This is the preview version of the Wisconsin State Legislature site.
Please see http://docs.legis.wisconsin.gov for the production version.
NR 440.565(4)(d) (d) Where compliance with the emission limit specified in sub. (3) (a) 2. is achieved through the use of a solvent destruction device the owner or operator shall determine calendar monthly compliance by comparing the monthly required overall VOC emission reduction specified in par. (b) to the overall VOC emission reduction demonstrated in the most recent performance test which complied with sub. (3) (a) 2. If the monthly required overall VOC emission reduction is less than or equal to the overall VOC reduction of the most recent performance test the affected facility is in compliance with sub. (3) (a) 2.
NR 440.565(4)(e) (e) Where compliance with sub. (3) (a) 2. is achieved through the use of a solvent destruction device, the owner or operator shall continuously record the destruction device combustion temperature during coating operations for thermal incineration destruction devices or the gas temperature upstream and downstream of the incinerator catalyst bed during coating operations for catalytic incineration destruction devices. For thermal incineration destruction devices the owner or operator shall record all 3-hour periods (during actual coating operations) during which the average temperature of the device is more than 28°C (50°F) below the average temperature of the device during the most recent performance test complying with sub. (3) (a) 2. For catalytic incineration destruction devices, the owner or operator shall record all 3-hour periods (during actual coating operations) during which the average temperature of the device immediately before the catalyst bed is more than 28°C (50°F) below the average temperature of the device during the most recent performance test complying with sub. (3) (a) 2. and all 3-hour periods (during actual coating operations) during which the average temperature difference across the catalyst bed is less than 80% of the average temperature difference of the device during the most recent test complying with sub. (3) (a) 2.
NR 440.565(4)(f) (f) After the initial performance test required for all affected facilities under s. NR 440.08, compliance with the VOC emission limitation and percentage reduction requirements under sub. (3) is based on the average emission reduction for one calendar month. A separate compliance test is completed at the end of each calendar month after the initial performance test and a new calendar month's average VOC emission reduction is calculated to show compliance with the standard.
NR 440.565(4)(g) (g) If a common emission control device is used to recover or destroy solvent from more than one affected facility the performance of that control device is assumed to be equal for each of the affected facilities. Compliance with sub. (3) (a) 2. is determined by the methods specified in pars. (c) and (d) and is performed simultaneously on all affected facilities.
NR 440.565(4)(h) (h) If a common emission control device is used to recover solvent from an existing facility (or facilities) as well as from an affected facility (or facilities) the overall VOC emission reduction for the affected facility (or facilities) for the purpose of compliance, shall be determined by the following procedures:
NR 440.565(4)(h)1. 1. The owner or operator of the existing facility (or facilities) shall determine the mass of solvent recovery for a calendar month period from the existing facility (or facilities) prior to the connection of the affected facility (or facilities) to the emission control device.
NR 440.565(4)(h)2. 2. The affected facility (or facilities) shall then be connected to the emission control device.
NR 440.565(4)(h)3. 3. The owner or operator shall determine the total mass of solvent recovery from both the existing and affected facilities over a calendar month period. The mass of solvent determined in subd. 1. from the existing facility shall be subtracted from the total mass of recovery solvent to obtain the mass of solvent recovery from the affected facility (or facilities). The overall VOC emission reduction of the affected facility (or facilities) can then be determined as specified in par. (c).
NR 440.565(4)(i) (i) If a common emission control device is used to destruct solvent from an existing facility (or facilities) as well as from an affected facility (or facilities) the overall VOC emission reduction for the affected facility (or facilities), for the purpose of compliance, shall be determined by the following procedures:
NR 440.565(4)(i)1. 1. The owner or operator shall operate the emission control device with both the existing and affected facilities connected.
NR 440.565(4)(i)2. 2. The concentration of VOC (in parts per million by volume) after the common emission control device shall be determined as specified in sub. (5) (c).
NR 440.565(4)(j) (j) Startups and shutdowns are normal operation for this source category. Emissions from these operations are to be included when determining if the standard specified at sub. (3) (a) 2. is being attained.
NR 440.565(5) (5)Performance test procedures.
NR 440.565(5)(a)(a) The performance test for affected facilities complying with sub. (3) without the use of add-on controls shall be identical to the procedures specified in sub. (4) (a).
NR 440.565(5)(b) (b) The performance test for affected facilities controlled by a solvent recovery device shall be conducted as follows:
NR 440.565(5)(b)1. 1. The performance test shall be a one calendar month test and not the average of 3 runs as specified in s. NR 440.08 (6).
