NR 428.23(1)(b)4.4. ‘Continuous monitoring for an output based standard.’ In addition to applicable monitoring and measuring requirements under subd. 2., the owner or operator of an emissions unit subject to an output emission limitation in s. NR 428.22 (1) (d) shall do the following: NR 428.23(1)(b)4.a.a. Install, maintain and operate monitoring equipment for measuring and recording the output on an hourly basis with plus or minus 5% accuracy, in units consistent with the applicable emission limitation. NR 428.23(1)(b)4.b.b. Calculate on an hourly basis, the output based emission rate as the hourly mass of NOx emissions determined according to subd. 5. divided by the emissions unit’s total output for that hour. NR 428.23(1)(b)5.5. ‘Continuous monitoring of total heat input and mass emissions.’ The owner or operator of an emissions unit required to measure total heat input or mass NOx emissions for requirements of subd. 4., sub. (2) (c) and s. NR 428.25 (1) (b) or (c) shall perform the applicable measurements according to following: NR 428.23(1)(b)5.a.a. Except as allowed in subd. 5. d., install, calibrate, maintain and operate a volumetric flue gas flow monitoring system meeting specifications in subd. 2. c. The hourly heat input shall be determined using the F-factor and the as fired fuel heat content according to Method 19 of 40 CFR part 60, Appendix A, incorporated by reference in s. NR 484.04 (16m). NR 428.23(1)(b)5.b.b. Unless specified in Method 19 of 40 CFR part 60, Appendix A, incorporated by reference in s. NR 484.04 (16m), the heat content value for each fuel shall be based on a heat content analysis. NR 428.23(1)(b)5.c.c. The mass of NOx emissions shall be determined on an hourly basis by either multiplying the NOx concentration by the flue gas flow rate corrected for diluent gas and moisture or, by multiplying the monitored hourly average emission rate in mass per mmBtu by the total heat input as determined under subd. 5. a. or b. The calculations of mass emissions are to be performed according to conversion procedures in 40 CFR part 75, Appendix F, incorporated by reference in s. NR 484.04 (26m) (d). NR 428.23(1)(b)5.d.d. For a liquid or gaseous fuel fired system, the total heat input and mass of NOx emissions may be determined using a fuel flow monitoring system capable of determining the hourly flow with plus or minus 5% accuracy and using continuous parametric monitoring as specified under subd. 2. e. The total heat input shall be calculated as the total fuel flow multiplied by the fuel heat content. NR 428.23(1)(b)6.6. ‘General monitoring requirements.’ Unless otherwise specified in this subsection, an owner or operator shall meet the following requirements: NR 428.23(1)(b)6.b.b. The determination of emission rates, mass emissions and total heat input shall be calculated and corrected to the same basis for flue gas moisture and diluent gases according to Method 19 of 40 CFR part 60, Appendix A, incorporated by reference in s. NR 484.04 (16m), or 40 CFR part 75, Appendix F, incorporated by reference in s. NR 484.04 (26m) (d). NR 428.23(1)(b)6.c.c. For emissions units with a common flue gas stack system, all sampling locations and apportionment of emissions to an individual emissions unit shall conform to applicable procedures and methods in 40 CFR part 75, Appendix F, incorporated by reference in s. NR 484.04 (26m) (d). NR 428.23(1)(b)7.7. ‘Malfunction and abatement.’ An owner or operator of an emissions unit subject to the malfunction and abatement plan requirement of s. NR 439.11 shall include a malfunction plan for the emissions monitoring system and a monitoring and operating plan for continuing operation of the emissions unit in a manner consistent with meeting all applicable emission limitations during any period when the monitoring system malfunctions or is inoperable other than for scheduled maintenance. NR 428.23(1)(b)8.8. ‘Alternate emissions monitoring.’ An owner or operator of an emissions unit may request and monitor NOx emissions for compliance determination purposes using an equivalent alternative method to any requirement of this subsection with written approval of the department and the administrator. NR 428.23(1)(b)9.a.a. The owner or operator of an emissions unit that installs and operates a continuous NOx emissions monitoring system according to the requirements of 40 CFR part 75 shall satisfy the applicable monitoring requirements of this section. NR 428.23(1)(b)9.b.b. The owner or operator of an emissions unit that installs and operates a continuous NOx emissions monitoring system according to the requirements of 40 CFR part 60 shall satisfy the applicable monitoring requirements of subd. 3. NR 428.23(2)(2) Compilation of emissions. An owner or operator shall compile the measured emissions data in measurement units consistent with the units of the applicable emission limitation according to the following applicable calculation and tabulation methods for purposes of demonstrating compliance: NR 428.23(2)(a)1.1. The average emission rate shall be the average of the hourly average emissions obtained from the continuous emissions monitoring system for the hours the emissions unit operated during the averaging period. The calculation is as follows: where:
EA is the average emission rate for the compliance period in units consistent with units of the applicable emission limit
