NR 439.03(4)(b)(b) The person shall report the cause and duration of the exceedance, the period of time considered necessary for correction, and measures taken to minimize emissions during the period. NR 439.03(4)(c)(c) The owner or operator of a source which has been issued an operation permit shall report to the department by the next business day any deviation from permit requirements, the probable cause of the deviation, and any corrective actions or preventive measures taken or which will be taken to prevent future deviations. NR 439.03(5)(5) The owner or operator of a source required to operate a continuous emission monitoring system or monitoring device shall notify the department of any shutdown, breakdown or malfunction of such device or system which is anticipated to continue in excess of one week. Notice shall occur at the next business day following the onset of the shutdown, breakdown or malfunction. NR 439.03(6)(6) The owner or operator of a source shall report to the department in advance schedules for planned shutdown and startup of air pollution control equipment and the measures to be taken to minimize the down time of the control equipment while the source is operating. Scheduled maintenance or any other scheduled event, including startup, shutdown or sootblowing procedures which have been approved by the department under s. NR 436.03 (2) (b), which causes an emission limitation to be exceeded shall also be reported in advance to the department. Advance reporting under this subsection does not relieve any person from the duty to comply with any applicable emission limitation. NR 439.03(7)(7) Any owner or operator of a coating or printing line achieving compliance by means of s. NR 422.04 (1) shall, upon startup of the line, or upon changing the method of compliance to s. NR 422.04 (1), notify the department. The notification shall contain: NR 439.03(7)(c)(c) A description of the method by which the owner or operator will measure or calculate the volume of each coating or ink applied each day on each coating or printing line. NR 439.03(8)(8) The responsible official required to certify the source’s compliance status under sub. (1) (c) shall include in each certification the following information: NR 439.03(8)(a)(a) Identification of each permit term or condition that is the basis of the compliance certification. NR 439.03(8)(b)(b) The compliance status of the stationary source with respect to each term or condition identified in par. (a). NR 439.03(8)(c)(c) Information on whether compliance was continuous or intermittent. NR 439.03(8)(d)(d) The methods used for determining the compliance status of the stationary source, currently and over the previous 12 month period. NR 439.03(8)(e)(e) Any other information the department may require, as specified in the operation permit, to determine the compliance status of the source. NR 439.03(9)(9) All certifications required to be submitted under sub. (1) (c) by a part 70 source shall be submitted to the administrator and the department. NR 439.03(10)(10) Each report required under this section shall be certified by a responsible official as to its truth, accuracy and completeness. This certification and any other certification required under this chapter shall state that, based on information and belief formed after reasonable inquiry, the statements and information in the document are true, accurate and complete. NR 439.03(11)(11) All certifications made under this section and all material statements and representations made in any report or notice required by an operation permit shall be truthful. NR 439.03(12)(12) No one may render inaccurate any monitoring device or method required under this chapter or in a construction permit or an operation permit. NR 439.03 HistoryHistory: Renum. from NR 154.06 (2) and am. Register, September, 1986, No. 369, eff. 10-1-86; renum. from NR 439.025, r. (4) and (5), renum. and am. (1) to (3), (6) to (8), Register, September, 1987, No. 381, eff. 10-1-87; correction in (4) (a) 1. made under s. 13.93 (2m) (b) 7., Stats., Register, August, 1989, No. 404; am. (4) (a) 2., Register, May, 1992, No. 437, eff. 6-1-92; renum. (1) to be (1) (a), cr. (1) (b) and (c), (4) (c) and (7) to (12), am. (4) (a) 2., Register, December, 1993, No. 456, eff. 1-1-94; correction in (1) (c) made under s. 13.93 (2m) (6) 7., Stats., Register, February, 1995, No. 470; am. (1) (b), (c), (2) and (8) (intro.), Register, December, 1997, No. 504, eff. 1-1-98; CR 02-097: am. (4) (a) 1. Register June 2004 No. 582, eff. 7-1-04. NR 439.04(1)(1) The owner or operator of an air contaminant source to which chs. NR 400 to 499 apply shall maintain the following records: NR 439.04(1)(a)(a) Records of all sampling, testing and monitoring conducted or required under chs. NR 400 to 499 or under an air pollution control permit. Records of sampling, testing or monitoring shall include the following: NR 439.04(1)(a)1.1. The date, monitoring site and time and duration of sampling, testing, monitoring and measurements. NR 439.04(1)(a)4.4. The analytical techniques or methods used, including supporting information such as calibration and maintenance records and all original recording charts for continuous monitoring instrumentation including emissions or equipment monitors. NR 439.04(1)(a)6.6. The relevant operating conditions that existed at the time of sampling, testing, monitoring or measurement.