NR 440.218(7)(h) (h) The owner or operator of an affected facility may conduct a repeat performance test within 30 days of violation of an applicable operating parameter to demonstrate that the affected facility is not in violation of the applicable emission limits. Repeat performance tests conducted pursuant to this paragraph shall be conducted using the identical operating parameters that indicated a violation under par. (e), (f) or (g).
NR 440.218(7)(i) (i) The owner or operator of an affected facility using an air pollution control device other than a dry scrubber followed by a fabric filter, a wet scrubber, or a dry scrubber followed by a fabric filter and a wet scrubber to comply with the emission limits under sub. (3) shall petition the administrator for other site-specific operating parameters to be established during the initial performance test and continuously monitored thereafter. The owner or operator may not conduct the initial performance test until after the petition has been approved by the administrator.
NR 440.218(7)(j) (j) The owner or operator of an affected facility may conduct a repeat performance test at any time to establish new values for the operating parameters. The department may request a repeat performance test at any time.
NR 440.218(8) (8)Monitoring requirements.
NR 440.218(8)(a)(a) The owner or operator of an affected facility shall install, calibrate to manufacturers' specifications, maintain and operate devices, or establish methods, for monitoring the applicable maximum and minimum operating parameters listed in Table 3 such that these devices or methods measure and record values for these operating parameters at the frequencies indicated in Table 3 at all times except during periods of startup and shutdown.
NR 440.218(8)(b) (b) The owner or operator of an affected facility shall install, calibrate to manufacturers' specifications, maintain and operate a device, or establish a method, for measuring the use of the bypass stack including date, time and duration.
NR 440.218(8)(c) (c) The owner or operator of an affected facility using something other than a dry scrubber followed by a fabric filter, a wet scrubber, or a dry scrubber followed by a fabric filter and a wet scrubber to comply with the emission limits under sub. (3) shall install, calibrate to the manufacturers' specifications, maintain and operate the equipment necessary to monitor the site-specific operating parameters developed pursuant to sub. (7) (i).
NR 440.218(8)(d) (d) The owner or operator of an affected facility shall obtain monitoring data at all times during HMIWI operation except during periods of monitoring equipment malfunction, calibration or repair. At a minimum, valid monitoring data shall be obtained for 75% of the operating hours per day and for 90% of the operating days per calendar quarter that the affected facility is combusting hospital waste, medical/infectious waste or both.
NR 440.218(9) (9)Reporting and recordkeeping requirements.
NR 440.218(9)(a)(a) The owner or operator of an affected facility shall submit notifications, as provided by s. NR 440.07. In addition, the owner or operator shall submit the following information:
NR 440.218(9)(a)1. 1. Prior to commencement of construction, all of the following:
NR 440.218(9)(a)1.a. a. A statement of intent to construct.
NR 440.218(9)(a)1.b. b. The anticipated date of commencement of construction.
NR 440.218(9)(a)1.c. c. All documentation produced as a result of the siting requirements of sub. (5).
NR 440.218(9)(a)2. 2. Prior to initial startup, all of the following:
NR 440.218(9)(a)2.a. a. The types of waste to be combusted.
NR 440.218(9)(a)2.b. b. The maximum design waste burning capacity.
NR 440.218(9)(a)2.c. c. The anticipated maximum charge rate.
NR 440.218(9)(a)2.d. d. If applicable, the petition for site-specific operating parameters under sub. (7) (i).
NR 440.218(9)(b) (b) The owner or operator of an affected facility shall maintain the following information, as applicable, for a period of at least 5 years:
NR 440.218(9)(b)1. 1. Calendar date of each record.
NR 440.218(9)(b)2. 2. Records of the following data:
NR 440.218(9)(b)2.a. a. Concentrations of any pollutant listed in sub. (3) or measurements of opacity as determined by the continuous emission monitoring system, if applicable.
NR 440.218(9)(b)2.b. b. Results of fugitive emissions tests by Method 22 of 40 CFR part 60, Appendix A, incorporated by reference in s. NR 440.17 (1), if applicable.
