(c) Fire inspections. The administrator of the facility shall arrange for fire protection as follows:
1. At least semiannual inspection of the facility shall be made by the local fire inspection authorities. Signed certificates of such inspections shall be kept on file in the facility.
2. Certification by the local fire authority as to the fire safety of the facility and to the adequacy of a written fire plan for orderly evacuation of residents shall be obtained and kept on file in the facility.
3. Where the facility is located in a city, village, or township that does not have an official established fire department, the licensee shall obtain and maintain a continuing contract for fire protection service with the nearest municipality providing such service. A certification of the existence of such contract shall be kept on file in the facility.
Note: See NFPA 10, 1973 edition.
(e) Fire report. All incidents of fire in a facility shall be reported to the department within 72 hours.
History: Cr. Register, July, 1982, No. 319, eff. 8-1-82; r. and recr. (1) and (2), r. (4), renum. (3) and (5) to be (4) and (6), cr. (3) and (5), Register, January, 1987, No. 373, eff. 2-1-87; emerg. am. (3), cr. (3m), r. and recr. (5) and Table, eff. 7-1-94; am. (3), cr. (3m), r. and recr. (5) and Table, Register, January, 1995, No. 469, eff. 2-1-95; CR 04-053: r. and recr. (1) to (5), renum. (6) to be (3) Register October 2004 No. 586, eff. 11-1-04; CR 06-053: r. (3) (d) and (f) to (i), Register August 2007 No. 620, eff. 9-1-07; CR 16-087: am. (1) Register September 2017 No. 741, eff. 10-1-17.
DHS 132.83Safety and systems.
(1)Maintenance. The building shall be maintained in good repair and kept free of hazards such as those created by any damaged or defective building equipment.
(3)Doors.
(d) Toilet room doors. In period B and C facilities, resident toilet room doors shall be not less than 3 feet 0 inches by 6 feet 8 inches, and shall not swing into the toilet room unless they are provided with two-way hardware.
(e) Thresholds. In period B and C facilities, raised thresholds which cannot be traversed easily by a bed on wheels, a wheelchair, a drug cart, or other equipment on wheels shall not be used.
(4)Emergency power. Emergency electrical service with an independent power source which covers lighting at nursing stations, telephone switchboards, exit and corridor lights, boiler room, fire alarm systems, and medical records when solely electronically based, shall be provided. The service may be battery operated if effective for at least 4 hours.
(7)Mechanical systems.
(a) Water supply.
1. A potable water supply shall be maintained at all times. If a public water supply is available, it shall be used. If a public water supply is not available, the well or wells shall comply with ch. NR 812.
2. An adequate supply of hot water shall be available at all times. The temperature of hot water at plumbing fixtures used by residents may not exceed the range of 110-115°F.
(d) Heating and air conditioning. The heating and air conditioning systems shall be capable of maintaining adequate temperatures and providing freedom from drafts.
(g) General lighting. Period C facilities shall have night lighting.
(h) Ventilation.
5. In period C facilities all rooms in which food is stored, prepared or served, or in which utensils are washed shall be well-ventilated. Refrigerated storage rooms need not be ventilated.
(i) Elevators.
1. In period B facilities, at least one elevator shall be provided when residents’ beds are located on one or more floors above or below the dining or service floor. The platform size of the elevator shall be large enough to hold a resident bed and attendant.
2. In period C facilities, at least one elevator shall be provided in the facility if resident beds or activities are located on more than one floor. The platform size of the elevator shall be large enough to hold a resident bed and an attendant.
(j) Electrical.
2. In period B and C facilities at least one duplex-type outlet shall be provided for every resident’s bed.
3. In new construction begun after the effective date of this chapter, at least 2 duplex-type outlets shall be provided for each bed.
