NR 440.23(5)(c)
(c) The owner or operator may use the following as alternatives to the methods and procedures specified in this subsection:
NR 440.23(5)(c)1.
1. For Method 7, Method 7A, 7B, 7C or 7D may be used. If Method 7C or 7D is used, the sampling time shall be at least 1 hour.
NR 440.23(5)(d)
(d) The owner or operator shall use the procedure in
sub. (4) (b) to determine the conversion factor for converting the monitoring data to the units of the standard.
NR 440.23 History
History: Cr.
Register, January, 1984, No. 337, eff. 2-1-84; am. (4) (a), (5) (a) 1., and (b),
Register, September, 1986, No. 369, eff. 10-1-86; am. (2) (intro.), (4) (e) and (5) (b),
Register, September, 1990, No. 417, eff. 10-1-90; r. and recr. (4) (a) and (5), am. (4) (b),
Register, June, 1993, No. 450, eff. 8-1-93.
NR 440.24(1)
(1)
Applicability and designation of affected facility. NR 440.24(1)(a)(a) The provisions of this section are applicable to each sulfuric acid production unit, which is the affected facility.
NR 440.24(1)(b)
(b) Any facility under
par. (a) that commences construction or modification after August 17, 1971, is subject to the requirements of this section.
NR 440.24(2)
(2) Definitions. As used in this section, terms not defined in this subsection have the meanings given in
s. NR 440.02.
NR 440.24(2)(a)
(a) “Acid mist" means sulfuric acid mist, as measured by Method 8 of
40 CFR part 60, Appendix A, incorporated by reference in
s. NR 440.17, or an equivalent or alternative method.
NR 440.24(2)(b)
(b) “Sulfuric acid production unit" means any facility producing sulfuric acid by the contact process by burning elemental sulfur, alkylation acid, hydrogen sulfide, organic sulfides and mercaptans or acid sludge, but does not include facilities where conversion to sulfuric acid is utilized primarily as a means of preventing emissions to the atmosphere of sulfur dioxide or other sulfur compounds.
NR 440.24(3)(a)(a) On and after the date on which the performance test required to be conducted by
s. NR 440.08 is completed, no owner or operator subject to the provisions of this section may cause to be discharged into the atmosphere from any affected facility any gases which contain sulfur dioxide in excess of 2.0 kg per metric ton of acid produced (4.0 lb per ton), the production being expressed as 100% H
2SO
4.
NR 440.24(4)(a)(a) On and after the date on which the performance test required to be conducted by
s. NR 440.08 is completed, no owner or operator subject to the provisions of this section may cause to be discharged into the atmosphere from any affected facility any gases which:
NR 440.24(4)(a)1.
1. Contain acid mist, expressed as H
2SO
4, in excess of 0.075 kg per metric ton of acid produced (0.15 lb per ton), the production being expressed as 100% H
2SO
4.
NR 440.24(5)(a)(a) A continuous monitoring system for the measurement of sulfur dioxide shall be installed, calibrated, maintained and operated by the owner or operator. The pollutant gas used to prepare calibration gas mixtures under Performance Specification 2 of
40 CFR part 60, Appendix B, incorporated by reference in
s. NR 440.17, and for calibration checks under
s. NR 440.13 (4) shall be sulfur dioxide (SO
2). Method 8 of
40 CFR part 60, Appendix A, incorporated by reference in
s. NR 440.17, shall be used for conducting monitoring system performance evaluations under
s. NR 440.13 (3), except that only the sulfur dioxide portion of the Method 8 results shall be used. The span value shall be set at 1000 ppm of sulfur dioxide.
NR 440.24(5)(b)
(b) The owner or operator shall establish a conversion factor for the purpose of converting monitoring data into units of the applicable standard (kg/metric ton, lb/ton). The conversion factor shall be determined, at a minimum, 3 times daily by measuring the concentration of sulfur dioxide entering the converter using suitable methods (e.g., the Reich test, National Air Pollution Control Administration Publication No. 999-AP-13) and calculating the appropriate conversion factor for each 8-hour period as follows: -
See PDF for diagram
where:
CF is the conversion factor (kg/metric ton per ppm, lb/ton per ppm)
k is the constant derived from material balance. For determining CF in metric units, k = 0.0653. For determining CF in English units, k = 0.1306.
r is the percentage of sulfur dioxide by volume entering the gas converter. Appropriate corrections must be made for air injection plants subject to the department's approval.
s is the percentage of sulfur dioxide by volume in the emissions to the atmosphere determined by the continuous monitoring system required under par. (a).
NR 440.24(5)(c)
(c) The owner or operator shall record all conversion factors and values under
par. (b) from which they were computed (i.e., CF, r, and s).
