NR 290.03 History
History: Cr.
Register, October, 1986, No. 370, eff. 11-1-86.
NR 290.10
NR 290.10
Applicability. The provisions in this subchapter are applicable to discharges of wastewater from the steam electric power generating category of point sources into waters of the state.
NR 290.11
NR 290.11 Compliance dates. Discharge of pollutants from facilities subject to the provisions of this subchapter may not exceed, as appropriate:
NR 290.11(1)
(1) By July 1, 1977, effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT);
NR 290.11(2)
(2) By July 1, 1984, effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT);
NR 290.11(3)
(3) At the commencement of discharge, new source performance standards (NSPS).
NR 290.11 History
History: Cr.
Register, October, 1986, No. 370, eff. 11-1-86.
NR 290.12(1)
(1)
Best practicable technology. The following effluent limitations and standards for all or specific wastewater flows establish, except as provided in subch.
IV of ch. NR 220, the quantity or quality of pollutants or pollutant properties which may be discharged by a facility subject to the provisions of this chapter after application of the best practicable control technology currently available:
NR 290.12 Note
Note: Despite this reference, federal regulations in
40 CFR 125.30 and state regulations in s.
NR 220.31 (3) state that steam electric power generators are ineligible to receive a fundamentally different factors variance for BPT limitations.
NR 290.12(1)(a)
(a) The pH of all discharges, except once through cooling water, shall be within the range of 6.0 to 9.0. Dischargers which continuously monitor pH shall be subject to
s. NR 205.06.
NR 290.12(1)(b)
(b) There may be no discharge of polychlorinated biphenyl compounds such as those commonly used for transformer fluid.
NR 290.12(1)(c)
(c) The quantity of pollutants in each of the wastewater sources identified in Table 1 may not exceed the quantity determined by multiplying the flow by the concentration of each pollutant listed in Table 1.
NR 290.12(1)(d)
(d) Neither free available chlorine nor total residual chlorine may be discharged from any unit for more than 2 hours in any one day and not more than one unit in any plant may discharge free available or total residual chlorine at any one time unless the utility can demonstrate to the department that the units in a particular location cannot operate at or below this level of chlorination.
NR 290.12(1)(e)
(e) In the event that wastestreams from various sources are combined for treatment or discharge, the quantity of each pollutant or pollutant property limited in
pars. (a) to
(d) attributable to each regulated stream except coal pile runoff may not exceed the specified limitation for that waste source.
NR 290.12(1)(f)
(f) Any untreated discharge from facilities designed, constructed, and operated to treat the volume of coal pile runoff which is associated with a 10 year, 24 hour rainfall event may not be subject to the limitations of
par. (c).
NR 290.12(1)(g)
(g) Where the department determines there is no need for a restriction on the mass of pollutants discharged, the quantity of any pollutant allowed to be discharged may be expressed as a concentration limitation instead of the mass limitation required to be calculated by
par. (c). Concentration limitations shall be those concentrations specified in this subsection.
-
See PDF for table NR 290.12(2)
(2) Best available technology. The following effluent limitations and standards for all or specific wastewater flows establish the quantity or quality of pollutants or pollutant properties which may be discharged by a facility subject to the provisions of this chapter after application of the best available technology economically achievable:
NR 290.12(2)(a)
(a) There may be no discharge of polychlorinated biphenyl compounds such as those commonly used for transformer fluid.
NR 290.12(2)(b)
(b) The quantity of pollutants in each of the wastewater sources identified in Table 2 may not exceed the quantity determined by multiplying the flow by the concentration of each pollutant listed in that table.
NR 290.12(2)(c)
(c) For any plant with a total rated electric generating capacity of 25 or more megawatts discharging once through cooling water, total residual chlorine may not be discharged from any single generating unit for more than 2 hours per day unless the utility demonstrates to the department that discharge for more than 2 hours is required for macroinvertebrate control. Simultaneous multi-unit chlorination is permitted.
NR 290.12(2)(d)
(d) For any plant with a total rated generating capacity of less than 25 megawatts discharging once through cooling water and for plants of any size discharging cooling tower blowdown, neither free available chlorine nor total residual chlorine may be discharged from any unit for more than 2 hours in any one day and not more than one unit in any plant may discharge free available or total residual chlorine at any one time unless the utility can demonstrate to the department that the units in a particular location cannot operate at or below this level of chlorination.
NR 290.12(2)(e)
(e) Where the discharger requests and the department approves in writing, instead of monitoring cooling tower blowdown, compliance with the limitations for the 126 priority pollutants may be determined by engineering calculations which demonstrate that the regulated pollutants are not present or are present in the final discharge in no detectable amount.
NR 290.12(2)(f)
(f) Where the department determines there is no need for a restriction on the mass of pollutants discharged, the quantity of any pollutant allowed to be discharged may be expressed as a concentration limitation instead of the mass limitation required to be calculated by
par. (b). Concentration limitations shall be those concentrations specified in this subsection.
NR 290.12(2)(g)
(g) In the event that wastestreams from various sources are combined for treatment or discharge, the quantity of each pollutant or pollutant property controlled in
pars. (a) to
(e) attributable to each regulated stream may not exceed the specified limitations for that waste source.
