NR 323.04(1)(c)11.e.
e. Wash equipment with soap and water or high pressure water of not less than 2000 pounds per square inch.
NR 323.04 Note
Note: Additional drying techniques including drying through natural or mechanical means or changes in drying duration may be submitted to the department for review and approval.
NR 323.04(1)(c)11.g.
g. Disinfect equipment with 200 parts per million (0.5 ounces per gallon) chlorine for not less than 10 minute contact time. Every effort should be made to keep the disinfection solution and rinse water out of surface waters.
NR 323.04 Note
Note: Chlorine refers to either household bleach solution (5.25% chlorine) or granular chlorine (70% calcium hypochlorite).
NR 323.04(1)(c)11.h.
h. Follow the most recent department approved disinfection protocols or department approved best management practices for infested waters. The department shall maintain on its website and make available at its offices a list of the most recent disinfection protocols or department approved best management practices for invasive species and viruses.
NR 323.04 Note
Note: See the department's website at dnr.wi.gov under the topic “Waterway and Wetlands". Recommendations for additional disinfection or decontamination protocols or department approved best management practices may be submitted to the department for review and approval to be added to this list.
NR 323.04(1)(d)
(d) Fish crib standards. In addition to the standards in par.
(c), fish cribs shall meet the following requirements:
NR 323.04(1)(d)1.
1. Fish cribs shall have a minimum of 5 feet of water over the top of the structure. The depth and clearance of the fish cribs shall be based on the normal lowest water level condition during a calendar year.
NR 323.04(1)(d)2.
2. Fish cribs shall be constructed of biological materials, with the exception of fastening and anchoring devices.
NR 323.04(1)(d)3.
3. The dimensions of a fish crib shall be no larger than 8 feet tall by 8 feet long by 8 feet wide.
NR 323.04(1)(d)4.
4. Fish cribs may not be placed within 100 feet of swimming beaches or swim rafts.
NR 323.04(1)(d)5.
5. Fish cribs may not be located in soft sediment or muck that is greater than 12 inches in depth.
NR 323.04(1)(d)6.
6. Fish cribs may not be placed where the bottom contour of the waterway exceeds a slope of 4-foot horizontal to one-foot vertical.
NR 323.04(1)(e)
(e) Spawning reef standards
. In addition to the standards in par.
(c), spawning reefs shall meet the following requirements:
NR 323.04(1)(e)1.
1. Spawning reefs shall be constructed of an aggregate of clean, uncrushed gravel and rock from 2 to 8 inches in diameter, in a ratio of approximately 30% ranging from 2 to 4 inches in diameter and approximately 70% ranging from 4.1 to 8 inches in diameter.
NR 323.04(1)(e)2.
2. Spawning reefs shall be placed in a linear form parallel to the shore.
NR 323.04(1)(e)3.
3. Spawning reefs shall be no longer than 100 feet along the shoreline and no wider than 30 feet perpendicular to shore and may not be placed more than 100 feet from shore.
NR 323.04(1)(e)4.
4. Spawning reefs shall be placed where water depths range from 0 to 5 feet.
NR 323.04(1)(e)5.
5. Spawning reefs may not be placed where the bottom contour of the waterway exceeds a slope of 4-foot horizontal to one-foot vertical.
NR 323.04(1)(e)6.
6. Spawning reefs may not be placed where the bottom substrate composition consists of less than 90% clean sand.
NR 323.04 Note
Note: Natural walleye spawning reefs generally consist of substrates 2-8 inches in diameter with rounded edges. Natural walleye spawning reefs are located adjacent to gently sloping shorelines in shallow water. Walleye spawning reefs require a moderate amount of wave action to keep the substrate clean of algae and provide adequate water circulation for incubating eggs. The requirement of 90% clean sand indicates a lack of spawning habitat, the appropriate wave action, and substrate capable of supporting the reef. If the water depth remains less than 5 feet and the bottom contour remains less than 10:1, a maximum location of 100 feet from shore is required to reduce navigation concerns.
NR 323.04(1)(e)7.
7. Any person placing a spawning reef shall, within 30 days after placement, provide written notice to the president or chair of any lake association, property owners association or lake district. The notice shall include a description of the spawning reef and include a lake map identifying the exact location of the reef. The person is also responsible for posting a laminated copy of the same map, within 30 days after placement, at all public boat landings on the waterbody, where the reef is located, for a period of not less than one year.
NR 323.04(1)(f)
(f) Wing deflector standards. In addition to the standards in par.
(c), wing deflectors shall meet the following requirements:
NR 323.04(1)(f)1.
1. Design and placement of wing deflectors shall follow the recommendations in
Guidelines for Management of Trout Stream Habitat in Wisconsin by Ray J. White and Oscar M. Brynildson, Wisconsin Department of Natural Resources.