NR 440.565(5)(b)2. 2. The weighted average mass of VOC per mass of coating solids applied for a one calendar month period shall be determined as specified in sub. (4) (a) 2.
NR 440.565(5)(b)3. 3. Calculate the required percent overall VOC emission reduction as specified in sub. (4) (b).
NR 440.565(5)(b)4. 4. Inventory VOC usage and VOC recovery for a one calendar month period.
NR 440.565(5)(b)5. 5. Determine the percent overall VOC emission reduction as specified in sub. (4) (c).
NR 440.565(5)(c) (c) The performance test for affected facilities controlled by a solvent destruction device shall be conducted as follows:
NR 440.565(5)(c)1. 1. The performance of the solvent destruction device shall be determined by averaging the results of 3 test runs as specified in s. NR 440.08 (6).
NR 440.565(5)(c)2. 2. Determine for each affected facility prior to each test run the weighted average mass of VOC per mass of coating solids applied being used at the facility. The weighted average shall be determined as specified in sub. (4) (a). In this application the quantities of Woi, Wsi and Mci shall be determined for the time period of each test run and not a calendar month as specified in sub. (2).
NR 440.565(5)(c)3. 3. Calculate the required percent overall VOC emission reduction as specified in sub. (4) (b).
NR 440.565(5)(c)4. 4. Determine the percent overall VOC emissions reduction of the solvent destruction device by the following equation and procedures: - See PDF for diagram PDF
NR 440.565(5)(c)4.a. a. The owner or operator of the affected facility shall construct the overall VOC emission reduction system so that all volumetric flow rates and total VOC emissions can be accurately determined by the applicable test methods and procedures specified in sub. (7) (b).
NR 440.565(5)(c)4.b. b. The owner or operator of an affected facility shall construct a temporary total enclosure around the coating line applicator and flashoff area during the performance test for the purpose of capturing fugitive VOC emissions. If a permanent total enclosure exists in the affected facility prior to the performance test and the department is satisfied that the enclosure is totally capturing fugitive VOC emissions then no additional total enclosure will be required for the performance test.
NR 440.565(5)(c)4.c. c. For each affected facility where the value of R is greater than or equal to the value Rq calculated in sub. (4) (b) compliance with sub. (3) (a) 2. is demonstrated.
NR 440.565(6) (6)Monitoring of operations and recordkeeping.
NR 440.565(6)(a)(a) The owner or operator of an affected facility subject to this section shall maintain a calendar month record of all coatings used and the results of the reference test methods specified in sub. (7) (a) or the manufacturer's formulation data used for determining the VOC content of those coatings.
NR 440.565(6)(b) (b) The owner or operator of an affected facility controlled by a solvent recovery device shall maintain a calendar month record of the amount of solvent applied in the coating at each affected facility.
NR 440.565(6)(c) (c) The owner or operator of an affected facility controlled by a solvent recovery device shall install, calibrate, maintain and operate a monitoring device for indicating the cumulative amount of solvent recovery by the device over a calendar month period. The monitoring device shall be accurate within "2.0%. The owner or operator shall maintain a calendar month record of the amount of solvent recovery by the device.
NR 440.565(6)(d) (d) The owner or operator of an affected facility operating at the conditions specified in sub. (1) (b) shall maintain a 12 month record of the amount of solvent applied in the coating at the facility.
NR 440.565(6)(e) (e) The owner or operator of an affected facility controlled by a thermal incineration solvent destruction device shall install, calibrate, maintain and operate a monitoring device which continuously indicates and records the temperature of the solvent destruction device's exhaust gases. The monitoring device shall have an accuracy of the greater of " 0.75% of the temperature being measured expressed in degrees Celsius or " 2.5°C.
NR 440.565(6)(f) (f) The owner or operator of an affected facility controlled by a catalytic incinerator solvent destruction device shall install, calibrate, maintain, and operate a monitoring device which continuously indicates and records the gas temperature both upstream and downstream of the catalyst bed.
NR 440.565(6)(g) (g) The owner or operator of an affected facility controlled by a solvent destruction device which uses a hood or enclosure to capture fugitive VOC emissions shall install, calibrate, maintain and operate a monitoring device which continuously indicates that the hood or enclosure is operating. No continuous monitor is required if the owner or operator can demonstrate that the hood or enclosure system is interlocked with the affected facility's oven recirculation air system.
NR 440.565(6)(h) (h) Records of the measurements required in subs. (4) and (6) must be retained for at least two years following the date of the measurements.
NR 440.565(7) (7)Test methods and procedures.