-
See PDF for table NR 290.12(3)
(3) New source performance standards (NSPS). The following effluent limitations and standards for all or specific subcategories establish the quantity or quality of pollutants or pollutant properties which may be discharged by a facility which is a new source subject to the provisions of this chapter:
NR 290.12(3)(a)
(a) The pH of all discharges, except once through cooling water shall be within the range of 6.0 to 9.0. Dischargers which continuously monitor pH shall be subject to
s. NR 205.06.
NR 290.12(3)(b)
(b) There may be no discharge of polychlorinated biphenyl compounds such as those commonly used for transformer fluid.
NR 290.12(3)(c)
(c) The quantity of pollutants in each of the wastewater sources identified in Table 3 may not exceed the quantity determined by multiplying the flow by the concentration of each pollutant listed in that table.
NR 290.12(3)(d)
(d) For any plant with a total rated electric generating capacity of 25 or more magawatts discharging once through cooling water, total residual chlorine may not be discharged from any single generating unit for more than 2 hours per day unless the utility demonstrates to the department that discharge for more than 2 hours is required for macroinvertebrate control. Simultaneous multi-unit chlorination is permitted.
NR 290.12(3)(e)
(e) For any plant with a total rated electric generating capacity of less than 25 magawatts discharging once through cooling water and for plants of any size discharging cooling tower blowdown, neither free available chlorine nor total residual chlorine may be discharged from any unit for more than 2 hours in any one day and not more than one unit in any plant may discharge free available or total residual chlorine at any one time unless the utility can demonstrate to the department that the units in a particular location cannot operate at or below this level of chlorination.
NR 290.12(3)(f)
(f) Where the discharger requests and the department approves in writing, instead of monitoring cooling tower blowdown, compliance with the limitations for the 126 priority pollutants may be determined by engineering calculations which demonstrate that the regulated pollutants are not present or are present in the final discharge in no detectable amount.
NR 290.12(3)(g)
(g) Where the department determines there is no need for a restriction on the mass of pollutants discharged, the quantity of any pollutant allowed to be discharged may be expressed as a concentration limitation instead of the mass limitation required to be calculated by
par. (c). Concentration limitations shall be those concentrations specified in this subsection.
NR 290.12(3)(h)
(h) In the event that wastestreams from various sources are combined for treatment or discharge, the quantity of each pollutant or pollutant property controlled in
pars. (a) to
(f) attributable to each regulated stream except coal pile runoff may not exceed the specified limitation for that waste source.
NR 290.12(3)(i)
(i) Any untreated discharge from facilities designed, constructed, and operated to treat the volume of coal pile runoff which is associated with a 10 year, 24 hour rainfall event may not be subject to the limitations of
par. (c).
-
See PDF for table NR 290.12 History
History: Cr.
Register, October, 1986, No. 370, eff. 11-1-86;
correction in (1) (intro.) made under s. 13.92 (4) (b) 7, Stats., Register April 2018 No. 748.
NR 290.20
NR 290.20
Applicability. The provisions in this subchapter are applicable to discharges of wastewater from the steam electric power generating category of point sources into publicly owned treatment works.
NR 290.20 History
History: Cr.
Register, October, 1986, No. 370, eff. 11-1-86.
NR 290.21
NR 290.21
Compliance dates. Discharge of pollutants from facilities subject to the provisions of this subchapter may not exceed, as appropriate:
NR 290.21(1)
(1) By July 1, 1984 for pretreatment standards for existing sources;
NR 290.21(2)
(2) At the commencement of discharge for pretreatment standards for new sources.
NR 290.21 History
History: Cr.
Register, October, 1986, No. 370, eff. 11-1-86.
NR 290.22(1)
(1)
Pretreatment standards for existing sources (PSES
). Except as provided in
s. NR 211.13 any existing source subject to this section which introduces pollutants into a publicly owned treatment works shall comply with
ch. NR 211 and achieve the following pretreatment standards for existing sources by July 1, 1984.
NR 290.22(1)(a)
(a) There shall be no discharge of polychlorinated biphenyl compounds such as those used for transformer fluid.
NR 290.22(1)(b)
(b) The quantity of pollutants in each of the wastewater sources identified in Table 4 may not exceed the concentration listed in that table.
NR 290.22(1)(c)
(c) Where the discharger requests and the control authority approves in writing, instead of monitoring cooling tower blowdown, compliance with the limitations for the 126 priority pollutants may be determined by engineering calculations which demonstrate that the regulated pollutants are not present or are present in the final discharge in no detectable amount.
NR 290.22(2)
(2) Pretreatment standards for new sources (
PSNS). Except as provided in
s. NR 211.13 any new source subject to this section which introduces pollutants into a publicly owned treatment works shall comply with
ch. NR 211 and the following pretreatment standards for new sources:
NR 290.22(2)(a)
(a) There may be no discharge of polychlorinated biphenyl compounds such as those used for transformer fluid.
NR 290.22(2)(b)
(b) The quantity of pollutants in each of the wastewater sources identified in Table 4 may not exceed the concentration listed in that table.
NR 290.22(2)(c)
(c) Where the discharger requests and the control authority approves in writing, instead of monitoring cooling tower blowdown, compliance with the limitations for the 126 priority pollutants may be determined by engineering calculations which demonstrate that the regulated pollutants are not present or are present in the final discharge in no detectable amount.
NR 290.22 History
History: Cr.
Register, October, 1986, No. 370, eff. 11-1-86.