NR 323.04 Note
Note: Copies of these publications may be inspected by contacting the local department fisheries biologist or public library.
NR 323.04(1)(f)2.
2. Wing deflectors may only be placed in navigable streams which are less than 5 feet wide, measured from ordinary high water mark to ordinary high water mark.
NR 323.04(1)(f)3.
3. Wing deflectors may not extend more than 25% across the stream width.
NR 323.04(1)(g)
(g) Tree drops. In addition to the standards in par.
(c), tree drops shall meet the following requirements:
NR 323.04(1)(g)2.
2. Tree drops shall consist of fresh cut live trees having a minimum diameter of 12 inches at the base.
NR 323.04(1)(g)3.
3. Tree drops shall be securely anchored to the shore at intervals no less than 50 feet apart.
NR 323.04 Note
Note: Local zoning ordinances may place restrictions on cutting trees in the shoreland zone. The riparian is responsible for ensuring that their tree drop project is in compliance with any local zoning requirements.
NR 323.04(1)(h)
(h) Half-log structures. In addition to the standards in par.
(c), half log structures shall meet the following requirements:
NR 323.04(1)(h)1.
1. Half-logs shall be constructed from green logs with a minimum diameter of 10 inches and spacers may not exceed 12 inches in height.
NR 323.04(1)(h)2.
2. Half-logs shall be placed where the bottom substrate composition consists of sand or gravel, or both.
NR 323.04(1)(h)4.
4. Half-logs placed in lakes and flowages may not be located greater than 100 feet from shore or within 100 feet of a swim raft.
NR 323.04(1)(i)1.1. Activities which do not meet the standards in par.
(c) and either par.
(d),
(e),
(f),
(g) or
(h), or are otherwise determined ineligible for an exemption by the department shall require a general permit or individual permit.
NR 323.04(2)(a)2.
2. If the department determines that a proposal submitted under this section has the potential to impact an endangered or threatened species in accordance with s.
29.604, Stats., the application shall be deemed incomplete. The department may not consider the application complete or issue a general permit until the applicant submits documentation to demonstrate one of the following:
NR 323.04(2)(a)2.a.
a. The project avoids impacts to the endangered or threatened species in accordance with s.
29.604, Stats.
NR 323.04(2)(a)3.
3. If the applicant modifies the project plans to meet the requirements of subd.
2., the modified plans shall be submitted before the department may consider the application complete or issue a general permit.
NR 323.04(2)(b)
(b) Applicable activities. A fish habitat structure that meets the standards in par.
(c) shall be eligible for a general permit under ss.
30.12 (3) (d) and
30.206, Stats.
NR 323.04 Note
Note: Eligibility for an exemption or general permit does not automatically result in a federal permit or state water quality certification for fill in wetlands. Some projects involving minimal wetland fill may be eligible for authorization under a U.S. Army Corps of Engineers general permit which has already been granted state water quality certification or a general permit under s.
281.36 (3g) (b), Stats. (under development) All other projects affecting wetlands will require individual water quality certification including public notice as required by s. 401, Federal Clean Water Act, and s.
281.36 (3b) (b), Stats., and carried out under chs.
NR 103 and
299. For further instructions, see the department's website at
http://dnr.wi.gov under the topic “Waterway and Wetland Permits."
NR 323.04(2)(c)1.1. A fish habitat structure may be authorized under a general permit if it meets all the requirements in sub.
(1), except for sub.
(1) (c) 1., and all the requirements of this paragraph.
NR 323.04(2)(c)2.
2. Erosion control measures shall meet or exceed the technical standards for erosion control approved by the department under subch.
V of ch. NR 151. Any area where topsoil is exposed during construction shall be immediately seeded and mulched or riprapped to stabilize disturbed areas and prevent soils from being eroded and washed into the waterway.
NR 323.04(2)(c)3.
3. Unless part of a permanent stormwater management system, all temporary erosion and sediment control practices shall be removed upon final site stabilization. Areas disturbed during construction or installation shall be restored.
NR 323.04(2)(c)4.
4. To protect fish habitat during spawning seasons, no general permit activity may take place during the time period specified:
NR 323.04(2)(c)4.a.
a. For trout streams identified under s.
NR 1.02 (7) and perennial tributaries to those trout streams, September 15 through May 15.
NR 323.04(2)(c)4.b.
b. For all waters not identified under subd.
4. a. and located south of state highway 29, March 15 through May 15.
NR 323.04(2)(c)4.c.
c. For all waters not identified under subd.
4. a. and located north of state highway 29, April 1 through June 1.
NR 323.04(2)(c)4.d.
d. The applicant may request that the requirements in subd.
4. a.,
b. or
c. be waived by the department on a case-by-case basis, by submitting a written statement signed by the local department fisheries biologist, documenting consultation about the proposed project, and that the local department fisheries biologist has determined that the requirements of this paragraph are not necessary to protect fish spawning for the proposed project.