History: Cr. Register, July, 1982, No. 319, eff. 8-1-82; am. (3) (c) 1., (5) (e) and (f) (intro), (6) (b), (7) (a), (f), (g) 1., (j) 2., Register, January, 1987, No. 373, eff. 2-1-87; emerg. am. (6) (a), r. and recr. (6) (b), eff. 7-1-94; am. (6) (a), r. and recr. (6) (b), Register, January, 1995, No. 469, eff. 2-1-95; CR 04-053: am. (4) and (7) (a) 2., r. (5) (b), (c) and (d), Register October 2004 No. 586, eff. 11-1-04; CR 06-053: r. (2) (3) (a) to (c), (5), (6), (7) (b), (c), (d) 2., (e), (f), (g) 1., (h) 1. to 4. and 5. a., and (j) 1. and 2. b., renum. (7) (d) 1. and (g) 2. to be (7) (d) and (g), cons., renum. and am. (7) (h) 5. (intro.) and b. to be &(7) (h) 5., cons., renum. and am. (7) (j) 2. (intro.) and a. to be (7) (j) 2., Register August 2007 No. 620, eff. 9-1-07.
DHS 132.84Design.
(1)Residents’ rooms.
(a) Assignment of residents. Sexes shall be separated by means of separate wings, floors, or rooms, except in accordance with s. 50.09 (1) (f) 1, Stats.
(b) Location. No bedroom housing a resident shall open directly to a kitchen or laundry.
(g) Bed arrangement. The beds shall be arranged so that the beds shall be at least 3 feet apart and a clear aisle space of at least 3 feet from the entrance to the room to each bed shall be provided.
(h) Closet space. A closet or locker shall be provided for each resident in each bedroom. Closets or lockers shall afford a space of not less than 15 inches wide by 18 inches deep by 5 feet in height for each resident bed.
(i) Cubicle curtains.
1. In period A and B facilities, each bed in a multiple-bed room shall have a flameproof cubicle curtain or an equivalent divider that will assure resident privacy.
2. In period C facilities, each bed in a multiple-bed room shall be provided with a flameproof cubicle curtain to enclose each bed and to assure privacy.
(2)Toilet and bathing facilities.
(a) General. All lavatories required by this subsection shall have hot and cold running water. Toilets shall be water flushed and equipped with open front seats without lids.
(e) Period A and B. In period A and B facilities separate toilet and bath facilities shall be provided for male and female residents.
(f) Period C. In period C facilities every tub, shower, or toilet shall be separated in such a manner that it can be used independently and afford privacy.
(3)Staff work stations and other required facilities. Each resident living area shall have all of the following:
(a) A staff work station whose location allows staff to provide services to all living areas, resident bedrooms and resident use spaces. The facility shall contain adequate storage space for records and charts and shall contain a desk or work counter for staff, a functional telephone for emergency calls and a resident communication system as required under sub. (4). Staff work stations shall be located to meet the needs of the resident population being served.
(b) Space for storage of linen, equipment and supplies, unless a central space for storage is provided.
1. Except as provided in subds. 2. and 3., a well-lit, secure medicine preparation, storage and handling room or area available to each staff work station with a work counter, refrigerator, sink with hot and cold running water, and a medicine storage cabinet with lock or space for drug carts. The room shall be mechanically ventilated.
2. In period A nursing homes, a well-lit medicine preparation, storage and handling area equipped with a sink and hot and cold running water may continue to be used. Mechanical ventilation is not required.
3. In period B nursing homes, cart storage space and mechanical ventilation within the medicine preparation room are not required.
1. Except as provided in subds. 2., 3. and 4., a soiled utility room central to each resident sleeping room wing or module that is equipped with a flush-rim siphon jet service sink, a facility for sanitizing bedpans, urinals, emesis basins, thermometers and related nursing care equipment, appropriate cabinet and counter space, and sink with hot and cold running water. The room shall be mechanically ventilated and under negative pressure.
2. Period A nursing homes shall have a utility room that shall be located, designed and equipped to provide areas for the separate handling of clean and soiled linen, equipment, and supplies.
3. Period B nursing homes shall have a ventilated utility room with a flush-rim service sink.
4. Central location of soiled utility rooms is not required in existing nursing homes.
1. Except as provided in subd. 2., a clean utility area or room central to each resident sleeping room wing or module that is equipped with a sink with hot and cold running water, counter, and cabinets for storage of clean utensils and equipment.
2. Period A and B nursing homes shall have a utility room located, designed and equipped to provide areas for the separate handling of clean and soiled linen, equipment and supplies.
(f) Period C nursing homes shall have staff toilet and hand-washing facilities separate from those used by residents.