NR 440.24(5)(d)
(d) Alternatively, a source that processes elemental sulfur or an area that contains elemental sulfur and uses air to supply oxygen may use the following continuous emission monitoring approach and calculation procedures in determining SO
2 emission rates in terms of the standard. This procedure is not required but is an alternative that would alleviate problems encountered in the measurement of gas velocities or production rate. Continuous emission monitoring systems for measuring SO
2, O
2 and CO
2, if required, shall be installed, calibrated, maintained and operated by the owner or operator and subjected to the certification procedures in Performance Specifications 2 and 3 in Appendix B,
40 CFR part 60, incorporated by reference in
s. NR 440.17 (1). The calibration procedure and span value for the SO
2 monitor shall be as specified in
par. (b). The span value for CO
2, if required, shall be 10% and for O
2 shall be 20.9% (air). A conversion factor based on process rate data is not necessary. Calculate the SO
2 emission rate as follows: -
See PDF for diagram
where:
Es is the SO2 emission rate in kg/metric ton (lb/ton) of 100% of H2SO4 produced
Cs is the concentration of SO2, kg/dscm (lb/dscf) (see the table in the note following this paragraph)
S is the acid production rate factor, 368 dscm/metric ton (11,800 dscf/ton) of 100% H2SO4 produced
%O2 is the oxygen concentration, percent dry basis
A is the auxiliary fuel factor,
= 0.00 for no fuel
= 0.0226 for methane
= 0.0217 for natural gas
= 0.0196 for propane
= 0.0172 for #2 oil
= 0.0161 for #6 oil
= 0.0148 for coal
= 0.0126 for coke
%CO2 is the carbon dioxide concentration, percent dry basis
NR 440.24 Note
Note:
It is necessary in some cases to convert measured concentration units to other units for these calculations. Use the following table for such conversions:
-
See PDF for table NR 440.24(5)(e)
(e) For the purpose of reports under
s. NR 440.07 (3), periods of excess emissions shall be all 3-hour periods (or the arithmetic average of 3 consecutive 1-hour periods) during which the integrated average sulfur dioxide emissions exceed the applicable standards under
sub. (3).
NR 440.24(6)(a)(a) In conducting the performance tests required in
s. NR 440.08, the owner or operator shall use as reference methods and procedures the test methods in Appendix A of
40 CFR part 60, incorporated by reference in
s. NR 440.17, or other methods and procedures as specified in this subsection, except as provided in
s. NR 440.08 (2). Acceptable alternative methods and procedures are given in
par. (c).
NR 440.24(6)(b)
(b) The owner or operator shall determine compliance with the SO
2 acid mist, and visible emission standards in
subs. (4) and
(5) as follows:
NR 440.24(6)(b)1.
1. The emission rate (E) of acid mist or SO
2 shall be computed for each run using the following equation:
E = (CQsd)/(PK)
where:
E is the emission rate of acid mist or SO2 kg/metric ton (lb/ton) of 100% H2SO4 produced
C is the concentration of acid mist or SO2, g/dscm (lb/dscf)
Qsd is the volumetric flow rate of the effluent gas, dscm/hr (dscf/hr)
P is the production rate of 100% H2SO4, metric ton/hr (ton/hr)
K is the conversion factor, 1000 g/kg (1.0 lb/lb)
NR 440.24(6)(b)2.
2. Method 8 shall be used to determine the acid mist and SO
2 concentrations (C's) and the volumetric flow rate (Q
sd) of the effluent gas. The moisture content may be considered to be zero. The sampling time and sample volume for each run shall be at least 60 minutes and 1.15 dscm (40.6 dscf).
NR 440.24(6)(b)3.
3. Suitable methods shall be used to determine the production rate (P) of 100% H
2SO
4 for each run. Material balance over the production system shall be used to confirm the production rate.
NR 440.24(6)(c)
(c) The owner or operator may use the following as alternatives to the reference methods and procedures specified in this subsection:
NR 440.24(6)(c)1.
1. If a source processes elemental sulfur or an ore that contains elemental sulfur and uses air to supply oxygen, the following procedure may be used instead of determining the volumetric flow rate and production rate:
NR 440.24(6)(c)1.a.
a. The integrated technique of Method 3 is used to determine the O
2 concentration and, if required, CO
2 concentration.
NR 440.24(6)(c)1.b.
b. The SO
2 or acid mist emission rate is calculated as described in
sub. (5) (d), substituting the acid mist concentration for C
s as appropriate.
NR 440.24 History
History: Cr.
