particulate matter in excess of a weighted average of 4.1 g/hr (0.009 lb/hr). Particulate emissions during any test run at any burn rate that is required to be used in the weighted average may not exceed the value calculated for “C" (rounded to 2 significant figures) calculated using the following equation:
where:
BR is the burn rate in kg/hr (lb/hr)
K1 = 3.55g/kg (0.00355 lb/lb)
K2 = 4.98 g/hr (0.0011 lb/hr)
NR 440.642(3)(b)1.b.
b. At burn rates greater than 2.82 kg/hr, (6.2 lb/hr), C = 15 g/hr (0.033 lb/hr).
NR 440.642(3)(b)2.
2. An affected facility not equipped with a catalytic combustor may not discharge into the atmosphere any gases which contain particulate matter in excess of a weighted average of 7.5 g/hr (0.017 lb/hr). Particulate emissions may not exceed 15 g/hr (0.033 lb/hr) during any test run at a burn rate less than or equal to 1.5 kg/hr (3.3 lb/hr) that is required to be used in the weighted average, and particulate emissions may not exceed 18 g/hr (0.040 lb/hr) during any test burn at a burn rate greater than 1.5 kg/hr (3.3 lb/hr) that is required to be used in the weighted average.
NR 440.642(4)(a)(a) For each model line, compliance with applicable emission limits may be determined based on testing of representative affected facilities within the model line.
NR 440.642(4)(b)
(b) Any manufacturer of an affected facility may apply to the administrator for a certificate of compliance for a model line. The application shall be in writing to: Stationary Source Compliance Division (EN-341), U.S. Environmental Protection Agency, 401 M Street SW, Washington DC 20460, Attention: Wood Heater Program. The manufacturer shall submit 2 complete copies of the application and attachments. The application shall be signed by the manufacturer, or an authorized representative, and shall contain the following:
NR 440.642(4)(b)2.
2. Two color photographs of the tested unit, one showing a front view and the other, a side view.
NR 440.642(4)(b)3.a.a. Engineering drawings and specifications of components that may affect emissions, including specifications for each component listed in
par. (k). Manufacturers may use complete assembly or design drawings that have been prepared for other purposes, but should designate on the drawings the dimensions of each component listed in
par. (k). Manufacturers shall identify tolerances of components of the tested unit listed in
par. (k) 2. that are different from those specified in that paragraph, and show that such tolerances may not reasonably be anticipated to cause wood heaters in the model line to exceed the applicable emission limits.
NR 440.642(4)(b)3.b.
b. A statement whether the firebox or any firebox component (other than one listed in
par. (k) 3.) will be composed of different material from the material used for the firebox or firebox component in the wood heater on which certification testing was performed and a description of any such differences.
NR 440.642(4)(b)3.c.
c. For applications to certify a model line of catalytic wood heaters to meet the emission limits in
sub. (3) (b), a statement describing the manufacturer's program to ensure consistency in the size of any gap in the catalyst bypass mechanism. The statement shall describe, in narrative form, the components of the system that affect the size of the gap, any specifications for critical dimensions of any such components, and the procedure the manufacturer will use to ensure consistency in the size of the catalyst bypass gap.
NR 440.642(4)(b)4.
4. All documentation pertaining to a valid certification test, including the complete test report and, for all test runs: raw data sheets, laboratory technician notes, calculations, and test results. Documentation shall include the items specified in the applicable test methods. Recommended formats and guidance materials are available from the administrator.
NR 440.642(4)(b)5.
5. For catalytic wood heaters, a copy of the catalytic combustor warranty,
NR 440.642(4)(b)6.
6. A statement that the manufacturer will conduct a quality assurance program for the model line which satisfies the requirements of
par. (o).
NR 440.642(4)(b)7.
7. A statement describing how the tested unit was sealed by the laboratory after the completion of certification testing, and
NR 440.642(4)(b)8.
8. A statement that the manufacturer will notify the accredited laboratory if the application for certification is granted, within 30 days of receipt of notification from the U.S. environmental protection agency.
NR 440.642(4)(b)9.
9. Statements that the wood heaters manufactured under this certificate will be:
NR 440.642(4)(b)9.a.
a. Similar in all material respects to the wood heater submitted for certification testing, and
NR 440.642(4)(b)10.
10. For catalytic wood heaters, a statement that the warranty, access and inspection, and temperature monitoring provisions in
pars. (c),
(d), and
(m) will be met.
NR 440.642(4)(b)11.
11. A statement that the manufacturer will comply with the recordkeeping and reporting requirements in
sub. (8).
NR 440.642(4)(b)12.
12. A written estimate of the number of wood heaters that the manufacturer anticipates will be produced annually for the first 2 production years. Compliance with this provision may be obtained by designating one of the following ranges:
NR 440.642(4)(b)13.
13. At the beginning of each test run in a certification test series, 2 photographs of the fuel load: One before and one after it is placed in the wood heater. One of the photographs shall show the front view of the wood load and the other shall show the side view.
NR 440.642(4)(b)14.
14. For manufacturers seeking certification of model lines under
sub. (4) (e) to meet the emission limits in
sub. (3) (b), a statement that the manufacturer has entered into a contract with an accredited laboratory which satisfied the requirements of
par. (g).
NR 440.642(4)(c)
(c) If the affected facility is a catalytic wood heater, the warranty for the catalytic combustor shall include the replacement of the combustor and any prior replacement combustor without charge to the consumer for:
NR 440.642(4)(c)1.
1. Two years from the date the consumer purchased the heater for any defects in workmanship or materials that prevent the combustor from functioning when installed and operated properly in the wood heater, and
NR 440.642(4)(c)2.
2. Three years from the date the consumer purchased the heater for thermal crumbling or disintegration of the substrate material for heaters manufactured after July 1, 1990.
NR 440.642(4)(d)
(d) The manufacturer of an affected facility equipped with a catalytic combustor shall provide for a means to allow the owner to gain access readily to the catalyst for inspection or replacement purposes and shall document in the application for certification how the catalyst is replaced.
NR 440.642(4)(e)1.1. The administrator shall issue a certificate of compliance for a model line if he or she determines, based on all information submitted by the applicant and any other relevant information available, that all of the following requirements have been met:
NR 440.642(4)(e)1.a.
a. A valid certification test has demonstrated that the wood heater representative of the model line complies with the applicable particulate emission limits in
sub. (3),
NR 440.642(4)(e)1.b.
b. Any tolerances or materials for components listed in
par. (k) 2. or
3. that are different from those specified in those paragraphs may not reasonably be anticipated to cause wood heaters in the model line to exceed the applicable emission limits.
NR 440.642(4)(e)2.
2. Upon denying certification under this paragraph, the administrator shall give written notice to the manufacturer setting forth the basis for the determination.
NR 440.642(4)(f)2.
2. Conducted by a testing laboratory accredited by the administrator pursuant to
sub. (6),
NR 440.642(4)(f)3.
3. Conducted on a wood heater similar in all material respects to other wood heaters of the model line that is to be certified, and
NR 440.642(4)(g)
(g) To have a wood heater model certified under
sub. (4) (e) to meet the emission limits in
sub. (3) (b), a manufacturer shall enter into a contract with the accredited laboratory that performed the certification test, under which the laboratory will:
NR 440.642(4)(g)1.
1. Conduct the random compliance audit test at no cost to the manufacturer if the U.S. environmental protection agency selects that laboratory to conduct the test, or
NR 440.642(4)(g)2.
2. Pay the manufacturer the reasonable cost of a random compliance audit test (as determined by the U.S. environmental protection agency) if the U.S. environmental protection agency selects any other laboratory to conduct the test.