NR 323.04(2)(c)5.
5. To stop the spread of invasive species and viruses from one navigable waterway to another navigable waterway, all equipment or portions of equipment used for constructing, operating, or maintaining the project, including tracked vehicles, barges, boats, silt or turbidity curtains, hoses, sheet piles, and pumps, shall be decontaminated for invasive species and viruses before and after use or prior to use within another navigable waterway. Decontamination activities shall be performed by taking actions specified in subd.
5. a. to
c. or
h. Decontamination shall include either subd.
5. d.,
e.,
f.,
g., or
h. for any equipment, or portions of equipment, that is used in non-frozen navigable waters when the air temperature is above 19 degrees Fahrenheit at the time the decontamination procedures take place.
NR 323.04(2)(c)5.a.
a. Inspect all equipment used for constructing, operating, or maintaining the project and remove all plants and animals, and other mud, debris, etc.
NR 323.04 Note
Note: This does not apply to water in closed engine cooling systems or water tanks, or containers of potable drinking water or other beverages meant for human consumption. If a tanker truck discharges water collected from navigable waters in upland areas, the tank does not require disinfection.
NR 323.04(2)(c)5.c.
c. Dispose of plants and animals in the trash. An operator may not transfer plants or animals or water from one navigable waterway to another.
NR 323.04(2)(c)5.d.
d. Wash equipment at a temperature of not less than 212 degrees Fahrenheit water (steam clean).
NR 323.04(2)(c)5.e.
e. Wash equipment with soap and water or high pressure water of not less than 2000 pounds per square inch.
NR 323.04 Note
Note: Additional drying techniques including drying through natural or mechanical means or changes in drying duration may be submitted to the department for review and approval.
NR 323.04(2)(c)5.g.
g. Disinfect equipment with 200 parts per million (0.5 ounces per gallon) chlorine for not less than 10 minute contact time. Every effort should be made to keep the disinfection solution and rinse water out of surface waters.
NR 323.04 Note
Note: Chlorine refers to either household bleach solution (5.25% chlorine) or granular chlorine (70% calcium hypochlorite).
NR 323.04(2)(c)5.h.
h. Follow the most recent department approved disinfection protocols or department approved best management practices for infested waters. The department shall maintain on its website and make available at its offices a list of the most recent disinfection protocols or department approved best management practices for invasive species and viruses.
NR 323.04 Note
Note: See the department's website at dnr.wi.gov under the topic “Waterway and Wetlands". Recommendations for additional disinfection or decontamination protocols or department approved best management practices may be submitted to the department for review and approval to be added to this list.
NR 323.04(2)(d)1.1. Activities which do not meet the applicable standards in par.
(c) shall require an individual permit.
NR 323.04(2)(d)2.
2. The department has authority under s.
30.206 (3r), Stats., to require an individual permit in lieu of a general permit.
NR 323.04(3)(a)2.
2. If the department determines that a proposal submitted under this section has the potential to impact an endangered or threatened species in accordance with s.
29.604, Stats., the application shall be deemed incomplete. The department may not consider the application complete or issue an individual permit until the applicant submits documentation to demonstrate one of the following:
NR 323.04(3)(a)2.a.
a. The project avoids impacts to the endangered or threatened species in accordance with s.
29.604, Stats.
NR 323.04(3)(a)3.
3. If the applicant modifies the project plans to meet the requirements of subd.
2., the modified plans shall be submitted before the department may consider the application complete or issue an individual permit.
NR 323.04(3)(b)
(b) Applicable activities. A fish habitat structure which is not exempt under sub.
(1) and is not authorized by a general permit under sub.
(2) requires authorization by an individual permit pursuant to s.
30.12 (3m) (c), Stats.
NR 323.04(3)(c)
(c) Standards. A fish habitat structure meeting the standards in s.
30.12 (3m), Stats., may be authorized under an individual permit.
NR 323.04(4)
(4)
Existing permits. A fish habitat structure which is authorized by an existing department permit shall continue to be authorized, provided the structure is maintained in compliance with all the conditions of the original permit. Any modifications to the structure that do not comply with the original permit conditions shall require a new individual permit and shall comply with all standards in this section.
NR 323.04 History
History: CR 04-064: cr.
Register April 2005 No. 592, eff. 5-1-05;
CR 07-094: cr. (1) (c) 11. and (2) (c) 5.
Register November 2008 No. 635, eff. 12-1-08; correction in (2) (b) made under s.
13.92 (4) (b) 7., Stats.,
Register May 2013 No. 689;
CR 22-013: am. (1) (a), (2) (a) 1., (3) (a) 1. Register June 2023 No. 810, eff. 7-1-23.
NR 323.05
NR 323.05 Wildlife habitat structures.