EH, j is the hourly average emission rate for each hour, j, for which the emissions unit is operating during the compliance period in units consistent with units of the applicable emission limit
n is the total number of hours the emissions unit operated during the compliance period
NR 428.23(2)(a)2.2. The 30-day rolling period shall consist of the day of monitoring and the previous 29 consecutive calendar days. A new 30-day rolling average emission rate (EA) shall be calculated and recorded at the end of each day. NR 428.23(2)(b)(b) Emissions performance testing. When measuring emissions according to performance testing requirements of sub. (1) (b) 3., the 30-day rolling average emission rate or concentration shall be the emissions determined in sub. (1) (b) 3. d. for the most recent performance test. NR 428.23(2)(c)(c) Multiple fuel-fired emissions units. When measuring emissions for an emissions unit firing multiple fuels, compliance shall be determined according to one of the following methods: NR 428.23(2)(c)1.1. The unit’s emissions shall be monitored and compiled according to applicable methods in par. (a) or (b) for each individual fuel and compliance demonstrated with the emission limitation for each fuel. NR 428.23(2)(c)2.2. The unit’s emissions and a multiple fuel emission limit shall be determined on a total heat input fuel weighted basis according to equation 3. A fuel representing less than 1% of the unit’s annual fuel consumption on a heat input basis may be excluded in determining the multiple fuel emission limit. where:
EHIWeighted is the heat input weighted multiple fuel emission rate or emission limitation for the compliance period in units consistent with the units of the emission limitation
Ef is the emission rate or emission limit for fuel f during the compliance period in units consistent with the units of the emission limitation
HIf is the total heat input for fuel f during the compliance period
n is the number of different fuels used during the compliance period
NR 428.23(2)(d)(d) Total heat input and mass emissions. When measuring hourly heat input or mass of NOx emissions according to sub. (1) (b) 5., the totals over a period of time shall be compiled according to the following procedures: NR 428.23(2)(d)1.1. The total hourly heat input shall be summed for the hours the emissions unit operated during the applicable period of time according to equation 4. where:
HItotal is the total heat input by fuel over the period of time
HIh is the heat input by fuel for hour h
n is the number of hours over which the specific fuel was burned
NR 428.23(2)(d)2.2. The total hourly mass of NOx emissions shall be summed for the hours the emissions unit operated during the applicable period of time according to equation 5. where:
NOx Masstotal is the total mass of NOx emissions over the period of time
Massh is the mass of NOx emissions for hour h
n is the number of hours the emissions unit is operating during the specified period of time
NR 428.23 HistoryHistory: CR 07-016: cr. Register July 2007 No. 619, eff. 8-1-07; CR 08-103: am. (1) (b) 1., cr. (1) (b) 9. Register August 2009 No. 644, eff. 9-1-09. NR 428.24NR 428.24 Recordkeeping and reporting. NR 428.24(1)(1) Emission limitations. The owner or operator of an emissions unit subject to an emission limitation in s. NR 428.22 shall meet the recordkeeping and reporting requirements of this subsection. NR 428.24(1)(a)(a) Recordkeeping. In addition to the recordkeeping requirements of ss. NR 439.04 (1) and (2) and 439.05, the owner or operator shall maintain records of all of the following: NR 428.24(1)(a)1.1. The applicable emission limit and calculated heat input weighted emission limit for an emissions unit demonstrating compliance for multiple fuels. NR 428.24(1)(a)3.3. The total monthly heat input for each fuel or the emissions unit output, as applicable, in measurement units consistent with the units of the applicable emission limitation. NR 428.24(1)(a)4.4. The emissions unit’s annual and ozone season capacity utilization in measurement units consistent with the units of the applicable emission limitation. NR 428.24(1)(a)5.5. For the emissions monitoring system required in s. NR 428.23 (1) (b) on an annual and on an ozone season basis, records of performed maintenance, hours of malfunction and necessary repairs, and the percent of hours the monitoring system operated during the emissions unit’s operating hours. NR 428.24(1)(b)1.1. A certification of compliance with the applicable emission limitation in s. NR 428.22 or identification of the periods of non-compliance, with a quantification of the excess emission rate and the excess mass emissions. NR 428.24(1)(b)2.2. For each calendar month, the highest 30-day rolling average emission rate. The emissions data shall be reported in the measurement units of the applicable emission limitation. NR 428.24(1)(b)3.3. The emissions unit’s annual and ozone season total operating hours, capacity utilization, and the percent operation of any required continuous emissions or combustion monitoring systems during the hours the emissions unit was operating. NR 428.24(1)(c)(c) Secondary fuel usage recordkeeping. The owner or operator claiming exemption from the requirements under s. NR 428.22 pursuant to s. NR 428.22 (3) shall