NR 440.218(9)(b)2.c. c. HMIWI charge dates, times, and weights and hourly charge rates.
NR 440.218(9)(b)2.d. d. Fabric filter inlet temperatures during each minute of operation, as applicable.
NR 440.218(9)(b)2.e. e. Amount and type of dioxin/furan sorbent used during each hour of operation, as applicable.
NR 440.218(9)(b)2.f. f. Amount and type of mercury sorbent used during each hour of operation, as applicable.
NR 440.218(9)(b)2.g. g. Amount and type of hydrogen chloride sorbent used during each hour of operation, as applicable.
NR 440.218(9)(b)2.h. h. Secondary chamber temperatures recorded during each minute of operation.
NR 440.218(9)(b)2.i. i. Liquor flow rate to the wet scrubber inlet during each minute of operation, as applicable.
NR 440.218(9)(b)2.j. j. Horsepower or amperage to the wet scrubber during each minute of operation, as applicable.
NR 440.218(9)(b)2.k. k. Pressure drop across the wet scrubber system during each minute of operation, as applicable.
NR 440.218(9)(b)2.L. L. Temperature at the outlet from the wet scrubber during each minute of operation, as applicable.
NR 440.218(9)(b)2.m. m. pH at the inlet to the wet scrubber during each minute of operation, as applicable.
NR 440.218(9)(b)2.n. n. Records indicating use of the bypass stack, including dates, times and durations.
NR 440.218(9)(b)2.o. o. For affected facilities complying with subs. (7) (i) and (8) (c), records of all operating parameter data collected.
NR 440.218(9)(b)3. 3. Identification of calendar days for which data on emission rates or operating parameters specified under subd. 2. have not been obtained, with an identification of the emission rates or operating parameters not measured, reasons for not obtaining the data and a description of corrective actions taken.
NR 440.218(9)(b)4. 4. Identification of calendar days, times and durations of malfunctions, a description of the malfunction and the corrective action taken.
NR 440.218(9)(b)5. 5. Identification of calendar days for which data on emission rates or operating parameters specified under subd. 2. exceeded the applicable limits, with a description of the exceedances, reasons for the exceedances, and a description of corrective actions taken.
NR 440.218(9)(b)6. 6. The results of the initial, annual and any subsequent performance tests conducted to determine compliance with the emission limits or to establish operating parameters, as applicable.
NR 440.218(9)(b)7. 7. All documentation produced as a result of the siting requirements of sub. (5).
NR 440.218(9)(b)8. 8. Records showing the names of HMIWI operators who have completed review of the information in sub. (4) (h) as required by sub. (4) (i), including the date of the initial review and all subsequent annual reviews.
NR 440.218(9)(b)9. 9. Records showing the names of the HMIWI operators who have completed the operator training requirements, including documentation of training and the dates of the training.
NR 440.218(9)(b)10. 10. Records showing the names of the HMIWI operators who have met the criteria for qualification under sub. (4) and the dates of their qualification.
NR 440.218(9)(b)11. 11. Records of calibration of any monitoring devices as required under sub. (8) (a), (b) and (c).
NR 440.218(9)(c) (c) The owner or operator of an affected facility shall submit the information specified in subds. 1. to 3. no later than 60 days following the initial performance test. All reports shall be signed by the facility's manager. The information to be submitted is as follows:
NR 440.218(9)(c)1. 1. The initial performance test data as recorded under sub. (7) (b) 1. to 12., as applicable.
NR 440.218(9)(c)2. 2. The values for the site-specific operating parameters established pursuant to sub. (7) (d) or (i), as applicable.
NR 440.218(9)(c)3. 3. The waste management plan as specified in sub. (6).
NR 440.218(9)(d) (d) An annual report shall be submitted one year following the submission of the information in par. (c) and subsequent reports shall be submitted no more than 12 months following the previous report, except that once the unit is subject to permitting requirements under ch. NR 407, the owner or operator of an affected facility shall submit these reports semiannually. The annual report shall be signed by the facility's manager and shall include all of the following information:
NR 440.218(9)(d)1. 1. The values for the site-specific operating parameters established pursuant to sub. (7) (d) or (i), as applicable.