NR 440.565(7)(a)(a) The VOC contents per unit of coating solids applied and compliance with sub. (3) (a) 1. shall be determined by either Method 24 of 40 CFR part 60, Appendix A, incorporated by reference in s. NR 440.17 (1), and the equations specified in sub. (4) or by manufacturer's formulation data. In the event of any inconsistency between a Method 24 test and manufacturer's formulation data, the Method 24 test will govern. The department may require an owner or operator to perform Method 24 tests during such months as it deems appropriate. For Method 24, the coating sample shall be a one liter sample taken into a one liter container at a point where the sample will be representative of the coating applied to the web substrate.
NR 440.565(7)(b) (b) Method 25 of 40 CFR part 60, Appendix A, incorporated by reference in s. NR 440.17 (1), shall be used to determine the VOC concentration, in parts per million by volume, of each effluent gas stream entering and exiting the solvent destruction device or its equivalent and each effluent gas stream emitted directly to the atmosphere. Methods 1, 2, 3, and 4 of 40 CFR part 60, Appendix A, incorporated by reference in s. NR 440.17 (1), shall be used to determine the sampling location, volumetric flow rate, molecular weight and moisture of all sampled gas streams. For Method 25, the sampling time for each of 3 runs shall be at least one hour. The minimum sampling volume shall be 0.003 dscm except that shorter sampling times or smaller volumes, when necessitated by process variables or other factors, may be approved by the department.
NR 440.565(7)(c) (c) If the owner or operator can demonstrate to the department's satisfaction that testing of representative stacks yields results comparable to those that would be obtained by testing all stacks the department will approve testing of representative stacks on a case-by-case basis.
NR 440.565(8) (8)Reporting requirements.
NR 440.565(8)(a)(a) For all affected facilities subject to compliance with sub. (3) the performance test data and results from the performance test shall be submitted to the department as specified in s. NR 440.08 (1).
NR 440.565(8)(b) (b) Following the initial performance test, the owner or operator of each affected facility shall submit quarterly reports to the department of exceedances of the VOC emission limits specified in sub. (3). If no exceedances occur during a particular quarter, a report stating this shall be submitted to the department semiannually.
NR 440.565(8)(c) (c) The owner or operator of each affected facility shall also submit reports at the frequency specified in s. NR 440.07 (3) when the incinerator temperature drops as defined under sub. (4) (e). If no such periods occur, the owner or operator shall state this in the report.
NR 440.565 History History: Cr. Register, September, 1986, No. 369, eff. 10-1-86; renum. to be NR 440.565 and am. (2) (a) (intro.) and (b) (intro.), (5) (b) 1. and (c) 1. and (6) (g), r. (8) (c), Register, September, 1990, No. 417, eff. 10-1-90; r. and recr. (8) (b), cr. (8) (c), Register, June, 1993, No. 450, eff. 8-1-93; CR 06-109: am. (1) (b), (2) (a) 3. and (b) 14. and 15., (3) (a) 2. a., (4) (e), and (7) (a) and (b) Register May 2008 No. 629, eff. 6-1-08.
NR 440.57 NR 440.57Industrial surface coating: large appliances.
NR 440.57(1)(1)Applicability and designation of affected facility.
NR 440.57(1)(a)(a) The provisions of this section apply to each surface coating operation in a large appliance surface coating line.
NR 440.57(1)(b) (b) Any facility under par. (a) that commences construction, modification or reconstruction after December 24, 1980, is subject to the requirements of this section.
NR 440.57(2) (2)Definitions and symbols.
NR 440.57(2)(a)(a) As used in this section, terms not defined in this paragraph have the meanings given in s. NR 440.02.
NR 440.57(2)(a)1. 1. “Applied coating solids" means the coating solids that adhere to the surface of the large appliance part being coated.
NR 440.57(2)(a)2. 2. “Coating application station" means that portion of the large appliance surface coating operation where a prime coat or a topcoat is applied to large appliances parts or products (e.g., dip tank, spray booth or flow coating unit).
NR 440.57(2)(a)3. 3. “Curing oven" means a device that uses heat to dry or cure the coatings applied to large appliance parts or products.
NR 440.57(2)(a)4. 4. “Electrodeposition" or “EDP" means a method of coating application in which the large appliance part or product is submerged in a tank filled with coating material suspended in water and an electrical potential is used to enhance deposition of the material on the part or product.
NR 440.57(2)(a)5. 5. “Flashoff area" means the portion of a surface coating line between the coating application station and the curing oven.
NR 440.57(2)(a)6. 6. “Large appliance part" means any organic surface-coated metal lid, door, casing, panel or other interior or exterior metal part or accessory that is assembled to form a large appliance product. Parts subject to in-use temperatures in excess of 250°F are not included in this definition.