Register, January, 1984, No. 337, eff. 2-1-84; cr. (5) (d) and (6) (e),
Register, September, 1986, No. 369, eff. 10-1-86; am. (2) (intro.) and (3) (a),
Register, September, 1990, No. 417, eff. 10-1-90; am. (5) (a) and (b), r. and recr. (5) (d) and (6),
Register, July, 1993, No. 451, eff. 8-1-93; cr. (5) (e),
Register, December, 1995, No. 480, eff. 1-1-96;
CR 06-109: am. (5) (d) Register May 2008 No. 629, eff. 6-1-08. NR 440.25(1)
(1)
Applicability and designation of affected facility. NR 440.25(1)(a)(a) The affected facility to which the provisions of this section apply is each hot mix asphalt facility. For the purpose of this section, a hot mix asphalt facility is comprised only of any combination of the following: dryers; systems for screening, handling, storing and weighing hot aggregate; systems for loading, transferring and storing mineral filler; systems for mixing hot mix asphalt; and the loading, transfer and storage systems associated with emission control systems.
NR 440.25(1)(b)
(b) Any facility under
par. (a) that commences construction or modification after June 11, 1973, is subject to the requirements of this section.
NR 440.25(2)
(2) Definitions. As used in this section, terms not defined in this subsection have the meanings given in
s. NR 440.02.
NR 440.25(2)(a)
(a) “Hot mix asphalt facility" means any facility, as described in
sub. (1), used to manufacture hot mix asphalt by heating and drying aggregate and mixing with asphalt cement.
NR 440.25(3)(a)(a) On and after the date on which the performance test required to be conducted by
s. NR 440.08 is completed, no owner or operator subject to the provisions of this section may discharge or cause the discharge into the atmosphere from any affected facility any gases which:
NR 440.25(3)(a)1.
1. Contain particulate matter in excess of 90 mg/dscm (0.039 gr/dscf).
NR 440.25(4)(a)(a) In conducting the performance tests required in
s. NR 440.08, the owner or operator shall use as reference methods and procedures the test methods in Appendix A of
40 CFR part 60, incorporated by reference in
s. NR 440.17, or other methods and procedures as specified in this subsection, except as provided in
s. NR 440.08 (2).
NR 440.25(4)(b)
(b) The owner or operator shall determine compliance with the particulate matter standards in
sub. (3) as follows:
NR 440.25(4)(b)1.
1. Method 5 shall be used to determine the particulate matter concentration. The sampling time and sample volume for each run shall be at least 60 minutes and 0.90 dscm (31.8 dscf).
NR 440.25 History
History: Cr.
Register, January, 1984, No. 337, eff. 2-1-84; am. (1) (a), (2) (intro.) and (a), (3) (a) 1.,
Register, September, 1990, No. 417, eff. 10-1-90; r. and recr. (4),
Register, July, 1993, No. 451, eff. 8-1-93.
NR 440.26(1)
(1)
Applicability, designation of affected facility, and reconstruction. NR 440.26(1)(a)(a) The provisions of this section are applicable to the following affected facilities in petroleum refineries: fluid catalytic cracking unit catalyst regenerators, fuel gas combustion devices, and all Claus sulfur recovery plants except Claus plants of 20 long tons per day (LTD) or less. The Claus sulfur recovery plant need not be physically located within the boundaries of a petroleum refinery to be an affected facility, provided it processes gases produced within a petroleum refinery.
NR 440.26(1)(b)
(b) Any fluid catalytic cracking unit catalyst regenerator or fuel gas combustion device under
par. (a) which commences construction or modification after June 11, 1973 or any Claus sulfur recovery plant under
par. (a) which commences construction or modification after October 4, 1976, is subject to the requirements of this section except as provided under
pars. (c) and
(d).
NR 440.26(1)(c)
(c) Any fluid catalytic cracking unit catalyst regenerator under
par. (b) which commences construction or modification on or before January 17, 1984, is exempted from
sub. (5) (b).
NR 440.26(1)(d)
(d) Any fluid catalytic cracking unit in which a contact material reacts with petroleum derivatives to improve feedstock quality and in which the contact material is regenerated by burning off coke, other deposits, or both and that commences construction or modification on or before January 17, 1984, is exempt from this section.
NR 440.26(1)(e)
(e) For purposes of this section, under
s. NR 440.15, the “fixed capital cost of the new components" includes the fixed capital cost of all depreciable components which are or will be replaced pursuant to all continuous programs of component replacement which are commenced within any 2-year period following January 17, 1984. For purposes of this paragraph, “commenced" means that an owner or operator has undertaken a continuous program of component replacement or that an owner or operator has entered into a contractual obligation to undertake and complete, within a reasonable time, a continuous program of component replacement.
NR 440.26(2)
(2) Definitions. As used in this section, terms not defined in this subsection have the meanings given in
s. NR 440.02.
NR 440.26(2)(a)
(a) “Claus sulfur recovery plant" means a process unit which recovers sulfur from hydrogen sulfide by a vapor-phase catalytic reaction of sulfur dioxide and hydrogen sulfide.
NR 440.26(2)(b)
(b) “Coke burn-off" means the coke removed from the surface of the fluid catalytic cracking unit catalyst by combustion in the catalyst regenerator. The rate of coke burn-off is calculated by the formula specified in
sub. (7).