NR 465.42(20) (20) “General use coating" means any material that meets the definition of coating but does not meet the definition of high performance coating, rubber-to-metal coating, magnet wire coating or extreme performance fluoropolymer coating.
NR 465.42(21) (21) “High performance architectural coating" means any coating applied to architectural subsections which is required to meet the specifications of American Architectural Manufacturer Association's publication number AAMA 2604-02, incorporated by reference in s. NR 484.11 (1).
NR 465.42(22) (22) “High performance coating" means any coating that meets the definition in this section of high performance architectural coating or high temperature coating.
NR 465.42(23) (23) “High temperature coating" means any coating applied to a substrate which during normal use shall withstand temperatures of at least 1000 degrees Fahrenheit.
NR 465.42(24) (24) “Hobby shop" means any surface coating operation, located at an affected source, that is used exclusively for personal, noncommercial purposes by the affected source's employees or assigned personnel.
NR 465.42(25) (25) “Initial startup" means the first time equipment is brought on line in a facility.
NR 465.42(26) (26) “Magnet wire coatings", commonly referred to as “magnet wire enamels", are applied to a continuous strand of wire which will be used to make turns, or windings, in electrical devices such as coils, transformers or motors. Magnet wire coatings provide high dielectric strength and turn-to-turn conductor insulation. This allows the turns of an electrical device to be placed in close proximity to one another which leads to increased coil effectiveness and electrical efficiency.
NR 465.42(27) (27) “Magnet wire coating machine" means equipment which applies and cures magnet wire coatings.
NR 465.42(28) (28) “Manufacturer's formulation data" means data on a material, such as a coating, that are supplied by the material manufacturer based on knowledge of the ingredients used to manufacture that material, rather than based on testing of the material with the test methods specified in s. NR 465.46 (2). Manufacturer's formulation data may include information on density, organic HAP content, volatile organic matter content and coating solids content.
NR 465.42(29) (29) “Mass fraction of organic HAP" means the ratio of the mass of organic HAP to the mass of a material in which it is contained, expressed as kg (lb) of organic HAP per kg (lb) of material.
NR 465.42(30) (30) “Month" means a calendar month or a pre-specified period of 28 days to 35 days to allow for flexibility in recordkeeping when data are based on a business accounting period.
NR 465.42(31) (31) “Non-HAP coating" means, for the purposes of this subchapter, a coating that contains no more than 0.1% by mass of any individual organic HAP that is an OSHA-defined carcinogen as specified in 29 CFR 1910.1200(d)(4) and no more than 1.0% by mass for any other individual HAP.
NR 465.42(32) (32) “Organic HAP content" means the mass of organic HAP emitted per volume of coating solids used for a coating calculated using Equation 2 of s. NR 465.46 (2). The organic HAP content is determined for the coating in the condition it is in when received from its manufacturer or supplier and does not account for any alteration after receipt. For reactive adhesives in which some of the HAP react to form solids and are not emitted to the atmosphere, organic HAP content is the mass of organic HAP that is emitted, rather than the organic HAP content of the coating as it is received.
NR 465.42(33) (33) “Permanent total enclosure" or “PTE" means a permanently installed enclosure that meets the criteria of Method 204 in 40 CFR part 51, Appendix M, incorporated by reference in s. NR 484.04 (9), for a PTE and that directs all the exhaust gases from the enclosure to an add-on control device.
NR 465.42(34) (34) “Personal watercraft" means a boat which uses an inboard motor powering a water jet pump as its primary source of motive power and which is designed to be operated by a person or persons sitting, standing or kneeling on the vessel, rather than in the conventional manner of sitting or standing inside the vessel.
NR 465.42(35) (35) “Protective oil" means an organic material that is applied to metal for the purpose of providing lubrication or protection from corrosion without forming a solid film. This definition of protective oil includes lubricating oils, evaporative oils, including those that evaporate completely, and extrusion oils. Protective oils used on miscellaneous metal parts and products include magnet wire lubricants and soft temporary protective coatings that are removed prior to installation or further assembly of a part or component.
NR 465.42(36) (36) “Reactive adhesive" means adhesive systems composed, in part, of volatile monomers that react during the adhesive curing reaction, and, as a result, do not evolve from the film during use. These volatile components instead become integral parts of the adhesive through chemical reaction. At least 70% of the liquid components of the system, excluding water, react during the process.