NR 440.218(9)(d)2. 2. The highest maximum operating parameter and the lowest minimum operating parameter, as applicable, for each operating parameter recorded for the calendar year being reported, pursuant to sub. (7) (d) or (i), as applicable.
NR 440.218(9)(d)3. 3. The highest maximum operating parameter and the lowest minimum operating parameter, as applicable, for each operating parameter recorded pursuant to sub. (7) (d) or (i) for the calendar year preceding the year being reported, in order to provide the department with a summary of the performance of the affected facility over a 2-year period.
NR 440.218(9)(d)4. 4. Any information recorded under par. (b) 3. to 5. for the calendar year being reported.
NR 440.218(9)(d)5. 5. Any information recorded under par. (b) 3. to 5. for the calendar year preceding the year being reported, in order to provide the department with a summary of the performance of the affected facility over a 2-year period.
NR 440.218(9)(d)6. 6. If a performance test was conducted during the reporting period, the results of that test.
NR 440.218(9)(d)7. 7. If no exceedances or malfunctions were reported under par. (b) 3. to 5. for the calendar year being reported, a statement that no exceedances occurred during the reporting period.
NR 440.218(9)(d)8. 8. Any use of the bypass stack, the duration, reason for malfunction and corrective action taken.
NR 440.218(9)(e) (e) The owner or operator of an affected facility shall submit semiannual reports containing any information recorded under par. (b) 3. to 5. no later than 60 days following the reporting period. The first semiannual reporting period ends 6 months following the submission of information in par. (c). Subsequent reports shall be submitted no later than 6 calendar months following the previous report. All reports shall be signed by the facilities manager.
NR 440.218(9)(f) (f) All records specified under par. (b) shall be maintained onsite in either paper copy or computer-readable format, unless an alternative format is approved by the department. - See PDF for table PDF - See PDF for table PDF - See PDF for table PDF
NR 440.218 History History: CR 06-109: cr. Register May 2008 No. 629, eff. 6-1-08.
NR 440.22 NR 440.22Portland cement plants.
NR 440.22(1) (1)Applicability and designation of affected facility.
NR 440.22(1)(a)(a) The provisions of this section are applicable to the following affected facilities in portland cement plants: Kiln, clinker cooler, raw mill system, finish mill system, raw mill dryer, raw material storage, clinker storage, finished product storage, conveyor transfer points, bagging and bulk loading and unloading systems.
NR 440.22(1)(b) (b) Any facility under par. (a) that commences construction or modification after August 17, 1971, is subject to the requirements of this section.
NR 440.22(2) (2)Definitions. As used in this section, terms not defined in this subsection have the meanings given in s. NR 440.02.
NR 440.22(2)(a) (a) “Portland cement plant" means any facility manufacturing portland cement by either the wet or dry process.
NR 440.22(2)(b) (b) “Bypass" means any system that prevents all or a portion of the kiln or clinker cooler exhaust gases from entering the main control device and ducts the gases through a separate control device. This does not include emergency systems designed to duct exhaust gases directly to the atmosphere in the event of a malfunction of any control device controlling kiln or clinker cooler emissions.
NR 440.22(2)(c) (c) “Bypass stack" means the stack that vents exhaust gases to the atmosphere from the bypass control device.
NR 440.22(2)(d) (d) “Monovent" means an exhaust configuration of a building or emission control device, for example a positive-pressure fabric filter, that extends the length of the structure and has a width very small in relation to its length, that is, length to width ratio is typically greater than 5:1. The exhaust may be an open vent with or without a roof, louvered vents or a combination of such features.
NR 440.22(3) (3)Standard for particulate matter.
NR 440.22(3)(a)(a) On and after the date on which the performance test required to be conducted by s. NR 440.08 is completed, no owner or operator subject to the provisions of this section may cause to be discharged into the atmosphere from any kiln any gases which:
NR 440.22(3)(a)1. 1. Contain particulate matter in excess of 0.15 kg per metric ton of feed (dry basis) to the kiln (0.30 lb per ton).