NR 440.57(2)(a)7. 7. “Large appliance product" means any organic surface-coated metal range, oven, microwave oven, refrigerator, freezer, washer, dryer, dishwasher, water heater or trash compactor manufactured for household, commercial or recreational use.
NR 440.57(2)(a)8. 8. “Large appliance surface coating line" means that portion of a large appliance assembly plant engaged in the application and curing of organic surface coatings on large appliance parts or products.
NR 440.57(2)(a)9. 9. “Organic coating" means any coating used in a surface coating operation, including dilution solvents, from which VOC emissions occur during the application or the curing process. For the purpose of this section, powder coatings are not included in this definition.
NR 440.57(2)(a)10. 10. “Powder coating" means any surface coating that is applied as a dry powder and is fused into a continuous coating film through the use of heat.
NR 440.57(2)(a)11. 11. “Spray booth" means the structure housing automatic or manual spray application equipment where a coating is applied to large appliance parts or products.
NR 440.57(2)(a)12. 12. “Surface coating operation" means the system on a large appliance surface coating line used to apply and dry or cure an organic coating on the surface of large appliance parts or products. The surface coating operation may be a prime coat or a topcoat operation and includes the coating application station or stations, flashoff area and curing oven.
NR 440.57(2)(a)13. 13. “Transfer efficiency" means the ratio of the amount of coating solids deposited onto the surface of a large appliance part or product to the total amount of the coating solids used.
NR 440.57(2)(a)14. 14. “VOC content" means the proportion of a coating that is volatile organic compounds (VOCs), expressed as kilograms of VOCs per liter of coating solids.
NR 440.57(2)(a)15. 15. “VOC emissions" means the mass of volatile organic compounds (VOCs), expressed as kilograms of VOCs per liter of applied coating solids, emitted from a surface coating operation.
NR 440.57(2)(b) (b) As used in this section, symbols not defined in this paragraph have the meanings given in s. NR 440.03.
NR 440.57(2)(b)1. 1. Ca is the concentration of VOCs in a gas stream leaving a control device and entering the atmosphere (parts per million by volume, as carbon).
NR 440.57(2)(b)2. 2. Cb is the concentration of VOCs in a gas stream entering a control device (parts per million by volume, as carbon).
NR 440.57(2)(b)3. 3. Cf is the concentration of VOCs in a gas stream emitted directly to the atmosphere (parts per million by volume, as carbon).
NR 440.57(2)(b)4. 4. Dc is the density of coating (or input stream), as received (kilograms per liter).
NR 440.57(2)(b)5. 5. Dd is the density of a VOC solvent added to coatings (kilograms per liter).
NR 440.57(2)(b)6. 6. Dr is the density of a VOC solvent recovered by an emission control device (kilograms per liter).
NR 440.57(2)(b)7. 7. E is the VOC destruction efficiency of a control device (fraction).
NR 440.57(2)(b)8. 8. F is the proportion of total VOCs emitted by an affected facility that enters a control device (fraction).
NR 440.57(2)(b)9. 9. G is the volume-weighted average mass of VOCs in coatings consumed in a calendar month per unit volume of applied coating solids (kilograms per liter).
NR 440.57(2)(b)10. 10. Lc is the volume of coating consumed, as received (liters).
NR 440.57(2)(b)11. 11. Ld is the volume of VOC solvent added to coatings (liters).
NR 440.57(2)(b)12. 12. Lr is the volume of VOC solvent recovered by an emission control device (liters).
NR 440.57(2)(b)13. 13. Ls is the volume of coating solids consumed (liters).
NR 440.57(2)(b)14. 14. Md is the mass of VOC solvent added to coatings (kilograms).
NR 440.57(2)(b)15. 15. Mo is the mass of VOCs in coatings consumed, as received (kilograms).
NR 440.57(2)(b)16. 16. Mr is the mass of VOCs recovered by an emission control device (kilograms).
NR 440.57(2)(b)17. 17. Qa is the volumetric flow rate of a gas stream leaving a control device and entering the atmosphere (dry standard cubic meters per hour).
NR 440.57(2)(b)18. 18. Qb is the volumetric flow rate of a gas stream entering a control device (dry standard cubic meters per hour).
NR 440.57(2)(b)19. 19. Qf is the volumetric flow rate of a gas stream emitted directly to the atmosphere (dry standard cubic meters per hour).
NR 440.57(2)(b)20. 20. R is the overall VOC emission reduction achieved for an affected facility (fraction).
NR 440.57(2)(b)21. 21. T is the transfer efficiency (fraction).
Loading...
Loading...
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date the chapter was last published.