NR 465.42(37) (37) “Research or laboratory facility" means a facility whose primary purpose is for research and development of new processes and products, that is conducted under the close supervision of technically trained personnel, and is not engaged in the manufacture of final or intermediate products for commercial purposes, except in a de minimis manner.
NR 465.42(38) (38) “Responsible official" has the meaning given in s. NR 400.02 (136).
NR 465.42(39) (39) “Rubber-to-metal coatings" are coatings that contain heat-activated polymer systems in either solvent or water that, when applied to metal substrates, dry to a non-tacky surface and react chemically with the rubber and metal during a vulcanization process.
NR 465.42(40) (40) “Surface preparation" means use of a cleaning material on a portion of or all of a substrate. This includes use of a cleaning material to remove dried coating, which is sometimes called depainting.
NR 465.42(41) (41) “Temporary total enclosure" means an enclosure constructed for the purpose of measuring the capture efficiency of pollutants emitted from a given source as defined in Method 204 in 40 CFR part 51, Appendix M, incorporated by reference in s. NR 484.04 (9).
NR 465.42(42) (42) “Thinner" means an organic solvent that is added to a coating after the coating is received from the supplier.
NR 465.42(43) (43) “Total volatile hydrocarbon" or “TVH" means the total amount of nonaqueous volatile organic matter determined according to Methods 204 and 204A to 204F in 40 CFR part 51, Appendix M, incorporated by reference in s. NR 484.04 (9), and substituting the term TVH each place in the methods where the term VOC is used. The TVH includes both VOC and non-VOC.
NR 465.42(44) (44) “Uncontrolled coating operation" means a coating operation from which none of the organic HAP emissions are routed through an emission capture system and add-on control device.
NR 465.42(45) (45) “Volume fraction of coating solids" means the ratio of the volume of coating solids, also known as the volume of nonvolatiles, to the volume of a coating in which it is contained, liters (gallons) of coating solids per liter (gallon) of coating.
NR 465.42(46) (46) “Wastewater" means water that is generated in a coating operation and is collected, stored or treated prior to being discarded or discharged.
NR 465.42(47) (47) “You" or “your" means the owner or operator of a facility that applies coatings to miscellaneous metal parts or products.
NR 465.42 History History: CR 05-040: cr. Register February 2006 No. 602, eff. 3-1-06.
NR 465.43 NR 465.43 Emission limits.
NR 465.43(1)(1) What emission limits must i meet?
NR 465.43(1)(a)(a) For a new or reconstructed affected source, you shall limit organic HAP emissions to the atmosphere from the affected source to the applicable limit specified in subds. 1. to 5., except as specified in par. (c), determined according to the requirements in s. NR 465.46 (2), 465.47 (2) or 465.48 (2).
NR 465.43(1)(a)1. 1. For each new or reconstructed general use coating affected source, limit organic HAP emissions to no more than 0.23 kilograms (kg) (1.9 pounds (lb)) of organic HAP per liter (gallon) of coating solids used during each 12-month compliance period.
NR 465.43(1)(a)2. 2. For each new or reconstructed high performance coating affected source, limit organic HAP emissions to no more than 3.3 kg (27.5 lb) of organic HAP per liter (gallon) of coating solids used during each 12-month compliance period.
NR 465.43(1)(a)3. 3. For each new or reconstructed magnet wire coating affected source, limit organic HAP emissions to no more than 0.050 kg (0.44 lb) of organic HAP per liter (gallon) of coating solids used during each 12-month compliance period.
NR 465.43(1)(a)4. 4. For each new or reconstructed rubber-to-metal coating affected source, limit organic HAP emissions to no more than 0.81 kg (6.8 lb) of organic HAP per liter (gallon) of coating solids used during each 12-month compliance period.
NR 465.43(1)(a)5. 5. For each new or reconstructed extreme performance fluoropolymer coating affected source, limit organic HAP emissions to no more than 1.5 kg (12.4 lb) of organic HAP per liter (gallon) of coating solids used during each 12-month compliance period.
NR 465.43(1)(b) (b) For an existing affected source, you shall limit organic HAP emissions to the atmosphere from the affected source to the applicable limit specified in subds. 1. to 5., except as specified in par. (c), determined according to the requirements in s. NR 465.46 (2), 465.47 (2) or 465.48 (2).
NR 465.43(1)(b)1. 1. For each existing general use coating affected source, limit organic HAP emissions to no more than 0.31 kg (2.6 lb) of organic HAP per liter (gallon) of coating solids used during each 12-month compliance period.