NR 440.22(3)(a)2. 2. Exhibit greater than 20% opacity.
NR 440.22(3)(b) (b) On and after the date on which the performance test required to be conducted by s. NR 440.08 is completed, no owner or operator subject to the provisions of this section may cause to be discharged into the atmosphere from any clinker cooler any gases which:
NR 440.22(3)(b)1. 1. Contain particulate matter in excess of 0.050 kg per metric ton of feed (dry basis) to the kiln (0.10 lb. per ton).
NR 440.22(3)(b)2. 2. Exhibit 10% opacity, or greater.
NR 440.22(3)(c) (c) On and after the date on which the performance test required to be conducted by s. NR 440.08 is completed, no owner or operator subject to the provisions of this section may cause to be discharged into the atmosphere from any affected facility other than the kiln and clinker cooler any gases which exhibit 10% opacity, or greater.
NR 440.22(4) (4)Monitoring of operations.
NR 440.22(4)(a)(a) The owner or operator of any portland cement plant subject to the provisions of this section shall record the daily production rates and kiln feed rates.
NR 440.22(4)(b) (b) Except as provided for in par. (c), each owner or operator of a kiln or clinker cooler that is subject to the provisions of this section shall install, calibrate, maintain and operate in accordance with s. NR 440.13 a continuous opacity monitoring system to measure the opacity of the emissions discharged into the atmosphere from any kiln or clinker cooler. Except as provided for in par. (c), a continuous opacity monitoring system shall be installed on each stack of any multiple stack device controlling emissions from any kiln or clinker cooler. If there is a separate bypass installed, each owner or operator of a kiln or clinker cooler shall also install, calibrate, maintain and operate a continuous opacity monitoring system on each bypass stack in addition to the main control device stack. Each owner or operator of an affected kiln or clinker cooler for which the performance test required under s. NR 440.08 has been completed prior to December 14, 1988, shall install the continuous opacity monitoring system within 180 days after December 14, 1988.
NR 440.22(4)(c) (c) Each owner or operator of a kiln or clinker cooler subject to the provisions of this section using a positive-pressure fabric filter with multiple stacks, or an electrostatic precipitator with multiple stacks may, in lieu of installing the continuous opacity monitoring system required by par. (b), monitor visible emissions at least once per day by using a certified visible emissions observer. If the control device exhausts gases through a monovent, visible emissions observations in lieu of a continuous opacity monitoring system are required. These observations shall be taken in accordance with Method 9 of 40 CFR part 60 Appendix A, incorporated by reference in s. NR 440.17. Visible emissions shall be observed during conditions representative of normal operation. Observations shall be recorded for at least 3 6-minute periods each day. In the event that visible emissions are observed for a number of emission sites from the control device with multiple stacks, Method 9 observations shall be recorded for the emission site with the highest opacity. All records of visible emissions shall be maintained for a period of 2 years.
NR 440.22(4)(d) (d) For the purpose of reports under sub. (6), periods of excess emissions that shall be reported are defined as all 6-minute periods during which the average opacity exceeds that allowed by sub. (3) (a) 2. or (b) 2.
NR 440.22(4)(e) (e) The provisions of pars. (a), (b) and (c) apply to kilns and clinker coolers for which construction, modification or reconstruction commenced after August 17, 1971.
NR 440.22(5) (5)Test methods and procedures.
NR 440.22(5)(a)(a) In conducting the performance tests required in s. NR 440.08, the owner or operator shall use as reference methods and procedures the test methods in Appendix A of 40 CFR part 60, incorporated by reference in s. NR 440.17, or other methods and procedures as specified in this subsection, except as provided in s. NR 440.08 (2).
NR 440.22(5)(b) (b) The owner or operator shall determine compliance with the particulate matter standard in sub. (3) as follows:
NR 440.22(5)(b)1. 1. The emission rate (E) of particulate matter shall be computed for each run using the following equation: - See PDF for diagram PDF