(g) Period C nursing homes shall have a nourishment station with sink, hot and cold running water, refrigerator and storage for serving between-meal nourishment if a kitchen is not open at all times. Nourishment stations may serve more than one nursing area but not more than a single floor.
(4)Resident and staff communication.
(a) Except as provided in pars. (b) and (c), the nursing home shall have a department-approved resident and staff communication system comprised of components listed by an independent testing laboratory to permit each resident to activate the call from resident rooms, toilet area, bathing areas, and activity areas. Nurse calls shall be visible from corridor or access aisles within each resident living area and an audible sounder shall annunciate upon failure of staff response. The communication signal emanating from the toilet, bath and shower areas shall be that of a distinctive emergency call. The activation device shall be reachable by the residents from each toilet, bath or shower location.
Note: Underwriter’s Laboratory (UL) is an example of an independent testing laboratory.
(b) Nursing homes in existence November 1, 2004, may continue using a nurse call system that registers calls from each resident bed, resident toilet room and each tub and shower area. In addition, in period B and C nursing homes, the resident staff signal may register in the corridor directly outside the room and at the staff work station.
(c) In all nursing homes in existence November 1, 2004, the nursing home may retain use of non-source signal canceling equipment until any remodeling is undertaken within the smoke compartment where the equipment is located.
(d) Communication systems shall be functioning at all times.
(6)Food service.
(a) General. The facility shall have a kitchen or dietary area which shall be adequate to meet food service needs and shall be arranged and equipped for the refrigeration, storage, preparation, and serving of food, as well as for dish and utensil cleaning and refuse storage and removal. Dietary areas shall comply with the local health or food handling codes. Food preparation space shall be arranged for the separation of functions and shall be located to permit efficient services to residents and shall not be used for nondietary functions.
Note: The department encourages and supports gerontological design principles that promote innovation and a diversity of approaches.
(15)Mixed occupancy. Rooms or areas within the facility may be used for occupancy by individuals other than residents and facility staff if the following conditions are met:
(a) The use of these rooms does not interfere with the services provided to the residents; and
(b) The administrator takes reasonable steps to ensure that the health, safety and rights of the residents are protected.
(17)Submission of plans and specifications. For all new construction:
(a) One copy of schematic and preliminary plans shall be submitted to the department for review and approval of the functional layout.
(b) One copy of working plans and specifications shall be submitted to and approved by the department before construction is begun. The department shall notify the facility in writing of any divergence in the plans and specifications, as submitted, from the prevailing rules.
(c) The plans specified in pars. (a) and (b) shall show the general arrangement of the buildings, including a room schedule and fixed equipment for each room and a listing of room numbers, together with other pertinent information. Plans submitted shall be drawn to scale.
(d) Any changes in the approved working plans affecting the application of the requirements herein established shall be shown on the approved working plans and shall be submitted to the department for approval before construction is undertaken. The department shall notify the facility in writing of any divergence in the plans and specifications, as submitted, from the prevailing rules.
(e) If on-site construction above the foundation is not started within 6 months of the date of approval of the working plans and specifications under par. (b), the approval shall be void and the plans and specifications shall be resubmitted for reconsideration of approval.
(f) If there are no divergences from the prevailing rules, the department shall provide the facility with written approval of the plans as submitted.
History: Cr. Register, July, 1982, No. 319, eff. 8-1-82; am. (3) (b) 2. and (13) (c), renum. (15) and (16) to be (16) and (17), cr. (15), Register, January, 1987, No. 373, eff. 2-1-87; am. (1) (b) 2., (2) (e) 1. c. and (5) (a); CR 04-053: r. and recr. (3) and (4) and am. (6) (d) 12. Register October 2004 No. 586, eff. 11-1-04; CR 06-053: am. (1) (a), r. (1) (b) 2. and 3., (c), (d), (e), (f), (j), (k), (2) (b) to (d), (e) 1. a. to d. and 2., (f) 1. to 3., 5., (g), (5) (6) (b) to (d), (7) to (14) and (16), cons., renum. and am. (1) (b) (intro.) and 1. to be (1) (b), cons., renum., and am. (2) (e) (intro.) and 1. (intro.) to be (2) (e), cons., renum. and am. (2) (f) (intro.) and 4. to be (2) (f), Register August 2007 No. 2007, eff. 9-1-07.