NR 465.43(1)(b)2. 2. For each existing high performance coating affected source, limit organic HAP emissions to no more than 3.3 kg (27.5 lb) of organic HAP per liter (gallon) of coating solids used during each 12-month compliance period.
NR 465.43(1)(b)3. 3. For each existing magnet wire coating affected source, limit organic HAP emissions to no more than 0.12 kg (1.0 lb) of organic HAP per liter (gallon) of coating solids used during each 12-month compliance period.
NR 465.43(1)(b)4. 4. For each existing rubber-to-metal coating affected source, limit organic HAP emissions to no more than 4.5 kg (37.7 lb) of organic HAP per liter (gallon) of coating solids used during each 12-month compliance period.
NR 465.43(1)(b)5. 5. For each existing extreme performance fluoropolymer coating affected source, limit organic HAP emissions to no more than 1.5 kg (12.4 lb) of organic HAP per liter (gallon) of coating solids used during each 12-month compliance period.
NR 465.43(1)(c) (c) If your facility's surface coating operations meet the applicability criteria of more than one of the sub-category emission limits specified in par. (a) or (b), you may comply separately with each sub-category emission limit or comply using one of the alternatives in subd. 1. or 2.
NR 465.43(1)(c)1. 1. If the general use or magnet wire surface coating operations subject to only one of the emission limits specified in par. (a) 1. or 3. or (b) 1. or 3. account for 90% or more of the surface coating activity at your facility, then compliance with that one emission limit in this subchapter for all surface coating operations constitutes compliance with the other applicable emission limits. You shall use liters (gallons) of solids used as a measure of relative surface coating activity over a representative period of operation. You may estimate the relative volume of coating solids used from parameters other than coating consumption and volume solids content. The determination of predominant activity shall accurately reflect current and projected coating operations and shall be verifiable through appropriate documentation. The use of parameters other than coating consumption and volume solids content shall be approved by the administrator. You may use data for any reasonable time period of at least one year in determining the relative amount of coating activity, as long as they represent the way the source will continue to operate in the future and are approved by the administrator. You shall determine the predominant activity at your facility and submit the results of that determination with the initial notification required by s. NR 465.45 (1) (b). Additionally, you shall determine the facility's predominant activity annually and include the determination in the next semi-annual compliance report required by s. NR 465.45 (2) (a).
NR 465.43 Note Note: An example of parameters other than coating consumption and mass solids content for estimating the relative mass of coating solids used would be design specifications for the parts or products coated and the number of items produced.
NR 465.43(1)(c)2. 2. You may calculate and comply with a facility-specific emission limit as described in subd. 2. a. to c. If you elect to comply using the facility-specific emission limit alternative, then compliance with the facility-specific emission limit and the emission limits specified in pars. (a) and (b) for all surface coating operations constitutes compliance with this and other applicable surface coating NESHAP. In calculating a facility-specific emission limit, you shall include coating activities that meet the applicability criteria of the other sub-categories and constitute more than one percent of total coating activities. Coating activities that meet the applicability criteria of other surface coating NESHAP but comprise less than one percent of coating activities need not be included in the determination of predominant activity but shall be included in the compliance calculation.
NR 465.43(1)(c)2.a. a. You are required to calculate the facility-specific emission limit for your facility when you submit the notification of compliance status required in s. NR 465.45 (1) (c), and on a monthly basis afterward using the coating data for the relevant 12-month compliance period.
NR 465.43(1)(c)2.b. b. Use Equation 1 of this subsection to calculate the facility-specific emission limit for your surface coating operations for each 12-month compliance period:
where:
Facility-specific emission limit is the facility-specific emission limit for each 12-month compliance period, kg (lb) of organic HAP per kg (lb) of coating solids used
Limiti is the new source or existing source emission limit as specified in s. NR 465.43 (1) applicable to coating operation, i, included in the facility-specific emission limit, converted to kg (lb) of organic HAP per kg (lb) of coating solids used, if the emission limit is not already in those units. All emission limits included in the facility-specific emission limit shall be in the same units.