keep a record of all of the following: NR 428.24(2)(2) General exemption unit. The owner or operator of an emissions unit claiming exemption under s. NR 428.21 (1), shall record operational parameters necessary to demonstrate the unit’s qualification for the exemption status. NR 428.24(2m)(2m) Reciprocating engines. The owner or operator of an emissions unit claiming exemption under s. NR 428.21 (2m) (a) 2., shall maintain a record of horsepower-hours of operation for each ozone season. Measurement of horsepower-hours may be determined using recorded data which can be directly related to actual horsepower-hours of operation of the engine including actual total operating hours, fuel consumption, or load and duration measurements. NR 428.24(3)(3) Low operating unit. The owner or operator claiming a low operating unit exemption for an emissions unit under s. NR 428.21 (2), shall maintain a record of the unit’s applicable fuel heat input or production output, as applicable, the unit’s total capacity utilization on an ozone season and on an annual basis for each calendar year and calculations demonstrating the unit’s qualification for the exemption. NR 428.24(4)(4) Other regulated unit. The owner or operator claiming a regulated emissions unit exemption for an emissions unit under s. NR 428.21 (3), shall maintain a record of all performance tests, calculations, assumptions and methods used to determine the emissions unit’s potential emissions. NR 428.24 HistoryHistory: CR 07-016: cr. Register July 2007 No. 619, eff. 8-1-07; CR 08-103: am. (1) (b) (intro.) Register August 2009 No. 644, eff. 9-1-09; CR 23-017: cr. (1) (c) Register March 2024 No. 819, eff. 4-1-24. NR 428.25NR 428.25 Alternative compliance methods and approaches. NR 428.25(1)(1) Emissions averaging. The owner or operator of an emissions unit may demonstrate compliance with an NOx emission limitation in s. NR 428.22 by participating in an emissions rate averaging program according to the general provisions of par. (a) and either the specifications for facility wide averaging in par. (b) or for multi-facility averaging in par. (c). NR 428.25(1)(a)1.a.a. The participation of an emissions unit in an emissions averaging program shall be designated for each calendar year. Individual emissions units may not be withdrawn from an averaging program during a calendar year, unless each emissions unit in the averaging program meets its applicable emission limit in s. NR 428.22. NR 428.25(1)(a)1.b.b. If an emissions unit at a facility participates in an averaging program, all similar units at the facility shall be included in the averaging program unless the unit is complying with an emission limit in s. NR 428.22 or is participating in another emissions averaging program under this subsection. Similar units at a facility are those which serve a similar process or purpose and which are described by the same general source category under s. NR 428.22 without regard to fuel type or unit size threshold. NR 428.25(1)(a)1.c.c. An emissions unit for which the department has approved an alternative emission limit or compliance schedule under sub. (3) may not participate in an emissions averaging program under this subsection for the purpose of demonstrating compliance with the approved alternative emission limitation or compliance schedule. NR 428.25(1)(a)2.2. ‘Monitoring requirement.’ The owner or operator of an emissions unit participating in an emissions averaging program shall monitor all necessary NOx emissions, as applicable, according to requirements of s. NR 428.23 (1) (b) 1. or 2. The total heat input and NOx mass emissions shall be monitored and measured according to s. NR 428.23 (1) (b) 5. and compiled according to s. NR 428.23 (2) (d). NR 428.25(1)(a)3.3. ‘New units.’ An emissions unit which begins operation on or after August 1, 2007 may not participate in an emissions averaging program under this subsection. NR 428.25(1)(a)4.4. ‘Emission reductions.’ For purposes of this subsection, only emission reductions which go beyond all state and federal requirements are considered excess emission reductions. NR 428.25(1)(b)(b) Facility averaging. An owner or operator may average emissions from emissions units at one facility by complying with the following procedures for demonstrating compliance on an annual and on an ozone season basis with an aggregate NOx emission limit and mass emissions cap: NR 428.25(1)(b)1.1. ‘Notification.’ The owner or operator shall submit to the department a notification of an NOx emissions averaging program by October 1 of the year prior to the emissions averaging year. The notification shall include the following information: NR 428.25(1)(b)1.d.d. For a participating emissions unit not subject to s. NR 428.22, the average emission rate by fuel type over the unit’s normal operating range determined according to methods of s. NR 428.23 (1) (b) 3. The tested average emission rate may be adjusted based on a heat input weighted average of the emissions unit’s annual percent operation at different load points in the previous calendar year. NR 428.25(1)(b)1.e.e. For averaging programs effective on or after January 1, 2013, for each emissions unit, the annual and ozone season heat input for 2000 to 2005, and the annual and ozone season average of the 3 years of highest annual heat input for 2000 to 2005.