Dj is the density of thinner, j, kg thinner per liter thinner
Volk is the volume of cleaning material, k, used in the coating operation controlled by the solvent recovery system during the compliance period, liters
Dk is the density of cleaning material, k, kg cleaning material per liter cleaning material
m is the number of different coatings used in the coating operation controlled by the solvent recovery system during the compliance period
n is the number of different thinners used in the coating operation controlled by the solvent recovery system during the compliance period
p is the number of different cleaning materials used in the coating operation controlled by the solvent recovery system during the compliance period
NR 465.28(2)(g)7.7. Calculate the mass of organic HAP emissions reduction for the coating operation controlled by the solvent recovery system during the compliance period, using the following equation: (Equation 3)
where:
HCSR is the mass of organic HAP emissions reduction for the coating operation controlled by the solvent recovery system using a liquid-liquid material balance during the compliance period, kg
AI is the total mass of organic HAP in the coatings used in the coating operation controlled by the solvent recovery system, kg, calculated using Equation 1A in par. (f)
BI is the total mass of organic HAP in the thinners used in the coating operation controlled by the solvent recovery system, kg, calculated using Equation 1B in par. (f)
CI is the total mass of organic HAP in the cleaning materials used in the coating operation controlled by the solvent recovery system, kg, calculated using Equation 1C in par. (f)
RV is the volatile organic matter collection and recovery efficiency of the solvent recovery system, percent, from Equation 2 in subd. 6.
NR 465.28(2)(h)(h) Determine the total volume of coating solids used, liters, which is the combined volume of coating solids for all the coatings used during the compliance period, using Equation 2 in s. NR 465.27 (2) (f). NR 465.28(2)(i)(i) Determine the organic HAP emission rate to the atmosphere, kg organic HAP per liter coating solids used during the compliance period, using the following equation: (Equation 4)
where:
HHAP is the organic HAP emission rate to the atmosphere during the compliance period, kg organic HAP per liter coating solids used
He is the total mass of organic HAP emissions before add-on controls from all the coatings, thinners and cleaning materials used during the compliance period, kg, determined according to par. (d)
HC,i is the total mass of organic HAP emissions reduction for controlled coating operation, i, during the compliance period, kg, from Equation 1 in par. (f)
HCSR,j is the total mass of organic HAP emissions reduction for controlled coating operation, j, during the compliance period, kg, from Equation 3 in par. (g)
Vst is the total volume of coating solids used during the compliance period, liters, from Equation 2 in s. NR 465.27 (2) (f) q is the number of controlled coating operations except those controlled with a solvent recovery system
r is the number of coating operations controlled with a solvent recovery system
NR 465.28(2)(j)(j) Demonstrate initial compliance with the emission limit, by ensuring that the organic HAP emission rate calculated using Equation 4 in par. (i), is less than or equal to the applicable emission limit in s. NR 465.25 (3). Keep all records as required by s. NR 465.25 (3) and (4). As part of the notification of compliance status required by s. NR 465.25 (1), identify the coating operation or operations for which you used the emission rate with add-on controls option and submit a statement that the coating operation or operations was or were in compliance with the emission limitations during the initial compliance period because the organic HAP emission rate was less than or equal to the applicable emission limit in s. NR 465.23 (1), and you achieved the operating limits and the work practice standards required by s. NR 465.23 (3) and (4) respectively. NR 465.28(4)(4) How do I demonstrate continuous compliance with the emission limitations?.