Solidsi is the liters (gallons) of solids used in coating operation, i, in the 12-month compliance period that is subject to emission limit, i, as specified in s. NR 465.43 (1). You may estimate the volume of coating solids used from parameters other than coating consumption and volume solids content, such as design specifications for the parts or products coated and the number of items produced. The use of parameters other than coating consumption and volume solids content shall be approved by the administrator.
n is the number of different coating operations included in the facility-specific emission limit
NR 465.43(1)(c)2.c. c. If you need to convert an emission limit in another surface coating NESHAP from kg (lb) of organic HAP per kg (lb) of coating solids used to kg (lb) of organic HAP per liter (gallon) of coating solids used, you shall use the default solids density of 1.26 kg of solids per liter of coating solids (10.5 lb of solids per gallon of coating solids).
NR 465.43(2) (2)What are my options for meeting the emission limits? You shall include all coatings, thinners and other additives, and cleaning materials used in the affected source when determining whether the organic HAP emission rate is equal to or less than the applicable emission limit in sub. (1). To make this determination, you shall use at least one of the 3 compliance options listed in pars. (a) to (c). You may apply any of the compliance options to an individual coating operation, or to multiple coating operations as a group, or to the entire affected source. You may use different compliance options for different coating operations, or at different times on the same coating operation. You may employ different compliance options when different coatings are applied to the same part, or when the same coating is applied to different parts. However, you may not use different compliance options at the same time on the same coating operation. If you switch between compliance options for any coating operation or group of coating operations, you shall document this switch as required by s. NR 465.45 (3) (c), and you shall report it in the next semiannual compliance report required in s. NR 465.45 (2).
NR 465.43(2)(a) (a) Compliant material option. You shall meet all the requirements of s. NR 465.46 to demonstrate compliance with the applicable emission limit in sub. (1) using this option. To use this option, you shall demonstrate that the organic HAP content of each coating used in the coating operation or operations is less than or equal to the applicable emission limit in sub. (1), and that each thinner and other additive, and cleaning material used contains no organic HAP.
NR 465.43(2)(b) (b) Emission rate without add-on controls option. You shall meet all the requirements of s. NR 465.47 to demonstrate compliance with the emission limit in sub. (1) using this option. To use this option, you shall demonstrate that, based on the coatings, thinners and other additives, and cleaning materials used in the coating operation or operations, the organic HAP emission rate for the coating operation or operations is less than or equal to the applicable emission limit in sub. (1), calculated as a rolling 12-month emission rate and determined on a monthly basis.
NR 465.43(2)(c) (c) Emission rate with add-on controls option. You shall meet all the requirements of s. NR 465.48 to demonstrate compliance with the emission limits in sub. (1), the operating limits in sub. (3) and the work practice standards in sub. (4) using this option. To use this option, you shall demonstrate that, based on the coatings, thinners and other additives, and cleaning materials used in the coating operation or operations, and the emissions reductions achieved by emission capture systems and add-on controls, the organic HAP emission rate for the coating operation or operations is less than or equal to the applicable emission limit in sub. (1), calculated as a rolling 12-month emission rate and determined on a monthly basis. If you use this compliance option, you shall also demonstrate that all emission capture systems and add-on control devices for the coating operation or operations meet the operating limits required in sub. (3), except for solvent recovery systems for which you conduct liquid-liquid material balances according to s. NR 465.48 (2) (j), and that you meet the work practice standards required in sub. (4).
NR 465.43(3) (3)What operating limits must i meet?
NR 465.43(3)(a)(a) For any coating operation or operations on which you use the compliant material option specified in sub. (2) (a) or the emission rate without add-on controls option specified in sub. (2) (b), you are not required to meet any operating limits.
NR 465.43(3)(b) (b) For any controlled coating operation or operations on which you use the emission rate with add-on controls option specified in sub. (2) (c), except those for which you use a solvent recovery system and conduct a liquid-liquid material balance according to s. NR 465.48 (2) (j), you shall meet the operating limits specified in Table 1 of this subchapter. These operating limits apply to the emission capture and control systems on the coating operations for which you use this option, and you shall establish the operating limits during the performance test according to the requirements in s. NR 465.48 (8). You shall meet the operating limits at all times after you establish them.
NR 465.43(3)(c) (c) If you use an add-on control device other than those listed in Table 1 of this subchapter, or wish to monitor an alternative parameter and comply with a different operating limit, you shall apply to the administrator for approval of alternative monitoring under 40 CFR 63.8(f).
NR 465.43(4) (4)What work practice standards shall i meet?
NR 465.43(4)(a)(a) For any coating operation or operations on which you use the compliant material option specified in sub. (2) (a) or the emission rate without add-on controls option specified in sub. (2) (b), you are not required to meet any work practice standards.
NR 465.43(4)(b) (b) If you use the emission rate with add-on controls option in sub. (2) (c), you shall develop and implement a work practice plan to minimize organic HAP emissions from the storage, mixing and conveying of coatings, thinners, other additives and cleaning materials used in, and waste materials generated by the controlled coating operations for which you use this option; or you shall meet an alternative standard as provided in par. (c). The plan shall specify practices and procedures to ensure that, at a minimum, the elements specified in subds. 1. to 5. are implemented.
NR 465.43(4)(b)1. 1. All organic-HAP-containing coatings, thinners, other additives, cleaning materials and waste materials shall be stored in closed containers.
NR 465.43(4)(b)2. 2. Spills of organic-HAP-containing coatings, thinners, other additives, cleaning materials and waste materials shall be minimized.
NR 465.43(4)(b)3. 3. Organic-HAP-containing coatings, thinners, other additives, cleaning materials and waste materials shall be conveyed from one location to another in closed containers or pipes.
NR 465.43(4)(b)4. 4. Mixing vessels which contain organic-HAP-containing coatings and other materials shall be closed except when adding to, removing or mixing the contents.
NR 465.43(4)(b)5. 5. Emissions of organic HAP shall be minimized during cleaning of storage, mixing and conveying equipment.
NR 465.43(4)(c) (c) As provided in 40 CFR 63.6(g), the U. S. EPA may choose to grant you permission to use an alternative to the work practice standards in this subsection.
NR 465.43 History History: CR 05-040: cr. Register February 2006 No. 602, eff. 3-1-06.
NR 465.44 NR 465.44 General compliance requirements.
NR 465.44(1)(1) What are my general requirements for complying with this subchapter?
NR 465.44(1)(a)(a) You shall be in compliance with the emission limits in this subchapter as specified in subds. 1. and 2.
NR 465.44(1)(a)1. 1. Any coating operation or operations for which you use the compliant material option or the emission rate without add-on controls option shall be, as specified in s. NR 465.43 (2) (a) and (b), in compliance with the applicable emission limit in s. NR 465.43 (1) at all times.
NR 465.44(1)(a)2. 2. Any coating operation or operations for which you use the emission rate with add-on controls option shall be, as specified in s. NR 465.43 (2) (c), in compliance with the emission limits as specified in subd. 2. a. to c.
NR 465.44(1)(a)2.a. a. The coating operation or operations shall be in compliance with the applicable emission limit in s. NR 465.43 (1) at all times except during periods of startup, shutdown and malfunction.
NR 465.44(1)(a)2.b. b. The coating operation or operations shall be in compliance with the operating limits for emission capture systems and add-on control devices required by s. NR 465.43 (3) at all times except during periods of startup, shutdown and malfunction, and except for solvent recovery systems for which you conduct liquid-liquid material balances according to s. NR 465.48 (2) (j).
NR 465.44(1)(a)2.c. c. The coating operation or operations shall be in compliance with the work practice standards in s. NR 465.43 (4) at all times.
NR 465.44(1)(b) (b) You shall always operate and maintain your affected source, including all air pollution control and monitoring equipment you use for purposes of complying with this subchapter, according to the provisions in s. NR 460.05 (4) (a) 1.
NR 465.44(1)(c) (c) If your affected source uses an emission capture system and add-on control device, you shall develop and implement a written startup, shutdown and malfunction plan according to the provisions in s. NR 460.05 (4) (c). The plan shall address the startup, shutdown and corrective actions in the event of a malfunction of the emission capture system or the add-on control device. The plan shall also address any coating operation equipment that may cause increased emissions or that would affect capture efficiency if the process equipment malfunctions, such as conveyors that move parts among enclosures.
NR 465.44(2) (2)What parts of the general provisions apply to me? You shall comply with the applicable general provisions requirements in ch. NR 460. Appendix MMMM in ch. NR 460 shows which parts of the general provisions in ch. NR 460 apply to you.
NR 465.44 History History: CR 05-040: cr. Register February 2006 No. 602, eff. 3-1-06.
NR 465.45 NR 465.45 Notifications, reports and records.
NR 465.45(1)(1) What notifications must i submit?
NR 465.45(1)(a)(a) General. You shall submit the notifications in ss. NR 460.06 (2), 460.07 (6) (c) and 460.08 (2) to (5) and (8) that apply to you by the dates specified in those sections, except as provided in pars. (b) and (c).